CONTACTORS

For CAPACITOR SWITCHING

CAPACITOR SWITCHING
CONTACTORS
Type LS KCW

UL / CSA CE
Amp KVAR Rating (UL/CSA) Part
List
Ith Number Price
230V 460V 600V !

25 15 18 LS 12KCW.11-! $109
7.5
32 10 20 25 LS 16KCW.11-! $123
45 12.5 25 30 LS 20KCW.10-! $150
LS12 KCW
45 15 30 35 LS 25KCW.10-! $182
60 20 40 50 LS 30KCW.10-! $246
90 25 55 65 LS 45KCW.10-! $364
110 35 70 80 LS 55KCW.10-! $417
Capacitor Switching

140 45 90 100 LS 70KCW.10-! $535


Includes 1 N.O. Auxiliary Contact, 10 Amp 600Volt except sizes LS12 and LS16
Contactors

!
which have 1 N.O. plus 1 N.C. Auxiliary Contacts.
LS45 KCW
See LS-K Contactor section for additional Aux. Contacts and Accessories

! COIL SUFFIX (Bold type - commonly used coils) For Larger Sizes thru 600KVAR / 1250AMP, use standard LS-K Contactors.
!
AC 60 HZ 50 HZ Check with main office for specific P.F. Switching Ratings.
-G 24V 24V
-A 120V 110V
Complete Part # Example: LS12KCW.11-A
-B 208V 200V
-C 220V 220V
-H 277V 230V
-E 480V 380V
-F 600V 500V
AEG 58 Discount Schedule ST
CONTACTORS
For CAPACITOR SWITCHING
GENERAL DESCRIPTION
Power Factor Correction Application Solution and Problem Analysis
To correct or improve the power factor, it is necessary to connect capacitors at To reduce the peak current, it is necessary to insert inductances in
certain points of the network. In practice, inductive components including trans- the circuit or to use AEG special contactors types LS “KCW”
designed for this application with a built-in set of current limiting
formers, motors, etc. clearly dominate in electrical networks. So, to reduce the resistance.
amount of reactive power in electrical supplies, it is necessary to connect one The UL/CSA approved KVAR and current ratings on Type LS KCW contac-
or more capacitor banks in parallel to the installation. The reactive energy pro- tors are designed and applied for capacitor switching currents. Additionally,
duced by the capacitors, reduce the amount of reactive power supplied to the there is no derating for adding multi step capacitor banks.
consumers, correcting the power factor, increasing the value of Cos n. P - Active Power (Real Power kW)
Q - Reactive Power (KVAR)
U - Line Voltage
UCC - Short Circuit Voltage (%)

Analysis of Inrush Currents and


Capacitor Currents
The phenomenon to switch capacitors in parallel with an inductive circuit
After power factor correction, for existing installations, an adequate power creates transition current peaks of high frequency (15kHz) which may
factor provides a decrease in voltage drops and joule losses and, an increase reach 180 times the capacitor nominal current.
in the induction motor starting torque without altering its power. For new installa-
tions an adequate power factor is going to decrease the initial investment cost Induction motors
and the required installation kVA. Additionally, certain power companies
provide discounts for power factor correction.
Example of typical power factors
Induction Motors (50%) Load <100kW (125HP) 0.6 - 0.8
>250kW (300HP) 0.8 - 0.9
Discharge lamps 0.4 - 0.6 Single capacitor bank
Incandescent lamps 0.9 - 1
Mercury lamps 0.5 - 0.6
Thyristor drives 0.7
Resistance furnaces 0.9 -1
Electric heater 0.9 -1
Arc Furnaces 0.8
Resistance welding machines 0.8 - 0.9 Multi-step capacitor banks
Induction furnaces 0.2 - 0.6
Power Factor

Capacitor Switching
The total operating power, termed Apparent Power (S), is the result of multi-
plying U x I, however the real power is reduced by a factor COS termed

Contactors
Power Factor. In a three-phase systems, the real power of the circuit, termed
Contactors used to switch capacitor banks must be able to carry
Active Power is expressed as:
the presence of harmonic currents in addition to the nominal cur-
P = U x I x Cos rent (with a permissible coefficient: 1.3 ln) of the capacitor banks.
and by analogy, the Reactive Power is expressed as: According to the capacitor manufacturers, the power capacitors
may be over dimensioned 10% due to the internal capacitor toler-
Q = U x I x Sine ance (permissible coefficient: 1.1 ln). Contactors used for switching
capacitor banks must be rated to carry a thermal current 1.43
The Power Factor represents the relationship between the Active Power times (1.3 ln x 1.1 ln) the nominal current of the capacitor.
and the Apparent Power
Ith = 1.43 x ln
Active Power (kW)
Cos = Therefore, contactors used to switch capacitor banks must:
Apparent Power (kVA) -be able to carry a rated permanent current of 1.43 times the
capacitor bank rated current.
-be able to carry transition peak in rush currents on the making
A system with a low Power -Losses on the system capacitor.
Factor may generate: -Excessive energy consumption The peak of current which must be carried by the contactors
-Oversized installations
decreases with the following conditions:
-circuit inductance are high
-line transformer ratings are low
-the UCC transformer is high
AEG 59
CONTACTORS
For CAPACITOR SWITCHING

