Vertical stage−casing low−pressure pumps CVFV

Application Hydraulic part is represented by centrifugal single− or multista−


ge pump with shrouded impellers being sealed with replace−
Vertical pumps CVFV are intended for pumping drinking and
able wear ring on the suction side.
service water or even slightly polluted or turbid water contain−
Shaft is supported on journal bearings, lubricated with a pump−
ing 5 g sludge or further impurities a litre water, with max. grain
ed water.
size 0.5 mm.
Max. temperature of a pumped water ...............................60 °C Column pipe connecting the hydraulic part with the branch
Permissible pH values of a pumped water ................. 6 − 11 pH elbow and bearing suspension is of steel flanged pipes where
Pumps may be applied to water management industry, water the pump−set is carried in. Shaft is supported on guide bear−
supply services and technological processes of various indu− ings. Guide bearings in the piping wet parts are of rolling−con−
strial duties and further plants requiring water supply. tact type, grease−lubricated.
There is soft cord−type packing being placed in the branch el−
Construction bow.
According to their constructional arrangements those pumps
are produced in following workmanships: Bearing suspension bears the pump−set weight, inclusive of
Wet sump version − basic workmanship for direct pumping the electric motor one and further, it may take up the rotor axial
from a water supply, with arrangement of discharge branches forces through a rolling−contact bearing, that may be oiled or
TEE − under the machine room floor and/or TEV − above the greased.
machine room floor.
Wet sump version with an intermediate floor − for buildings Material options
where it is necessary to consider increasing water level in Pump main parts are of following constructional materials:
a sump and flooding the space below the floor, there the pump Option „LN“
is provided with a special intermediate floor closure for max. Suction and discharge cover − grey cast iron
upward pressures up to 4 bar. The closure is fixed, together Stage casing − grey cast iron
with sealing it incorporates even the stator anchorage at the Branch elbow − grey cast iron
intermediate floor. On the closure there is the discharge branch Guide−vaned casing, diffusers − grey cast iron
TEE placed. Impellers, wear rings − grey cast iron
Dry sump version − to make placing it in a separate „dry“ sump Shaft − carbon steel
possible (with pumping from separate water spaces) the pump Shaft sleeves − stainless steel
may be supplied with a foot−type suction elbow of a special Journal guide bearings − steel and bearing rubber
construction. The suction elbow sits at the bottom of the pump Guide pipes − steel
sump on adjustable supports facilating both dismantling and
access to the pump−set hydraulic part in the sump itself. Arran− Material option „LU“
gement of discharge branches may be both TEE and TEV. Impellers are of chrome steel, materials of further parts are the
same as with the „LN“ option.
Pump−set consists of following main parts:
● hydraulic part − the pump itself
● column pipe
● branch elbow
● thrust/suspension bearing
● electric motor
Vertical stage−casing low−pressure pumps CVFV

Section through pump with dis− Broken−out section through pump with
charge branch under floor − TEE discharge branch above floor − TEV

MOTOR MOTOR 341


360.1
341

323
840
840
360.1 526
507
636 526
323
507 350 452 636
636
529.5 350

461
451
213 711 213
711
115
301
321
360.3

452 461

451 144

529.5

212.3
212.1
106 Suction cover 461 Gland packing
545.4 529.4 107 Discharge casing 502 Wear ring
108 Stage casing 507 Thrower
115 Suspension body 526 Bearing hub
383 711 144 Branch elbow 529.1 Shaft sleeve, suction side
171 Diffuser 529.2 Spacer bush
211 Pump shaft 529.3 Shaft sleeve, discharge side
852 212.1 Shaft of column pipe 529.4 Shaft sleeve
212.3 Shaft of branch elbow 529.5 Stuffing box bush
211 213 Suspension shaft 529.5 Stuffing box bush
230 Impeller 545.1 Bearing of suction cover
545.3 301 Rolling−contact bearing housing 545.2 Stage bush
529.3 321 Radial ball bearing 545.3 Bearing of discharge casing
107 323 Thrust ball bearing 545.4 Column pipe bearing
230
341 Lantern bracket 636 Lubricating nipple
529.2 350 Bearing housing 711 Column
502 360.1 Thrust bearing cover 840 Coupling
108 360.3 Radial/journal bearing cover 852 Screwed coupling
905 383 Sliding guide bearing 905 Connection bolt
230 451 Stuffing box insert 920 Shaft nut
171 545.2 452 Stuffing box gland

