1. INTRODUCTION
CONTENTS The Esprit eco is a combination boiler providing both central
heating and instantaneous domestic hot water. Featuring full
1. Introduction ............................................................... 2 sequence automatic ignition and fan assisted combustion.
Safety.......................................................................... 2 Due to the high efficiency of the boiler, condensate is produced from
Electricity Supply......................................................... 2 the flue gases and this is drained to a suitable disposal point through
Important Notes........................................................... 2 a plastic waste pipe at the base of the boiler. A condensate ‘plume’
will also be visible at the flue terminal.
2. Boiler Operation........................................................ 3
Controls Diagram........................................................ 3
SAFETY
To Start the Boiler........................................................ 3
Current Gas Safety (Installation & Use) Regulations or
Operation Modes......................................................... 3 rules in force.
Preheat Domestic Hot Water....................................... 3 In your own interest, and that of safety, it is the law that this
Control of Water Temperature..................................... 3 boiler must be installed by a Gas Safe Registered Engineer, in
Efficient Heating System Operation............................ 4 accordance with the above regulations.
Weather Compensation............................................... 4 In IE, the installation must be carried out by a Registered Gas Installer
Boiler Frost Protection................................................. 4 (RGII) and installed in accordance with the current edition of I.S. 813
“Domestic Gas Installations”, the current Building Regulations and
Boiler Reset................................................................. 4
reference should be made to the current ETCI rules for electrical
Mains Power Off.......................................................... 4 installation.
3. System Water Pressure............................................ 4
It is essential that the instructions in this booklet are strictly
4. Condensate Drain...................................................... 4 followed, for safe and economical operation of the boiler.
5. General Information.................................................. 5
ELECTRICITY SUPPLY
Boiler Pump................................................................. 5
This appliance must be earthed.
Minimum Clearances................................................... 5 Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Escape of Gas............................................................. 5
Cleaning...................................................................... 5 IMPORTANT NOTES
Maintenance................................................................ 5 • This appliance must not be operated without the casing
6. Mechanical 24 Hour Timer........................................ 5 correctly fitted and forming an adequate seal.
7. Points for the Boiler User......................................... 6
• If the boiler is installed in a compartment then the compartment
Troubleshooting........................................................... 6 MUST NOT be used for storage purposes.
8. Normal Operation Display Codes............................ 7
• If it is known or suspected that a fault exists on the boiler then
9. Fault Codes................................................................ 8 it MUST NOT BE USED until the fault has been corrected by
a Gas Safe Registered Engineer or in IE a Registered Gas
Installer (RGII).
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the
Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500.
Ideal is a member of the Benchmark scheme and fully supports the aims of the programme.
Benchmark has been introduced to improve the standards of installation and commissioning of
central heating systems in the UK and to encourage the regular servicing of all central heating
systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
Legend
off status burner
A. Mode Knob
e
max
D. Boiler Status
E. Burner ‘on’ Indicator A B C K D E
F. Domestic Hot Water Preheat on / off indicator 21
20 19 18 17
F
16
G. Timer
22
I 0
15
23
14 13 12 1
24
H. Pressure Gauge Esprit eco
1
2
3
1
J. Condensate Drain
10
4
5 9
6 7 8
22
4
21
5
This must be obtained with an easily removable panel, to enable
the system pressure gauge to be visible and to provide the 100mm
20
6
clearance required for servicing.
19
7
18
8
ESCAPE OF GAS
17
9
Should a gas leak or fault be suspected contact the National Gas
10
16
Emergency Service without delay. Telephone 0800 111 999. 11
15
12 14
Ensure that;
13
CLEANING SETTING UP
For normal cleaning simply dust with a dry cloth. To remove stubborn The outer dial should be set to the current time. Rotate the dial
marks and stains, wipe with a damp cloth and finish off with a dry slowly in a clockwise direction, until the correct hour is aligned with
cloth. DO NOT use abrasive cleaning materials. the arrow printed on the dial.
Note that the outer dial is printed with the 24hr clock e.g. 8.00am
MAINTENANCE = 8 on the dial, 8.00pm = 20 on the dial.
The appliance should be serviced at least once a year by a Gas
Do not attempt to rotate the dial in an anti-clockwise direction.
Safe Registered Engineer or in IE a Registered Gas Installer
(RGII).
PROGRAMMING SWITCHING TIMES
Set tappets to outer edge for ON periods and set tappets to inner
edge for OFF periods.
The example shown has been set with 2 on periods.
ON at 9.00am. OFF at 1.00pm. (13 hours)
ON at 6.00pm. (18 hours) OFF at 10.00pm (22 hours)
Note. If boiler does not light when in “timed on” or “manual on”
position, increase temperature on room stat.
Note. In line with our current warranty policy we would ask that you check through the following guide to identify any
problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other
than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is
not gained by the engineer.
TROUBLESHOOTING
Check the mains power is turned Check the mains power is turned
on and ensure mode knob (A) is on and ensure mode knob (A) is Check the mains power is turned
in the summer or winter position in the winter position on and ensure mode knob (A) is
in the winter position
The boiler is in standby mode awaiting either a central heating call or hot water demand.
The boiler has a call for central heating but the appliance has reached the desired
temperature set on the boiler.
The boiler has a call for hot water but the appliance has reached the desired temperature set on
the boiler.
continued . . . . . .
continued . . . . . .
BCC Activation Fault Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).
BCC Fault
Low Water Pressure Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G).
To re-pressurise the system see Section 3. If the boiler still fails to operate then please
contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if
outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
Flame Loss 1. Check other gas appliances in the house are working to confirm a supply is present in
the property.
2. If other appliances do not work or there are no other appliances, check the gas supply is on
at the meter and/or pre payment meter has credit. If the boiler fails to operate then please
contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if
outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
Fan Fault Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).
Flow Thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).
Return Thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).
Outside Sensor Failure Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).
Unconfigured PCB Unconfigured PCB. Please contact Ideal Boilers (if under warranty) or alternatively a Gas
Safe Registered Engineer if outside of the warranty period. In IE contact a Registered
Gas Installer (RGII).
Flow Temperature Overheat Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G).
or No Water Flow To re-pressurise the system see Section 3. If the boiler fails to operate then please contact
Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside
of the warranty period. In IE contact a Registered Gas Installer (RGII).
Flame Loss 1. Check other gas appliances in the house are working to confirm a supply is present in
the property.
2. If other appliances do not work or there are no other appliances, check the gas supply is on
at the meter and/or pre payment meter has credit. If the boiler fails to operate then please
contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if
outside of the warranty period. In IE contact a Registered Gas Installer (RGII).
5 Boiler Resets in 15 minutes 1. Turn electrical supply to boiler off and on.
2. If the boiler fails to operate please contact Ideal Boilers (if under warranty) or
alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE
contact a Registered Gas Installer (RGII).
False Flame Lockout Reset the appliance - if the boiler fails to operate then please contact Ideal Boilers (if
under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In IE contact a Registered Gas Installer (RGII).