LS12 LS16 LS20 LS25 LS30 LS45 LS55 LS70


KCW KCW KCW KCW KCW KCW KCW KCW
Main Circuit (poles)
Rated operational voltage (V) 690 690 690 690 690 690 690 690
Rated insulation voltage according to IEC947 (V) 1000 1000 1000 1000 1000 1000 1000 1000
Rated thermal current (A) 25 25 45 45 60 90 110 140
Max. power utilization 230V (kVAR) 7,5 10 12.5 15 20 25 35 45
UL/CSA 460V (kVAR) 15 20 25 30 40 55 70 90
600V (kVAR) 18 25 30 35 50 65 80 100
Max. peak current (A) 1000 1000 1000 1000 2500 3500 3500 3500
Electrical endurance (Ops.) 280,000 280,000 250,000 250,000 200,000 150,000 150,000 100,000
Max. Ops./hour (Ops./hour) 350 350 350 240 240 200 200 200
Control circuit
Standard voltages 50Hz (V) 24-690 24-690 24-690 24-690 24-690 24-690 24-690 24-690
60Hz (V) 24-600 24-600 24-600 24-600 24-600 24-600 24-600 24-600
Consumption
Coil Pick up (VA) 45 45 48 48 88 191 191 198
Holding (VA) 6 6 7 7 9 15.5 15.5 17
Note: Standard LS/K Contactors are also avaiable with Capacitor Switching Ratings to 1250 Amp, 600 KVAR. Check with main office for specific rating.

Terminal capacity and


tightening torque
Solid, stranded and finely 1x 0.5-2.5 1x 0.5-2.5 Max. 16 Max. 50-4 Max. 50-35
stranded without end sleeve (mm2) 1x 2.5-6 1x 2.5-10 Max. 25-16
AWG wires 1x 20-12 1x 20-8 Max. 6 Max. 2-12 Max. 1
Max. 4-4
Tightening torque 1.6 Nm 2.2 Nm 1.8 Nm 4 Nm 5.6 Nm
15 Lb x in 20 Lb x in 16 Lb x in 35 Lb x in 50 Lb x in

Typical Applications

Multi-step capacitor banks with the same ratings Multi-step capacitor banks with different ratings
Single step capacitor bank (No Derating with use of Type LS/KCW) (No Derating with use of Type LS/KCW Contactors)
Capacitor Switching
Contactors

Contactor Contactors Contactors


Type LS KCW Type LS KCW Type LS KCW

AEG 60
CONTACTORS
For CAPACITOR SWITCHING
Dimensions Type LS Type KCW Technical characteristics LS12 KCW-
LS70 KCW

General
Storage temerature (°C) -50 to +80

(3.25”)
Operation temperature (°C) -25 to +55
(with derating)
(5.4”)
Altitude up to 3.000 m Nominal values
Mounting positions Vertical mounting + 30°

Instantaneous auxiliary contact


blocks
Rated insulation voltage (V) 1000
(3.37”)

Rated thermal current Ith (A) 10

OPERATION DESCRIPTION
(5.5”)
(3.56”)

(5.9”)

Inductive Choke

Capacitor Switching
(4.67”)

On pick-up, Type LS-KCW contactors add, then disconnect,

Contactors
inductive chokes to reduce capacitor inrush currents.
Positive Design Operation
(6.6”)
The key for positive operation is one assembly on one arma-
ture guide, all factory manufactured and 100% tested.
An extra set of line contacts, 3 poles, is part of the main
armature guide. These are designed into the head of the contactor,
along with a current limiting inductance to reduce the inrush. This is
one assembly and part of the contactor. When the contactor is
(5.06”)

turned ON, as the armature closes, the three extra poles are early
make, before the main poles make to reduce the inrush current.
Most important, these early make poles, then mechanically open as
the armature picks up so the main poles only carry the continuous
(7.0”)
current.
All Dimensions are Approx. mm (inch)
AEG 61
TYPE LS-K 3-POLE
AC POWER CONTACTORS

TYPE K CONTACTORS 2 5 A M P TO 1 2 5 0 A M P
K CONTACTORS

M O D U L A R S PA C E S AV I N G

3 POWER POLES

4 POWER POLES
2 POLES N.O./2 POLES N.C.
4 POLES N.O

U.S.A. AND
INTERNATIONAL STANDARDS

UL/CSA

( Full Approvals

( Available Worldwide

( Industry Accepted

( Load Matching & Savings


• With more size selections
Significant Cost Savings result

( AC and DC Coils

MECHANICAL ENDURANCE
15,000,000

CONTACTORS TYPE LS 4K - LS 55K


MODULAR ACCESSORIES Electrical Endurance

• ONE ACCESSORY SET-


LS 15K
LS 18K
LS 22K
LS 30K
LS 37K

COVERS 11 “K” SIZES


LS 11K

LS 45K
LS 55K
LS 4K
LS 5K
LS 7K

LS 4K THROUGH LS 55K.
OPERATIONS

MODULAR ACCESSORIES
• FRONT MOUNT AUXILIARY CONTACTS
• SIDE MOUNT AUXILIARY CONTACTS
• SURGE SUPPRESSION MODULES
• INTERFACE MODULES
• MECHANICAL INTERLOCK KITS
LUV18 FOR LS 4K TO 18K
LUV55 FOR LS 22K TO 55K
• PLUG-ON OVERLOAD RELAYS Utilization catagory AC-1
AEG 62 (TYPE B 27T OR B77S)
TYPE LS-K 3-POLE
AC CONTACTORS

3 N.O. POWER POLES 600 Volt AC

CONTACTORS
3 POLE
Max Horsepower AMPS (600V)