106 920

529.1 545.1
Vertical stage−casing low−pressure pumps CVFV

Selection chart of pumps

H [m] n = 980 min−1


150

100 16
18
75
15
17
14
50 8
13
40
7
12
30
6
11
5
20
10
4
15
9
3

10
2

7,5
1

5
20 30 40 50 75 100 150 200 300 400 500 750 1000 1500
Q [l.s−1]

1 150−CVFV−265/1 5 350−CVFV−460/1 9 150−CVFV−265/2 13 350−CVFV−460/2 17 350−CVFV−460/3


2 200−CVFV−305/1 6 400−CVFV−530/1 10 200−CVFV−305/2 14 400−CVFV−530/2 18 400−CVFV−530/3
3 250−CVFV−350/1 7 500−CVFV−600/1 11 250−CVFV−350/2 15 500−CVFV−600/2
4 300−CVFV−400/1 8 600−CVFV−700/1 12 300−CVFV−400/2 16 600−CVFV−700/2

H [m] n = 1450 min−1


100

75

11
50
10
40

9
30
3

2
20

1
15

10

7,5

5
20 30 40 50 75 100 150 200 300 400 500 750 1000
Q [l.s−1]
Vertical stage−casing low−pressure pumps CVFV

Technical and design data


Max. face−to−face Moment
Pump Speed Number Discharge dimension L (m) of inertia (kgm2) Weight
model of stages branch versions TEE, TEV
1 m of 1m 1 m of
Version Version pump + pump suspension suspension of piping suction suction
min−1 DN/PN elements’
TEE TEV suspension shaft UV UP (shaft + pipe) strainer pipe
1 150/10 21 21 0,145 0,0010 166 217 256 27
980
2 150/10 21 21 0,312 0,0010 282 224 253 27
150−CVFV− 72 56
−265−35 1 150/10 21 21 0,158 0,0010 166 217 246 27
1450
2 150/10 21 21 0,322 0,0010 282 224 253 27

1 200/10 19,5 19,5 0,178 0,0010 193 222 345 60


980
2 200/10 20 20 0,363 0,0010 325 240 360 60
200−CVFV− 75 52
−305−40 1 200/10 19,5 19,5 0,192 0,0010 193 250 360 60
1450
2 200/10 20 20 0,376 0,0020 235 265 375 62

1 250/10 21 19 0,473 0,0016 265 390 615 71


680
250−CVFV− 2 250/10 21 19,5 0,773 0,0016 457 390 615 71
83 67
−350−46
1 250/10 21 19 0,488 0,0016 265 390 615 71
1450
2 250/10 21 19,5 0,843 0,0048 457 435 670 79,5

300−CVFV− 1 300/10 21 20 0,731 0,0020 390 440 695 94,5


980 83 87
−400−52 2 300/10 21,5 20 1,304 0,0034 669 505 870 97

1 350/10 21 20,5 1,360 0,0026 576 630 885 122


350−CVFV− 980 2 350/10 21,5 21 2,830 0,0100 1019 840 1185 131 110 122
−460−59 3 350/10 22 21 3,950 0,0100 1463 840 1185 131

1 400/10 22 20 2,840 0,0086 811 850 1123 126


400−CVFV−
980 2 400/10 22,5 20,5 5,010 0,0150 1428 980 1325 126 155 109
−530−68
3 400/16 23 21 7,270 0,0250 1921 996 1678 126

500−CVFV− 1 500/10 21,5 21 5,520 0,0150 1215 900 1260 165


980 155 111
−600−78 2 500/16 22 21,5 10,790 0,0390 2138 1080 1460 177

600−CVFV− 1 600/10 22 20,5 10,490 0,0300 1539 1827 2123 298


980 2 600/16 22,5 21 18,430 0,0550 2758 1857 2144 298 190 229
−700−90
Vertical stage−casing low−pressure pumps CVFV

