Brochure PDF
Brochure PDF
Brochure PDF
COMPANY BROCHURE
TRANSFORMER (Distr ibution & Power)
Transformer is an electrical device which, by the principles of
electromagnetic induction, transfers electrical energy from one Your Need Our Assistance
---�
PACKAGE SUBSTATION (PSS/CSS)
Range 1 OOKVAto 2.5MVA) up to 33KV
PSS can be supplied with APFC or metering system, also with several
outgoings as per client requirement.
RMU may be 1-way, 2-way or 3-way. Compact/Unit substations are
self-contained units available in different designs and dimensions.
Package substation (PSS) is ready to use application power station, it
saves the time, space & money, there are following type of PSS are
-·
being manufacture under ATS:
TYPE-1550
In this type of PSS capacity is 100 to 315 KVA voltage up to 33 KV
TYPE-2000
In this type of PSS capacity is 400 to 1600 KVA voltage up to 33 KV
TYPE-2400
In this type of PSS capacity is 500 to 2500 KVA with on load tap
changer & off load.
SERVO
Techno Power Solutions is manufacturing wide range of LT
AUTOMATIC VOLTAGE REGULATORS also commonly called as
SERVO STABILIZERS. Voltage fluctuation is a common phenomenon
in every part of the country. lnspite of best efforts, Public utility
companies can not ensure quality power to consumers due to long
and inadequate distribution lines and irregular load patterns on
distribution network. The stable Input supply is a basic necessity of
sophisticated equipment to give optimal performance. Major
industrial loads are inductive in nature (i.e .A.C. Motors).
[email protected]
RMU / VCB (HT PANELS)
HY Panel like VCB, RMU
• Suitable for distribution network of 12 kV, 24 kV, 36 kV.
• Available in Non extensible, Extensible and modular range
metering facilities.
• Metal enclosed design with IP 54 degree of protection
suitable for both indoor & outdoor duties.
• Fully interlocked operation with pad locking facility for
maximum operator protection and safety.
Maintenance free and low environmental impact.
Actuators (Motorized operation for ring switches and
breakers).
Choice of wide range of self/ auxiliary powered relay protection or
TLF.
LV DISTRIBUTION PANEL
• Power control centre (PCC) Panel
•
.
-
.. .. - -
Motor control centre (MCC) Panel 't, A
• . ,,,;. .
...
Synchronizing Panel • g.g,, ,:; . . w:: . W"' • "' .
I
•
. . ...... .. ••.
'
..
Ii ■ , 11 .
Relay control Panel
...
■:: .. . w::. w:: ..
•
....•• ••. ••.. ••..•. •..
•
PLC Panel
Drive Panel �]
Ill
..""
Iii
.. H . ■:: . .. •
SUPPLY OF SPARES
.....,........,.,......,.....,.,.,- Right Part at the right time will reduce the down time.
• PWL is fully geared to supply spares of all rating and make of
• transformers. Spares are procured and checked as per standard quality
• norms of PWL. Spares are procured from approved sources.
• Minimum cycle time through planning, foresight, focus and thrust.
OTHER SERVICES FOR TRANSFORMERS -PWL offers solutions for Transformer problems.
• Site Repair services for all type & make of transformers.
• Dehydration & filtration of transformer oil at site.
•
•
Oil Testing at site.
Carry out special diagnostic testing of transformers, eg DGA in Oil, Thermography, FU RAN test etc.
www.pwlng.com
• Analysis & interpretation ofTest results for condition assessment of transformers.
• Failure analysis and cost effective and efficient restoration of transformer with minimum down time.
• Annual Maintenance contract for transformers.
life mainly depends on the quality of Insulation Oil volume it contains. Regular transformer oil filtration
assures long and consistent results from the transformer.
• Transformer oil purification eliminates solid impurities like sludge, dissolved moisture, dissolved gases from the oil
and also improves the acidity of the oil.
• We are fully equipped with a skilled team of operators who conduct on-site filtration and remove water contents,
gases, and solid contaminants from insulating fluids, recovering oil dielectric strength (BDV). Transformer oil
purifier also helps dry out moisture inside cellulose paper insulation & winding. Particulate impurities are separated
gradually, from coarse particles to tiny ones, as they pass through the filter assembly.
OIL TESTING
• Over time the oil is exposed to mechanical and electrical stress as well as to chemical contamination. To maintain
and extend the life of the power transformer and to avoid severe breakdowns, regular testing of the transformer oil
is very important and is done as per (IS 1866)
• We have tie ups with Oil testing laboratories for performing all test as required. We provide on-site Oil Sampling for
the purpose of Laboratory Oil testing & Analysis.
• TPS Service engineers have been trained to obtain a clean oil sample in accordance to IS 1866 for testing and
analysis.
PAINTING & REFURBISHMENT AT SITE
We provide on-site Sub Station Cleaning & Re-Painting of transformers and other electrical equipment. The process
includes
• Rust removal and treatment
• Flow/Spray painting (over 100 microns per coat)