(1 Phase) (3 Phase) Ith UL/CSA Part List K.W. Rating


Voltage Voltage Inductive Number Price Voltage

115 230 200 230 460 600 ! 230 400 500 690
.75 1.5 3 3 5 7.5 25 25 LS4K.10* $90.00 2.2 4 5.5 5.5
.75 2 3 3 7.5 10 25 25 LS5K.10* 115.00 3 5.5 7.5 7.5
1 3 5 5 10 15 32 32 LS7K.10* 138.00 4 7.5 10 10
1.5 3 5 7.5 15 15 45 32 LS11K.10* 153.00 7.5 11 15 15
2 5 10 10 20 25 54 54 LS15K.10* 173.00 9 15 18.5 18.5
3 5 10 10 25 25 55 55 LS18K.11* 204.00 11 18.5 25 30
3 7.5 15 15 40 40 90 80 LS22K.11* 216.00 15 22 30 35
5 10 20 20 50 50 110 100 LS30K.11* 240.00 18.5 30 40 45
5 15 20 25 50 60 110 100 LS37K.11* 300.00 22 37 45 45
7.5 15 25 30 60 75 140 140 LS45K.11* 380.00 25 45 55 55
10 20 30 40 75 75 140 140 LS55K.11* 470.00 30 55 65 65
50 50 125 125 250 156 LS75K.11* 800.00 45 75 100 100
60 60 150 150 250 175 LS90K.11* 1170.00 55 90 110 132
60 75 150 150 315 200 LS110K.11* 1270.00 65 110 132 165
60 75 150 150 315 200 LS132K.11* 1470.00 75 132 160 200
100 100 250 300 400 310 LS160K.11* 1770.00 90 160 200 250
125 150 300 400 600 500 LS220K.22* 2150.00 125 200 300 370
150 200 400 500 700 650 LS280K.22* 3100.00 160 280 400 450
200 250 500 600 1000 810 LS375K.22* 3900.00 220 375 480 500
350 450 900 900 1250 1215 LS450K.22* 7560.00 250 450 500 550

Auxiliary Contacts
Standard Number Maximum Number
Contactor
* COIL SUFFIX (Bold type - commonly used coils) Aux. / Code Aux. / Code

LS4K-LS15K 1N.O. / .10 4 / .40, .22


For LS4K-LS110K (3 pole) For LS132 - LS375K
For LS450K
LS5K-4 to LS90K -4 (4 pole) (3 & 4 pole) LS18K-LS160K 1NO, 1NC / .11 4 / .40, .22
AC 60 HZ 50HZ DC AC/DC 50/60HZ/DC 50/60HZ
LS220K-LS450K 2NO, 2NC / .22 4NO, 4NC / .44
* * (1) * (2) * (3) !Code = First Digit, N.O. Aux.
-G 24V 24V -MSW 12VDC -N 24-28V -A 110-120V = Second Digit, N.C. Aux.
-A 120V 110V -NSW 24VDC -AP 110-127V -C 220-240V
• FOR EXTRA SNAP ON AUXILIARY
-B 208V 200V - - - - -
CONTACTS, SEE “K” ACCESSORY
-C 220V 220V -OSW 48VDC -CR 220-260V -E 360-440V Page AEG 67
-H 277V 230V -PSW 110VDC -EX 440-500V -
-E 480V 380V -RSW 220VDC - - - (1) SW: Add for DC Power Plant,
-F 600V 500V - - - - - (single winding)
LS4K-LS11K.....add $45 List
ALL LS...K Contactors have LS15K-LS22K...add $65 List
SPECIAL RATINGS FOR LIGHTING APPLICATIONS TW; LS30-110K- Add $65 List
Check with factory.
(2) AC/DC: Larger contactors
LS132K-LS375K
have AC/DC
To Add Overload, Refer to Pages AEG 42 & 43 powerplants and are
usable on50/60HZ as
well as DC coil voltage
systems.
(3) LS450K contactor is available
only with AC coil.

Discount Schedule ST AEG 63


TYPE LS-K 4-POLE
AC CONTACTORS

4 N.O POWER POLES (CODE - 4) 600 VOLT AC


K CONTACTORS

2 N.O. & 2 N.C. POWER POLES (CODE - 22)


Max Horsepower AMPS (600V)

(3 Phase) AC-1 UL/CSA Part List K.W. Rating


Voltage Inductive Number Price Voltage

200 230 460 600 230 400 500 690


LS5K-4-* $130.00
3 3 7.5 10 25 25 LS5K-22-* 130.00 3 5.5 7.5 7.5

LS7K-4-* 164.00
5 5 10 15 32 32 LS7K-22-* 164.00 4 7.5 10 10

LS11K-4-* 183.00
5 7.5 15 15 45 32 7.5 11 15 15
LS11K-22-* 183.00
LS15K-4-* 233.00
10 10 20 25 60 54 9 15 18.5 18.5
LS15K-22-* 233.00

LS18K-4-* 284.00
10 10 25 25 90 55 11 18.5 25 30
LS18K-22-* 284.00

LS30K-4-* 419.00
20 20 50 50 110 100 18.5 30 40 45
LS30K-22-* 419.00
20 25 50 60 110 100 LS37K-22-* 484.00 22 37 45 45
25 30 60 75 140 140 LS45K-4-* 506.00 25 45 55 55

30 40 75 75 200 140 LS55K-4-* 720.00 30 55 65 65

50 60 125 125 325 156 LS90K-4-* 1445.00 55 90 110 132

60 75 150 150 400 200 LS132K-4-* 1745.00 75 132 160 200

100 100 200 300 500 310 LS160K-4-* 2395.00 90 160 200 250

125 150 300 400 600 500 LS220K-4-* 2650.00 125 220 300 375

150 200 400 500 700 650 LS280K-4-* 3950.00 160 280 400 450

200 250 500 600 1000 810 LS375-4-* 5400.00 220 375 480 500

350 450 900 900 1250 1215 LS450K-4-* 9450.00 250 450 500 550

NOTE: Above contactors, LS5K - LS55K are supplied without auxiliaries.


