46BFIELD
46BFIELD
busstop® Overview 2
Connector Specifications 7
Pre-molded Fieldbus Cables 8 1
Part Number Keys 9
PROFIBUS®-PA Overview 47
Cable and Cordsets 52
Junctions (Bricks) 56
Device Glands 62
Terminating Resistors
Tees and Adapters
63 3
65
Surge Suppressor and Lokfast™ Guard 69
Receptacles 71
Field Wireables and Accessories 73
HART® Overview 76
Cable and Cordsets 80
Junctions 86
Device Glands
Tees and Adapters
90
91
4
Receptacles 95
Field Wireables and Accessories 98
Installations 102
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 1
AWorldwide Fieldbus Solution
Worldwide
Interlink BT
BT’’S Fieldbus Connectivity Catalog
InterlinkBT
This catalog covers high quality on-the-machine and at-the-process FOUNDATION™ fieldbus H1, PROFIBUS®-PA
and HART® interconnect products. The product offering emphasizes materials for diverse applications where
aggressive environments are often the norm.
Cable
InterlinkBT® has the products for interconnecting all your devices on a network segment. By simply plugging
components together these products allow for quick installations of new plant layouts and easy alterations to
existing installations. InterlinkBT’s junction blocks are rugged and can be mounted in aggressive environments.
Spur or drop count can vary from 4 to 8 with the choice of minifast® or eurofast® connector sizes.
InterlinkBT® cable exceeds ISA SP50.02 specifications for impedance and attenuation. Pre-molded cordsets are
available with either minifast® or eurofast® connector sizes. The easy-to-use terminating resistor simply screws
into the end of the Home Run cable. You can reliably use InterlinkBT® fieldbus products in the harshest of
environments.
2 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connectors
Not all the I/O in a fieldbus system can be connectorized, but when it can it is extremely effective. A few minutes of
1
layout and bill-of-material planning can replace hours of costly wire installation. In addition, product replacement is
greatly facilitated by using industrial grade quick disconnect plug-and-play receptacles.
InterlinkBT® uses two industrial standardized connectors. The generic names for them are “Mini” and “Micro” or “Euro”.
In one variation or another these two standardized connectors are produced by the thousands. Rough estimates put
the “Mini” style at over 10,000 per day and the “Euro” at over 25,000 per day. They are used in every industry that
requires rugged economic plug-and-play connectorization. Both were standardized by DIN (German Industrial Stan-
dards) in their early design. Today they are recognized standards throughout the world.
The sheer volume means that the build processes for these two standards are understood, tooled, automated and
economical. The volume and breadth of applications means that broad selections of off-the-shelf products are available.
There are three materials for coupling nuts; stainless steel, nylon and nickel-plated brass. The mating pin and sleeves
are gold-plated brass. The body is made of polyurethane and is injection molded to the cable jacket to provide strain
relief and to seal the connections from the atmosphere.
The Mini’s pin and sleeve are rated at 9 amps and the Micro is rated at 4 amps. The designated ground pin of the Mini
family is longer than the other pins, resulting in a make-first/break-last ground. This feature is not explicitly required for IS
or NI applications, but is a sound engineering choice. All the pins of the Euro make and break at the same time during
insertion and removal.
Junction Boxes
The junction boxes shown in this catalog are passive hubs. Although no conditioning or monitoring takes place,
some junctions have short circuit protection. This protects the power on the trunk and allows use in Class 1, Div 2
locations. The boxes are made from two different materials; copper-free die-cast aluminum with a powder coated
enamel finish or polyurethane overmold. Both housings are available with either 316 stainless steel or nickel plated
brass connectors.
The junction boxes are rated NEMA 1, 3, 4, 4X, 12, 13 and IEC IP67. These ratings are conditional, requiring the
cordset or cap to be installed. Although the die cast housing is rated 4X (salt-water spray test) we highly recommend
the polyurethane or fiberglass housing for aggressive environments.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3
Occupants on the Bus
Active Hub - a multiple port repeater or amplifier that lengthens the branching ability of a bus.
Barrier Box - limits current/voltage to an area.
Brick - fully connectorized passive junction.
Bridge - there are two types; one is a double-sided node that connects two segments together that are the same
protocol but different transmission speeds, the other is a smart repeater that only repeats the data between two bus
segments when the source and destination address are in different segments. The bridge must be programmed to
know what the addresses are and their respective segments.
Bus Junction - generic name for a passive hub.
Busline - any group of wires that carries data from node-to-node.
Dropline - a reduced branch (spur) from a trunkline.
Dropline
Gateway - a special node on two different buses that serves as a signal and data translator between the buses.
LAS (Link Active Scheduler) - controls communication on the bus. Creates a token circulation list (Live List) that
defines access on the bus. Devices may only communicate when given access by the LAS unit. Multiple devices may
have LAS capabilities but only one can communicate at a time.
Node - an addressable device on the bus.
Power Conditioner - device used to condition the power to be for a bus segment. Allows power and data to exist
on the same wires.
Repeater - a product that strengthens a signal, while adding up to a half-bit wait state and producing a fresh signal
without distortions. It also links two portions of the same bus together. A repeater is used when a signal is weak or
distorted.
Router - a higher level bridge for connection of wide area networks.
Simple Device - anything that does not have LAS capabilities.
System T Tee
ee - a field wireable tee.
Tee - a product that creates a branch or drop from a bus.