Basic version Version into dry Version into wet sump


into wet sump sump with intermediate floor

CONNECTING DIMENSIONS X
U1

T1

V1

Z HOLE FOR FOUNDATION FRAME Y Z


P
G

G
M
N

Y Y

D1 D1
P
L1

L1
P M P
TUK

TUK
N
B B
CONNECTING DIMENSIONS Z
D

D
T

h
S
R

G1
L

L
L2

L2
S
U
R V
D2 D2

E
E E
A
A

A
H

H
H

D3 D3 D3
L3

L3
L3

D4
K
C

C
J

F F
Vertical stage−casing low−pressure pumps CVFV

Dimensions of pumps with discharge branch TEE


Pump
150−CVFV 200−CVFV 250−CVFV 300−CVFV 350−CVFV 400−CVFV 500−CVFV 600−CVFV
model
of stages
Number

1 376 418 458 543 640 735 830 860


A 2 553 622 691 808 945 1085 1230 1313
3 − − − − 1250 1435 − −
B 200 280 300 350 400 500 650 700
C 450 450 500 670 670 754 754 870
D DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500 DN 600
D1 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500 DN 600
D2 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500 DN 600
D3 DN 200 DN 200 DN 250 DN 300 DN 350 DN 400 DN 400 DN 500
D4 DN 200 DN 200 DN 250 DN 400 DN 400 DN 500 DN 500 DN 700
∅E 554 635 714 790 930 1030 1200 1380
∅F 440 440 520 504 504 605 605 775
G 180 180 200 220 250 250 250 280
G1 160 180 200 220 230 230 230 280
H 290 320 340 410 480 540 610 780
h 250 290 340 400 400 460 500 640
I 300 300 350 500 500 600 600 800
J 220 220 250 370 350 450 450 580
K 300 300 350 500 500 600 600 800
L1 + L2 + A + L3 + C Basic version and with intermediate floor
L
L1 + L2 + A + L3 + K + J Version for dry sump

1185 3185 1235 3235 1285 3285 1280 3280 1280 3280 1310 3310 1420 3420
L1 1685 3685 1735 3735 1785 3785 1780 3780 1780 3780 1810 3810 1920 3920
2185 4185 2235 4235 2285 4285 2280 4280 2280 4280 2310 4310 2420 4420
2685 4685 2735 4735 2785 4785 2780 4780 2780 4780 2810 4810 2920 4920

1220 5720 1255 5755 1300 5800 1355 5855 1350 5850 1400 5900 1440 5940 1560 6060
1720 6220 1755 6255 1800 6300 1855 6355 1850 6350 1900 6400 1940 6440 2060 6560
2220 7220 2255 7255 2300 7300 2355 7355 2350 7350 2400 7400 2440 7440 2560 7560
2720 8220 2755 8255 2800 8300 2855 8355 2850 8350 2900 8400 2940 8440 3060 8560
L2 3220 9220 3255 9255 3300 9300 3355 9355 3350 9350 3400 9400 3440 9440 3560 9560
3720 10220 3755 10255 3800 10300 3855 10355 3850 10350 3900 10400 3940 10440 4060 10560
4220 11220 4255 11255 4300 11300 4355 11355 4350 11350 4400 11400 4440 11440 4560 11560
4720 12220 4755 12255 4800 12300 4855 12355 4850 12350 4900 12400 4940 12440 5060 12560
5220 13220 5255 13255 5300 13300 5355 13355 5350 13350 5400 13400 5440 13440 5560 13560
250 1250 250 1250 250 1250 250 1250 250 1250 250 1250 250 1250
500 1500 500 1500 500 1500 500 1500 500 1500 500 1500 500 1500
L3
750 2000 750 − 750 2000 750 2000 750 2000 750 2000 750 2000
1000 − 1000 − 1000 − 1000 − 1000 − 1000 − 1000 −
M 650x650 700x700 800x800 900x900 1000x1000 1300x1300 1300x1300 1450x1450
N 900x900 1000x1000 1150x1150 1300x1300 1300x1300 1650x1650 1650x1650 2000x2000
P 125 150 175 200 150 175 175 275
R 760x760 810x810 920x920 1040x1040 1140x1140 1440x1440 1440x1440 1600x1600
S 710x710 760x760 850x850 960x960 1080x1080 1360x1360 1360x1360 1530x1530
∅T 8x∅18 8x∅23 8x∅23 8x∅23 8x∅27 8x∅30 8x∅30 8x∅32
∅T1 12x∅18 12x∅23 12x∅23 12x∅23 12x∅27 12x∅30 12x∅30 12x∅30
∅U 650 700 800 900 1000 1300 1300 1520
∅V 900 1000 1150 1130 1400 1650 1650 2000
∅U1 710 770 900 960 1080 1370 1360 1620
∅V 1 740 810 960 1040 1150 1440 1450 1700

Dimensions are in mm.