* COIL SUFFIX - Select coil from chart on the previous page. Standard
For accessories - see page AEG 67 Auxiliary Contacts
(4-Pole Contactors)
Contactor Standard
Auxiliary
LS4K - LS55K Without
Auxiliary

LS37K-22-A LS90K - LS450K 1N.O., 1 N.C.


4 pole (2 N.O. / 2 N.C., 100 Amp.)
LS450K-4. 11-A
AEG 64 4 pole (N.O., 1250 Amp.) Discount Schedule ST
TYPE LS-K CONTACTORS
TECHNICAL SPECIFICATIONS

K CONTACTORS
LS-K CONTACTORS
FROM LS 4K TO LS 18K
INTERNATIONAL
RATINGS
Type LS 4K LS 5K LS 7K LS 11K LS 15K LS 18K
Style 3 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole
Rated insulation voltage U i Pollution degree 3
V 1000 1000 1000 1000 1000 1000
Rated impulse voltage Uimp kV 6 6 6 6 6 6
Mechanical endurance
AC - operation Operations Mio 15 15 15 15 15 15
DC - operation Operations Mio 15 15 15 15 15 15
Utilization category AC-1 Rated power values at resistive load
Rated power value PN 3~ 230 V kW 9.5 9.5 12 17 22,5 22,5 30
3~ 400 V kW 16.5 16.5 22 29 39,5 39,5 55
3~ 500 V kW 21,5 21,5 27,5 39 52 52 69
3~ 690 V kW 28,5 28,5 38 51 68,5 68,5 95

Rated current /e up to 690 V A 25 25 32 45 60 60 90


Minimum wire cross-section under rated load /e mm! 4 4 6 10 16 16 35
Admissible practical operation frequency ops/h 1200 1200 1200 1200 1200 1200 1200
Rated current at 1000 ops/h A 25 25 32 45 60 60 90
Utilization category AC-3 Rated power values of AC induction type motors
Rated power value PN 3~ 230 V kW 2.2 3 4 7,5 9 11
3~ 400 V kW 4 5,5 7,5 11 15 18,5
3~ 415 V kW 4 5,5 7,5 11 15 22
3~ 500 V kW 5.5 7,5 10 15 18,5 25
3~ 690 V kW 5.5 7,5 10 15 18,5 30

Rated current /e up to 440 V A 9 12 18 25 32 40


Admiss. switching freq. at PN and cont. cycling ops/h 1200 1200 1200 1200 1200 1200
Utilization category AC-4 Rated power values of AC induction type motors
Rated power value PN 3~ 230 V kW 1,1 1,5 1,8 3 3,7 4
3~ 400 V kW 2,2 3 3,7 5,5 7,5 9
3~ 500 V kW 3 4 5,5 7,5 10 11
3~ 690 V kW 4 5,5 7,5 10 11 15

Rated current /e with practical electrical


endurance up to 3~ 440 V A 5 7 8 12 16 18,5
Admissible switching frequency ops/h 360 360 360 360 360 360 200
Maximum permissible load PN 3~ 400 V kW 4 5,5 7,5 11 15 18,5
/e 3~ 400 V A 9 12 18 25 32 40
Utilization category AC-6b Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 µH)
Single / Parallel operation 3~ 230 V kvar 2.5/2.5 3/3 3/3 7/6,5 10 /10!) 12/12!)
3~ 400 V kvar 4 /4 5/5 5/5 13/11 16,7/16!!) 20/20!)
3~ 525 V kvar 4 /4 6/5 6/5 17/13 20 /20!) 25/25!)
3~ 690 V kvar 4 /4 6/5 6/5 17/12,5 19 /16,7!) 20/20!)
DC-switching Rated current /e 3 contacts connected in series (all DC-motors L/R •15 ms)
DC-1 (resistive load) 24 ... 220 V /e A 25 25 25 32 50 50 90
DC-3 / DC-5 24 ... 110 V /e A 15 15 15 20 25 32 60
Admissible switching frequency (DC-1 ... DC-5) 50 50 50 50 50 50 50
Short Circuit protection of main contacts1) Maximum permissible fuse (operating category gL)
Coordination type »2« 25 25 35 50 50 50 63 100
no welding 10 10 25 35 35 35 35 80
Operating coil for AC-operation Standard coil, power consumption at 50 Hz 1,0 Us
Operating range 0,8 ... 1,1 Us Pick-up PAS VA 45 45 45 45 88 88 88 191
COS Ø 0,82 0,82 0,82 0,82 0,76 0,76 0,76 0,54
Holding PHS VA 6 6 6 6 9 9 9 17
COS Ø 0,34 0,34 0,34 0,34 0,31 0,31 0,31 0,26
Operating coil for DC-operation Standard coil, power consumption at 1,0 Us
Operating range 0,8 ... 1,1 Us Pick-up PA W 5,5 5,5 5,5 5,5 7,5 7,5 7,5 197
Holding PH W 5,5 5,5 5,5 5,5 7,5 7,5 7,5 2,6
Switching items at AC-operation Standard coil, power consumption at 1,0 Us
Making delay ms 6 ... 25 6 ... 25 6 ... 25 6 ... 25 7 ... 25 7 ... 25 7 ... 25 9 ... 35
Drop-out delay ms 6 ... 13 6 ... 13 6 ... 13 6 ... 13 5 ... 25 5 ... 25 5 ... 25 9 ... 15
Switching items at DC-operation Standard coil, power consumption at 1,0 Us
Making delay ms 35 ... 65 35 ... 65 35 ... 65 35 ... 65 35 ... 70 35 ... 70 35 ... 70 15 ... 40
Drop-out delay ms 30 ... 60 30 ... 60 30 ... 60 30 ... 60 40 ... 65 40 ... 65 40 ... 65 9 ... 15
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
»2« Slight welding of contacts that can easily be opened, is admitted but no further damages.
2) Minimum inductance between parallel connected capacitor 20 µH
AEG 65
TYPE LS-K CONTACTORS
TECHNICAL SPECIFICATIONS
K CONTACTORS

