Hydrokraft Open Loop Piston Pumps - PCT - 4134418
Hydrokraft Open Loop Piston Pumps - PCT - 4134418
Hydrokraft Open Loop Piston Pumps - PCT - 4134418
Introduction LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A20 - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Typical Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A20 - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Model Codes A2F - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Basic Pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A2F - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
DF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 A30 - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 A30 - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
ST Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ST Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
FM Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 STC03A00. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
ZP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 STC03A40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 STC03A4F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 STC03A4K. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
NO Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 STC03A4K_ _ _ _C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Combination pump units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 STC03A4B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Pump Specifications STC03A4L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 STC03A50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
US. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 STC03A5F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
2 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Introduction
• Axial piston pumps with • Rotating and pressure-loaded • "Building block" design gives Available displacement sizes
swashplate design for parts are pressure balanced. these pumps a wide range of 66 ccm/rev
reliable operation and • Integrated pilot pump, application.
long life. 90 ccm/rev
filter and pressure relief
• Pressure up to 420 bar. valves available. 130 ccm/rev
Rated speed up to 180 ccm/rev
1800 min-1. Higher speeds
250 ccm/rev
possible on request.
• Oversize shafts and bearings.
DF - Pressure compensator
Proportional
LR - Power limiter control control valve
Sleeve
Shaft
Bearing
Port plate
Bearing
Swash plate Cylinder barrel Valve plate
Note
Dimensional data provided
in this catalog is subject to
change without notice.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 3
Model code •
•
Preferred standard option
Other standard option
• Special option on request
Open Loop Pumps x Not available
X Series - Basic Pumps
PVX * – * * *M* * * * * * 1 * * * S * * A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
1 Pump 14 15 Thru drive options
P – Open loop pump • • • • • 00 – None • • • • •
2 Displacement 0A – SAE A • • • • •
0B – SAE B • • • • •
V – Variable • • • • • 0C – SAE C • • • • •
F – Fixed • • • • x 0P – Pilot pump (8cm3/rev) • • • • •
3 Pump Series 0X – For tandem units • • • • •
X – “X” series • • • • • 16 Main Ports
4 Configuration 1 – SAE ports - Metric bolts • • • • •
S – Single unit • • • • • 17 Main port orientation
F – Front unit • • • • •
M – Middle unit • • • • • R – Radial (side ports) • • • • •
R – Rear unit • • • • • A – Axial (in-line rear) • • • • •
For fixed units only radial ports available
5 Separator • • • • •
6 7 8 Displacement cm3/rev (in3/rev)
18 19 Main drive shaft end
066 – 066 cm /rev (4 in /rev)
3 3
• x x x x
01 – ISO straight key • • • • •
090 – 090 cm3/rev (5.5 in3/rev) x • x x x
02 – ISO spline • • • • •
130 – 130 cm3/rev (8 in3/rev) x x • x x 20 Drive shaft seal configuration
180 – 180 cm3/rev (11 in3/rev) x x x • x S – Single shaft seal • • • • •
250 – 250 cm3/rev (15.3 in3/rev) x x x x •
*** – Non-standard (PFX only) ◊ • • • • x 21 Seal material
◊ Non-standard displacements (cm3/rev): V – FKM • • • • •
066 – 44/50 F – FKM + front bearing flushing prepared • • • • •
090 – 75 K – FKM with HP lubrication • • • • •
130 – 94/112 L – For HFC Hp-Lub + front flushing • • • • •
180 – 160 M – For HFC Hp-Lub + front + rear flushing • • • • •
9 Basic Standard
G – For HFC front + rear flushing • • • • •
A – EPDM / PTFE • • • • •
M – Metric • • • • • 22 Yoke position indicator
10 11 Mounting Flange
0 –
No position indicator • • • • •
02 – ISO 3019/2-125A2SW • • x x x V –
Visual indicator • • • • •
04 – ISO 3019/2-160A2SW x x • • x P –
Voltage indicator • • • • •
06 – ISO 3019/2 200A2SW x x x x • M Voltage + visual indicator
– • • • • •
12 Rotation Direction L Current + visual indicator
– • • • • •
R – Clockwise • • • • x SP control only
L – Counter-clockwise • • • • x 23 Surface coating
13 Maximum displacement A – Primer blue • • • • •
0 – Max. displacement adjusting screw 0 – Rust inhibitor oil • • • • •
With control DF/ZP • • • • • Other finishes on request.
With control ST +DF • • • • • 24 Control model code
With control ST +LR x x x x x
With control LR/SP/FM/ES x x x x x See fields 24 to 48 on following pages.
4 – Fixed mechanical stop ring side A • • • • • Pump Size 66 90 130 180 250
(max displacement)
5 – Fixed mechanical stop ring side B • • • • •
(min. displacement)
Pump Size 66 90 130 180 250
Note:
66cc will get new design (similar to 90 cc) and all counter-clockwise of 66cc will be outfaced in 2018.
4 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control overview For additional control options
Please look into details of modelcoding
D F Pressure compensator
with or without load sense
Note: FE, HG, DP, SM and DQ old controls should not be used anymore. If you need technical support here, please contact us at [email protected].
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 5
Model code •
•
Preferred standard option
Other standard option
X Series - DF Control
D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control Type 36 Venting valve
DF – Pressure compensator • • • • • 0 – None • • • • •
26 Displacement adjustment options
1 – Solenoid valve • • • • •
Specify voltage in 39
0 – Not applicable
37 Position monitoring
27 28 Electronic amplifier
0 – Not applicable
00 – Not applicable
38 Electric motor type
29 Yoke displacement zone
0 – Not applicable
A – Single side of centre “A” • • • • • 39 Control voltage
30 Additional functions 0 – Not applicable • • • • •
0 – None • • • • • H – 24V DC (preferred voltage) • • • • •
1 – Load sensing (standard ∆p = 15 bar) • • • • • B – 110V AC 50 Hz / 120V AC 60 Hz • • • • •
A – 2-level pressure compensator, • • • • • D – 230V AC 50 Hz / 240V AC 60 Hz • • • • •
4/2 solenoid valve
40 41
B – 2-level pressure compensator, • • • • • Customer adjustment specification
42 43
4/3 solenoid valve
0000 – None • • • • •
31 Pressure control options • • • • •
**** – Eaton assigned number as per
0 – None i.e. pilot operated with remote port (stan- • • • • • data specified in table below ◊
dard arrangement) 44 45 46 Special features
F – Remote port without pilot valve • • • • •
K – Electro - proportional relief valve, • • • • • 000 – None • • • • •
complete with electronic card *** – Defined by Eaton • • • • •
L – Electro - proportional relief valve • • • • • 47 48 Design number
with OBE
S – Slow upstroke screw adjustment ** – 10-99 assigned by Eaton • • • • •
• • • • • Pump Size 66 90 130 180 250
32 33 34 Power control
000 – Not applicable
◊ Example for customer adjustment specifications
35 Pilot oil filter Special pressure Main stage Pilot valve Load
0 – Not applicable adjustment pressure control pressure control sense
∆p
Pump Size 66 90 130 180 250
Standard setting (bar) 20 90 15
Max. setting (bar) 40 350 40
Customer-specified adjustment
(bar) ....... ....... .......
Note: Setting must be at least 30bar.
