Flexi RF Module 3TX 1800
Flexi RF Module 3TX 1800
Flexi RF Module 3TX 1800
RF Module 3TX 1800 (FXEB)
GSM/EDGE BSS, Rel. GSM 17, Operating Documentation, Issue 03 (HTML) > Flexi Multiradio BTS Descriptions >
Flexi Multiradio BTS RF Module and Remote Radio Head Description > Descriptions of 3TX RF Modules
Property Value
Output power 3x80 W
MIMO 2TX
Outdoor installation Yes
SW supported technologies GSM, FDDLTE
TX frequency range 18051880 MHz
RX frequency range 17101785 MHz
DL instantaneous bandwidth 35 MHz in GSM
50 MHz in LTE
UL instantaneous bandwidth 60 MHz
DL filter bandwidth 75 MHz
UL filter bandwidth 75 MHz
Interfaces
FXEB interfaces
Place the cursor over the table or module for more information.
http://10.133.137.78/GSM 1/5
5/9/2017 Flexi RF Module 3TX 1800 (FXEB)
ALD support via antenna ports Value
AISG ANT1, ANT3, ANT5, RET: AISG 2.0
CWA (for nonAISG installations) Yes
Voltage ANT1, ANT3, ANT5: 24 V or 13 V
ANT2, ANT4, ANT6: 13 V
RET: 24 V
Power per port 30 W
Electrical specifications
http://10.133.137.78/GSM 2/5
5/9/2017 Flexi RF Module 3TX 1800 (FXEB)
Table: FXEB electrical specifications
Property Value
Nominal supply voltage 48.0 V DC
Nominal input voltage range 40.5 V DC to 57.0 V DC
Extended input voltage range 36.0 V DC to 40.5 V DC
57.0 V DC to 60.0 V DC
Power consumption
Table: FXEB power consumption
Table: Recommended FXEB power backoff in 256 QAM mode
Single carrier [dB] Dual carrier [dB]
0.8 1.4
Property Value
Installation options
floor/stack installation
pole installation
wall installation
19'' rack/cabinet
IP rating IP65
http://10.133.137.78/GSM 3/5
5/9/2017 Flexi RF Module 3TX 1800 (FXEB)
Property Value
Related optional items Pole installation
Flexi Mounting Kit for Floor, Wall and Pole (FMFA)
Flexi Pole Kit (FPKA)
Flexi Pole Kit (FPKC)
Flexi Module Casing (EMHx)
Floor/Wall installation
Flexi Mounting Kit for Floor, Wall and Pole (FMFA)
Flexi Module Casing (EMHx)
Outdoor 19'' rack
Flexi Module Casing (EMHx)
Cabinet/indoor 19''' rack
No optional items needed
Height Core RFM: 115 mm (4.5 in.)
Depth Core RFM: 400 mm (15.7 in.)
Without front covers: 422 mm (16.6 in.)
With front covers: 560 mm (22.1 in.)
Width Core RFM: 420 mm (16.5 in.)
Without front covers: 447 mm (17.6 in.)
With front covers: 492 mm (19.4 in.)
Weight 25 kg (55.1 lb)
Volume 19.3 l
Environmental specifications
Table: FXEB environmental specifications
Property Value
Maximum operational outdoor temperature (at constant high ambient temperature maximum +55°C (131°F)
output power might be limited)
Minimum operational temperature (including cold start) 35°C (31°F)
LEDs
Table: FXEB LEDs
Major alarm affecting the whole RF Module
Major alarm affecting the whole RF Module
Major/Critical alarm affecting a module subcomponent or
antenna carrier
Yellow, stable No alarm
Until software download begins
The carriers are blocked from BTS
There is no connection to any System Module
http://10.133.137.78/GSM 4/5
5/9/2017 Flexi RF Module 3TX 1800 (FXEB)
Yellow, blinking No alarm
Software download in progress
Configuration in progress: RF resources are being setup, but
not yet activated
Green, stable No alarm
Software configuration is complete or supervisory: RF
resources activated and transmission is possible
Working normally, no alarm on the RF Module
RF Module fan/TX status LED: Red At least one fan is faulty or degraded
RF Module fan/TX status LED: Green All fans are working
RF Module fan/TX status LED: Color set according to RF transmission is ON
fan status, stable
RF Module fan/TX status LED: Color set according to RF transmission is OFF
fan status, blinking
Before turning RF power on, RF ports have to be terminated by nominal 50 Ω load (for example, feeder with antenna). However, if these conditions are not met, the plastic caps that
are delivered within the unused RF ports should remain in place. The plastic caps isolate RF power from the environment, and thus provide electric shock security in case RF power
is accidentally on.
Note: The minimum startup voltage is 40.5 V DC. If the input voltage is below/beyond extended limits, unit might shut down.
Related resources
Id: DN0951745 © 2017 Nokia. All rights reserved.
http://10.133.137.78/GSM 5/5