Technical Report: (7620) 350-0024: Consumer Products Services Division
Technical Report: (7620) 350-0024: Consumer Products Services Division
Technical Report: (7620) 350-0024: Consumer Products Services Division
EDGAR EDUARDO
INDUSTRIAS PLASTICAS INTERNACIONALES S.A. DE C.V. ATTN:
CARBAJAL ALEGRIA
MONTE ELBRUZ 132 702 CC: /
CHAPULTEPEC MORALES, CIUDAD DE MÉXICO
This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report
at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use.
Bureau Veritas Consumer Products Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our
Services Mexico S.A. de C.V. prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or
Circuito del Sol 3905-1 Col. Nuevo any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the
Amanecer Puebla Mexico, 72400 results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for
Phone / Fax 52 01 222 2660561 accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall speci fically
website: www.cps.bureauveritas.com address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance
of the completeness of this report, the tests conducted and the correctness of the report contents.
Technical Report: (7620)350-0024
Date of Issue: January 22, 2021
Page 2 of 4
EXECUTIVE SUMMARY:
The results of the tests performed are presented in the next section evaluated as DATA:
* “Bureau Veritas CPS Mexico used an approved subcontractor for this evaluation, the client was notified about this
procedure and obtained the client´s written approval”
RESULTS:
1) SPECIFIC MIGRATION OF HEAVY METALS FOR PLASTIC MATERIALS IN CONTACT WITH FOODSTUFFS –
COMMISSION REGULATION (EU) NO. 10/2011 AND ITS AMENDMENTS
Method: EN 13130-1: 2004 and analysis by Inductively Coupled Argon Plasma Spectrometer (ICP).
Remark: 1) The migration test is carried out according to EC Regulation No. 10/2011 and the corresponding regulatory
statutes.
2) For article intended for single use, only single determination is carried out in the migration tests and the test
result is shown in result table.
3) Selected test was specified by client.
Technical Report: (7620)350-0024
Date of Issue: January 22, 2021
Page 4 of 4
Test Conditions
Water Vapor
Transmission Rate Steady State or Test
Sample Description Rating
2 Duration*
Replicate g/(m .day)
NOTE: Above sample was analyzed on a Permatran-W Water Vapor Permeability Instrument, following the testing
procedure written within QMS 702-004. *If Steady State has not been reached, then the transient data point (normally at
120 hours unless additional time has been purchased) will be reported. To convert the above results to 100 in 2/day,
divide the above values by 15.5. The results relate only to the specific items tested.