LS-K CONTACTORS
FROM LS 22K TO LS 55K
INTERNATIONAL
RATINGS
Type LS 22K LS 30K LS 37K LS 45K LS 55K
Style 3 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole 3 pole
Rated insulation voltage U i Pollution degree 3
V 1000 1000 1000 1000 1000
Rated impulse voltage Uimp kV 8 8 8 8 8
Mechanical endurance
AC - operation Operations Mio 15 15 15 15 15
DC - operation Operations Mio 15 15 15 15 15
Utilization category AC-1 Rated power values at resistive load
Rated power value PN 3~ 230 V kW 30 42 42 53 53
3~ 400 V kW 55 72,5 72,5 92 92
3~ 500 V kW 69 95 95 121 121
3~ 690 V kW 95 125 125 160 160

Rated current /e up to 690 V A 90 110 110 140 140


Minimum wire cross-section under rated load /e mm! 35 35 35 50 50
Admissible practical operation frequency ops/h 1200 1200 1200 1200 1200
Rated current at 1000 ops/h A 90 110 110 112 112
Utilization category AC-3 Rated power values of AC induction type motors
Rated power value PN 3~ 230 V kW 15 18,5 22 25 30
3~ 400 V kW 22 30 37 45 55
3~ 415 V kW 25 37 45 50 55
3~ 500 V kW 30 40 45 55 65
3~ 690 V kW 35 45 45 55 65

Rated current /e up to 440 V A 50 65 80 95 105


Admiss. switching freq. at PN and cont. cycling ops/h 1200 1200 1200 1200 1200
Utilization category AC-4 Rated power values of AC induction type motors
Rated power value in PN 3~ 230 V kW 5,5 7,5 10 11 13
3~ 400 V kW 11 15 18,5 22 25
3~ 500 V kW 15 18,5 22 25 30
3~ 690 V kW 18,5 22 25 30 37

Rated current /e with practical electrical


endurance up to 3~ 440 V A 23 30 37 44 50
Admissible switching frequency ops/h 200 200 200 200 200
Maximum permissible load PN 3~ 400 V kW 22 30 37 45 55
/e 3~ 400 V A 50 65 80 95 105
Utilization category AC-6b Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 µH)
Single / Parallel operation 3~ 230 V kvar 17/17 21/21 24/24 28/28 30/30
3~ 400 V kvar 30/30 38/38 40/40 50/50 60/50
3~ 525 V kvar 35/35 50/50 50/50 50/50 80/66
3~ 690 V kvar 40/30 40/40 40/40 40/40 60/50
DC-switching Rated current /e 3 contacts connected in series (all DC-motors L/R • 15 ms)
DC-1 (resistive load) 24 ... 220 V /e A 90 110 110 140 140
DC-3 / DC-5 24 ... 110 V /e A 60 70 70 95 95
Admissible switching frequency (DC-1 ... DC-5) 50 50 50 50 50
()
Short Circuit protection of main contacts( Maximum permissible fuse (operating category gL)
Coordination type »2« 100 125 125 200 200
no welding 80 100 100 160 160
Operating coil for AC-operation Standard coil, power consumption at 50 Hz 1,0 Us
Operating range 0,8 ... 1,1 Us Pick-up PAS VA 191 191 191 191 191
COS Ø 0,54 0,54 0,54 0,54 0,54
Holding PHS VA 17 17 17 17 17
COS Ø 0,26 0,26 0,26 0,26 0,26
Operating coil for DC-operation Standard coil, power consumption at 1,0 Us
Operating range 0,8 ... 1,1 Us Pick-up PA W 197 197 197 197 197
Holding PH W 2,6 2,6 2,6 2,6 2,6
Switching items at AC-operation Standard coil, power consumption at 1,0 Us
Making delay ms 9 ... 35 9 ... 35 9 ... 35 9 ... 35 9 ... 35
Drop-out delay ms 9 ... 15 9 ... 15 9 ... 15 9 ... 15 9 ... 15
Switching items at DC-operation Standard coil, power consumption at 1,0 Us
Making delay ms 15 ... 40 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Drop-out delay ms 9 ... 15 9 ... 15 9 ... 15 9 ... 15 9 ... 15
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages: For technical specifications or larger
»2« Slight welding of contacts that can easily be opened, is admitted but no further damages. K contactors through LS450K (1250A),
request from factory.
AEG 66
TYPE LS-K CONTACTORS
AC CONTACTORS

K CONTACTORS
ACCESSORIES FOR LS-K CONTACTORS
Aux. CATALOG LIST CATALOG LIST
LS4K - LS11K: 4 max Remarks
Remarks NUMBER EACH NUMBER EACH
LS18 - LS55: 6 max
NO/NC Overvoltage suppressor
For direct connection to the coil
Auxiliary switch LK-HS7K.10 $ 12.00 terminals A1/A2 adaptable
For LS4K - LS55K for 1 contact LK-HS7K.01 12.00 without cable. RC -unit
front snap-on mounting. 24 - 48v LK-LR 2K-G $ 28.00
.10 NO LK-HS7V.10 17.00 For AC-operated contactors 50 - 127v LK-LR 2K-A 28.00
.01 NC LK-HS7V.01 17.00 LS 4K - LS 18K 130 - 250v LK-LR 2K-C 28.00

