0% found this document useful (0 votes)
207 views14 pages

Essenza Host

essenza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
207 views14 pages

Essenza Host

essenza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

l

g
E
s
n
m
ie
S

MAGNETOM
MR

Function Description
System

Host

MAGNETOM ESSENZA
10130587

© Siemens 2006
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.

Print No.: M4-060.850.12.03.02 English


Replaces: M4-060.850.12.02.02 Doc. Gen. Date: 11.08
2 Revision / Disclaimer
1Revision / Disclaimer

Document revision level


The document corresponds to the version/revision level effective at the time of system
delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.

Disclaimer
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise autho-
rized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated with
or authorized by Siemens or one of its affiliates are directed to contact one of the local
offices of Siemens or one of its affiliates before attempting installation or service proce-
dures.

MAGNETOM M4-060.850.12.03.02 Page 2 of 14 Siemens


11.08 CS SD MR
Table of Contents 3
0Table of Contents

1 _______ Introduction ____________________________________________________ 4

General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MR console (MRC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MR satellite console (MRSC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 _______ Host CELSIUS R640 for MRC and MRSC_____________________________ 7

Hardware of MRC and MRSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7


General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3 _______ Host HP XW4600 for MRC and MRSC ______________________________ 10

Hardware of MRC and MRSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10


General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

4 _______ Changes to previous version _____________________________________ 13

Siemens M4-060.850.12.03.02 Page 3 of 14 MAGNETOM


11.08 CS SD MR
4 Introduction
1-
General
1Introduction

The Host computer concept for MAGNETOM ESSENZA systems is the same as used for
all syngo MR systems, i e. the Host is based on PC hardware.
This is true for both the main console (MRC) and the optional satellite console (MRSC).

Fig. 1: MRC components

What is new compared to older systems is that the measurement control (AMC) and the
image reconstruction system (MRIR) are combined in one single computer system called
MARS (Measurement And Reconstruction System).

Fig. 2: MARS

MAGNETOM M4-060.850.12.03.02 Page 4 of 14 Siemens


11.08 CS SD MR
Introduction 5

Overview 1.1

Before you continue, a few words on the designations used throughout the Host description
may be in order to avoid unnecessary confusion.
The term Host refers simply to a computing element which is used to control or act as the
"host" of a system. The "host" of our MR system is termed "MR Console", or MRC for short.
In addition to the MRC, an optional satellite MR console, or MRSC is available. Although
practically the same as the MRC, it is only intended for post-processing images. For this
reason, it may not contain some of the hardware components found in the MRC. Also, the
software configuration will be different, since the MRSC does not require all that system
control software. A description of the main differences is provided on the next page.

Fig. 3: Host and MARS

Siemens M4-060.850.12.03.02 Page 5 of 14 MAGNETOM


11.08 CS SD MR
6 Introduction

Function 1.2

MR console (MRC) 0

The major tasks of the Host (MRC) are:


• User interface (syngo) - provides the hardware and software for the user interface
• Converts sequence measurement parameters from the user into system-specific com-
mands and passes these on to the MARS
• Image post-processing and image display functionalities
• Archiving (mass storage, filming)
The MRC is connected to the MR system via an Ethernet LAN connection. This network
connection will be referred to as the "internal network".

MR satellite console (MRSC) 0

The MR satellite console (MRSC) is an option. Its major tasks are:


• Image viewing
• Post-processing
• Archiving images
The MRSC Host connects to the Host MRC over an additional Ethernet switch, delivered
with the MRSC option. This switch is required to decouple the large volume of image data
transfers from the customer’s LAN. This network connection will be referred to as the "out-
side network", or "customer network".
The configuration of the MRSC computer is the same as the MRC Host with one exception:
no pixel data hard drive (database and pixel data on one hard disk only).

