EZTAG3 | PROXIMITY AND KEYPAD DOOR ENTRY

USER MANUAL

www.espuk.com

EZTAG3 Manual_Layout 1.indd 1 18/11/2016 15:28:04


System Components

Proximity and Keypad Reader 10 x Proximity Tags 1 x Hex Key


4 x Plastic wall plug
4 x Countersunk screws
1 x Diode and 1 x Capacitor

Optional Accessories

EVBPSBB EV-EXIT EV-EBG EV-ML-250/500XT ENTERD


Lock Power Supply Push to Release Emergency Release Electro-magnetic Lock Electric Lock

EZTAG3 Manual_Layout 1.indd 2 18/11/2016 15:28:07


Contents
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
EZTAG3 Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
EZTAG3 Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Advanced Programming Guide


How to set-up Access Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . 6
How to set-up Access Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Deleting Access Pin or Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Changing Programming Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Clear all Pin and Tag Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Default to Factory Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Lock 1 Output Operating Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enable ‘Door Bell’ Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enable ‘Tamper Alarm’ facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Access Pin Number for Lock 2 Output . . . . . . . . . . . . . . . . . . . . . 10
Deleting Access Pin for Lock 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Lock Output Operating Time for Lock 2 Output. . . . . . . . . . . . . . 11

System setup record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12


User Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
ck

EZTAG3 Manual_Layout 1.indd 3 18/11/2016 15:28:07


Installation

Release hex screw from (Side View)


the bottom of the keypad Push the keypad up to release from mount plate

Thread system cable through the cable entry hole then make
the system connections (as per the wiring diagram), mount the
bracket to the surface and slide the keypad to the mountplate,
re-fit the hex screw to secure into position.

Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart

EZTAG3 Manual_Layout 1.indd 4 18/11/2016 15:28:07


EZTAG3 Wiring Example 1
Indication LEDs Electro-magnetic lock Electronic lock
_
Capacitor for +
Electro-magnetic lock
Diode for
Electronic Lock
Lock -release time

NC N.C for
Keypad

4
3 Electro-magnetic lock
+
_ N.O for
Electronic lock
Red
+
Black _
Green
Purple
Grey
Pink

Tag Reader

EZTAG3 Wiring Example 2


Indication LEDs
Red
Input DC: +12V - +24V
Black or
Input AC: 12V - 24V
Green N.O
Output for
Purple COM Lock 1
(Volt-free)
Blue N.C
Keypad

Grey
Orange Push button
P.b for Lock 2 for Lock 1
Pink (N.O) (N.O)

Green/White N.O
Purple/White Output for
COM Lock 2
Blue/White N.C (Volt-free)

Yellow
Speaker connection
+ for ‘door bell’ facility
White
_ (8Ω 0.5w recommended)
Tag Reader

EZTAG3 Manual_Layout 1.indd 5 18/11/2016 15:28:09


How to set-up Access Pin Number
Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 9

Long
3 0 2 Tone

Enter a starting Double


4 0 0 0 9 9 9
location number Tone

5 ? ? ? ? Enter a 4 digit pin Long


(1234 not be used)
Tone

6 # # To end programming

How to set-up Access Tags


Step Keypad
Number Action Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 9
Long
3 0 5 Tone

Enter a unused Long


4 0 0 0 9 9 9
location number* Tone

5 Enter number of
? ? ? tags to be registered
Tone

Present the tag with the Tone


6
lowest serial number

All other batch tags To end


7
will auto register
# # programming
*Each tag will use up a location number

EZTAG3 Manual_Layout 1.indd 6 18/11/2016 15:28:09


Deleting Access Pin or Tag
Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1 Programming (Default) Tone
Enter the location
2 0 0 0 9 9 9
number of tag/pin

3 To delete

4 # # To end programming

Changing Programming Pin


Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 3

3 ? ? ? ? Enter new 4 digit


programming pin
Re-enter new 4 digit Long
4 ? ? ? ? programming pin Tone

5 # # To end programming

Note; To access keypad’s programming mode, the 4 digit


programming code is entered in twice

EZTAG3 Manual_Layout 1.indd 7 18/11/2016 15:28:09


Clear all Pin and Tag Data
Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 8