24v LK-LR 3K-G $ 28.00


Auxiliary switch For AC-operated contactor 50 - 127v LK-LR 3K-A 28.00
LK-HS8K.11 $ 22.00 LS 22K - LS 55K 130 - 250v LK-LR 3K-C 28.00
For LS4K - LS450K for 2 contact , for side mounting.
R: For mounting of more than 4 front - or LK-HS8K.20 22.00
2 side mounted auxiliary contacts 24v LK-LR 5K-G $ 28.00
LK-HS8R.11 22.00
.11 N.O., N.C., .20 2N.O. (Rating A600, 10 AMP) For AC-operated contactors 48 - 260v LK-LR 5K-A 28.00
LK-HS8R.20 22.00 LK-LR 5K-D
LS4K-55K: only one each side. LS90-450K: two per side LS 220K - LS 450K 80 - 415v 28.00

DC - auxiliary switches For DC-operated contactors Diode


For LS22K - LS55K switching 2-winding LS 4K - LS55K 12 - 600v LK-LDK-R $ 28.00
LK-HS8G.10 $ 20.00
DC coil.
See also spare coils For AC- or DC- Varistor
Mechanical Latch LK-WBK-* $ 71.00 operated contactors 24 - 48v LK-LV 3K-GN $ 28.00
For 1 contact, front For LS4K - LS55K LS 4K - LS 55K 50 - 127v LK-LV 3K-AP 28.00
snap-on mounting 130 - 250v LK-LV 3K-CR 28.00
with electric impulse
or manual. AC VOLT DC VOLT
Interface module For LS 4K
For LS4K - LS55K directly through
-G 24 - 32 -N 24 - 36 parallel to the coil terminals LS 55K
-X 48 - 60 -O 42 - 48 A1/A2 adaptable without cable With relay
-A 110 - 127 -P 110 - 125
-C 208 - 277 -R 220 - 250 24v LK-IM (RD) $ 85.00
-E 380 - 480 48v LK-IM (RME) 85.00
-F 600 Operation by relay
or directly
24v LK-IM 2K(RDM) $ 110.00
Timer 110.00
48v LK-IM 2K(RME)
For LS4K - LS55K pneumatic, contacts,
Via semi-conductor
pneumatically delayed auxiliary switches. ON-Delay
24v LK-IM 3K(SD) $ 110.00
(Rating A600, 10 AMP) 0,1 - 30s LK-TMD 30 $ 115.00
1 - 60s LK-TMD 60 120.00 Switch module and
* Allows coils from 24-240VAC direct switching
OFF-Delay to ber operated using either 24 possible
0,1 - 30s LK-TMI 30 115.00 24 - 100v LK-IM 4K(MJ) $ 140.00
120.00 or 48VDC with low current.
1 - 60s LK-TMI 60 100 - 250v LK-IM 4K(MR) 140.00
Electronic TImer For LS 4K - LS 55K directly ON-Delay
parallel to the coil terminals 0,1 - 2s LK-TED 2 (TRLEC02) $ 120.00
A1/A2 adaptable without cable. 1,5 - 30s LK-TED 30 (BTLEC30 115.00
OFF-Delay
0,1 - 2s LK-TEI 2 (BTLED02) $ 120.00
1,5 - 30s LK-TEI 30 (BTLED30) 115.00
Mechanical Interlock FOR: Mechanical
For side mounting LS 4K - LS 18K LK-LUV 18K $ 33.00
LS 22K - LS 55K LK-LUV 55K 33.00

Mechanical / Electric
LS 4K - LS 18K 2 N.C. contacts LK-LUV 18E $ 48.00
LS 22K - LS 55K 2 N.C. contacts LK-LUV 55E 48.00
Mechanical, contact mounting horizontally
LS75K - LS375K LK-LUV 375H $ 70.00
LS230K - LS280K (only available as horizontal mount)
Mechanical, contact mounting vertically
LS 220K - LS 375K LK-LUV 375V -
LS 450K LK-LUV 450V -
Device marking parts For LS 4K - LS 450K for
designation and marking.
Marking system
Label carries 10 leafs LK-SPR
with 260 labels each LK-EAT-260

Mounting Plate FOR: TO: With mounting rail contour to


DIN EN 50 022
Use when replacing LA-contactors by LS 4 - LS 17 LS 4K - LS 7K
LS...K -contactors (LS 4 - LS 17), LS27, LS37 LS 4K - LS18K LK-AD 18
-Mounting aid for individual rail
mounting of LS...K -contactors LS 47 - LS 87 LS 22K - LS 45K LK-AD 45

LS 107 LS 55K LK-AD 55

Discount Schedule ST AEG 67


REPLACEMENT COILS &
CONTACT KITS (“K” SERIES)

SPARE PARTS AC COILS DC COILS


Replacement Coils Catalog List Coil Volt-Amp Catalog List Pick-up Holding
Contactor Number Each Pick-up Holding Number Each Watt Watt
Type VA VA

LS05 LK-C 130-* $20.00 26 4 LK-C 133-* $25.00 2.4 2.4


(at 24V) (1.2w) (1.2w)

LS 4K 3 + 4 pole LK-C 650-* $23.00 45 6 LK-C 660-* $50.00 5.5 5.5


LS 5K 3 + 4 pole
LS 7K 3 + 4 pole
LS 11K 3 pole

LS 11K 4 pole LK-C 652-* $28.00 88 9 LK-C 662-* $73.00 7.5 7.5
LS 15K 3 + 4 pole
LS 18K 3 pole

LS 18K 4 pole LK-C 653-* $52.00 191 17 LK-C 663-* $112.00 197 2.6
LS 22K 3 pole TW -
LS 30K-45K 3 + 4 pole Two winding
LS 55K 3 pole
SPARE PARTS “K” CONTACTORS

