Center Line Layout
Center Line Layout
FOOTING = 50mm
COLUMNS = 40mm
F1 F1 F1 F1 FLOOR/ROOF BEAMS = 25mm
C F2 F2
75
SLABS = 20mm
3 -12# ON EACH FACE
[ TOTAL : 8 NOS 12# ]
8. FINISHED GROUND LEVEL HAS BEEN
D C2 C1 C1 C1 C1 C2
CONSIDERED ± 0 MM/ FEET.
9. IT IS DESIGNED FOR G + 1 STRUCTURE.
2875
C1 C1
11. Plot Size 17800 x 12500
G C2 C1 C1 C2
1562
250
COLUMN TYPE - C2
DEFORMED BARS
NGL CONCRETE
LAYOUT PLAN OF FOOTING & COLUMN GRADE TENSION COMPRESSION
M-25 50 D 38 D
P
1 X 1
Education Purpose Only
100 100
1500 signature signature
d2
PROJECT CONSULTANT :-
d1
ARCHITECT :-
PCC 1:3:6 100 signature of (ARCHITECT)
SAND FILLING 100
Y Education Purpose Only
SECTION 1-1 RA & RB ISOLATED FOOTING SCHEDULE signature of (STRUCTURAL ENGINEER) .
TRAPEZOIDAL FOOTING PLAN
FOOTING FOOTING SIZE REINFORCEMENT
MARK A B d1 d2 RA RB Project Title:-
PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE - II & PHASE -III
F1 1800 1800 250 150 12 @150 c/c 12 @150 c/c Drawing Title:-
LAYOUT PLAN OF COLUMNS
& FOOTINGS FOR 2BHK QUARTER
SCALE
F2 1500 1500 200 100 12 @170 c/c 12 @170 c/c DATE DRN BY STR. DESIGN. DRG. NO.
SS/2BHK/ST/01
REV.
0