Terminating rresistor
esistor - a resistor that is put at the beginning and end of the main busline to stabilize and minimize
reflections.
Trunk line - the main busline.
To Control Highway
24V 24V
Terminator
Spurs
BRPS-49-M213
JTBS-49SC-M633
Pressure Transmitter
4 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bus Topology
Topology
Topology is a term that applies to buses. It describes how the data lines connect the nodes together. The first bus
goes back to the original telegraph - two data lines hanging on wooden poles going from telegraph station to
1
telegraph station.
Bus - the simple straight-line topology is called a bus. Another term used is “Daisy Chain”, where the trunk simply
runs from device to device.
Branch - a common bus can have branches, and sometimes the branches can have branches. Another term
used to describe the branches is “drops” or “spurs”, as in FOUNDATION™ fieldbus. Depending on the bus the
branches may be restricted to just a few centimeters or a free-form topology with restrictions only on the
cumulative distance of all data lines.
Star - the bus lines radiate from a single point. A junction (either passive or active) looks like a star. FOUNDATION™
fieldbus also refers to this as a “chicken foot” topology with many branches connected in a relatively small area.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 5
Bus Types
Types
There are several different bus types utilizing the following technologies:
Client / Server - upload/download information, setpoint changes, alarm management, remote diagnostics and one to
one communications.
Media Access - this is the “right-of-way” for talking on the bus. There are three main types:
Master Control - one super node controls all transmission, sequence and time. Remaining nodes do not talk
unless told to by the master.
Token Passing - this is a message shift method that is incremented in a manner that allows each node a chance
to talk during each cycle.
CSMA - an access method allowing each node to speak, provided that it has something to say and no other node
is talking on the line.
Message Collision A voidance - when two people talk simultaneously there is a verbal collision. A few humans can
Avoidance
talk and listen to someone else at the same time but nodes cannot. Both token passing and master control do not
have that problem. A field node can only access the bus when it is its turn to talk or when it has been told to talk.
CSMA-type buses do have this problem. The problem goes away when they are operated as a master-to-slave.
When operating in the native CSMA access method two nodes could start talking simultaneously. Two major ways
have been developed to handle a potential collision:
CD - collision detection - all senders must also be receivers. If two nodes start talking at the same time they will
hear a collision. Both stop talking, wait a random length of time, then look for a clear line to start talking
again.
BA - bitwise arbitration - all senders must also be receivers. The busline must be of a specific length or less so
that all nodes hear the bit at the same time (actually the first node and the last node can be approximately
1/6 bit apart).
Messaging - there are three major types in the run mode, but many more during start-up and initialization.
Solicited - a response to another node or a response when it is the node’s predetermined time to speak
(token passing).
Unsolicited - a response to a change-of-state at the node.
Explicit - a command order. It may command an output be turned “On” or “Off”. It may command any node
to report its diagnostic status or identity itself in full detail.
One last distinction must be made for the output nodes. How do they get the information so they know what to do?
Although there is an overlap with the terms used for messaging, there are important differences:
Limited Peer -to-Peer - exclusive one-to-one relationship between the input node and the output node. This could
Peer-to-Peer
also be called exclusive peer-to-peer.
Unlimited Peer-to-Peer - similar to limited peer-to-peer, but the output node may get information from several input
Peer-to-Peer
nodes.
6 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector Specifications
multifast® Connector
- M23 x 1 thread
-100% electrically tested
-Current Rating: 4A
-Voltage Rating: 300V
-Protection: NEMA 1,3,4,6P IEC IP67
-Temperature: -30ºC to +85ºC
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 7
Pre-molded Fieldbus Cables
Pre-molded
Pre-molded fieldbus cables ensure simple and secure wiring of the connected fieldbus components. Time-consuming wiring
of individual components and bus communication problems due to wiring errors or incomplete shielding are eliminated.
Molded polyurethane insulation provides IP67 protection.
Standard lengths of pre-molded cordsets and bulk cable are listed below. Consult the factory for other lengths.
2.5 8.2
3.0 9.8
4.0 13 150 492
5.0 16
6.0 20
8.0 26 225 738
10 33
15 49
20 66 300 984
25 82
30 98
40 131 --- ---
50 164
8 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Part Number Keys
Cordsets
Cordsets
R S C V 49x *M 1
Receptacles
F S F V 49x *M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 9
minifast® Part Number Keys
Cordsets
Cordsets
W K M 4 9x *M
Receptacles
R K F V 4 9x *M
10 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Junction Tee Part Number Key
Tee
JT B S 49 SC M 6 3 3 1
Connector Material
3 = Stainless Steel
4 = Nickel-Plated Brass
Housing
JT = Junction Tee 1 = Aluminum (JBBS only)
2 = Fiberglass (JBBS only)
JB = Junction Box
3 = Polyurethane (JTBS only)
4 = Hytrel (JTBS only)
Number of Ports
4 = 4 ports
6 = 6 ports
8 = 8 ports
Connector Type
Type
Bus System ®
M = minifast
48 = PROFIBUS®-PA E = eurofast ®
49 = FOUNDATION™ fieldbus
Pr otection
Protection
SC = Short Circuit
(Blank) = None
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 11
For HART® Systems Only
H AR
ARTT ® Junction Box Part Number Key
V B M 4 0 H C S V 1 2
12 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
1
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 13
FOUNDATION™ fieldbus Overview
OUNDATION
FOUNDATION™ fieldbus is a communication protocol and defined physical method to interconnect smart devices
such as temperature transmitters, pressure transmitters and valve actuators. The physical layer conforms to ISA
SP50.02 and IEC 1158-2 standards for fieldbuses. In comparison to 4-20 mA loops that only allow for one device
connection per twisted pair, fieldbus technology enables many smart devices to share one communication
medium. The digital communication signal is superimposed onto a DC carrier. This greatly reduces the amount of
terminations needed to connect all the field devices to a host system. It also allows greater flexibility for future
additions of I/O points.