6 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •
•
Preferred standard option
Other standard option
X Series - LR Control
L R 0 0 0 A * * * * * 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
LR – Power control • • • • • 0 – None • • • • •
26 Displacement adjustment options 1 – Solenoid valve • • • • •
0 – Not applicable Specify voltage in 39
27 28 Electronic amplifier 37 Position monitoring
00 – Not applicable 0 – Not applicable
29 Yoke displacement zone 38 Electric motor type
A – Single side of centre “A” • • • • • 0 – Not applicable
30 Additional functions 39 Control Voltage
2 – Pressure limiter • • • • • 0 – Not applicable • • • • •
3 – Load sensing and pressure limiter (standard ∆p • • • • • H – 24V DC (Preferred voltage) • • • • •
= 15 bar) B – 110V AC 50 Hz / 120V AC 60 Hz • • • • •
To select Power Control without Pressure
D – 230V AC 50 Hz / 240V AC 60 Hz • • • • •
Limiter, specify ... LR ... A2F. 40 41
Customer adjustment specification
31 Pressure control options 42 43
0 – None i.e. pilot operated with remote port (stan- • • • • • 0000 – None • • • • •
dard arrangement) **** – Eaton assigned number as per • • • • •
F – Remote port without pilot valve • • • • • data specified in table below ◊
K – Electro - proportional relief valve, • • • • • 44 45 46 Special features
complete with electronic card
L – Electro - proportional relief valve • • • • •
000 – None • • • • •
with OBE *** – Defined by Eaton • • • • •
S – Slow upstroke screw adjustment • • • • • 47 48 Design number
32 33 34 Power control specification ** – 10-99 assigned by Eaton • • • • •
*** – 3-digit value in kW at 1500 rpm • • • • • Pump Size 66 90 130 180 250
35 Pilot oil filter
0 – Not applicable ◊ Example for customer adjustment specifications A2 29 30
Pump Size 66 90 130 180 250 Special pressure adjust- Main stage Pilot valve Load
ment pressure control pressure control sense ∆p
Standard setting (bar) 20 90 15
Max. setting (bar) 40 350 40
Customer-specified adjustment
(bar) ....... ....... .......
Note: Setting must be at least 30bar.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 7
Model code •
•
Preferred standard option
Other standard option
X Series - ST Control
21 = K, M or L mandatory
(HP lubrication)
22 = L mandatory
(electrical yoke position indicator)
S T * * * A * * * * * * * 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Pilot oil supply
S T – Electronic flow control by • • • • • A – Internal pilot oil supply only • • • • •
proportional valve B – External pilot oil supply only • • • • •
C – Internal + external pilot oil supply by
26 Displacement adjustment options • • • • •
check valve
C – With CETOP 3 proportional valve • • • • •
A – With CETOP 3 interface (no valve) • • • • • 37 Position monitoring
D – CETOP 3 proportional valve KBSDGV-4 with OBE • • • • • 0 – Not applicable
(electr. amplifier necessary for flow control)
38 Electric motor type
G – CETOP 3 Axis-Pro OBE valve with integr. flow • • • • •
control (no add. amplifier necessary) 0 – Not applicable
27 28 Electronic amplifier 39 Control voltage
03 – With ER9.3 amplifier card • • • • • 0 – Not applicable
05 – With DIN rail module • • • • • 40 41
00 – Without electronics • • • • • Customer adjustment specification
42 43
29 Yoke displacement zone 0000 – None • • • • •
A – Single side of centre “A” • • • • • **** – Eaton assigned number as per • • • • •
data specified in table below ◊
30 Extra functions
44 45 46 Special features
0 – Without additional options • • • • •
4 – Pressure limiter override • • • • • 000 – None • • • • •
5 – Pressure limiter and power limiter override • • • • • *** – Defined by Eaton • • • • •
31 Pressure limiter control options 47 48 Design number
0 – Including pilot relief valve • • • • • ** – 10-99 assigned by Eaton • • • • •
and remote port option Pump Size 66 90 130 180 250
F – Remote port only • • • • •
K – Proportional relief valve + • • • • • ◊ Example for customer adjustment specifications A4/A5 29 30
EEA-PAM amplifier card Special pressure Main stage Pilot valve
L – Proportional relief valve with integrated • • • • • adjustment pressure control pressure control
Electronics OBE Standard setting (bar) 20 90
32 33 34 Power control setting options Max. setting (bar) 40 350
Customer-specified
000 – No power limiter override • • • • • adjustment (bar) ....... .......
*** – 3-digit value in kW at 1500 rpm • • • • • Note: Setting must be at least 30bar.
35 Pilot oil filter
0 – Without filter • • • • • Special max. Minimum Maximum
E – Filter with electr. indicator • • • • • Displ. Adjustment displacement displacement
Pump Size 66 90 130 180 250 Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the most common
reasons for using this option. Max. displacement adjustable by screw or by stop ring- refer basic pump
model code pos 13.
Notes:
-S T control requires a min. operation pressure of >25 bar for operation. For internal pilot oil supply it must be assured that this load pressure can be
provided. Below this min. pressure value pump will automatically go on max. stroke.
