AF16Z-40-00-21 24-60V50/60HZ 20-60VDC Contactor: Product-Details

The AF16Z-40-00-21 is a 4 pole contactor that controls motors up to 7.5 kW and switches power circuits up to 30A. It has a wide control voltage range of 24-60V 50/60Hz and 20-60V DC. It is compact and has built-in surge protection. Its technical specifications include rated operational currents up to 30A and breaking capacities up to 250A.

Uploaded by

Sujoy Paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views6 pages

AF16Z-40-00-21 24-60V50/60HZ 20-60VDC Contactor: Product-Details

The AF16Z-40-00-21 is a 4 pole contactor that controls motors up to 7.5 kW and switches power circuits up to 30A. It has a wide control voltage range of 24-60V 50/60Hz and 20-60V DC. It is compact and has built-in surge protection. Its technical specifications include rated operational currents up to 30A and breaking capacities up to 250A.

Uploaded by

Sujoy Paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

PRODUCT-DETAILS

AF16Z-40-00-21
AF16Z-40-00-21 24-60V50/60HZ 20-60VDC
Contactor

General Information
Extended Product Type AF16Z-40-00-21
Product ID 1SBL176201R2100
EAN 3471523115910
Catalog Description AF16Z-40-00-21 24-60V50/60HZ 20-60VDC Contactor
The AF16Z-40-00-21 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals,
controlling motors up to 7.5 kW / 400 V AC (AC-3) and switching power circuits up to 30 A
(AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide
control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage
Long Description
variations, reducing panel energy consumptions and ensuring distinct operations in unstable
networks. Furthermore, surge protection is built-in, offering a compact solution. AF
contactors have a block type design, can be easily extended with add-on auxiliary contact
blocks and an additional wide range of accessories.

Ordering
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Popular Downloads
Instructions and Manuals 1SBC101027M6801
CAD Dimensional 2CDC001079B0201
Drawing
AF16Z-40-00-21 2

Dimensions
Product Net Width 45 mm
Product Net Depth / 77 mm
Length
Product Net Height 86 mm
Product Net Weight 0.31 kg

Technical
Number of Main Contacts 4
NO
Number of Main Contacts 0
NC
Number of Auxiliary 0
Contacts NO
Number of Auxiliary 0
Contacts NC
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°
14
Rated Operational Voltage Main Circuit 690 V
Rated Frequency (f) Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Thermal Current (I th )

Rated Operational Current (690 V) 40 °C 30 A


AC-1 (I e ) (690 V) 60 °C 30 A
(690 V) 70 °C 26 A
Rated Operational Current (415 V) 60 °C 18 A
AC-3 (I e ) (440 V) 60 °C 18 A
(500 V) 60 °C 15 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power (400 V) 7.5 kW
AC-3 (P e ) (415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated Short-time at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
Withstand Current Low at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
Voltage (I cw ) at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical (AC-1) 600 cycles per hour
Switching Frequency
Rated Operational Current (110 V) 1-Pole, 40 °C 20 A
DC-1 (I e ) (110 V) 1-Pole, 60 °C 20 A
(110 V) 1-Pole, 70 °C 20 A
(110 V) 2 Poles in Series, 40 °C 30 A
(110 V) 2 Poles in Series, 60 °C 30 A
(110 V) 2 Poles in Series, 70 °C 26 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 20 A
(220 V) 2 Poles in Series, 60 °C 20 A
(220 V) 2 Poles in Series, 70 °C 20 A
(220 V) 3 Poles in Series, 40 °C 30 A
(220 V) 3 Poles in Series, 60 °C 30 A
(220 V) 3 Poles in Series, 70 °C 26 A
(220 V) 4 Poles in Series, 40 °C 30 A
(220 V) 4 Poles in Series, 60 °C 30 A
(220 V) 4 Poles in Series, 70 °C 26 A
AF16Z-40-00-21 3

