Manual AM706C V170701 (Exp)
Manual AM706C V170701 (Exp)
Document: NLT-AM706C-SSEN
Edition: V170701(EXP)
Software: V1.3
Contents
System description .............................................................4
Main unit .......................................................................4
Sensor unit ....................................................................4
Alarm unit ......................................................................5
Peripheral equipment .......................................................5
Printer ................................................................... 6
Repeater................................................................. 6
System specification ...........................................................7
Physical ........................................................................7
Power ...........................................................................8
Measurment ...................................................................8
Functions ......................................................................8
Interface ........................................................................8
Operation..........................................................................9
Sleep mode ....................................................................9
Backlight .......................................................................9
Unit of the wind speed ......................................................9
Power drops alarm...........................................................9
Wind speed alarm level ...................................................10
Set the wind alarm “dividing value” ...................................10
Set the first level alarm value ...........................................10
Set the second level alarm value.......................................11
Alarm..........................................................................12
Mute the alarm ..............................................................12
Turn off the alarm ..........................................................12
Gust mode ...................................................................12
Printed time interval .......................................................13
Printer setting...............................................................14
Printed Format..............................................................15
The display of the second line LEDs ..................................16
Calibration ......................................................................17
Installation ......................................................................18
Main unit .....................................................................18
Table mounting .......................................................18
Flush mounting.......................................................19
Sensor unit ..................................................................20
Alarm unit (AM706A1).....................................................22
Installation diagram Wiring diagram........22
Alarm unit (AM706A2).....................................................23
Installation diagram..................................................23
Wiring diagram .......................................................23
System diagrams ..............................................................24
Wiring diagram.................................................................25
Supplementary wiring for printer DPU-414 ..........................26
Supplementary wiring for repeater IR761 ............................26
System description
The AM706 is consisted of 3 parts: Main unit, Sensor unit, Alarm units.
Main unit
The main unit AM706C receives the signal from
the sensor unit, and displays:
¾ Relative wind direction
¾ Relative wind speed
¾ Maximum wind speed
¾ First and second level alarm settings
The main unit also output the setting of the wind speed AM706C
alarm to the alarm unit.
Sensor unit
The Sensor unit AM706S includes three parts:
¾ Wind speed sensor: a rotor with three wind cups.
¾ Wind direction sensor:
a wind vane to drive an absolute angle sensor unit.
¾ Junction box
AM706S
It has a waterproof junction box and a sensor unit transmitter.
4
System description
Alarm unit
AM706A1 is installed in the CCR (cargo control room).
Peripheral equipment
Printer: DPU414, print date, wind speed & direction and so on
VDR: (vessel data recorder): record data from the main unit
5
System description
Printer
Operating temperature: 0 ~ 40℃
Humidity: 30 ~ 80% RH
Weight: 580 g
Repeater
Operating temperature: 0 ~ 40℃
Humidity: 10 ~ 90% RH
Weight: 1.4kg
Protection: IP 23
Power: DC24V
Consumption: 2W (24V)
IR761
Compass safe distance: 85 cm
6
System specification
Physical
Operating temperature:
Main unit -15°C~+55°C
Sensor unit -15°C~+70°C
Alarm unit -15°C~+55°C
Storage temperature:
Main unit -20°C~+70°C
Sensor unit -20°C~+85°C
Alarm unit -20°C~+70°C
Humidity:
Main unit 10%-90% relative humidity
Sensor unit 10%-100% relative humidity
Alarm unit 10%-100% relative humidity
IP degree
Main unit IP 22
Sensor unit: IP 56
Alarm unit: AM706A1: IP 54
AM706A2: IP 56
Weight:
Main unit 2kg
Sensor unit 10 kg
Alarm unit: AM706A1: 0.3kg
AM706A2: 3kg
7
System specification
Power
Main power supply: DC24V (20-32V)
Power consumption: less than 10W (DC24V)
AC adaptor: AC110/220V to DC24V
Measurment
The range of the wind speed: 1.2~25m/s
The range of the wind direction: 0~359°
The accuracy of the relative wind speed: ± 5% (min: 0.1m/s)
The accuracy of the relative wind direction: display accuracy 10 °,
output accuracy ± 1 °
Min start wind speed: ≤1.2m/s
Functions
Alarm: power drops alarm, wind speed alarm
Calibration: wind direction can be calibrated
Interface
Wind sensor input: NMEA0183-MWV
Output to alarm unit: Switching value
Output to repeater IR761: NMEA0183-MWV
Output to printer DPU414: RS232C
GPS input: NMEA0183-RMC
Direction and speed output: 4800bps
8
Operation
Sleep mode
Press [▲] and [▼] at the same time, turn the main unit into sleep mode.