Dimensions pre−sized but not given there are variable as they depend on an electric motor type and size. They may be given on request with a real business.
Connecting dimensions of the pump suction branch flange are intended for PN 10.
Connecting dimensions of the discharge branch elbow flange are intended for PN − given in the Table „Technical and design data“.
L3 ......... using a suction pipe individually, for lenghtening the pump total face−to−face dimension.
H ....... minimal „on“ level necessary within the pump starting−up for its thorough flooding and reliable operation.
Vertical stage−casing low−pressure pumps CVFV

Version for wet sump


with branch TEV

D
U h
G
V L2
D2
L

E
A
H

D3
L3
C

CONNECTING DIMENSIONS Z
U1
T

V1
Vertical stage−casing low−pressure pumps CVFV

Dimensions of pumps with discharge branch TEV


Pump
150−CVFV 200−CVFV 250−CVFV 300−CVFV 350−CVFV 400−CVFV 500−CVFV 600−CVFV
model
of stages
Number

1 376 418 458 543 640 735 830 860


A 2 553 622 691 808 945 1085 1230 1313
3 − − − − 1250 1435 − −
B 340 350 420 450 500 650 650 710
C 450 450 500 670 670 754 754 870
D DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500 DN 600
D1 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500 DN 600
D3 DN 200 DN 200 DN 250 DN 300 DN 350 DN 400 DN 400 DN 500
∅E 554 635 714 790 930 1030 1200 1380
∅F 440 440 520 504 504 605 605 775

G 160 180 200 220 230 250 230 280

H 290 320 340 410 480 540 610 780


h 180 210 240 280 300 340 420 540

L L 2 + A + L3 + C

970 6970 965 6965 960 6960 955 6955 950 6950 940 6940 940 6940 930 6930
1470 7970 1465 7965 1460 7960 1455 7955 1450 7950 1440 7940 1440 7940 1430 7930
1970 8970 1965 8965 1960 8960 1955 8955 1950 8950 1940 8940 1940 8940 1930 8930
2470 9970 2465 9965 2460 9960 2455 9955 2450 9950 2440 9940 2440 9940 2430 9930
2970 10970 2965 10965 2960 10960 2955 10955 2950 10950 2940 10940 2940 10940 2930 10930
L2 3470 11970 3465 11965 3460 11960 3455 11955 3450 11950 3440 11940 3440 11940 3430 11930
3970 12970 3965 12965 3960 12960 3955 12955 3950 12950 3940 12940 3940 12940 3930 12930
4470 13970 4465 13965 4460 13960 4455 13955 4450 13950 4440 13940 4440 13940 4430 13930
4970 14970 4965 14965 4960 14960 4955 14955 4950 14950 4940 14940 4940 14940 4930 14930
5470 15970 5465 15965 5460 15960 5455 15955 5450 15950 5440 15940 5440 15940 5430 15930
5970 16970 5965 16965 5960 16960 5955 16955 5950 16950 5940 16940 5940 16940 5930 16930
250 1250 250 1250 250 1250 250 1250 250 1250 250 1250 250 1250
500 1500 500 1500 500 1500 500 1500 500 1500 500 1500 500 1500
L3
750 2000 750 − 750 2000 750 2000 750 2000 750 2000 750 2000
1000 − 1000 − 1000 − 1000 − 1000 − 1000 − 1000 −

∅T1 10x∅18 10x∅23 10x∅23 10x∅23 10x∅27 10x∅30 10x∅30 14x∅30


∅U 650 700 800 900 1000 1300 1300 1520
∅V 900 1000 1150 1130 1400 1650 1650 2000
∅U1 710 770 900 960 1080 1370 1360 1620
∅V 1 740 810 960 1040 1150 1440 1450 1700

Dimensions are in mm.


Dimensions pre−sized but not given there are variable as they depend on an electric motor type and size. They may be given on request with a real business.
Connecting dimensions of the discharge branch elbow flange are intended for PN − given in the Table „Technical and design data“.
L3 ......... using a suction pipe individually, for lenghtening the pump total face−to−face dimension.
H ....... minimal „on“ level necessary within the pump starting−up for its thorough flooding and reliable operation.