ATER LEVELER

DATA POOL SPA CATCH BASIN

OVERFLOW
PERIMETER: 236'-0" 33'-0" 221'-0"
SURFACE AREA: 1,100 SQ.FT 63 SQ.FT 216 SQ.FT
WATER DEPTH: 3'-0" - 6'-0" 3'-6" 3'-0"
VOLUME: 28,500 GAL 1,600 GAL 4,850 GAL
TURNOVER: 360 MIN 30 MIN N/A
CIRCULATION RATE: 79 GPM 53 GPM N/A A&A MANUFACTURING
OVERFLOW DESIGN: 1.58 GPM/FT 1.58 GPM/FT N/A (#5714XX) 32” 12" TILED VANISHING
FLOW RATE: 132 GPM 42 GPM N/A PEBBLE TOP DEBRIS EDGE WALL. SLOPE BACK
REMOVAL CHANNEL TOWARDS POOL AT 1:12
CATCH BASIN
PROJECT DATA DRAIN (TYP. OF 2)
2

SITE RETAINING WALL


3'-0" W.D.
BY OTHERS UNDER
SEPARATE PERMIT

3'-0" W.D. 6'-0" W.D.

AQUASTAR (#JE31xx)
FLUSH-MOUNT EYEBALL PUL PRODUCTS (#)
SPA RETURN FITTING 20” OPENFLOW
(TYP. OF 4) PEBBLE TOP
SUCTION COVER
NOTE: IN-FLOOR CLEANING (TYP. OF 2)
12" TILED VANISHING EDGE HEADS NOT SHOWN. DESIGN
WALL. SLOPE BACK BY OTHERS.
TOWARDS SPA AT 1:12
3'-0" W.D.

WATERWAY (#210-3330)
VENTURI TEE #7 SPA JET 1'-9"
FITTING (TYP. OF 8) (6) POOL STEPS AQUASTAR (#JE31xx) FLUSH-MOUNT PENTAIR (#620425)
W.D.
EYEBALL VANISHING EDGE RETURN MICROBRITE RGBW
1 FITTING (TYP. OF 16). PROVIDE COLOR CHANGING LED
SP5 WATTS (#LFN36M1 3/4) BACKFLOW LIGHT (TYP. OF 11)
3'-6" W.D. PREVENTER ON VANISHING EDGE
RETURN LINE (TYP. OF 1)

8650-89

PENTAIR (#5211XX)
SPACOMMAND
TEN-FUNCTION SPA-SIDE
AQUASTAR (#JE31xx)
REMOTE W/ PENTAIR 9" W.D. FLUSH-MOUNT EYEBALL
(#521180) RECESSED
POOL RETURN FITTING
MUDBOX
1 TILED (TYP. OF 8)
SP5.1 BAJA
2
SHELF
SP5

8650-89

2
SP5.1
PUL PRODUCTS (#) 12" POOL COPING
VENTURI SKIMMER ON 12" BOND BEAM
(TYP. OF 2)

PENTAIR (#580037) COLORVISION


BUBBLER W/ PENTAIR (#618040)
MICROBRITE TO GLOBRITE NICHE
ADAPTER & PENTAIR (#620425)
MICROBRITE COLOR LED LIGHT W/
100' CORD (TYP. OF 5)
1'-6" W.D.

SP1 Layout sheet includes


section markers, descriptions 3

of fittings used in the SP5.1

pool/spa, callouts for RUNNEL WATER FEATURE AREA


important project elements, WITH STEPPER FOR EGRESS

water depths, and project data

Project No. 2023.183

Sheet Name

Pool & Spa


Layout Plan

Sheet No.

1
POOL & SPA LAYOUT PLAN
1/4"=1'-0"
SP1
Date Issued

03.11.2023
© 2023
ATER LEVELER

OVERFLOW
1'-2"
14'-6" 2' 1' 44'-10" 1' 2'

1'-2"

2'

1'

11'

14'
1'-2"
1'-3" 17'
2' 1'-2" 2' 1' 10'-6" 1' 2' 1' 13'-6 2"1
20'-1" 6'-11 2"
1
3' 1' 2'

1' 1'
12'-61 2"
1'-6"
11'-61 2"

6' 3'
1'
1'
1'-6" 1'
1' 8650-89

7'-8"

27'-91 4" 26'-4"

8650-89
1'

20'-4" 20'-103 8"


19'-4"

4'-8" 8'-10" 1' 2' 1' 6'-8" 4' 22'-115 8" 5'-111 2"

48'-61 8"

SP2 Dimension sheet


includes dimensions for wall
thicknesses, stair sizes,
widths of each body of water,
and the triangulation
distances from the house

10'-10" 11'-81 2"

4'-5"
1'

12'-93 8" 12'


11'

Project No. 2023.183

Sheet Name
4'-5"
Pool & Spa
Dimension
Plan
Sheet No.

