Wireless Repeater Manual
Wireless Repeater Manual
Manual
(G+D+W)
Interface of repeater
3. AC220V:Power port;
Definition:
1. Power module 2. Six-duplexer(BS side) 3.GSM integrated module 4.Backup
5. Power switch 6.WCDMA integrated module(BS side) 7. WCDMA integrated module(MS side)
3 Software introduction:
1. Overview:
This is a simplified version for the local connection, to monitor the repeater and do initialization, query, set,
etc
2. Connection:
Use the RS232 serial line (KJ nine-pin connector cable). Attention! If PC machine is not configured with
nine-pin male serial port, it will need a USB converter cable. Connect to the corresponding serial port of the PC,
and then turn on the software debug folder "Monitor80.exe" file,double click , popup
window as follows:
Then click the “Read Parameters List” to query all monitoring parameters。
3. Operation:
After reading the monitoring parameters, operating area interface will display the appropriate
monitoring parameters, as shown:
For example, in order to set parameters, firstly click ,Select the corresponding
operating parameters(If you want to operate all the parameters on the current page, click on ,
then click again to cancel the all the current selection.); To query the selected items, then click ;
To set the parameter, fill out value to the corresponding parameter (referring to the displayed value on the PC,
which can be changed) and click ,Then click ,parameter setting is successful,
real-time query again (refer to monitoring board, this column only for real-time parameter reading)and remote
value will be updated. (Note: When doing real-time parameter setting operation, the local parameters value can’t
be null, otherwise it will not set up successfully.) Above 2,3 parameters for GSM; 4,5 for WCDMA parameters
The other parameters panels are roughly the same, please pay attention to the following:
Alarm Enable & Status:
This interface is used to observe the current status of the device and alarm setting. As shown below, under its
box, which allows alarm generate or been prohibited. Remote monitoring value read from the alarm panel;
Equipment Info:
This window is used to query the basic information of repeater.
Network Parameter:
From this window, except for the site and device number that can’t be set, the other can be.
The query/set numbers is mainly for remote connections.
Real Time Volume Collection:
value of some quantity are out of stipulated range in the agreement (for example, no output, etc.), there will be a
4. Factory Default:
Item Default
Factory ID 17
Equipment Number FF
ATT Maximum
Inquiry Number 0
RF Switch Open
threshold(DL)
threshold(DL)
threshold(DL)
WALL
WALL
接地端子
Introduction:
1. After opening the package, fix the device to the vertical wall with two M10X90 expansion
bolts.
2. Fix the bottom bracket hole with two bolts M10X90, make repeater stable and reliable on the
vertical wall.
6. Remark:
1. MODEM is directly coupled to the BS side (Coupling factor 25dBc)with no antenna.
2. Cable of backup battery is not connected when leave factory, which need to be done after site
installation. Details please check the diagram