Backlight
Press [▲] or [▼] to set backlight of the main unit.
9
Operation
10
Operation
Setting range:
OFF Turn the first level alarm off
3~ “X” m/s Step width: 1m/s
10~ “X” km/h Step width: 2km/h
5~ “X” knots Step width: 1kn
Setting range:
OFF Turn the second level alarm off
“X+1” ~ 60 m/s Step width: 1m/s
“X+1” ~ 216 km/h Step width: 2km/h
“X+1” ~ 116 knots Step width: 1knots
11
Operation
Alarm
When wind speed achieves or exceeds the alarm setting value for 30
seconds, the main unit AM706C will sound an alarm and the letters in first
LED line will be flashing; meanwhile, the main unit will send the alarm
signal (switching value) to the alarm unit. AM706A1 (the alarm installed in
the cargo control room) and AM706A2 (the alarm installed on the cargo
deck) are sounding and flashing.
Gust mode
Press [F] four times on the main unit to inter the “gust mode”. “Max” is
shining. The second line LEDs show the time interval, press [▲] or [▼] to
select the interval time value. You can choose from 1 /2 /5 /10 min.
12
Operation
13
Operation
Printer setting
DPU-414 Print settings is showing as follow:
Dip SW-1
1 (OFF):Input=Serial
2 (ON ):Printing Speed=High
3 (ON ):Auto Loading=ON
4 (OFF ):Auto LF=OFF
5 (ON ):Setting Command=Enable
6 (OFF):Printing
7 (ON ):Density
8 (ON ):=100%
Dip SW-2
1 (OFF):Printing Columns=80
2 (ON ):User Font Back-up=ON
3 (ON ):Character Select=Normal
4 (ON ):Zero=Normal
5 (ON ):International
6 (ON ):Character
7 (ON ):Set
8 (OFF):=U.S.A.
Dip SW-3
1 (ON ):Data Length=8 bits
2 (ON ):Parity Setting=No
3 (ON ):Parity Condition=Odd
4 (ON ):Busy Control=H/W Busy
5 (ON):Baud
6 (OFF ):Rate
7 (OFF ):Select
8 (OFF):=4800 bps.
14
Operation
Printed Format
① ② ③ ④ ⑤ ⑥
(1) Date/month/year
(2) Hour: minute
(3) North Latitude (South Latitude)
(4) East Longitude (West Longitude)
(5) Wind direction
(6) Wind speed
(1) Date/month/year
(2) Hour: minute
(3) North Latitude (South Latitude)
(4) East Longitude (West Longitude)
(5) Wind direction
(6) Wind speed
15
Operation
After setting, press [F] again, the display of the LEDs on the main unit
come back to normal situation.
16
Calibration
17
Installation
Main unit
The main unit can be table or flush mounted.
Table mounting
Unit: mm
18
Installation
Flush mounting
19
Installation
Sensor unit
Put the wind vane at the top of the bracket, install as the following order:
black O-ring, flat washer, spring washer, two nuts, cotter pin. The two nuts
must be screwed tightly and cotter pin locked.
Put the wind cups at the bottom of the bracket, then install as the following
order: flat washer, spring washer, two nuts, cotter pin. The two nuts must
be screwed tightly and cotter pin locked.
20
Installation
Ensure that the Sensor unit is mounted high enough to avoid any
interference from obstacle.
The fixed pillar/pipe diameter should be 60mm and make sure the activity
radius 550mm.
After the installation, calibration must be taken. Please refer to the “page
P14” for detail.
21
Installation
ATTENTION!
The three lines of LIGHT, COMMON, SOUND will be damaged if
connected to the AC220V power supply!
High Voltage Hazard!
High voltage is on LIGHT, COMMON, SOUND lines when alarm is
connected with power.
22
Alarm unit (AM706A2)
AM706A2 can be installed on a console, panel, on the overhead, or on the
bulkhead with tapping screws.
Installation diagram
Unit:mm
Wiring diagram
23
System diagrams
24
Wiring diagram
25
Supplementary wiring for printer DPU-414
26