1
DIMENSION PLAN
1/4"=1'-0"
SP2
Date Issued

03.11.2023
© 2023
(SP3 Piping Plan not yet
available for this sample
project) 8'-51 2"

3'-2"
4'-5 2"
1
1'-4" 6" 1'-6" 8"

SP4 Equipment Plan provides


on-center dimensions to
suction and return piping,
equipment callouts for 3" 21 2" 21 2" 2"

pumps/filters/heaters/etc. and
callouts for other smaller PENTAIR (#263056) FULLFLOXF PENTAIR (#R171096)
THREE WAY VALVE W/ PENTAIR SERIES 320 INLINE
equipment like valves and (#521485) INTELLIVALVE
ACTUATOR (TYP. OF 2)
EROSION CHLORINATOR
8'-51 2"
junction boxes

PENTAIR (#011075)
INTELLIFLO3 VSF 3.0HP
VARIABLE SPEED PUMP
PENTAIR
(#263056) 5'-31 2"
FULLFLOXF
THREE WAY
VALVE

PENTAIR (#619963) 300W


PENTAIR (#521907)
LOW VOLTAGE
INTELLICENTER i5PS
TRANSFORMER (TYP. OF 2)
SHARED EQUIPMENT POOL
W/ INTERMATIC
AUTOMATION SYSTEM
(#PJB4175) 4 LIGHT
JUNCTION BOX (TYP. OF 2)
PENTAIR (#CCP520)
CLEAN & CLEAR PLUS 520
SQ.FT CARTRIDGE FILTER

NOTES:
Project No. 2023.183

1. AUTOFILL DOMESTIC WATER SUPPLY BY PLUMBING CONTRACTOR. INSTALL LEVOLOR K2000 SENSING LINE IN SURGE TANK. CONNECT 1" WATER SUPPLY TO EDGE RETURN.
2. INSTALL 1" DRAINAGE LINE BEFORE CARTRIDGE FILTER TO DRAIN EXCESS WATER AS NEEDED. RUN TO LOW SPOT OR RUN TO CLEAN OUTS. COORDINATE DRAINAGE OUTLET LOCATION WITH POOL BUILDER.
3. IN-FLOOR CLEANING SYSTEM LAYOUT BY OTHERS. REFER TO MANUFACTURER DESIGN FOR INSTALLATION INSTRUCTIONS. COORDINATE LOCATION FOR 8-PORT VALVE(S) WITH POOL CONTRACTOR. Sheet Name

4. FIELD ADJUSTMENTS REQUIRED FOR ZERO EDGE OVERFLOW RETURNS. CALIBRATE FLOW RATES TO MINIMIZE WATER SURFACE DISTURBANCE. Fountain
5. HEATER GAS SUPPLY LINE(S) BY PLUMBING CONTRACTOR. PROVIDE GAS SUPPLY CONNECTIONS FOR EACH HEATER SHOWN. REFER TO MFG MANUAL FOR GAS LINE SIZING AND CONNECTION REQUIREMENTS. Equipment
6. ELECTRIC PANEL SIZING BY ELECTRICAL CONTRACTOR. Plan
7. ELECTRICAL DISCONNECT SWITCHES, BONDING, GROUNDING, AND AUTOMATION WIRING REQUIRED FOR POOL EQUIPMENT. REFER TO MFG MANUALS. Sheet No.
8. BONDING, GROUNDING, AND WATER BONDING BY ELECTRICAL CONTRACTOR REQUIRED PER NEC ARTICLE 680 AND ANY STATE AND LOCAL CODES.

1
FOUNTAIN EQUIPMENT PLAN
1-1/2"=1'-0"
SP4.1
Date Issued

03.11.2023
© 2023
PIPE SIZE
LEGEND
1"
11 2"
2"
21 2"
3"
4"

SP4.1 3D Equipment shows a


few 3D renders of the
equipment layout design that
we just saw in SP4

Project No. 2023.183

N/A

Sheet Name

3D Fountain
Equipment

Sheet No.