A FOUNDATION™ fieldbus device is addressable and has capabilities to store and transmit data. The devices can
store values, track changes and use pre-set alarms to trigger. Based on pre-defined tag names, host systems can
read transmitter values such as temperature and pressure or set values of a valve actuator.
The digital signal encoding is done using Manchester BiPhase-L and error checking is done with the CRC
method. FOUNDATION™ fieldbus has two types of devices; a Basic Device (BD) and a Link Active Scheduler (LAS).
A Basic Device is designed to read inputs, track values and set outputs if programmed to do so. A LAS device
performs the same features as a BD, however it goes one step further by handling network communication timing
between all the active devices on the network. The LAS essentially creates a time table so that all devices can get
a chance to transmit/receive data on the bandwidth. A fieldbus segment can have many Basic Devices but must
have at least one Link Active Scheduler. At least two LAS devices are recommended on the network to provide
redundancy. If there is more than one LAS on the network, the one that powers-up first gets the LAS designation
and the other LAS unit switches to BD mode of operation.
93.3FM
1 2 3 4 5
Figure11- Parallel
Figure WiringDiagram
Parallel Wiring Diagram
Communication Signal
The FOUNDATION™ fieldbus H1 communication signal is a square waveform superimposed on a DC carrier. The
frequency of the signal is 31.25Khz. Although they do not have to, most devices derive their supply power from
the fieldbus communications cable. The fieldbus specification states that devices must not be polarity sensitive. It
is good electrical practice though to have all devices wired with the same polarities. The voltage range allowed for
proper operation is 9-32 VDC. A typical fieldbus device will consume 20 mA of current.
14 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Star Topology Method
Topology
A star topology has a central connection point for all terminations. This layout works well when there are many
devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker
tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the
fieldbus segment. The best design would be to connect them all to a junction brick and then run a home run cable
from the junction brick back to the control room. See Figur e 2 for a pictorial example.
Figure
2
The Home Run cable is considered the main trunk line for communication. Each device that is connected to the
junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line.
Transmitters
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 15
Fieldbus Cable Specifications
The specifications for fieldbus H1 physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 Physical
Layer Standards. The same standard is also listed in the FOUNDATION™ fieldbus specifications under 31.25 Kbps
Physical Layer Profile FF-816-1.4. There are essentially four types of cable designations for fieldbus. Type A cable is
the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are
for installations where cable already exists from 4-20 mA systems. See T able 1.
Table
InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a
centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.02-
1992, the fieldbus standard for use in industrial control systems.
The maximum spur length is determined by the number of devices in the segment.
25-32 0 m (0 ft)
16 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
F OUNDATION™ fieldbus - Cable Specifications
OUNDATION
1
Our cable meets the requirements of ISA/SP50
and FOUNDATION™ fieldbus requirements for Type
A cable. Cables are available in 3-wire versions 2
with a device ground or 2-wire versions.
Cable Specifications
Type A Cable
- Temperature range: -40 to 105°C (-40 to +221F) 11
- Governed by: ISA SP50.02 specification
- Sunlight resistant
- PLTC and ITC rated (CSA FT4)
- Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20%
- Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km
- Maximum capacitive unbalance to shield = 2 nF/km
- Maximum DC resistance (per conductor) = 24 Ω/km
- Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km
- Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG)
or 1.2 mm2 (#16 AWG)
- Minimum shield coverage shall be 90%
490B NEC ITC PLTC 2/18 AWG 6.5 Ohms 18 AWG PVC Blue Foil
CEC [CMG] RB50783-*M 1
105°C 300V Blue/Brn PE Green/Yellow 7.9mm (.310 in) 20 AWG
492A NEC ITC PLTC/CM 2/18 AWG 6.5 Ohms 18 AWG Armor/PVC Yellow Foil
CEC[CMG HLBCD] Blue/Brn
CEC PE Green/Yellow 12.7mm (0.5 in) RB50874-*M 11
105°C 300V 18 AWG
492BA NEC ITC PLTC/CM 2/18 AWG 6.5 Ohms 18 AWG Armor/PVC Blue Foil
CEC[CMG HLBCD] Blue/Brn
CEC RB50803-*M 11
105°C 300V
PE Green/Yellow 12.7mm (0.5 in) 18 AWG
493 NEC ITC PLTC 2/18 AWG 6.5 Ohms PVC Yellow Foil/Braid
None RB50784-*M 1
105°C 300V
CEC [CMG] Blue/Brn PE 7.9mm (.310 in) 20 AWG
493B NEC ITC PLTC 2/18 AWG 6.5 Ohms PVC Blue Foil/Braid
None RB50786-*M 1
105°C 300V CEC [CMG] Blue/Brn PE 7.9mm (.310 in) 20 AWG
493O NEC ITC PLTC 2/18 AWG 6.5 Ohms None PVC Orange Foil/TC Braid
7.9mm (.310 in.) 20 AWG RB50785-*M 1
105°C 300V CEC [CMG] Blue/Brn PE
496 NEC ITC PLTC 2/16 AWG 4.3 Ohms None PVC Yellow Foil RB50891-*M 1
105°C 300V CEC [CMG] Blue/Brn PE 8.5mm (.335 in.) 20 AWG
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 17
F OUNDATION™ fieldbus - Cable and Cor
OUNDATION dsets
Cordsets
minifast® † eurofast®
Try Cordset Builder Online!
