GK-42 Photoelectric Correction Controller Instruction: One. Summary
GK-42 Photoelectric Correction Controller Instruction: One. Summary
GK-42 Photoelectric Correction Controller Instruction: One. Summary
One. Summary
The core of the correction controller adopts the advanced single chip
microcomputer for centralized control, and the control panel adopts rubber
keys with long service life. The controller can select single eye and double
eye to correct deviation, and the response speed of correction can be set to
effectively reduce the vibration and noise caused by correction. The correction
controller can control the correction of paper, film and other materials with
correction actuator and photoelectric eye, and can be widely used in cutting
machine, printing machine and other mechanical equipment.
GK-42 光 电 纠 偏 控 制 器
GK- 42 EPC CONTROLLER
96.8 mm
速 度
92 mm
SPEED
电 眼 极 性 模 式
ELECT.EYE POLE GENDER MODE
96.8 mm 68 mm 92 mm
GK-42 光 电 纠 偏 控 制 器
GK- 42 EPC CONTROLLER
1 3
2
速 度
6 SPEED 4
5 7
电 眼 极 性 模 式
ELECT.EYE POLE GENDER MODE
8 10 11 12 9
1 Correction output indication: this direction light indicates the output. State of
deviation correction, that is, positive or reverse correction motor.
2 Limit indicator: this indicator light indicates that the correction actuator has
moved to the limit position.
3 Correction response speed: display correction response speed 0-9, 9 is the
fastest.
4 Response speed adjustment button: press the two keys to adjust the response
speed of correction.
5 Eye selection indicator: displays the current selected working mode of the
rectifying controller.
6 Polarity selection indicator: displays the polarity currently selected by the
correction controller, that is, bright action or dark action.
7 Mode selection indicator: displays the correction controller currently selected
in automatic mode or manual mode.
8 To the left click button: press the button to make the controller to the left
correction output.
9 Point to the right button: press the button to correct the controller to the right
output.
10 Eye selection button: press the button to select the single eye or double eye
working mode, the user according to the material reasonable choice, at the
same time The indicator 5 indicates the current state.
11 Polarity selection button: press this button to switch correction polarity, that is,
change the output direction of correction motor. At the same time, the indicator
6 indicates the current state.
12 Mode selection button: press this button to select the controller automatic
correction mode or manual mode at the same time The indicator 7 indicates
the current state.
Five. Wiring diagrams:
Right
manual/auto
Limit alarm
Buzzer
Left
Synchronous motor
Limit alarm limit switch
R
Relay
limit switch
C
sensor
220V power
sensor
PUSH Fixed
(END)