1
3D EQUIPMENT
NOT TO SCALE
SP4.3
Date Issued

03.11.2023
© 2023
67'-8"

1'-4" 2'-10" 44'-10" 4' 10'-6" 2'-10" 1'-4"

8" 8" 1'-10" 1' 5'-6" 28'-8" 10'-8" 1' 2' 1' 1'-6" 7'-6" 1'-6" 1' 1'-10" 8" 8"

1'-3" 3' 1'-3" 5'-83 8" 22'-115 8" 4' 6'-8"

101 2"
20'-1" 1' 1'

POOL COPING POOL COPING


+0'-0" +0'-0"
E.Q.
9"
CATCH BASIN COPING 1'-6" 57 8" TYP. 1'-9" CATCH BASIN COPING
-1'-6" E.Q. -1'-6"
3'
3'-6"

3' 6' 3' 3' POOL SHALLOW END


-3'-51 4"

CATCH BASIN FLOOR CATCH BASIN FLOOR


-4'-111 4" -4'-111 4"
BOTTOM OF POOL SHELL
POOL DEEP END -5'-111 4"
-6'-51 4"
BOTTOM OF POOL SHELL
-7'-51 4"
RETAINING WALL FOOTING RETAINING WALL FOOTING
BY OTHERS BY OTHERS

POOL, SPA & CATCH BASIN SECTION


1 3/8"=1'-0"

22'-2"

1' 17' 2'-10" 1'-4"

1' 1'-10" 8" 8"

POOL COPING
+0'-0"

POOL WATERLINE
+0'-0"

CATCH BASIN COPING


-1'-6"
SP5 Sections shows the CATCH BASIN WATERLINE
section cuts that were -1'-103 4"

indicated on SP1 -- we will


provide excavation depths, 6' 3'

floor/wall thicknesses, water


depths, and overall CATCH BASIN FLOOR

dimensions for the -4'-111 4"

pool/spa/etc.
POOL DEEP END POOL DEEP END
-6'-51 4" -6'-51 4"

BOTTOM OF POOL SHELL BOTTOM OF POOL SHELL


-7'-11 4" -7'-11 4"

RETAINING WALL FOOTING


BY OTHERS

POOL RUNNEL SECTION


2 1/2"=1'-0" Project No. 2023.183

N/A

Sheet Name

Sections

NOTES: Sheet No.

1.
2.
3.
FINAL FLOOR & WALL THICKNESS SPECIFICATIONS BY STRUCTURAL ENGINEER.
REBAR NOT SHOWN ON PLANS. STEEL SCHEDULE BY STRUCTURAL ENGINEER.
RETAINING WALL ENGINEERING BY OTHERS.
SP5
Date Issued

03.11.2023
© 2023
13" COPING
2" MORTAR BED
1
TOP OF COPING
0'-0"
TOP OF BOND BEAM
-0'-13 4"
12" BOND BEAM
WATERLINE
POOL DECK -0'-443" WATERLINE
MUD BOX
8" CONCRETE WALL 6" OF 11 2" PVC 12"
1 WATERLINE PIPE SLEEVE
2" POOL FINISH TYP.
TILE NIPPLE
R6"
MIN.
PENTAIR
1" PVC CONDUIT EXTEND MICROBRITE
8" CONCRETE TO TRANSFORMER LED LIGHT
POOL FLOOR

1" CLEAN FILL


2" DRAIN
1

TUBE
CONDUIT CABLE TO
NOTES: AUTOMATION
NOTES: PANEL
1. MOUNT TRANSFORMER @ 18" MIN. ABOVE WATERLINE.
1. CONCRETE THICKNESS, REINFORCING SCHEDULE, AND CLEAN FILL DEPTH BY STRUCTURAL ENGINEER. 2. LIGHTS ARE FURNISHED W/ 100' CORDS.

POOL WALL BOND BEAM DETAIL 5 TYPICAL LIGHT DETAIL (OPTIONAL) SPA SIDE REMOTE - MUD BOX DETAIL
1 3/4"=1'-0" 3/4"=1'-0"
9 1"=1'-0"

OPENFLOW360 DEPRESS 1 SKIMMER SKIMMER


2"POOL FINISH
LID W/ 6" MIN.
1'
UNBLOCKABLE AROUND LID W/
CONCRETE POOL EXTENSION EXTENSION
PEBBLE TOP DRAIN
FLOOR COLLARS COLLARS
MAIN DRAIN

REFER TO SKIMMER
1 PIPING PLAN THROAT
2" POOL VENTURI
FINISH FOR PIPE RETURN
SIZE ELEVATION
INLET

OPTIONAL 2" SHOTCRETE


VACUUM
1 1 2" RETURN
PIPING SUCTION
LINE
FLUSH-MOUNT PERMACAST DRYPACK
RETURN FITTING GROUND
1" GRANULAR HYDROSTATIC TERMINAL THINSET
P/N PB2008 SECTION VIEW TILE ADHESIVE
FILL TYP. RELIEF VALVE
OR MASTIC
POOL WALL

NOTES: NOTES:
NOTES:

