0% found this document useful (0 votes)
70 views9 pages

(Approved) DMS-3 Reprograming PDF

This document provides instructions for reprogramming a DMS-3 seat using either a connection cable with a toggle switch or without a toggle switch. The process involves connecting the adapter to the machine and computer, enabling download mode, selecting the program download option in the tools menu, entering a password, selecting the program file, installing the new version, and checking the machine once complete.

Uploaded by

Irul Umam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views9 pages

(Approved) DMS-3 Reprograming PDF

This document provides instructions for reprogramming a DMS-3 seat using either a connection cable with a toggle switch or without a toggle switch. The process involves connecting the adapter to the machine and computer, enabling download mode, selecting the program download option in the tools menu, entering a password, selecting the program file, installing the new version, and checking the machine once complete.

Uploaded by

Irul Umam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

DMS-3 Reprogramming

p g g Procedure
*Program Download
https://ap1.salesforce.com/sfc/#version?selectedDocumentId=06990000001aveN

1 * 1-1. In case that DMS connection cable has toggle switch as a picture
below,
a Connect adapter to machine.

b Connect adapter to computer.

b
a
c

c Turn on the toggle switch. Then c


EPOS turns into “downloading
mode”(In order to stop sending ON
the electronic signal).

OFF

1
DMS-3 Reprogramming
p g g Procedure

1 * 1-2. In case that DMS connection cable doesn’t have toggle switch,

a Locate EPOS at the back of seat. a

b Open the plate. b

2
DMS-3 Reprogramming
p g g Procedure

1 * 1-2. In case that DMS connection cable doesn’t have toggle switch,

c Remove bolts(6EA) on c
EPOS cover.

d Find DIP switch of marked d


location.
T
Turn th 1st switch.
on the it h

ON

OFF
3
DMS-3 Reprogramming
p g g Procedure

11
2 Execute DMS-3 program
4
Select “Tools” tap, then click
“Download Program”.

5
3 Enter password [11830].

6
4 Once Firmware update pops up,
click “Program” button.
Please check the port number is
correct,
t before
b f click.
li k

4
DMS-3 Reprogramming
p g g Procedure

5 In order to delete old version of


EPOS program, select
"DX_Clear.hex" that is saved
at the step #1 of this instruction 7
and open the file.

6 Key Off & Key On 8


Then, DMS shows programming
status
status.

Once update is completed, Click 9


7
OK and Key Off
“OK” Off.

5
DMS-3 Reprogramming
p g g Procedure

8
*1-1. In case that DMS connection cable has toggle switch,

a Turn off the toggle switch 10

b To begin the installation of new


version of software, turn on the
key.

9 * 1-2. In case that DMS connection cable doesn’t have toggle switch,

19 10
a Turn the DIP switch off

b To begin the installation of new


version of software, turn on the
1st switch.

6
DMS-3 Reprogramming
p g g Procedure

11
10 Execute DMS-3 program
Select “Tools” tap, then click
“Download Program”.

12
11 Enter password [11830].

13
12 Once Firmware update pops up,
click “Program” button.
Please check the port number is
correct before click.
correct, click

7
DMS-3 Reprogramming
p g g Procedure

13 In order to install the new version


of EPOS program,
select “EPOS Program " that is
saved at the step #1 of this
14
instruction and open the file.

14

14 Key Off & Key On 15


Then, DMS shows programming
status. .

15 Once update is completed, Click 16


“OK” Button and Key Off.

8
DMS-3 Reprogramming
p g g Procedure

16 *1-1. In case that DMS connection cable has toggle switch as a picture
below,
Turn the toggle switch off and 17
a
turn on E/G & Check Machine.
Machine

16 * 1-2. In case that DMS connection cable doesn’t have toggle switch,

a Turn the EPOS DIP switch off 17


and
d turn
t on E/G & Check
Ch k
Machine.