Elvaloy 4170 TDS - Dow
Elvaloy 4170 TDS - Dow
Elvaloy 4170 TDS - Dow
ELVALOY™ 4170
Copolymer
Description
Product Description ELVALOY™ 4170 can be used as polymer modifier
Restrictions
Material Status Commercial: Active
Typical Characteristics
Uses Polymer Modifier
Composition Ethylene Terpolymer
*Melt Flow Rate ( 190°C/2.16kg ) 8 g/10 min ASTM D1238 ISO 1133
Processing Information
*Maximum Processing Temperature 310 °C ( 590 °F )
Cast Film / Sheet Processing Nominal Values
Processing Information Temperature guidelines below are for minor amounts of ELVALOY™ 4170 extruded
in combination with solid stated PET.
Regulatory Information PET or PBT containing minor amounts of ELVALOY™ 4170 should be tested to
confim they comply with applicable food contact regulations.
The information and certifications provided herein are based on data we believe to
be reliable, to the best of our knowledge. The information and certifications apply
only to the specific material designated herein as sold by Dow and do not apply to
use in any process or in combination with any other material. They are provided at
the request of and without charge to our customers. Accordingly, Dow cannot
guarantee or warrant such certifications or information and assumes no liability for
their use.
Safety & Handling For information on appropriate Handling & Storage of this polymeric resin, please
refer to the material Safety Data Sheet.
A Product Safety Bulletin, material Safety Data Sheet, and/or more detailed
information on extrusion processing and/or compounding of this polymeric resin
for specific applications are available from your Dow representative.
Product Stewardship
The Dow Chemical Company and its subsidiaries (“Dow”) has a fundamental concern for all who make, distribute,and use its products, and for the
environment in which we live. This concern is the basis for our Product Stewardship philosophy by which we assess the safety, health, and
environmental information on our products and then take appropriate steps to protect employee and public health and our environment. The success of
our Product Stewardship program rests with each and every individual involved with Dow products ─ from the initial concept and research, to
manufacture, use, sale, disposal, and recycle of each product.
Customer Notice
Dow strongly encourages its customers to review both their manufacturing processes and their applications of Dow products from the standpoint of
human health and environmental quality to ensure that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
available to answer your questions and to provide reasonable technical support. Dow product literature, including safety data sheets, should be
consulted prior to use of Dow products. Current safety data sheets are available from Dow.
NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample any product or service (“Product”) into any
commercial or developmental application that is intended for:
a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which exceeds 72 continuous hours (or for
PELLETHANE™ Polyurethane Elastomers only, which exceeds 30 days);
b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices” include, but are not limited to, pacemaker
leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and ventricular bypass-assisted devices);
c. use as a critical component in medical devices that support or sustain human life; or
d. use specifically by pregnant women or in applications designed specifically to promote or interfere with human reproduction.
Dow requests that customers considering use of Dow products in medical applications notify Dow so that appropriate assessments may be conducted.
Dow does not endorse or claim suitability of its products for specific medical applications. It is the responsibility of the medical device or pharmaceutical
manufacturer to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW MAKES NO WARRANTIES, EXPRESS
OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW PRODUCT FOR USE IN MEDICAL APPLICATIONS.
Disclaimer
NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ
from one location to another and may change with time, the Customer is responsible for determining whether products and the information in this
document are appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices are in compliance with
applicable laws and other governmental enactments. Dow assumes no obligation or liability for the information in this document. NO WARRANTIES ARE
GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully determined; (2) analysis of hazards
and caution in handling and use are required; (3) there is greater potential for Dow to change specifications and/or discontinue production; and (4)
although Dow may from time to time provide samples of such products, Dow is not obligated to supply or otherwise commercialize such products for any
use or application whatsoever.
Additional Information