0% found this document useful (0 votes)
313 views1 page

Annexure 1-Monopole Design Parameters

This document provides design parameters for a monopole transmission line project including: 1) Line details such as circuit type and voltage, conductor and earthwire arrangement. 2) Number of phases, angle towers, suspension towers and their properties. 3) Ruling and normal spans, conductor and earthwire properties. 4) Insulator length, weight and drawing details. 5) Wind speed, site location, safety factors for design and loading. 6) Environmental conditions including temperatures. 7) Tower heights for existing and new lines. 8) Foundation type, soil properties, bearing capacity, terrain category and reliability level. 9) Pole material grade and deflection limits. 10) Concrete

Uploaded by

Md Mohsin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
313 views1 page

Annexure 1-Monopole Design Parameters

This document provides design parameters for a monopole transmission line project including: 1) Line details such as circuit type and voltage, conductor and earthwire arrangement. 2) Number of phases, angle towers, suspension towers and their properties. 3) Ruling and normal spans, conductor and earthwire properties. 4) Insulator length, weight and drawing details. 5) Wind speed, site location, safety factors for design and loading. 6) Environmental conditions including temperatures. 7) Tower heights for existing and new lines. 8) Foundation type, soil properties, bearing capacity, terrain category and reliability level. 9) Pole material grade and deflection limits. 10) Concrete

Uploaded by

Md Mohsin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Annexure 1: Design parameters Sheet

Monopole Design data Sheet:


NOTE: Without the details below design can,t be initiated.
1 JOB REFERENCE NO.

2 NAME OF CLIENT

3 NAME OF PROJECT

1 Line details - Circuit ( SC/DC/MC) & KV. & arrangement of In case of special towers, please
conductors and earthwire. provide the drawings
2 Number of phases.

3 No. of Angle Towers


4 No. of Suspension Towers
5 Tower details Angle of Wind span Weight Weight Extn No. of towers
Deviation Span (NC) Span
(BWC)

NC BWC Max Min Max Min


a Supension towers
b 15 degree angle towers
c 30 degree angle towers
d 60 degree angle towers
e 90 degree angle towers
f Rulling Span / Normal span
6 Conductors with properties
7 Earthwire with properties
8 Insulators. Suspension length & weight ,Detail
drawings with arcing
horn distance.
Tension length & weight ,Detail
drawings with arcing
9 Wind Speed / Site Location horn distance.
10 Factor of safety. A) Tower Design
Factor of safety. A)Loading
Factor of safety. A) Foundation Design
11 Environmental condition of area (Temp).
Everyday Temperature
Minimum Temperature
Max Conductor Temperature
Max Groundwire Temperature
12 Tower Height.
a Connecting existing line, if any Please specify the
restrictions if any related
b New / Proposed line to dia of pole
13 Height of lower conductor
14 Height of middle conductor
15 Height of top conductor
16 GA Drawing / Plan, if any.
17 Design Code ASCE Manual No -72, IS 802 (part I & part II)-1997, IS 5613 (part I &
part II), transmission line manual (publication no -268 )
18 Type of foundation

19 Type of Soil (Normal / Black cotton) Please provide soil investigations report
20 Soil Bearing Capacity (T/Sqm) strictly if design to be initiated.
21 Terrain category
22 Reliability level
23 pole shaft material grade
24 Pole deflection limits (%) if any special provision ,please
specify.
25 Grade of foundation concrete
26 Grade of base plate & bolts
27 Nominal Span
28 Please provide special provisions for designining if any
point left above , and given in specification .