- External ST control pilot pressure needs to be equal or more than 35% of max. load pressure
8 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •
•
Preferred standard option
Special option on request
FM0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control type 36 Venting valve
FM – Screw adjustment control • • • • • 0 – Not applicable
displacement range 50-100% 37 Position monitoring
26 Displacement adjustment options 0 – Not applicable
G – Not applicable 38 Electric motor type
27 28 Electronic amplifier 0 – Not applicable
00 – Not applicable 39 Control voltage
29 Yoke displacement zone 0 – Not applicable
A – Single side of centre “A” • • • • • 40 41
Customer adjustment specification
42 43
30 Additional functions
0 – Not applicable
0000 – None • • • • •
**** – Eaton assigned number as per • • • • •
31 Pressure control options data specified in table below ◊
0 – Not applicable 44 45 46 Special features
32 33 34 Power control specification 000 – None • • • • •
000 – Not applicable *** – Defined by Eaton • • • • •
35 Pilot oil filter 47 48 Design number
0 – Not applicable ** – 10-99 assigned by Eaton • • • • •
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
Notes:
- Adjustable only with load pressure ≤30 bar
- Factory setting 100%
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 9
Model code •
•
Preferred standard option
Other standard option
X Series - ZP Control
Z P * * * A 0 0 0 0 0 0 * 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Pilot oil supply
ZP – Dual displacement control • • • • • A – Internal pilot oil supply only • • • • •
B – External pilot oil supply only • • • • •
26 Displacement adjustment options C – Internal + external pilot oil • • • • •
1 – 4/2 solenoid valve • • • • • supply by check valve
A – With CETOP 3 interface (no valve) • • • • • 37 Position monitoring
27 28 Electronic amplifier 0 – Not applicable
00 – Not applicable 38 Electric motor type
29 Yoke displacement zone 0 – Not applicable
A – Single side of center "A" • • • • • 39 Control Voltage
30 Extra functions 0 – Not applicable
0 – Not applicable 40 41
Customer adjustment specification
31 Pressure limiter control options 42 43
0 – Not applicable 0000 – None • • • • •
32 33 34 Power control specification
**** – Eaton assigned number as per • • • • •
data specified in table below ◊
000 – Not applicable
44 45 46 Special features
35 Pilot oil filter
000 – None • • • • •
0 – Not applicable *** – Defined by Eaton • • • • •
Pump Size 66 90 130 180 250 47 48 Design number
• • • • •
** – 10-99 assigned by Eaton
Pump Size 66 90 130 180 250
Notes:
- Basic position has max. displacement (solenoid de-engerized)
- Standard setting for minimum displacement: 50%
10 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •
•
Preferred standard option
Other standard option
X Series - SP Control
22 = P or M mandatory
(electrical yoke position indicator)
S P * * * A * * * * * * 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control type 36 Venting valve
SP – Displacement adjustment control • • • • • 0 – Not applicable
via proportional valve 37 Position monitoring
26 Displacement adjustment options 0 – Not applicable
C – CETOP 3 proportional valve KDG4V3 • • • • • 38 Electric motor type
A – CETOP 3 interface only • • • • • 0 – Not applicable
27 28 Electronic amplifier 39 Control voltage
03 – With ER9.3 amplifier card • • • • • 0 – Not applicable
05 – With DIN rail module • • • • • 40 41
00 – Without electronics • • • • • 42 43
Customer adjustment specification
29 Yoke displacement zone 0000 – None
A – Single side of centre “A” • • • • • • • • • •
**** – Eaton assigned number as per • • • • •
30 Additional functions data specified in table below ◊
44 45 46 Special features
0 – None • • • • •
4 Pressure limiter override • • • • • 000 – None • • • • •
31 Pressure control options *** – Defined by Eaton • • • • •
47 48 Design number
0 – Including pilot relief valve • • • • •
and remote port option ** – 10-99 assigned by Eaton • • • • •
F – Remote port only • • • • • Pump Size 66 90 130 180 250
K – Proportional relief valve + • • • • •
EEA-PAM amplifier card
L – Relief valve with integrated Electronics OBE • • • • • ◊ Example for customer adjustment specifications
32 33 34 Power control specification Special pressure Main stage pressure Pilot valve
adjustment control pressure control
000 – Not applicable
Standard setting (bar) 20 90
35 Pilot oil filter Max. setting (bar) 40 350
E – Filter with electrical and visual indicator • • • • • Customer-specified adjustment
0 – None • • • • • (bar) ....... .......
V – Filter with electrical and visual indicator • • • • • Note: Setting must be at least 30bar.
Pump Size 66 90 130 180 250
Special max. Minimum Maximum
Displ. Adjustment displacement displacement
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option. Max. displacement adjustable by screw or by
stop ring- refer basic pump model code pos 13.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 11
Model code •
•
Preferred standard option
Other standard option
X Series - ES control
E S * 0 0 A 0 0 0 0 0 0 0 * * 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
ES – Displacement adjustment control 0 – Not applicable
via electric motor • • • • •
37 Position monitoring
26 Displacement adjustment options A – 4 limit switches • • • • •
N – Electric motor, medium response • • • • • B – 8 limit switches • • • • •
M – Electric motor, fast response • • • • • P – 4 limit switches + yoke pos. • • • • •
P – Electric motor, slow response • • • • • feedback (potentiometer)
27 28 Control electronics T – 8 limit switches + yoke pos. • • • • •
feedback (potentiometer)
00 – Not applicable
38 Electric motor type
29 Yoke displacement zone
2 – Motor with brake (IP54) • • • • •
A – Single side of centre “A” • • • • • 3 – Motor without brake (explosion proof) • • • • •
30 Additional functions 39 Control voltage
0 – Not applicable
0 – Not applicable
31 Pressure control options 40 41
0 – Not applicable Customer adjustment specification
42 43
32 33 34 Power control specification 0000 – None
• • • • •
000 – Not applicable **** – Eaton assigned to number as per • • • • •
data specified in table below ◊
35 Pilot oil filter 44 45 46 Special features
0 – Not applicable 000 – None • • • • •
Pump Size 66 90 130 180 250 *** – Defined by Eaton • • • • •
47 48 Design Number
** – 10-99 assigned by Eaton • • • • •
Pump Size 66 90 130 180 250
12 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •
•
Preferred standard option
Other standard option
x Not available
Open Loop Pumps
X Series - No control: 2 =F
Fixed displacement PF X Models
0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
00 – No control • • • • x 0 – Not applicable
26 Displacement adjustment options 37 Position monitoring
0 – Not applicable 0 – Not applicable
27 28 Control electronics 38 Electric motor type
00 – Not applicable 0 – Not applicable
29 Yoke displacement zone 39 Control voltage
A – Single side of center "A" • • • • x 0 – Not applicable
30 Additional functions 40 41
Customer adjustment specification
42 43
0 – Not applicable
31 Pressure control options
0000 – None • • • • x
0 – Not applicable 44 45 46 Special features
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 13
Model code • Preferred standard option
P * XC - * * * * * * * * * * * * * * * * * * * * HC 8 1 * * * * * * * * * *
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
Form Page
The 48-digit coding system has or special features ( 44 to 46 ) Explanation for each character Codes
been developed to identify all are needed, please provide the
configuration options for the “X” information when ordering.
Basic Pump Model Code 1 to 23
series (Open Loop) fixed and
For combination units, you may Control Options 24 to 39
variable displacement pumps.
need to provide an additional
The Model Code lets you specify
model code. In such a case, each Customer Adjustment Specification 40 to 43
a unit with the desired features.
single pump section must be
All 48 digits must be present Special Features 44 to 46
specified separately using this or
when ordering.
other Eaton catalog information.
You may wish to photocopy the Where characters are already
Design Number 47 & 48
matrix below to ensure that each stated in the blank Model Code,
number is entered in the correct there is no option available.
Combination Units Model Code 1 to 39
box. If adjustments other than
the standard setting ( 40 to 43 )
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
P X –
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
14 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump specifications
Metric
Hydraulic characteristics
Rated pressure (100% duty cycle) pN bar 350
Inlet pressure p1min 0.85 abs 0.85 abs 0.95 abs 0.95 abs 1.0 abs
bar
p1max 10 10 10 10 10
Max. pressure to ISO 5598:2008 p2max bar 420
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See fluid recommendations in application data
Hydraulic fluid temperature range min -25 (on start up)
ºC
max 90
Viscosity range for continuous operation min 10
cSt
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric Vg cm3/rev 66 90 130 180 250
displacement
Speed range min 150
rev/min
max 1800
Case pressure (over pressure) pcase bar
n = 1200 rev/min 3.5 3.5 3.2 3.2 2.8
n = 1500 rev/min 2.7 2.7 2.5 1.5 2.1
n = 1800 rev/min 2.2 1.2 2.0 2.0 1.7
The differential between case pressure and inlet pressure should not exceed 0,5 bar.