Pin (Male) Socket (Female) Pin (Male)
RSV 49x -*M WSV 49x -*M RKV 49x -*M WKV 49x -*M RSCV 49x -*M
Bare
RSV RSV 49x -*M RSV WSV 49x -*M RSV RKV 49x -*M RSV WKV 49x -*M RSV RSCV 49x -*M
Pin (Male)
RSV
†
WSV WSV 49x -*M WSV RKV 49x -*M WSV WKV 49x -*M WSV RSCV 49x -*M
minifast®
WSV
Socket (Female)
RKV RKV 49x -*M RKV WKV 49x -*M RKV RSCV 49x -*M
RKV
RSCV
eurofast®
WSCV
Socket (Female)
RKCV
WKCV
× Indicates cable type. WSV RSCV 490-1M
* Indicates length in meters.
Consult factory for availability of armorfast® with eurofast® connectors.
† armorfast® cable only - straight only.
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths.
1 METER
Example
18 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
FOUNDATION™ fieldbus - Cable and Cor
OUNDATION dsets
Cordsets
Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female)
2
WSCV 49x -*M RKCV 49x -*M WKCV 49x -*M RSFPV 49x -*M RKFPV 49x -*M FSFDV 49x -*M FKFDV 49x -*M
RSV WSCV 49x -*M RSV RKCV 49x -*M RSV WKCV 49x -*M RSV RSFPV 49x -*M RSV RKFPV 49x -*M RSV FSFDV 49x -*M RSV FKFDV 49x -*M
WSV WSCV 49x -*M WSV RKCV 49x -*M WSV WKCV 49x -*M WSV RSFPV 49x -*M WSV RKFPV 49x -*M WSV FSFDV 49x -*M WSV FKFDV 49x -*M
RKV WSCV 49x -*M RKV RKCV 49x -*M RKV WKCV 49x -*M RKV RSFPV 49x -*M RKV RKFPV 49x -*M RKV FSFDV 49x -*M RKV FKFDV 49x -*M
WKV WSCV 49x -*M WKV RKCV 49x -*M WKV WKCV 49x -*M WKV RSFPV 49x -*M WKV RKFPV 49x -*M WKV FSFDV 49x -*M WKV FKFDV 49x -*M
RSCV WSCV 49x -*M RSCV RKCV 49x -*M RSCV WKCV 49x -*M RSCV RSFPV 49x -*M
× RSCV RKFPV 49x -*M RSCV FSFDV 49x -*M RSCV FKFDV 49x -*M
WSCV WSCV 49x -*M WSCV RKCV 49x -*M WSCV WKCV 49x -*M WSCV RSFPV 49x -*M WSCV RKFPV 49x -*M WSCV FSFDV 49x -*M WSCV FKFDV 49x -*M
RKCV RKCV 49x -*M RKCV WKCV 49x -*M RKCV RSFPV 49x -*M RKCV RKFPV 49x -*M RKCV FSFDV 49x -*M RKCV FKFDV 49x -*M
WKCV WKCV 49x -*M WKCV RSFPV 49x -*M WKCV RKFPV 49x -*M WKCV FSFDV 49x -*M WKCV FKFDV 49x -*M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 19
minifast® Cordset and Receptacle Connector Dimensions and Pinouts
Cordset
RSV-*
RSV-* RKV-*
RKV-*
WSV-*
WSV-* WKV-*
RSFPV-*
RSFPV-* RKFPV-*
RKFPV-* Mounting Installation
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
20 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Cordset and Receptacle Connector Dimensions and Pinouts
Cordset
RSCV-*
RSCV-* RKCV-*
RKCV-*
WSCV-*
WSCV-* WKCV-*
WKCV-*
FSFDV-*
FSFDV-* FKFDV-*
FKFDV-* Mounting Installation
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 21
InterlinkBT offers a full line
Marine Cable - Specifications of connectors approved by
DNV and ABS.
22 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Heavy Duty Cordsets
Cordsets
To meet the needs of the most
demanding applications, use the
heavy duty cordset. The long, heavy
coupling nut completely supports
the molded plug body to provide
superior strength.
2
Extensive field and lab testing of the
RKG style exceed SAE H1738-2 requirements - right angle
pull force tested to over 200 lbs!
RSGV-*
RSGV-* RKGV-*
RKGV-*
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 23
Short Circuit minifast® Junction Tee
Tee
SC models only
The FOUNDATION™ fieldbus junction tee is available with short circuit protection
Description and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged,
the new overmolded design provides unparalleled corrosive resistance.