MAGNETOM M4-060.850.12.03.02 Page 6 of 14 Siemens


11.08 CS SD MR
Host CELSIUS R640 for MRC and MRSC 7
2-
Hardware of MRC and MRSC
2Host CELSIUS R640 for MRC and MRSC

General 0

The first Host model is equipped with the following components:


• Computer unit:
- 3 hard drives (2 in the case of MRSC): one for the operating system and NUMARIS,
one for the database and one for the pixel image files
- 1 DVD-recorder for image archiving
- 1 DVD-ROM drive for software updates
- 1 floppy drive for installing license keys
- 1 serial port
- 2 network interfaces: one for system-internal communication and one for connection
to the customer’s LAN
- 4 USB ports on the back: one is used for a dongle, one is used to charge the PERU
and PPU (both are parts of the PMU option) and the remaining two are used for key-
board and mouse.
- (2 PS/2 connections for keyboard and mouse) not used
- high-performance/high-resolution graphics card
• High-resolution LCD monitor for image and dialog display
• USB keyboard and mouse

Performance data 0

The following table shows an overview of important performance data of the host:

CPU 2*dual core CPU 2.6 GHz (Intel-Woodcrest)


Memory 4 GB (four 1 GB DDR2 FB-DIMM)
Graphics card Nvidia FX3500
DVD recorder Plextor PX-800A
HDDs size three 73 GB SAS drives

Siemens M4-060.850.12.03.02 Page 7 of 14 MAGNETOM


11.08 CS SD MR
8 Host CELSIUS R640 for MRC and MRSC
Host block diagram
Fig. 4:
MAGNETOM M4-060.850.12.03.02 Page 8 of 14 Siemens
11.08 CS SD MR
Host CELSIUS R640 for MRC and MRSC 9

Fig. 5: Host, front view Fig. 6: Host, rear view


Pos. 1 DVD-ROM drive Pos. 1 USB keyboard
Pos. 2 DVD recorder Pos. 2 USB mouse
Pos. 3 Floppy disk drive Pos. 3 Serial port
Pos. 4 2 USB ports Pos. 4 USB dongle
Pos. 5 LAN to MARS
Pos. 6 LAN to customer network
Pos. 7 Monitor

Siemens M4-060.850.12.03.02 Page 9 of 14 MAGNETOM


11.08 CS SD MR
10 Host HP XW4600 for MRC and MRSC
3-
Hardware of MRC and MRSC
3Host HP XW4600 for MRC and MRSC

General 0

The current Host model is equipped with the following components:


• Computer unit:
- 3 hard drives (2 in the case of MRSC): one for the operating system and NUMARIS,
one for the database and one for the pixel image files (MRC only)
- 1 DVD-recorder for image archiving
- 1 DVD-ROM drive for software updates
- 1 floppy drive for installing license keys
- 1 serial port
- 2 network interfaces (1 in the case of MRSC): one for system-internal communica-
tion (MRC only) and one for connection to the customer’s LAN
- 6 USB ports on the back: one is used for a dongle, one is used to charge the PERU
and PPU (both are parts of the PMU option) and two are used for keyboard and
mouse.
- 2 USB ports on the front:
- (2 PS/2 connections for keyboard and mouse) not used
- high-performance/high-resolution graphics card
• High-resolution LCD monitor for image and dialog display
• USB keyboard and mouse

Performance data 0

The following table shows an overview of important performance data of the host:

CPU one 2.66 GHz Intel Core2Quad


Memory 4 GB (four 1 GB DDR2 FB-DIMM)
Graphics card Nvidia FX3500
DVD recorder Plextor PX-800A
HDDs size three 73 GB SAS drives

MAGNETOM M4-060.850.12.03.02 Page 10 of 14 Siemens


11.08 CS SD MR
Host HP XW4600 for MRC and MRSC 11
HP Host block diagram
Fig. 7:
Siemens M4-060.850.12.03.02 Page 11 of 14 MAGNETOM
11.08 CS SD MR
12 Host HP XW4600 for MRC and MRSC

Fig. 9: HP Host, rear view


Fig. 8: HP Host, front view Pos. 1 Serial port
Pos. 1 DVD-ROM drive
Pos. 2 USB keyboard
Pos. 2 DVD recorder
Pos. 3 USB mouse
Pos. 3 Floppy disk drive
Pos. 4 USB dongle
Pos. 4 2 USB ports
Pos. 5 LAN to customer network
Pos. 6 LAN to MARS
Pos. 7 Monitor

MAGNETOM M4-060.850.12.03.02 Page 12 of 14 Siemens


11.08 CS SD MR
Changes to previous version 13
4-
4Changes to previous version

(Host HP XW4600 for MRC and MRSC / p. 10) new chapter for HP host added.

Siemens M4-060.850.12.03.02 Page 13 of 14 MAGNETOM


11.08 CS SD MR
14 Changes to previous version

MAGNETOM M4-060.850.12.03.02 Page 14 of 14 Siemens