Drive
Driving torque M1single Nm 367 501 724 1002 1392
(pN = 350 bar,Vg at 1500 rev/min, η = 100%)
Power consumption P1single kW 57,8 78,8 113,8 157,5 218,8
(pN = 350 bar, n = 1500 rev/min, η = 100%)
Combination units
Maximum driving torque limited to M1Comb. Nm 2x367 2x501 2x724 2x1002 2x1392
splined shaft only - comb. unit
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 15
Pump specifications
US
Hydraulic characteristics
Rated pressure (100% duty cycle) pN psi 5000
Inlet pressure p1min 12,3 12,3 13,8 13,8 14,5
psi
p1max 145 145 145 145 145
Max. pressure to ISO 5598:2008 p2max psi 6000
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See fluid recommendations in application data
Hydraulic fluid temperature range min -13 (on start up)
ºF
max 194
Viscosity range for continuous operation min 10
cSt
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric Vg in3 4.0 5.5 8.0 11.0 15.3
displacement
Speed range min 150
rev/min
max 1800
Case pressure (overpressure) pcase psi
n = 1200 rev/min 50 50 46 46 40
n = 1500 rev/min 39 39 36 36 30
n = 1800 rev/min 32 32 29 29 24
The differential between case pressure and inlet pressure should not exceed 3,625 psi.
Drive
Driving torque M1single Ibf ft 271 369 534 739 1027
(pN = 5075psi,Vg at 1500 rev/min, η = 100%)
Power consumption P1single hp 77.5 105.5 152.5 211 293
(pN = 5075psi, n = 1500 rev/min, = 100%)
Combination units
Maximum driving torque limited to M1Comb. Ibf ft 2x271 2x369 2x534 2x739 2x1027
splined shaft only - comb. unit
16 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Performance curves
066 & 090 Series
25% -1
η tot (%) 1000 min
100
in
1800 min-1
rev
v/m
104
00
40
re
18
00
15
η=
η=
3
20 40 3 x 10
bar 50 100 200 300 400
20
0 0 psi 725 1450 2900 4350 5800
P2 (bar) 0 100 200 300 350 Operating pressure
P2 (psi) 0 1500 2900 4350 5076
100%
Input torque (Nm)
50%
80
Basic rating life L10 [h]
-1
η tot (%) 25% 1000 min
60 -1
1500 min
in
/m
100
in
rev
v/m
1800 min-1
00
40 104
re
18
00
15
η=
η=
20 40
3x103
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350
psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076
Operating pressure
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 17
Performance curves
130 & 180 Series
100%
Input torque (Nm)
80 50% -1
1000 min
60
1800 min -1
in
/m
100
in
rev
v/m
4
10
00
40
re
18
00
15
η=
η=
20 40 3
3 x 10
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350 psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076 Operating pressure
100%
Input torque (Nm)
80 50%
Basic rating life L10 [h]
-1
25% 1000 min
η tot (%)
60 1500 min-1
in
/m
100
1800 min-1
in
rev
v/m
104
00
40
re
18
00
15
η=
η=
20 40
3x103
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350 psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076
Operating pressure
18 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Performance curves
250 Series
60 1500 min -1
in
/m
100
in
1800 min -1
rev
v/m
104
00
40
re
18
00
15
η=
η=
20 40 3
3x10
20 50 100 200 300 400 bar
0 0 725 1450 2900 4350 5800 psi
P2 (bar) 0 100 200 300 350
Operating pressure
P2 (psi) 0 1500 2900 4350 5076
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 19
Installation and start-up
Caution
Before the pump is started, fill the case through the uppermost
drain port with hydraulic fluid of the type to be used. The case drain
line must be connected directly to the reservoir and must terminate
below the oil level. Once the pump is started, it should prime within
a few seconds. If the pump does not prime, check to make sure that
there are no restrictions between the reservoir and the inlet to the
pump, and that the pump is being rotated in the proper direction,
and that there are no air leaks in the inlet line and connections. Also
check to make sure that trapped air can escape at the pump outlet.
After the pump is primed, tighten the loose outlet connections, then
operate for five to ten minutes (unloaded) to remove all trapped air
from the circuit. If the reservoir has a sight gage, make sure the fluid
is clear – not milky.
20 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Application Data and
Fluid Recommendations
Fluid Type DIN/ISO Rated Maximum Speed (rev/min) Recommended Maximum Bearing Life
Classification Pressure pN Seal Material Operating Tem-
(bar) 130 & 180 cm 250 &360 cm
3 3
500 & 750 cm
3
perature (ºC)
Water Glycol HFC 250 1800 1500 1250 NBR 45 25-100%
HFDR (phosphate ester based) HFDR 350 1500 1200 1000 FKM 60 100%
HFDU (glycol based) HFDU 350 1500 1200 1000 FKM 60 100%
HFDU (ester based) HFDU 350 1800 1500 1250 FKM 60 100%
HEES (synthetic ester) HEES 350 1800 1500 1250 FKM 60 100%
See general specifications for speed limitation depending on displacement.
For HFC operation, bearing flushing is mandatory. Highest speed only recommended at optimized application conditions.
Use Model Code 21 = "C" for seal option, and contact your Eaton Representative for validation.
Seal material can differ on an individual pump depending on specific seal function.
Bearing life with HFC fluid depends significantly on fluid temperature, cleanliness, quality, flushing and application parameters.
Typical values vary between 25% and 100% compared to mineral oil.
Only fluids with fully saturated esters (iodine value <10) should be used.
HFDU and HEES fluids can be used at full ratings, but need to be monitored continuosly to maintain quality and performance. The following
important values should always be checked:
- Water content (<= 500 ppm)
- Fluid cleanliness (18/15/13 per ISO 4406)
- TAN value (no significant change from new oil)
- Viscosity (no significant change from new oil)
- Additives (no significant change from new oil)
Under harsh operation conditions, especially with regard to temperature and water content, ester-based HFDU and HFDR fluids are prone
to hydrolysis, the resulting chemical processes and products of which could damage seals and other pump components. In general, the susceptibili-
ty to temperature and contamination is significantly higher than with standard mineral oils.
In line with Eaton Germany GmbH T&C warranty conditions covering use of HFDR/HFDU/HEES fluids, fluid-related damage is excluded.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 21
Pump dimensions
PVXS-066
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)
Pressure
0 120 185 246 compensator
pilot stage
Pressure
68 X1* compensator
main stage
8 17 L1*
L1* L1*
Stroke limiter
L 50%...100%
of Vmax 320
41.0
Ø40.8 93
CW Ref.(229)
18
Centre bore 90
DIN 332-D
M12
26 4x M10-20
L2* deep B 176
58 35 150 210
302
X
L1* A
Ø125h8
10h9
MA* Ø38k6
L1* L3* B
Visual position indicator
274
351
160
235
27.8 M12-18 Deep 35.7 M12-18 Deep A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
62-1" - 6000 PSI)
Ø25 Ø38 MA – Gauge port system
57.2 B – Inlet port ISO 6162-1 P38M
69.8 pressure G1/4"
(SAE J518 CODE 61 - 1 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M22x1.5 (According
Port A 12.5 Deep
Port B to mounting position use
View X
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.