P1
4-Pin Female
S0-S6
MOUNTING SCREW
Dimensions 1/4” (2)
NOT INCLUDED
Electrical
• Short Circuit Protection: 55mA (Isc)
• Voltage Open Circuit: 35VDC
• Current Consumption: 5mA
Diagnostic
Specifications • LED Indication:
Green LED - Bus Power; P1 and S0 only
Red LED - Short Circuit Indication
24 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector Size
Part Number
2
JTBS-49-M433 4 mini polyurethane stainless steel No
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 25
Fieldwireable Junction Tee
Tee
The FOUNDATION™ fieldbus fieldwireable junction tee is available with short circuit
Description protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically
rugged, the new overmolded design provides unparalleled corrosive resistance.
JTBS-49SC-I633
MOUNTING SCREW
Dimensions 1/4” (2)
NOT INCLUDED
Electrical
• Short Circuit Protection: 55mA (Isc)
• Voltage Open Circuit: 35VDC
• Current Consumption: 5mA
Diagnostic
Specifications • LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
26 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable Junction T
Wireable ee Assembly
Tee
Carrier
Connector Assembly
Seal
Nut
Termination kit
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
15-20mm
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 27
minifast® Passive Multiport Junctions (Bricks)
SC models only
The junction box is available with short circuit protection and is FM Approved for
Description Cl 1, Div 2 hazardous locations. The rugged, fully encapsulated die-cast aluminum
enclosure is available with stainless steel connectors.
Dimensions /
Part Number
Electrical
• Short Circuit Protection: 55mA(Isc)
• Voltage Open Circuit: 35VDC
• Current Consumption: 5mA
Applications Diagnostic
• LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70 degrees C
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-49-M413 to JBBS-49-M414
For fiberglass housing change part number to -Mx2x. Example: JBBS-49-M613 to JBBS-49-M623
28 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector Size
Part Number
JBBS-49-M813 8 mini aluminum stainless steel No
JBBS-49-M613 6 mini aluminum stainless steel No
JBBS-49-M413 4 mini aluminum stainless steel No
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 29
eurofast® Passive Multiport Junctions (Bricks)
SC models only
Description Rugged, fully encapsulated die-cast aluminum brick with eurofast® connectors.
Dimensions /
Part Number
Electrical
• Short Circuit Protection: 55mA(Isc)
• Voltage Open Circuit: 35VDC
Applications • Current Consumption: 5mA
Diagnostic
• LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70 degrees C
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-49-E413 to JBBS-49-E414
For fiberglass housing change part number to -Ex2x. Example: JBBS-49-E613 to JBBS-49-E623
30 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector Size
Part Number
JBBS-49-E813 8 euro aluminum stainless steel No
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 31
Device Gland Receptacles - 3 wire
Selection Guide eurofast® minifast®
minifast® eurofast®
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. N/C
4. Green/Yellow (Ground)
32 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Device Gland Receptacles - 2 wire
Selection Guide eurofast® minifast®
minifast® eurofast®
1. Blue (-Voltage)
2. Brown (+Voltage)
3. N/C
4. N/C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 33
Terminating Resistors
RSV 49-TR
RSEV 49-TR
34 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Conduit Adapter
minifast® eurofast® Schematic
trunk
2-port
BCA 49-M223 BCA 49-E223
drop
drop
trunk
1-port
BCA 49-M123 BCA 49-E123
drop
Change part number from BCA 49-M223 to BCA 49/P- M223
to fit on PVC coated conduit adapter.
Dimensions
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
Form 8 C28
C Mark 9 C29
LB Form 8 LB28
Conduit Bodies Mark 9 LB29
LL Form 8 LL28
Mark 9 LL29
LR Form 8 LR28
Mark 9 LR29
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 35
FOUNDATION™ fieldbus T
OUNDATION ees
Tees
RSV 2RKV 49
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
RSCV 2RKCV 49
eurofast ® tee
• stainless steel coupling nuts
36 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable T
Wireable ee
Tee
2
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” conve-
nience. This allows an extremely rapid changeover to a connectorized network, often in less
Description than 15 minutes. The Field Wireable IP67 Tee SPTTM13-A49 features standardized minifast®
connectors for the drop connection and field wireable terminals on the trunk connections. This
provides the best of both worlds, reliable connections on the short lengths and ease of
installation planning on the long trunk runs.
SPTT1-A49 SPTTM13-A49
Dimensions
W ireT
ire able
Table
Pin Designation Color
Specifications
1 V- Blue
2 V+ Brown
3 Shield Bare
4 Ground Green/Yellow
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 37
Gender Changers and Elbow Connectors
RKV RKV 49
WSV RKV 49
minifast® Elbow
• right angle male to female connector
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
* = Consult factory for availability.
38 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Surge Suppressor
This surge suppressor protects the data communication lines (V+ and V-) rather than just
the shield. The unique multi-stage design provides superior surge protection. The surge 2
suppressor absorbs the front end of the transient, responding in less than a nanosecond,
then diverts the surge energy to ground. Once the surge has been dissipated the
Description suppressor automatically resets and waits for the next surge.
The minifast ® connectors provide IEC IP67 protection in the rugged polyurethane overmolded
body. The surge suppressor is available with stainless steel coupling nuts and a ground stud.