Long
3 8 8 Tone

4 # # To end programming

Default to Factory Settings


Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 8

Long
3 9 9 Tone

4 # # To end programming

EZTAG3 Manual_Layout 1.indd 8 18/11/2016 15:28:09


Lock 1 Output Operating Time
Step Keypad
Action
Number Indication
1 Enter 1 2 3 4 1 2 3 4 Long
Programming (Default) Tone

2 1

Enter number Long


3 ? ?
of seconds 00-99 Tone

4 # # To end programming

Enable ‘Door Bell’ Facility


Step Keypad
Action
Number Indication
1 Enter 1 2 3 4 1 2 3 4 Long
Programming (Default) Tone

2 2

Long
3 0 2 To enable 0 1 To disable
Tone

4 # # To end programming

Becomes the ‘door bell’ push in normal mode

EZTAG3 Manual_Layout 1.indd 9 18/11/2016 15:28:09


Enable ‘Tamper Alarm’ facility
Step Keypad
Action
Number Indication
1 Enter 1 2 3 4 1 2 3 4 Long
Programming (Default) Tone

2 6

Long
3 0 2 To enable 0 1 To disable
Tone

4 # # To end programming

Tamper alarm activates the keypad’s internal buzzer and


‘door bell’ output if the light sensor is exposed

Access Pin Number for Lock 2 Output


Step Keypad
Action
Number Indication
1 Enter 1 2 3 4 1 2 3 4 Long
Programming (Default) Tone

2 9

Long
3 0 3 Tone

Enter an unused 0 9 Double


4 0 0
location number Tone

5 ? ? ? ? Enter a 4 digit pin


(1234 should not be used)
Long
Tone

6 # # To end programming

10

EZTAG3 Manual_Layout 1.indd 10 18/11/2016 15:28:09


Deleting Access Pin for Lock 2
Step Keypad
Action
Number Indication
Enter 1 2 3 4 1 2 3 4 Long
1
Programming (Default) Tone

2 4

3 Enter the location


number of pin
0 0 0 9

4 To delete

5 # # To end programming

Lock Output Operating Time for Lock 2 Output


Step Keypad
Action
Number Indication
1 Enter 1 2 3 4 1 2 3 4 Long
Programming (Default) Tone

2 5

Enter number Long


3 ? ?
of seconds 00-99 Tone

4 # # To end programming

11

EZTAG3 Manual_Layout 1.indd 11 18/11/2016 15:28:10


To assist in future programming, it is recommended that a
record is made of the system setup.

System Location Tag Serial Tag Owner Notes


Number (000-999) Number

12

EZTAG3 Manual_Layout 1.indd 12 18/11/2016 15:28:10


System Location Tag Serial Tag Owner Notes
Number (000-999) Number

13

EZTAG3 Manual_Layout 1.indd 13 18/11/2016 15:28:10


User Guide
To release Lock 1 To access programming mode
(A) (B)
Enter a programmed Present a 1 2 3 4 1 2 3 4
Access Pin number registered tag (Default)

Technical Specification
DC input 12 - 24volts Working temperature -20c to +50c
AC input 12 - 24volts Reader frequency 125KHz
Standby current 80ma IP rating 65
Operating current (without lock) 110ma Dimension 150 x 44 x 24mm

14

EZTAG3 Manual_Layout 1.indd 14 18/11/2016 15:28:10


15

EZTAG3 Manual_Layout 1.indd 15 18/11/2016 15:28:10


K16

Elite Security Products Telephone: 01527 51 51 50


Unit 7, Target Park, Shawbank Rd Fax: 01527 51 51 43
Lakeside, Redditch B98 8YN email: [email protected]

www.espuk.com

EZTAG3 Manual_Layout 1.indd 16 18/11/2016 15:28:10

You might also like