(440 V) 4 Poles in Series, 40 °C 20 A


(440 V) 4 Poles in Series, 60 °C 20 A
(440 V) 4 Poles in Series, 70 °C 20 A
(72 V) 1-Pole, 40 °C 30 A
(72 V) 1-Pole, 60 °C 30 A
(72 V) 1-Pole, 70 °C 26 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
(72 V) 4 Poles in Series, 40 °C 30 A
(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Rated Operational Current (110 V) 1-Pole, 40 °C 8 A
DC-3 (I e ) (110 V) 1-Pole, 60 °C 8 A
(110 V) 1-Pole, 70 °C 8 A
(110 V) 2 Poles in Series, 40 °C 30 A
(110 V) 2 Poles in Series, 60 °C 30 A
(110 V) 2 Poles in Series, 70 °C 26 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 8 A
(220 V) 2 Poles in Series, 60 °C 8 A
(220 V) 2 Poles in Series, 70 °C 8 A
(220 V) 3 Poles in Series, 40 °C 30 A
(220 V) 3 Poles in Series, 60 °C 30 A
(220 V) 3 Poles in Series, 70 °C 26 A
(220 V) 4 Poles in Series, 40 °C 30 A
(220 V) 4 Poles in Series, 60 °C 30 A
(220 V) 4 Poles in Series, 70 °C 26 A
(440 V) 4 Poles in Series, 40 °C 8 A
(440 V) 4 Poles in Series, 60 °C 8 A
(440 V) 4 Poles in Series, 70 °C 8 A
(72 V) 1-Pole, 40 °C 30 A
(72 V) 1-Pole, 60 °C 30 A
(72 V) 1-Pole, 70 °C 26 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
(72 V) 4 Poles in Series, 40 °C 30 A
(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Rated Operational Current (110 V) 1-Pole, 40 °C 4 A
DC-5 (I e ) (110 V) 1-Pole, 60 °C 4 A
(110 V) 1-Pole, 70 °C 4 A
(110 V) 2 Poles in Series, 40 °C 20 A
(110 V) 2 Poles in Series, 60 °C 20 A
(110 V) 2 Poles in Series, 70 °C 20 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 4 A
(220 V) 2 Poles in Series, 60 °C 4 A
(220 V) 2 Poles in Series, 70 °C 4 A
(220 V) 3 Poles in Series, 40 °C 16 A
(220 V) 3 Poles in Series, 60 °C 16 A
(220 V) 3 Poles in Series, 70 °C 16 A
(220 V) 4 Poles in Series, 40 °C 20 A
(220 V) 4 Poles in Series, 60 °C 20 A
(220 V) 4 Poles in Series, 70 °C 20 A
(440 V) 4 Poles in Series, 40 °C 4 A
(440 V) 4 Poles in Series, 60 °C 4 A
(440 V) 4 Poles in Series, 70 °C 4 A
(72 V) 1-Pole, 40 °C 16 A
(72 V) 1-Pole, 60 °C 16 A
(72 V) 1-Pole, 70 °C 16 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
AF16Z-40-00-21 4

(72 V) 4 Poles in Series, 40 °C 30 A


(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Rated Insulation Voltage acc. to IEC 60947-4-1 690 V
(U i ) acc. to UL/CSA 600 V

Rated Impulse Withstand 6 kV


Voltage (U imp )

Maximum Mechanical 3600 cycles per hour


Switching Frequency
Rated Control Circuit 50 Hz 24 ... 60 V
Voltage (U c ) 60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Operate Time Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not 2 x M4 screws placed diagonally
supplied)
Connecting Capacity Main Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Circuit Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Rigid Solid 1/2x 1 ... 2.5 mm²
Auxiliary Circuit Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Control Circuit Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length Control Circuit 10 mm
Main Circuit 10 mm
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type Screw Terminals

Technical UL/CSA
General Use Rating (600 V AC) 30 A
UL/CSA
Connecting Capacity Main Rigid Solid 1/2x 16-10 AWG
Circuit UL/CSA Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Rigid Solid 1/2x 18-14 AWG
Auxiliary Circuit UL/CSA Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Rigid Solid 1/2x 18-14 AWG
Control Circuit UL/CSA Rigid Stranded 1/2x 18-14 AWG
Tightening Torque Control Circuit 11 in·lb
UL/CSA Main Circuit 13 in·lb

Environmental
Ambient Air Temperature Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand Category B according to IEC 60947-1 Annex Q
Maximum Operating Without Derating 3000 m
Altitude Permissible
Resistance to Vibrations 5 ... 300 Hz 4 g closed position / 2 g open position
acc. to IEC 60068-2-6
Resistance to Shock acc. Closed, Shock Direction: B1 25 g
to IEC 60068-2-27 Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
AF16Z-40-00-21 5

RoHS Status Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)


ABS Certificate ABS_20-2060694-PDA
BV Certificate BV_2634H24898B0
CB Certificate CB_SE-108879
CCC Certificate CCC_2010010304445624
CQC Certificate CQC2010010304445624
CQC2020010304298240
Declaration of Conformity 2020980304001253
- CCC 2020980304001082
Declaration of Conformity 1SBD250001U1000
- CE
Declaration of Conformity 1SBD250032U1000
- UKCA
EAC Certificate EAC_RU_FRME77B03447
Environmental Information 1SBD250147E1000
GL Certificate DNV-GL_TAE00001AF-3
GOST Certificate GOST_POCCFR.ME77.B07175.pdf
Instructions and Manuals 1SBC101027M6801
KC Certificate KC_HW02016-15008C
LR Certificate LRS_1300087E1
REACH Declaration 2CMT2021-006202
RINA Certificate RINA_ELE240318XG
RMRS Certificate RMRS_1802705280
RoHS Information 2CMT2021-006277
UL Certificate UL-US-L319322-13-72119002-3
UL-CA-L319322-43-72119002-3
UL Listing Card UL_E319322

Container Information
Package Level 1 Units box 1 piece
Package Level 1 Width 87 mm
Package Level 1 Depth / 79 mm
Length
Package Level 1 Height 47 mm
Package Level 1 Gross 0.31 kg
Weight
Package Level 1 EAN 3471523115910
Package Level 2 Units box 27 piece
Package Level 2 Width 250 mm
Package Level 2 Depth / 300 mm
Length
Package Level 2 Height 315 mm
Package Level 2 Gross 16.74 kg
Weight
Package Level 3 Units 1296 piece

Classifications
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
AF16Z-40-00-21 6

ETIM 6 EC000066 - Power contactor, AC switching


ETIM 7 EC000066 - Power contactor, AC switching
ETIM 8 EC000066 - Power contactor, AC switching
eClass V11.0 : 27371003
UNSPSC 39121529
IDEA Granular Category 4758 >> Iec Contactors
Code (IGCC)
E-Number (Finland) 3706340
E-Number (Sweden) 3211396

Categories

Low Voltage Products and Systems → Control Products → Contactors → Block Contactors