RSV RKV 49 SS
Dimensions
Electrical
• Maximum Operating Voltage: 27 Volts
• Maximum Operating Current: 200mA
• Clamping Action Turn-On: 28.5 Volts
• Maximum Clamping at 2 kA: (8 X 20 µSec): 44 Volts
• Maximum Surge Voltage: 20 kV
Specifications • Maximum Surge Current: 2.5kA
• Current Leakage/Line At Operating Voltage: 5µA
• Capacitance/Line At Operating Voltage: 500pF
• Response Time: Less than 1 nanosecond
Mechanical
• Ground Stud: 10-32 Stainless Steel
• Operating Temperature: -40°C to +85°C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 39
Power Supply Conditioner
The Power Supply Conditioner meets the needs of redundant power supplies for
FOUNDATION™ fieldbus. This product has primary and secondary power inputs to supply
two Fieldbus H1 segments. Standard 24VDC power feeds into supplies A and B. It also
takes care of filtering the fieldbus signal from the power source. LED’s indicate which
Description Power Supply is primary and secondary. Diagnostics provide the status of each power
supply, indicating either READY or ACTIVE. The status is also provided through relay
outputs for further monitoring. Internal switches turn on/off terminators per segment.
BRPC-49-M213
4-Pin Euro = Monitor
Electrical
• Supply Voltage (Supply A & B): 12 - 32 VDC
• Supply Surge Protection (Supply A & B): >36 VDC
• Supply Redundancy (Supply A & B):
Supply “A” is Primary. If Supply “A” Voltage drops below 11 V, Supply “B”
becomes Active Supply “A” becomes Active once Voltage >11V
Specifications • Output Voltage (Segment 1 & 2): Input Voltage - 3 Volts
• Output Current (Segment 1 & 2): <1A
• Short Circuit Protection (Segment 1 & 2): >1A to Infinite
Diagnostic
• Power LED Indications: Green - Active / Red - No Power
• Segment LED Indications: Green - Active
• Supply Monitor Contacts (Supply A & B):
Solid State, AC/DC <400 V, <70 mA when supply Voltage >11V, Contact Is Closed
40 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Lokfast™ Guard
minifast® eurofast®
Standard
SHLD, MINI SHLD, EURO
Wireable
Field
SHLD, MINI FW SHLD, EURO FW
The JTBS-49SC series short circuit brick is classified as nonincendive equipment. This means
Description that it is considered nonarcing under normal operating conditions. In a fieldbus system the
trunk does not need to be serviced under normal operating conditions. The trunk connections
(P1 and S0) are to be locked with a Lokfast™ Guard to mechanically prevent separation.
Assembly/
Disassembly
Mechanical
• Dimensions: 43mm X D/A X 39mm
• Material: Nylon 6
• Environmental: Sun Resistant, UV Stable
Specifications
• Operating Temperature: -30ºC to 100ºC
• Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 41
Bulkhead Feed-Thru Receptacles
panel mount
For nickel-plated brass coupling nuts change part number to: RSFV RKFV 49/22 to RSF RKF 49/22
or
FKV FSV 49/M12 to FKM FS 49/M12
42 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Panel Mount Receptacles - minifast®, eurofast®
Selection Guide Female Male
Leads
eurofast® FKV 49 - *M FSV 49 - *M
Cable
eurofast® FKV 490 - *M FSV 490 - *M
RKFV 49 RSFV 49
FKV 49 FSV 49
Female eurofast®
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 43
Field W ireable Connectors - minifast®
Wireable
Selection Guide Aluminumx Stainless Steelx
B 4149-0/9 BS 4149-0/9
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
44 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable Connectors - eurofast ®
Wireable
Selection Guide Straight Right Angle
2
B8141-0/PG9 B8241-0/PG9
BS8141-0/PG9 BS8241-0/PG9
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 45
Closure Caps
Dimensions Description
RKMV BC
RSMV BC
RSFK-BC (10/BAG)
VZ-3 (8/BAG)
46 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-PA Cables and Accessories
-PA
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 47
PROFIBUS®-PA
-PA
PROFIBUS®-PA (Process Automation) uses synchronous transfer mode technology, as defined in IEC 61158-2,
to communicate between field devices and the RS 485 backbone of PROFIBUS®-DP. A segment coupler, or
gateway is installed to bridge PROFIBUS®-DP with PROFIBUS®-PA. Otherwise, the protocols are identical,
allowing transparent communication between general purpose automation systems and decentralized field
devices.
PROFIBUS®-PA is a master-slave bus. Transmitters used in the process industry are typically slave devices or
passive stations which only communicate at the request of the master.
48 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Star Topology Method
Topology
A star topology has a central connection point to all terminations. This layout works well when there are many
devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker
tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the
fieldbus segment. The best design would be to connect them all to a junction brick and then run a Home Run cable
from the junction brick back to the control room. See Figur e 4 for a pictorial example.
Figure
The Home Run cable is considered the main trunk line of communication. Each device that is connected to the
junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line.
Transmitters
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 49
Fieldbus Cable Specifications
The specifications for PROFIBUS®-PA physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2
Physical Layer Standards. There are essentially four types of cable designations for fieldbus. Type A cable is the
most preferred for new installations because it allows for the most versatile lengths. The other types of cable are
for installations where cable already exists from 4-20 mA systems. See T able 1
Table 1.
InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a
centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.02-
1992, the fieldbus standard for use in industrial control systems.
The maximum spur length is determined by the number of devices in the segment.