1. CONCRETE THICKNESS AND REINFORCING SCHEDULE BY STRUCTURAL ENGINEER. 1. INSTALL PERMACAST GROUND TERMINAL IN PLACE OF PLUG IN ONE SKIMMER PER POOL.
1. SOLVENT WELD CONNECTION TO 11 2" RETURN PIPING REQUIRED. 2. CONNECTION TO GROUND SYSTEM BY ELECTRICAL CONTRACTOR.
2. COLOR MATCH TO POOL FINISH. CONFIRM PART NUMBER ON EQUIPMENT SCHEDULE. 2. USE 4" FITTINGS AT MAIN DRAIN MANIFOLDS.
3. SEE PIPING PLAN FOR MAIN DRAIN SUCTION PIPING SIZE FROM EQUIPMENT ROOM. 3. PROVIDE 2" VACUUM SUCTION FROM SKIMMER CLOSEST TO EQUIPMENT ROOM.
3. RETURNS FOR VANISHING EDGE POOLS TO BE 9" ABOVE FINISH FLOOR.

FLUSH-MOUNT RETURN FITTING DETAIL DEBRIS REMOVAL DRAIN DETAIL VENTURI SKIMMER DETAIL
2 3" = 1'-0" 6 1" = 1'-0" 10 3/8"=1'-0"

SPA WATERLINE

3/4" VACUUM
RELIEF VALVE
6" SPA JET
WATERLINE

FROM EDGE PUMP

SEE PIPING PLAN


FOR PIPE SIZING
TO EDGE FLOOR AIR LOOP IN SPA
RETURNS BENCH. REFER TO
PIPING PLAN FOR PIPE
JET RETURN LOOP IN SIZING.
SPA BENCH. REFER TO
PIPING PLAN FOR PIPE

NOTES:
SIZING.
SP6 Details shows a list of
NOTES:
1. BALANCING REQUIRED TO EQUALIZE FLOW FOR ALL EDGE RETURNS.
1. HARTFORD LOOP AND AIR SUPPLY VENTING ABOVE WATER LEVEL REQUIRED.
standard details that are
2. VACUUM RELIEF VALVE ON RETURN SIDE REQUIRED TO PREVENT BACKFLOW FROM FLOODING THE

3.
CATCH BASIN OR SURGE TANK.
CHECK VALVE ON SUCTION SIDE REQUIRED TO MAINTAIN PUMP PRIME FROM CATCH BASIN OR SURGE TANK. 2.
REFER TO PIPING PLAN FOR LOCATION(S).
HARTFORD LOOP WILL BE OUTSIDE OF SPA SHELL FOR PERIMETER OVERFLOW SPAS. relevant to this project. Most
3
VACUUM BREAKER DETAIL
7
TYPICAL JET DETAIL of the details needed are
3/4"=1'-0" 1"=1'-0"
already designed & available
HARTFORD LOOP (BOTTOM
SENSOR HOUSING
1
2"
CONDUIT TO K2000
1" COUPLING
OF AIR LINE MUST BE
ABOVE WATERLINE)
to insert into our projects -- we
CONTROL SYSTEM AT
EQUIPMENT ROOM SPA WATERLINE
just need to determine which
SENSOR PROBES
1. SENSOR COMMON PROBE
HIGH WATER LEVEL
details should be included
2. HIGH WATER SENSOR PROBE
3. FILL SENSOR PROBE
EYEBALL
FITTING
based on the features of the
(OPTIONAL) SPA JET
1" EQUALIZER LINE
MINIMUM OPERATING
project
WATER LEVEL (12" TYP.)

SURGE TANK FLOOR


AIR LOOP IN SPA
BENCH. REFER TO
PIPING PLAN FOR PIPE
JET RETURN LOOP IN SIZING.
MANUFACTURER NOTES: SPA BENCH. REFER TO
PIPING PLAN FOR PIPE
1. INSTALL SENSOR SUCH THAT LONG PROBE TIPS ARE CLOSE TO MINIMUM OPERATING LEVEL AND SIZING.
SHORT TIP IS CLOSE TO HIGH WATER LEVEL.
2. WHEN MOUNTING A SLIP SENSOR ON A STATIC PIPE, GLUE 1" FITTINGS WITH 793 IPS BRAND NOTES:
ABS/PVC GLUE. DO NOT GLUE 2" FITTINGS.
3. INSTALL SENSOR IN SURGE TANK OR SURGE BASIN. CONNECT FILL LINE TO VANISHING EDGE RETURN. 1. HARTFORD LOOP WILL BE OUTSIDE OF SPA SHELL FOR PERIMETER OVERFLOW SPAS.

SURGE TANK AUTOFILL DETAIL TYPICAL JET DETAIL


4 3/4"=1'-0"
8 1"=1'-0"

Project No. 2023.183

N/A

Sheet Name

Details

Sheet No.

SP6
Date Issued

03.11.2023
© 2023