22 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-066
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)
Pressure
comensator
0 120 185 pilot stage
Pressure
X1* comensator
68 main stage
8 17 L1*
L1* L1*
Stroke limiter
L 50%...100%
of Vmax 320
Centre bore 93
CW
DIN 332-D M12 Ref.(229)
18
90
26 4x M10-20
L2* Deep 176
58 35 150 210
292
L1*
Ø125h8
W40x1.25x10a
DIN 5480
A
B
MA*
L1* L3*
274
351
40 40
160
210
27.8 M12-18 Deep 35.7 M12-24 Deep A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
62-1" - 6000 PSI)
MA – Gauge port system
Ø25 Ø38 B – Inlet port ISO 6162-1 P38M
57.2 69.8 pressure G1/4"
(SAE J518 CODE 61 - 1 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M22x1.5 (According
12.5 Deep
to mounting position use
Port A Port B
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 23
Pump dimensions
PVXS-090
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)
Pressure
0 120 185 246 compensator
pilot stage
Pressure
X1* compensator
68
main stage
8 17 L1*
Stroke limiter L1* L1*
50...100%
L of Vmax
320
93
CW Ref.(229)
41.0
ø40.8 18
Centre bore 90
DIN 332-D M12
B
4x M10-20 176
L2* 26 Deep 210
58 35 150
325
X
L1* A
Ø125h8
10h9
MA*
Ø38k6
L1* L3* B
Visual position indicator
160 274
142.5 117.5 351
24 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-090
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)
Pressure
0 120 185 compensator
pilot stage
X1* Pressure
68 compensator
main stage
8 17 L1*
Stroke limiter L1 L1*
50...100%
L of Vmax
320
Centre bore 93
DIN 332-D M12 CW
Ref.(229)
18
90
4x M10-20
L2* 26 Deep 176
58 35 150 210
292
L1
W 40x1.25x10a
DIN 5480
Ø125h8
B A
MA*
L1* L3*
274
351
44 44
160
210
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 25
Pump dimensions
PVXS-130
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)
Pressure
0 148 229 316 compensator
pilot stage
X1*
Pressure
92 compensator
9 20 L1* main stage
L1 L1*
Stroke limiter
50...100%
of Vmax
CW 377
117
Ref.(229)
54.0 22
53.0
Centre bore
DIN 332-D M12 113
4x M12-26 220
L2* 32 Deep B 260
40
185
82
325 X
306
L2 A
MA* Ø50k6
2x M20-30
DEEP
14h9
Ø160.000
159.937
200
L1* L3* B
224
265 Visual Position indicator
391
471
26 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-130
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)
Pressure
compensator
0 148 pilot stage
229
X1* Pressure
compensator
78 main stage
9 20 L1*
Stroke limiter L1 L1*
L 50...100%
of Vmax
377
Centre bore 117
DIN 332-D M16 CW
Ref.(287)
B 22
113
4x M12-26 200
L2* 32 Deep 260
68 40 185
318
L1
Ø160h8
W50x1.25x
30x38x10a
DIN 5480
A
B
MA*
L1* L3*
341
421
50 65
200
260
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 27
Pump dimensions
PVXS-180
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)
Pressure
compensator
0 148 229 316 pilot stage
X1* Pressure
92 compensator
9 20 L1* main stage L1 L1*
Stroke limiter
L 50...100%
of Vmax
377
117 Ref.
CW
(287)
54.0 22
53.8
Centre
bore DIN 113
332-D M16
L2* 4x M12-26 B
32 deep
82 40 185 220
260
325
306
L1 A
Ø160h8
MA*
2x M20-30 deep
14h9
Ø50 k6
200
224 L1* L3* B
265 Visual position indicator
391
471
31.8 M14-22 deep 50.8 M12-20 deep A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
Ø63 62-1 1/4" - 6000 PSI)
Ø32 MA – Gauge port system
66.7 B – Inlet port ISO 6162-1 P64M
88.9
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A 12.5 Deep
Port B to mounting position use
View X
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.
28 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-180
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)
Pressure
compensator
0 148 229 pilot stage
X1* Pressure
78 compensator
9 20 L1* main stage L1
L1*
Stroke limiter
50...100%
L of Vmax
377
113
4x M12-26
L2* 32 deep
68 40 185 200
260
318
L1
Ø160h8
W50x1.25x30
A 38x10a
B DIN 5480
MA*
50 65
200
260
L1* L3*
341
421
31.8 M14-20 deep 50.8 M12-20 deep
A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
Ø32
Ø63 62-1 1/4" - 6000 PSI)
66.7 88.9 MA – Gauge port system
B – Inlet port ISO 6162-1 P64M
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A Port B 12.5 Deep
to mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 29
Pump dimensions
PVXS-250
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)
Pressure
0 187 281 403 compensator
pilot stage
116 X1*
Pressure
9 25 L1* compensator L1 L1*
main stage
Stroke limiter
L
50...100%
of Vmax
448
146 CW
Ref.
(357)
69.0 26
68.8
Centre bore
DIN 332-D 140
M20
4x M16-32
L2* 41 deep B
105 50 230
276
362
350
x
L1 A MA*
Ø200h8
MA
2x M24-38
deep
18 h9
Ø65 k6
250
280 Visual position L1* L3*
330 B
indicator
505
598
30 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-250
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)
Pressure
0 187 281 compensator
pilot stage
91 X1* Pressure
25 L1* compensator
main stage L1 L1*
Stroke limiter
50...100%
of Vmax
448
Centre bore 146 CW
Ref.
DIN 332-D (357)
M20 26
140
4x M16-32
L2* 41 deep
80 50 230 276
350
362
L1
Ø200h8
W62x1.25x30
x48x10a
A DIN 5480
B
4 MA
96 70
250
325 L1* L3*
429
522
31.8 M14-25 deep 69.8 M16-26 deep A – System pressure port ISO L3 – Oil filling 1 5/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
62-1 1/4" - 6000 PSI)
Ø89 MA – Gauge port system
Ø32 B – Inlet port ISO 6162-1 P89M
66.7 120.7 pressure G1/4"
(SAE J518 CODE 61 - 3 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M33x2 (According to
12.5 Deep
Port B mounting position use
Port A
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 31
Control Options DF
DF000A00
32 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0
213 70
31 Pressure compansator
pilot stage 45
Pressure compansator
main stage
X1* 91
41
93
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.
