Quick Reference Guide For Installation of Dexis Imaging Suite Software On A Workstation

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Quick Reference Guide for Installation of

DEXIS® Imaging Suite Software on a Workstation

Verify System Specifications


All DEXIS network installations must begin with server installation (see Quick Reference Guide for Installation of
DEXIS Imaging Suite Software on a Server). Before installing DEXIS Imaging Suite, it is necessary to verify that the
workstation meets or exceeds minimum system requirements for the current version of DEXIS. Up-to-date DEXIS System
Requirements are available at www.dexis.com under Get Support a SYSTEM REQUIRMENTS.

Please be aware the specifications listed in this document are the bare minimum requirements for DEXIS to function.
Whenever possible, we recommend utilizing specifications above the minimum as faster processors and hard drives
and more memory will enhance performance.

Especially important specifications to check are:


• Operating System • DVD Drive • USB ports
• Central Processing Unit (CPU) • Network Card • Graphics card
• System Memory (RAM) • Motherboard • Hard Disk Drive

This information can be found in the device’s manual or from the manufacturer’s website. If neither of these is
available, each component can be looked up in System Information. Descriptions of what can be found in and how to
access System Information are available through the Microsoft knowledgebase.

If any specifications of the server do not meet or exceed the minimum requirements, it will be necessary to upgrade
computers prior to installing the DEXIS software. If requirements are met, then peripheral device compatibility can then
be checked.

Verify Peripheral Device Compatibility


In addition to verifying that the server itself meets system requirements, it will be necessary to verify that all peripheral
hardware to be used in DEXIS is supported.

All DEXIS sensors and cameras are fully supported in the current versions of DEXIS Imaging Suite. However, the Classic
sensor with PC card interface is not supported in 64-bit Windows environments.

For third party sensors, cameras, or a panoramic unit that will be utilized through DEXIS, verify that each device will
work in DEXIS. Current supported devices are found at www.dexis.com under Get Support a SUPPORTED HARDWARE,
or in the HARDWARE INSTALLATION section of the Software Manual. Also, check with the manufacturer to be sure the
device has compatible drivers for the version of Windows on your computer. For example, the Schick CDR 2000 sensors
only have native drivers available for 32 bit machines. For these sensors to work in DEXIS and in 64 a bit environment
the CDR Intraoral TWAIN Drivers must be obtained and installed.

Install DEXIS on the Workstation


Once all system specs and Hardware compatibility have been check and verified to meet requirements, installation of
the DEXIS Imaging Suite on the workstation can begin by following these steps:

1. Log on to the server computer as Administrator; Administrator rights are required to complete the install.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 1


DX50650714REV0
2. Close all other programs.

3. Verify the workstation has access to the Data on the server.


a. This can be done using a UNC path
OR
b. By mapping a drive to the ‘Data’ folder on the server.

4. Insert the DEXIS Software


Installation-DEXIS Imaging
Suite installation DVD into the
DVD drive. The DVD should start
automatically. If not, the installer
can be launched by clicking on
My Computer, opening the DVD
drive folder, and double-clicking
DEXMenu.exe.

5. From the menu, click on the


desired language version:
English – US, English –
International (which uses the
international tooth numbering
system) or French – CA /
Français. For this document, we
will use the English – US version.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 2


DX50650714REV0
6. Click on Install DEXIS Imaging
Suite.

7. A reminder that backups should


be run prior to the install will
appear. If you have performed a
complete backup as part of the
server installation, click OK to
move forward.

8. The InstallShield Wizard will


start and the Welcome screen
will appear.

9. Click Next, and the End User


License Agreement (EULA)
appears.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 3


DX50650714REV0
10. After reviewing the EULA,
select I accept… and click
Next to continue.

11. A new window appears and


gives the options of performing a
Server and Workstation or
a Workstation installation.
Select Workstation and click
Next.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 4


DX50650714REV0
12. The next screen will give the
option to select where the
software will be installed. The
default location for software
installation is C:\Program Files\
DEXIS. This path can be changed
by clicking Change and browsing
to the desired location.

Please NOTE: The location


selected must be on a local
drive. Installing to a network
location will not work.

13. With the default path or custom


path set, click Next to continue.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 5


DX50650714REV0
14. The following screen will give
the option to select the location
where the DEXIS data will be
stored. The default location for
this data is C:\DEXIS Imaging
Suite\Data. This path can
also be customized by
clicking Browse and selecting
the desired location. This path
should be changed to point to
the data folder on the server.

15. With the data location set,


click Next to continue.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 6


DX50650714REV0
16. Now that all the paths have been
set, the installation can begin;
click Install.

17. The InstallShield Wizard will


now run all software installations
as well as any component
updates that are needed to
utilize DEXIS Imaging Suite.

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 7


DX50650714REV0
18. Once complete, the option to
restart now or later will be given.
The computer must be rebooted
to complete the install. Remove
the DEXIS Software Installation-
DEXIS Imaging Suite installation
DVD from the DVD drive, select
yes, I want to restart my
computer now and click FINISH.

19. The system will reboot. Once


Windows is loaded the DEXIS
imaging Suite icon will now show
on the desktop .

20. Double-click the icon to verify


that the program launches.

Please NOTE: C
 linicians should review the Manual for the Indications for Use/Intended Use prior to using
DEXIS Imaging Suite.

Where to go for help


DEXIS has created Quick Reference Guides for other installations and setups. Please refer to www.dexis.com under
Get Support a Quick Reference Guides to find a complete list of these guides. There are other resources on the
Get Support page, as well.

You may contact DEXIS Technical Support via phone at 888-883-3947, Option 1, or by email at [email protected].

DEXIS Customer Care Center  Tel  888-883-3947 | Fax  888-833-3947 | www.dexis.com 8