LS 75K 3 pole LK-C 654-* $90.00 Spare Contacts


LS 90K 3 pole
REPLACEMENT CONTACTS
Kit includes 2 stationary & 1 movable
LS 55K 4 pole contact for each pole with spring.
LK-C 655-* $90.00
LS 110K 3 pole

LS 90K 4 pole LK-C 656-* $90.00

AC/DC CONTACTOR COILS 3 Pole Kits 4 Pole Kits (-22 or -4)


Contactor Catalog List Contactor Catalog List
Replacement Coils Catalog List Type Number Each Type (-22 or-40) Number Each
Contactor Type Number Each
LS 4K LK-CS 4-3P $29.00 LS 5K-22 or 40 LK-CS 5C-* $40.00
LS 75K 3 pole LS 5K LK-CS 5-3P 30.00 LS 7K-22 or 40 LK-CS 7C-* 53.00
LK-C 665-* $90.00
LS 90K 3 pole LS 7K LK-CS 7-3P 40.00 LS11K-22 or 40 LK-CS 11C-* 65.00
Power Pack LS 11K LK-CS 11-3P 43.00 LS15K-22 or 40 LK-CS 15C-* 90.00
LK-CM 672-* $445.00
LS 15K LK-CS 15-3P 62.00 LS18K-22 or 40 LK-CS 18C-* 108.00
LS 18K LK-CS 18-3P 72.00 LS 30K-22 or 40 LK-CS 30C-* 165.00
LS 110K 3 pole LK-C 667-* $90.00 LS 22K LK-CS 22-3P 100.00 LS 37K-22 or 40 LK-CS 37C-* 260.00
LS 160K 3 pole LS 30K LK-CS 30-3P 108.00
LS 375K 3 pole Power Pack LS37K LK-CS 37-3P 136.00
LS 55K 4 pole LK-CM 671-* $445.00 * = Specify
LS 45K LK-CS 45-3P 172.00
LS 55K LK-CS 55-3P 208.00 -22 or
-40
LS 90K 4 pole LK-C 670-* LS 75K LK-CS 75-3P 229.00
$238.00
LS 132K 4 pole LS 90K LK-CS 90-3P 287.00
LS 160K 4 pole Power Pack LS 110K LK-CS 110-3P 363.00
LS 375K 4 pole LK-CM 670-* LS 132K LK-CS 132-3P 433.00
$445.00
LS 160K LK-CS 160-3P 543.00
Coil with
LS 220K LK-CS 220-3P 860.00
Power Pack
LS 280K LK-CS 280-3P 1240.00
LS 220K 3 + 4 pole
LS 375K LK-CS 375-3P 1475.00
LS 280K 3 + 4 pole LK-C 669-*
$576.00 LS 450K LK-CS 450-3P 2675.00
LS 450K * 3 + 4 pole
DIMENSIONS, Approximate mm (inch) AC OPERATED
LK-C 668-*
* AC ONLY $238.00 Contactor LS 4K, 5K LS 11K-4 LS 22K LS 45K LS 18K-4 LS 45K-4
Part Number LS 7K, 11K LS 15K-4 LS 30K LS 55K LS 30K-4
* C O I L V O LTA G E S U F F I X 3 pole 11K = 3Pole LS 15K LS 37K LS 37K-4
(-4 is 4 pole) (3 + 4 pole) LS 18K (3 pole) (3 pole) (4 pole) (4 pole)
S E E PA G E A E G 6 3
Height 81 (3.2”) 87 (3.4”) 117 (4.6”) 117 (4.6”) 117 (4.6”) 117 (4.6”)
Width 45 (1.8”) 55 (2.2”) 66 (2.6”) 75 (3”) 87 (3.4”)* 96 (3.8”)*
* DC OPERATED same dimensions, except with Depth 83 (3.3”) 98 (3.9”) 116 (4.6”) 126 (5.0”) 118 (4.6”) 126 (5.0”)
Add for
DC coil switching auxiliary, and 11 mm (0.43”) top auxiliaries + 29 (1.2”) + 29 (1.1”)
AEG 68 Discount Schedule RP
TYPE LS CONTACTOR
SPARE PARTS

ENCLOSURES FOR STARTERS, CONTACTORS, RELAYS


TYPE M01 NEMA 4X TYPE S4
SIZE AEG PART NUMBERS GENERAL PURPOSE LIST DUST/WATER TIGHT LIST DUST TIGHT/OUTDOOR LIST
METAL NON-METAL NON-METAL

SP’s XSP4-27 M01 070405-WR* $35 S4X-RVJ 1008-WR* $125 S4-H 356-WR* $47
(relays) SH04, 17 (4 Pole only) M01 070405 32 S4X-VJ 606 95
(contactors) LS07, 05, 4, 7, 17
(relays) SH8, SH17 (6-8 Pole) M01 070405 32 S4X-RVJ 1008 122
(contactors) LS27, 37 S4 (OUTDOOR IP66 PACKAGE)
(mini starters) XLS07 M01 070405-WR* 35 S4X-VJ 606-WR* 98 S4-H356-WR-KSS-3
LIST EACH $62
00, 0, 1+ (starters) XLS4, 7, 17, 27 M01 070405-WR* 35 S4X-RVJ 1008-WR* 125
2, 21/2 (contactors) LS47, 57 M01 110806 57 S4X-RVJ 1008 122 4X (OUTDOOR 4X, 3R, 12, 13)
(reversing starters) RXLS4, 7, 17 M01 110806-WR* 60 S4X-RVJ1008-WR 125 UL/CSA
(x-line starters) XLS37, 47, 57 M01 110806-WR* 60 S4X-RVJ 1210-WR 156 RVJ1008-WR-KSS3
(reversing starters) RXLS27, 37 LIST EACH $140
3, 31/2 (contactors) LS77, 87 M01 161208 160 S4X-RVJ 1412 200
NOTE: above packages include
(x-line starters) XLS77, 87, 107 M01 201608-WR* 190 S4X-VJ1816-WR* 231 through door reset outdoor
(reversing starters) RXLS47, 57, 77 start/stop operator, back plate with
(reversing starters) RXLS87, 107 M01-242008 200 S4X-AN2416-WR* 500 drillings for the following starters:
XLS-XSP, 07, 4, 7, 17, 27
4, 41/2 XLS177 M01 242010-WR* 300 S4X-AN 2416-WR* 500
(x-line reversing) RXLS177
5 XLS247, RXLS247 M01 302412-WR* 425 S4X-AN 3325-WR* 770