4
T P
X1
D1 D2 3
P A T X1
MA
A
A – System port
B – Inlet port
1
L1, L2 – Drain port
L3 – Oil filling plug
B L2 L3 L1
MA – Gauge port-system pressure
X1 – Remote port pressure
compensator
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage
4 – Pressure compensator,
pilot stage
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 33
Control Options DF
A10
Pressure compansator 65
213
pilot stage
31 45
Pressure compansator
main stage
X1*
X2* 82
41
5
T P
X1
D2
D1 4
P X1 A T A1
X2
(By customer)
D3
3
P A T X1
A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
2 MA – Gauge port-system pressure
MA X1 – Remote port
pressure compensator
A X2 – Remote port load sense
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator-load
1 B L1 L2 L3 sense stage
4 – Pressure compensator
main stage
5 – Pressure compensator
pilot stage
34 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0F
174 70
31 Pressure comensator 45
main stage
X1*
53
4
T P
X1
D1 D2 3
P A T X1
MA
A – System port
B – Inlet port
L1, L2 – Drain port
1
L3 – Oil filling plug
B L2 L3 L1 MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage
4 – Closing plate
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 35
Control Options DF
A0S
237 70
54 45
Pressure
compensator
pilot stage
Slow upstroke
adjustment Pressure X1* 91
screw compensator
main stage 41
T P
X1
D1 D2
3
P A T X1
MA
A – System port
A B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port
1
pressure compensator
B L2 L3 L1
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage with slow upstroke
adjustment screw
4 – Pressure compensator,
pilot stage
36 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
AA
233 70
90 46
Solenoid valve
Pressure compensator
pilot stage (2-pressure level)
A B 5
P T
4
A B TP
X1
D1 D2 3
P A T X1
A – System port
B – Inlet port
2 L1, L2 – Drain port
MA L3 – Oil filling plug
MA – Gauge port-system pressure
A
X1 – Remote port
pressure compensator
1 – Basic pump
1 2 – Connection plate for DF-control
B L2 L3 L1 3 – Pressure compensator,
main stage
4 – Pressure compensator,
pilot stage (Dual relief function)
5 – 4/2 Directional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 37
Control Options DF
AB
233 70
90 46
Solenoid valve
Pressure compensator
pilot stage (2-pressure level)
175
Pressure compensator
main stage
X1*
81
41
A B
a b 5
P T
4
A B TP
X1
D2
3
P A T X1
A – System port
2 B – Inlet port
L1, L2 – Drain port
MA
L3 – Oil filling plug
A
MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 1 – Basic pump
B L2 L3 L1 2 – Connection plate for DF-control
3 – Pressure compensator
main stage
4 – Pressure compensator
pilot stage (Dual relief function)
5 – 4/3 Directional control valve
38 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0_ _ _ _ _100H
268
86 134
Pressure compensator
pilot stage
Venting valve
154
Pressure compensator 124
main stage
X1* 74
41
A B
6 5
T P
D3 D4
4
B A T P
X1
D1 D2 3
P A T X1
A – System port
B – Inlet port
2 L1, L2 – Drain port
MA L3 – Oil filling plug
A
MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 – Basic pump
1 2 – Connection plate for DF-control
B L2 L3 L1 3 – Pressure compensator,
main stage
4 – Intermediate plate
5 – Pressure compensator,
pilot stage
6 – Venting valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 39
Control Options LR
General Description The power hyperbola can be Maximum pump flow can be This solution is also
Energy-saving hydraulic drives continuously adjusted between limited mechanically to between recommended for severe
are possible with pressure Pmin and Pmax, Pmin is given by the 50% and 100% by a screw. As operating conditions and the
compensated and/or power minimum setting of the control an additional option, maximum need for high repeatability over a
controlled pumps, especially main stage (20bar approx.) and (or minimum) flow can also be long period of time. The setting
in combination with the power loss of the pump. limited by a spacer inside the must be defined before ordering
loadsensing option. control cylinder (Model Code since it cannot be modified
Both controller types can be position 13 options 4, 5 or 6, in operation.
LR controls combined with another or with in combination with customer
additional options; for available adjustment specified in positions
The typical p/Q curve is a options, see Model Code.
hyperbola. For constant speed, 40 to 43 ).
the drive torque, i.e. the power
used, is held constant.
40 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A20 size 066-180
213
143 70
31 Pressure compensator 45
pilot stage
Pressure and power
compensator main
stage
X1* 91
41
Power compensator
pilot stage
82
162
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.
T P
X1
D2
D1 3
P A T X1
X1
A – System port
5 B – Inlet port
L1, L2 – Drain port
MA 2 L3 – Oil filling plug
MA – Gauge port-system pressure
A
X1 – Remote port pressure com-
pensator
1 1 – Basic pump
2 – Connection plate for LR-control
B L2 L3 L1
3 – Pressure and power
compensator main stage
4 – Pressure compensator
pilot stage
5 – Power compensator pilot stage
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 41
Control Options LR
A20 size 250
213
143 70
31 Pressure compensator
pilot stage 45
Pressure and power
compensator main stage
X1* 91
41
Power compensator
pilot stage
106
357
194
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.
T P
X1
D2
D1 3
P A T X1
X1
5
A – System port
MA 2 B – Inlet port
L1, L2 – Drain port
A L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure com-
pensator
1 1 – Basic pump
2 – Connection plate for LR-control
B L2 L3 L1
3 – Pressure and power
compensator main stage
4 – Pressure compensator pilot
stage
5 – Power compensator pilot stage
42 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A2F size 066-180
174
143 70
Pressure and
31 power compensator 45
main stage
X1*
53
Power compensator
pilot stage
82
162
4
T P
X1
D2 3
D1
P A T X1
X1
MA 2
A – System port
B – Inlet port
L1, L2 – Drain port
1 L3 – Oil filling plug
MA – Gauge port-system pressure
B L2 L3 L1 X1 – Remote port pressure
compensator
1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power compensa-
tor main stage
4 – Closing plate
5 – Power compensator pilot stage
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 43
Control Options LR
A2F size 250
174
143 70
31 Pressure and power 45
compensator main stage
X1*
53
Power compensator
pilot stage
106
357
4
T P
X1
D2 3
D1
P A T X1
X1
MA 2 A – System port
A B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
1 compensator
B L2 L3 L1 1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power
compensator main stage
4 – Closing plate
5 – Power compensator pilot stage
44 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A30 size 066-180
213
143 Pressure compensator 65
pilot stage 45
31
Pressure and power
compensator main stage
Load sensing valve
X1 131
X2* 82
41
Power compensator
pilot stage
82
162
5
TP
X1
4
D2
D1
P X1 AT A1
X2
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 45
Control Options LR
A30 size 250
213
143 Pressure compensator 65
31 pilot stage 45
Pressure and power
compensator main stage
X2* 82
41
Power compensator
pilot stage
106
5
TP
X1
D2 4
D1
P X1 A T A1
X2
(By customer)
D3
3
P A T X1
X1 A – System port
B – Inlet port
L1, L2 – Drain port
T L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure com-
pensator
6
X2 – Remote port load sense
MA 2
1 – Basic pump
A
2 – Connection plate for LR-control
3 – Pressure compensator-load
sense stage
4 – Pressure and power compensa-
1 B L1 L2 L3 tor main stage
5 – Power compensator pilot stage
6 – Power compensator pilot stage
46 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
General Description signal to apply the required an additional option, of time. The setting must be
The energy-saving setting, resulting in a maximum (or minimum) flow defined before ordering since it
electrohydraulic displacement highly accurate dynamic can be set by a spacer inside cannot be modified in operation.
control type ST efficiently control system. the control cylinder (Model ST control will replace old SP
adjusts pump output by acting Hysteresis is approximately 1% Code position 13 , options control type for PVX pumps.
on the swashplate within of end value. The ST control can 4, 5 or 6, in combination with
customer adjustment specified ST-control requires a min.
electrically adjustable limits. The also be combined with operation pressure of
swashplate angle value is fed hydromechanical relief valves for in positions 40 to 43 ).