25-32 0 m (0 ft)
50 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-PA - Cable Specifications
-PA
Cable Specifications
Type A Cable
- Designed for harsh environments
- Temperature range of -40 to 105°C (-40 to +221F)
11
- Governed by: ISA SP50.02 specification
- Sunlight resistant per test
- PLTC and ITC rated (CSA FT4)
- Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20%
- Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km
- Maximum capacitive unbalance to shield = 2 nF/km
- Maximum DC resistance (per conductor) = 24 Ω/km
- Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km 33
- Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG)
- Minimum shield coverage shall be 90%
483 NEC ITC PLTC 2/18 AWG 6.5 Ohms PVC Orange Foil/Braid
None RB50785-*M 1
105°C 300V CEC [CMG] Blue/Brn PE 7.9mm (.310 in.) 20 AWG
483B NEC ITC PLTC 2/18 AWG 6.5 Ohms PVC Blue Foil/Braid
None RB50786-*M 1
105°C 300V CEC [CMG] Blue/Brn PE 7.9mm (.310 in.) 20 AWG
482A NEC ITC PLTC/CM 2/18 AWG 6.5 Ohms 18 AWG Armor/PVC Orange Foil
RB50929-*M 11
105°C 300V CEC [CMG HLBCD] Blue/Brn PE Green/Yellow 12.7mm (0.5 in.) 18 AWG
482BA NEC ITC PLTC 2/18 AWG 6.5 Ohms 18 AWG Armor/PVC Blue Foil
RB50952-*M 11
105°C 300V CEC [CMG] Blue/Brn PE Green/Yellow 12.7mm (0.5 in.) 18 AWG
483BK NEC ITC PLTC 2/18 AWG 6.5 Ohms PVC Black Foil/Braid
None RB50860-*M 1
105°C 300V CEC [CMG] Blue/Brn PE 7.9mm (.310 in.) 20 AWG
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 51
PROFIBUS®-PA - C ables and C or
-PA dsets
ordsets
minifast® † eurofast®
Try Cordset Builder Online!
Pin (Male) Socket (Female) Pin (Male)
RSV 48x - *M WSV 48x -*M RKV 48x -*M WKV 48x -*M RSCV 48x -*M
Bare
RSV RSV 48x -*M RSV WSV 48x -*M RSV RKV 48x -*M RSV WKV 48x -*M RSV RSCV 48x -*M
Pin (Male)
RSV
WSV WSV 48x -*M WSV RKV 48x -*M WSV WKV 48x -*M WSV RSCV 48x -*M
minifast®†
WSV
Socket (Female)
RKV RKV 48x -*M RKV WKV 48x -*M RKV RSCV 48x -*M
RKV
RSCV
eurofast®
WSCV
Socket (Female)
RKCV
WKCV
× Indicates cable type
* Indicates length in meters WSV RSCV 482-*M
Consult factory for availability of armorfast® with eurofast® connectors.
† armorfast ® cable only
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths
Example
1 METER
52 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-PA - C ables and Cor
-PA dsets
ordsets
Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female)
WSCV 48x -*M RKCV 48x -*M WKCV 48x -*M RSFPV 48x -*M RKFPV 48x -*M FSFDV 48x -*M FKFDV 48x -*M
RSV WSCV 48x -*M RSV RKCV 48x -*M RSV WKCV 48x -*M RSV RSFPV 48x -*M RSV RKFPV 48x -*M RSV FSFDV 48x -*M RSV FKFDV 48x -*M
WSV WSCV 48x -*M WSV RKCV 48x -*M WSV WKCV 48x -*M WSV RSFPV 48x -*M WSV RKFPV 48x -*M WSV FSFDV 48x -*M WSV FKFDV 48x -*M
RKV WSCV 48x -*M RKV RKCV 48x -*M RKV WKCV 48x -*M RKV RSFPV 48x -*M RKV RKFPV 48x -*M RKV FSFDV 48x -*M RKV FKFDV 48x -*M
3
WKV WSCV 48x -*M WKV RKCV 48x -*M WKV WKCV 48x -*M WKV RSFPV 48x -*M WKV RKFPV 48x -*M WKV FSFDV 48x -*M WKV FKFDV 48x -*M
RSCV WSCV 48x -*M RSCV RKCV 48x -*M RSCV WKCV 48x -*M RSCV RSFPV 48x -*M RSCV RKFPV 48x -*M RSCV FSFDV 48x -*M RSCV FKFDV 48x -*M
WSCV WSCV 48x -*M WSCV RKCV 48x -*M WSCV WKCV 48x -*M WSCV RSFPV 48x -*M WSCV RKFPV 48x -*M WSCV FSFDV 48x -*M WSCV FKFDV 48x -*M
RKCV RKCV 48x -*M RKCV WKCV 48x -*M RKCV RSFPV 48x -*M RKCV RKFPV 48x -*M RKCV FSFDV 48x -*M RKCV FKFDV 48x -*M
WKCV WKCV 48x -*M WKCV RSFPV 48x -*M WKCV RKFPV 48x -*M WKCV FSFDV 48x -*M WKCV FKFDV 48x -*M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 53
minifast® C ordset and Receptacle Connector D imensions and Pinouts
ordset
RSV-*
RSV-* RKV-*
RKV-*
WSV-*
WSV-* WKV-*
RSFPV-*
RSFPV-* RKFPV-*
RKFPV-* Mounting Installation
5.0
1.8
30.5
Male Female
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
54 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® C ordset and R eceptacle C onnector D imensions and Pinouts
ordset
RSCV-*
RSCV-*
RKCV-*
RKCV-*
WSCV-*
WSCV-*
WKCV-*
WKCV-*
FSFDV-*
FSFDV-* FKFDV-*
FKFDV-* Mounting Installation
Male Female
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 55
Short Circuit minifast® Junction Tee
Tee
SC models only
P1
4-Pin Female
Dimensions S0-S6
MOUNTING SCREW
1/4” (2)
NOT INCLUDED
Electrical
• Short Circuit Protection: 55mA(Isc)
Specifications • Voltage Open Circuit: 35VDC
• Current Consumption: 5mA
Diagnostic
• LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
56 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector size
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 57
minifast® Passive Multiport Junctions (Bricks)
SC models only
Dimensions /
Part Number
Electrical
• Short Circuit Protection: 55mA(Isc)
• Voltage Open Circuit: 35VDC
Applications
• Current Consumption: 5mA
Diagnostic
• LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-48-M413 to JBBS-48-M414