*WR-Suffix “WR” indicates “with reset” and is supplied with drilling, hardware (or rail), and reset for fast mounting of starter units.

SPARE PARTS
SPARE COILS DC COIL-SINGLE WINDING (SW)
AC COIL DC COIL (TW) FOR UNIT DC VOLTS P/N LIST
SIZE UNIT PART 60Hz 24V 120V 208-230V 400V 480V 575V LIST 24V 110V 220V LIST SH4,8-*SW 24V 228-241-R21 $33
NO. (50Hz) (21V) (110V) (220V) (380V)* (440V) (480V) SH17-*SW
00,0 LS4,7,17 910-396-166 - -25 -22 -24 -83 -26 -27 $ 23 R21 R16 R17 $ 30 LS4,7,17- 110V 228-240-R16
*SW 220V 228-240-R17
1,13/4 LS27,37 910-396-191 - -25 -22 -24 -83 -26 -27 $ 25 R21 R16 R17 $ 35
LS37-*SW 24V 228-300-R21 $38
2,21/2,3 LS47,57,77,87 910-396-181- -25 -22 -24 -83 -26 -27 $ 50 R21 R16 R17 $ 63 110V 228-300-R03 $38
31/2 LS107 910-396-191 - -25 -22 -24 -83 -26 -27 $ 65 R21 R16 R17 $ 80 220V 228-300-R17 $38
4,41/2 LS177 910-396-196 - -25 -22 -24 -83 -26 -27 $ 90 R21 R16 R17 $105
5 LS247 910-396-161 - -25 -22 -24 -83 -26 -27 $115 R21 R16 R17 $140 12 Volt & 48 Volt DC also available upon request
*Normal Export Coil, 380V 50HZ. Note: Above are 2 winding DC Coils with DC
coil late break aux. required. See page AEG 52.

STARTER ENCLOSURES
SPARE CONTACTS - 3 Pole
For LS27 SPARE C27 $ 38 NEW STYLE (93 to Present)
Finger Touch Display
Mechanical
For LS37 #910-392-257 $ 56
For LS47 #910-392-266 $ 88 -286 $ 88 Interlock Kits
For LS57 #910-392-267 $ 125 -287 $125 K-R4 for 4, 7, 17, 27, 37* $ 19
For LS77 #910-392-268 $ 225 -288 $225 K-R47 for 47, 57, 77 $ 119
For LS87 #910-392-271 $ 260 K-R107 for 107 $ 148
For LS107 #910-392-263 $ 315 K-R177 for 177 $ 192
For LS177 #910-392-264 $ 412 K-R247 for 247 $ 463
For LS 247 #910-392-265 $ 500 LK-LUV 375H $ 70
*K-R4DC for Single Winding Coils $ 19
Contact kits for “K” series, see page AEG 68.

ACCESSORY ADAPTOR PLATES DIN RAIL: Aluminum


P-DP LIST $4.00 For contactors LS4, 7 17. Adapts mounting to DP (easy to cut) 35 mm wide
(Definite Purpose Contactor) Mounting.
P-UP LIST $8.00 For starters XLS4, 7, 17, 27. Adapts to competitive starters. with mounting holes
P-ELFA-3 LIST $9.50 for 3 pole ELFA Breaker or SP27 Contactor. RL-39 39” $6.00 List
RL-5 5” $2.00 List
Discount Schedule PL

Discount Schedule RP AEG 69


DIN RAIL

Rail Mounting Din Rail Aluminum (easy to cut 35mm


wide, 1 meter long)
Substantial installation and space savings
can be obtained through Rail Mounting,
mini relays, contactors and starters. Units DIN 46277 RL-5 (5”) $2.00 List
sap lock onto rails, eliminating the need for RL-39 (39”) $6.00 List
detailed layout drilling and tapping each with mounting holes (39”)
mouting hole. RL-5H (5”) $2.00 List
RL-39H (39“) $6.00 List

Mount Contactors (Starters) LS07, LS04, LS07, LS17, LS37.


Relays SH04, SH4, SH8. Disconnects, Motor Circuit
Protectors and ELFA MINI Breaker.
Discout Schedule PL

4.5mm

RL39H
Rail #RL-5 Rail #RL-39H
Rail #RL-39 16mm
(5”)
(39”)
Dimensions (Approx.) mm (inches)
TERMINAL BLOCKS

31.4mm

RL39

Mini Contactors,
Relays, Starters
(page AEG 11-17)
Magnetic Starters
Full voltage starters Industrial Relays
(page AEG 22 & 23) Positive guided design Disconnects/CAM
(page AEG 10) Switches
Overload Relays To 600 Amp add 4th pole)
Separate mount (see section ET, D1 & VN)
Plug-on mount
(page AEG 41-43)
Motor Circuit Protector
Manual Starters to 25HP
(page AEG 77-81)

Mini Breakers
Series ELFA ALL RAIL MOUNT
(page AEG 72-76)

AEG 70

You might also like