>25 bar for operation. Below
back to the controller unit via an pressure and/or power control. This solution is recommended this min. pressure value
electrical closed loop system. Maximum pump flow can be for severe operating conditions pump will automatically go on
A proportional valve and servo limited mechanically to between and the need for high max. displacement.
piston use the controller output 50% and 100% by a screw. As repeatability over a long period
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 47
Control Options ST
STC03A00
258
129 46
75
A B
3
P T
P A T B
A
MA
1
A – System port
B L2 L3 L1 B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
1 – Basic pump
2 – Connection plate
3 – Proportional control valve
48 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A40
258
46
117
X1*
Pressure limiter
override pilot stage Pressure limiter
171
override main stage
85
A B
6
P T
P A T B
3
5
P T D1
A 4
D2
T
P
X1
PA T X1 X1
A – System port
B – Inlet port
2 L1, L2 – Drain port
L3 – Oil filling plug
A MA – Gauge port-system pressure
MA X1 – Remote port pressure
limiter override
1 – Basic pump
1 2 – Connection plate
B L2
3 – Connection plate for ST-control
L3 L1
4 – Pressure limiter override
main stage
5 – Pressure limiter override
pilot stage
6 – 4/3 Directional control valve
7 – Proportional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 49
Control Options ST
STC03A4F
258
117 46
X1*
171
Pressure limiter
override main stage
85
77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 228
...* Connection with plug.
A B
6
P T
P A T B
3
T P D1
A 4
D2
T
P
X1
P A T X1 X1
A – System port
2 B – Inlet port
L1, L2 – Drain port
A
MA L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
limiter override
1 1 – Basic pump
B L2 L3 L1 2 – Connection plate
3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Closing plate
6 – Proportional control valve
50 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A4K
258
117 46
X1*
Propotional 171
relief valve Pressure limiter
override main stage
85
77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 228
...* Connection with plug.
A B
6
P T
P A T B
3
5
T P D1
A
4
D2
T
P
X1
P A T X1 X1
A – System port
B – Inlet port
2 L1, L2 – Drain port
L3 – Oil filling plug
A MA – Gauge port-system pressure
MA
X1 – Remote port pressure
limiter override
1 – Basic pump
1 2 – Connection plate
B L2 L3 L1 3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Proportional relief valve
6 – Proportional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 51
Control Options ST
STC03A4K_ _ _ _C
258
117 46
XP
X1* 211
Propotional
relief valve Pressure limiter override
125
main stage
85
XP External pilot pressure(option VIA no retun valve)10L ACC. DIN EN ISO 8434-1
77
X1 Remote port pressure limiter override. G 1/4”-12.5 Deep 228
...* Connection with plug.
A B
6
P T
P A T B
7 Xp
P A T B
5 3
T D1
4
D2
P
X1 A – System port
P A T X1 X1
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
limiter override
XP – External pilot pressure
2
1 – Basic pump
A 2 – Connection plate
MA 3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Proportional relief valve
1 6 – Proportional control valve
B L2 L3 L1
7 – Adaptor block for pilot
oil option
52 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A4B
298
157 46
Pressure limiter
override pilot stage Proportional control valve
(2-pressure level)
A B
7
P T
6 5 P A T B
B 3
b
B T
T P D1
A P
A
4
a A D2
P
X1
P A T X1 X1
A – System port
A
B – System
Inlet portport
L1,
B L2 – Drain port
Inlet port
L1, L2
L3 – Drain
Oil portplug
filling
MA
L3 – Gauge port-system
Oil filling plug pressure
2 MA
X1 – Gauge port-system
Remote port pressurepressure
A X1 – limiter
Remoteoverride
port pressure
MA limiter override
1 – Basic pump
21 – Basic pump plate
Connection
32 – Connection plate for ST-control
43 – Connection
Pressure andplate
powerfor limiter
ST-control
1 4 – override
Pressure main stage limiter
and power
B L2 L3 L1 5 – Pressure limiter
override main override pilot
stage
5 – stage
Pressure(Duel reliefoverride
limiter function)pilot
6 – stage
4/3 (Duel relief
Directional function)
control valve
76 – Proportional
4/3 Directional control valve
control valve
7 – Proportional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 53
Control Options ST
STC03A4L
258
117 46
X1*
Pressure limiter
override pilot stage 171
Pressure
(Proportional limiter
relief valve) override main 85
stage
77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 257
...* Connection with plug.
A B
6
P T
P A T B
3
5
T P D1
A 4
D2
T
P
X1
PA T X1 X1
A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
2
MA – Gauge port-system pressure
A X1 – Remote port pressure
MA limiter override
1 – Basic pump
2 – Connection plate
3 – Connection plate for ST-control
B
4 – Pressure limiter override
L2 L3 L1
main stage
5 – Pressure limiter override
pilot stage (Proportional relief
valve + OBE)
6 – Proportional control valve
54 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A50
258
117 46
X1*
Pressure
limiter override Pressure and 171
pilot stage power limiter
override main stage 85
Power limiter
override pilot stage
72
A B
7
P T
P A T B
5 3
T P
D1
A 4
D2
T
P
X1
P A T X1 X1 A – System port
X1
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
T
X1 – Remote port pressure
6 limiter override
1 – Basic pump
2 – Connection plate
A 2 3 – Connection plate for ST-control
MA 4 – Pressure and power limiter
override main stage
5 – Pressure limiter override
pilot stage
1 6 – Power limiter override
B
pilot stage
L2 L3 L1
7 – Proportional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 55
Control Options ST
STC03A5F
258
117 46
X1*
171
Pressure and power limiter
override main stage
85
Power limiter
override pilot stage
72
312
A B
7
P T
P A T B
5 3
T P D1
A
4
D2
T
P
A – System port
X1
P A T X1 X1 B – Inlet port
X1 L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
T X1 – Remote port pressure
6 limiter override
1 – Basic pump
2 – Connection plate
A 2
MA 3 – Connection plate for ST-control
4 – Pressure and power limiter
override main stage
5 – Closing plate
1 6 – Power limiter override
B L2 L3
pilot stage
L1
7 – Proportional control valve
56 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A5K
258
117 46
Proportional X1*
relief valve 171
Pressure and power
limiter override
main stage 85
Power limiter
override pilot stage
72
A B
7
P T
P A T B
5 3
T P D1
A 4
D2
P T
X1 A – System port
P A T X1 X1
B – Inlet port
X1
L1, L2 – Drain port
L3 – Oil filling plug
T MA – Gauge port-system pressure
6 X1 – Remote port pressure
limiter override
1 – Basic pump
A 2 2 – Connection plate
MA
3 – Connection plate for ST-control
4 – Pressure and power limiter
override main stage
1 5 – Proportional relief valve
6 – Power limiter override
B L2 L3 L1
pilot stage
7 – Proportional control valve
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 57
Control Options ST
STC03A5L
258
117 46
X1*
Pressure limiter
171
override pilot stage Pressure and power
(Proportional limiter override
relief valve) 85
main stage
Power limiter
override pilot stage
72
A B
7
P T
P A T B
5 3
P D1
A 4
D2
P T
X1
PA T X1 X1
X1
A – System port
B – Inlet port
T L1, L2 – Drain port
6 L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
A 2 limiter override
MA
1 – Basic pump
2 – Connection plate
1
3 – Connection plate for ST-control
4 – Pressure and power limiter
B L2 L3 L1 override main stage
5 – Pressure limiter override pilot
stage (Proportional relief
valve + OBE)
6 – Power limiter override
pilot stage
7 – Proportional control valve
58 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options FM
FM000A0
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 59
Control Options FM
FM000A0
77
23 45
37
93
3
P A T X1
MA
A – System port
B – Inlet port
1 L1, L2 – Drain port
L3 – Oil filling plug
B L2 L3 L1
MA – Gauge port-system pressure
1 – Basic pump
2 – Connection plate for FM-con-
trol
3 – Adaptor plate
60 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ZP
ZP100A0
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 61
Control Options ZP
ZP100A0
155 46
42
39
93
A 4
P T
P A T B 3
MA
A
A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
1 MA – Gauge port-system pressure
B L2 L3 L1 1 – Basic pump
2 – Connection plate for ZP-control
3 – Stroke speed adjustment
control valve
4 – Directional control valve
62 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options SP
General Description A proportional valve and As an additional option, This solution is recommended
The energy-saving servo piston use the controller maximum (or minimum) flow for severe operating conditions
electrohydraulic displacement output signal to apply the can be set by a spacer inside and the need for high
control type SP efficiently required setting, resulting the control cylinder (Model Code repeatability over a long period
adjusts pump output by acting in a highly accurate dynamic position 13 , options 4, 5 or 6, of time. The setting must be
on the swashplate within control system. in combination with customer defined before ordering since it
electrically adjustable limits. The adjustment specified in positions cannot be modified in operation..
Hysteresis is approximately 1% 40 to 43 ).
swashplate angle value is fed of endProportional
value. The SP control Filter with el.
back to the controller unit via an can also be valve
control combined with and optical
electrical closed loop system. contamination
hydromechanical relief valves for
indicator
pressure control.
Pilot pressure
relief valve
A B C
SPC03A
C
Proportional Filter with el.
control valve and optical
contamination
indicator A
A B
6 Pilot pressure
P T relief valve
A P T B
2
1 5
3
B
A P T B
4
A P T B
A MA T1
Pst1
Mst
A
EATON Hydrokraft 3
W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 63
Pst2
A B
6
2 P T
A
Control Options SP
SPC03A
A B A – System port
6
P T B – Inlet port
A P T B L1, L2 – Drain port
L3 – Oil filling plug
2
1 5 MA – Gauge port-system pressure
3
Pst1 – Ports for pilot pump B
A P T B Pst2 – Pilot pump outlet port
4 Mst – Gauge port- pilot pressure
A P T B T1 – Return line of control circuit
T1 (optional)
A MA
Pst1 S – Inlet of pilot pump
Pst2
2
A
B L2 L3 L1
64 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ES
Available to special order only.
General Description A potentiometer for stepless with the result that once the
This unit is used for flow adjustment and/or position control is specified and built,
adjustment. It has a 3-phase monitoring is also available. response time are not variable in
electric servo-motor, worm- Response times from zero to operation. Explosion Protection
gear and a switchbox with 4 or maximum depend on the ratio versions are also available.
(optional) 8 limit switches for selected and on the (fixed)
speed of the servo-motor, No Pressure/Power
different positions. Limiter possible!
A B C
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 65
2
Control Options ES Electric motor for
ESN00A00
displacement control
B
A – System port
B – Inlet port
M
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
2
1 – Basic pump
2 – Electric motor and limit switch
for ES-control
MA
B L2 L3 L1
66 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
General Dimensions
PFXS-066
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 19 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)
0 26 120 246
16
68
8 L1.1* B
CW
223
41.0 18 160
40.8
Centre bore
Din 332-D M12 80
4X M10- 20 176
Deep
58 35 150
210
L2* L1 L3* A
MA*
10h9
125.000
Ø124.937
Ø38K6
120 L1.1*
B
175 274
299
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 67
General Dimensions
PFXS-090
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)
0 26 120 247
16
68
8 L1.1* B
CW
223
41.0 18 160
40.8
Centre bore 80
Din 332-D
M12
4X M10- 20 176
Deep
210
58 35 150
218
L2* L1 L3* A
MA*
10h9
125.000
Ø124.937
Ø38K6
120
L1.1* B
112.5 87.5 275
305
68 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
General Dimensions
PFXS-130
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)
19
92 L3*
B
CW
L1 263
54.0 22 200
53.8
306 A
MA*
14h9
Ø160.000
159.937
Ø50K6
413
A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical mount-
50.8 M12-20 Deep P25M (SAE J518 CODE 62-1" - ing G 1/4"-(Shaft upward)
27.8 M12-20 Deep 6000 PSI) L3 – Oil filling plug 1 1/6"-12UNF
B – Inlet port ISO 6162-1 P64M (SAE MA – Gauge port system pressure
Ø63 J518 CODE 61 - 2 1/2" 500 PSI) G 1/4"
Ø25
L1 – Drain port M26 x 1.5 (According to ...* – Connection with plug
57.2 88.9
mounting position use upper port)
Port A Port B
View X
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 69
General Dimensions
PFXS-180
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)
19
92 L3*
9
B
CW
L1
263
54.0 22 200
53.8
4x M12-20 220
Deep
260
82 40 185
306 A
MA*
14h9
Ø160.000
159.937
Ø50K6
413
50.8 M12-20 Deep A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical
31.8 M14-22 Deep
P32M (SAE J518 CODE 62 - 1 mounting G 1/4"- (Shaft upward)
1/4" - 6000 PSI) L3 – Oil filling 1 1/16"- 12 UNF
Ø63 B – Inlet port ISO 6162-1 P64M (SAE MA – Gauge port system pressure
Ø32 J518 CODE 61 - 2 1/2" 500 PSI) G 1/4"
66.7 88.9
L1 – Drain port M26 x 1.5 (According to ...* – Connection with plug
mounting position use upper port)
Port A Port B
View X
70 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Thru-Drive Options
060 and 090 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.
Option illustrated:
14 15 = 0A (SAE A)
9T 16/32 DP
2x M10-20 DEEP
82.62
Ø 82.58
12
106.4 34
47
Option illustrated:
14 15 = 0B (SAE B)
13T 16/32 DP
2x M12-THRU
101.65
Ø 101.62
13
146 22
46
102
Option illustrated:
14 15 = 0C (SAE C)
14T 12/24 DP
2x M16-30 DEEP
127.05
Ø 127.02
181 13
61 17
98
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 71
Thru-Drive Options
130 and 180 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.
Option illustrated:
14 15 = 0A (SAE A)
9T 16/32 DP
2x M10-20 DEEP
82.62
Ø 82.58
12
106.4 34
47
Option illustrated:
14 15 = 0B (SAE B)
13T 16/32 DP
2x M12-THRU
101.65
Ø 101.62
13
146 22
46
102
Option illustrated:
14T 12/24 DP
14 15 = 0C (SAE C)
2x M16-30 DEEP
127.05
Ø 127.02
181 13
61 17
98
72 EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Thru-Drive Options
250 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.
Option illustrated:
14 15 = 0A (SAE A)
82.62
Ø82.58
9
106.4
28
32
Option illustrated:
14 15 = 0B (SAE B)
6 x M12 -25 DEEP 13T 16/32 DP
101.65
Ø101.62
89.8 12
146 16
47
EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020 73
Eaton Eaton Eaton
Hydraulics Group USA Hydraulics Group Europe Hydraulics Group Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 Eaton Building
Eden Prairie, MN 55344 1110 Morges 4th Floor, No. 3 Lane 280 Linhong Rd
USA Switzerland Changning District
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 Shanghai 200335
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 China
www.eaton.com/hydraulics Tel: (+86 21) 5200 0099
Fax: (+86 21) 5200 0400