For fiberglass housing change part number to -Mx2x. Example: JBBS-48-M613 to JBBS-48-M623
58 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector size
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 59
eurofast® Passive Multiport Junctions (Bricks)
Dimensions /
Part Number
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-48-E413 to JBBS-48-E414
For fiberglass housing change part number to -Ex2x. Example: JBBS-48-E613 to JBBS-48-E623
60 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector size
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 61
Device Gland Receptacles - 2 wire
Selection Guide eurofast® minifast®
minifast® eurofast®
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. N/C
62 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Terminating Resistors
• male connector
RSV 48-TR
• male connector
RSEV 48-TR
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 63
Terminating Resistors - Ex
• male connector
RSV 48-TR-Ex
• male connector
RSEV 48-TR-Ex
Ex Approval
BVS 99.E.2044X
Entity Parameters:
For nickel-plated brass change: RSEV 48-TR-Ex to RSE 48-TR-Ex
U : ≥ 16.2V
RSV 48-TR-Ex to RSM 48-TR-Ex 0
I : ≥ 500mA
0
P : ≥ 1.8W
0
2-port
BCA 48-M223 BCA 48-E223
drop
drop
trunk
1-port
BCA 48-M123 BCA 48-E123
drop
The conduit adapter attaches to a standard conduit
body for transition to minifast® or eurofast® connectors.
Description
• Gasket and mounting hardware included (8-32 x 1/2”)
Pinout
3
Dimensions 1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
Form 8 C28
C Mark 9 C29
Form 8 LB28
LB Mark 9 LB29
Conduit Bodies
Form 8 LL28
LL
Mark 9 LL29
Form 8 LR28
LR
Mark 9 LR29
RSV 2RKV 48
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
RSCV 2RKCV 48
eurofast® tee
• stainless steel coupling nuts
66 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable T
Wireable ee
Tee
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.
This allows an extremely rapid changeover to a connectorized network, often in less than 15
®
Description minutes. The Field Wireable IP67 SPTTM13-A48 tee features standardized minifast connectors
for the drop connection and field wireable terminals on the trunk connections. This provides the
best of both worlds, reliable connections on the short lengths and ease of installation planning on
the long trunk runs.
SPTT1-A48 SPTTM13-A48
3
Dimensions
W ireT
ire able
Table
Pin Designation Color
Specifications
1 PA+ Brown
2 N/C --
3 PA- Blue
4 Shield Drain
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 67
Gender Changers and Elbow Connectors
RKV RKV 48
WSV RKV 48
minifast® Elbow
• right angle male to female connector
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
Consult factory for availability of stainless steel.
68 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Surge Suppressor
This surge suppressor protects the data communication lines (V+ and V-) rather than just the
shield. The unique multi-stage design provides superior surge protection. The surge suppressor
absorbs the front end of the transient, responding in less than a nanosecond, then diverts the
Description surge energy to ground. Once the surge has been dissipated the suppressor automatically
resets and waits for the next surge.
The minifast® connectors provide IP67 protection in the rugged polyurethane overmolded body.
The surge suppressor is available with stainless steel coupling nuts and ground stud.
RSV RKV 48 SS
3
Dimensions
Electrical
• Maximum Operating Voltage: 27 Volts
• Maximum Operating Current: 200mA
• Clamping Action Turn-On: 28.5 Volts
• Maximum Clamping at 2 kA: (8 X 20 µSec) : 44 Volts
• Maximum Surge Voltage: 20 kV
• Maximum Surge Current: 2.5kA
Specifications • Current Leakage/Line At Operating Voltage: 5µA
• Capacitance/Line At Operating Voltage: 500pF
• Response Time: Less than 1 nanosecond
Mechanical
• Ground Stud: 10-32 Stainless Steel
• Operating Voltage: 24 Volts
• Operating Temperature: -40°C to +85°C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 69
Lokfast™ Guard
minifast® eurofast®
Standard
SHLD, MINI SHLD, EURO
Wireable
Field
SHLD, MINI FW SHLD, EURO FW
Assembly/
Disassembly
Mechanical
• Dimensions: 43mm X D/A X 39mm
• Material: Nylon 6
Specifications • Environmental: Sun Resistant, UV Stable
• Operating Temperature: -30ºC to 100ºC
• Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
70 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bulkhead Feed-Thru Receptacles
panel mount
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 71
Panel Mount Receptacles - minifast®, eurofast®
Selection Guide Female Male
leads
eurofast® FKV 48 - *M FSV 48 - *M
RKFV 48 - *M RSFV 48 - *M
FKV 48 - *M FSV 48 - *M
Female eurofast®
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
72 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable Connectors - minifast®
Wireable
Selection Guide Aluminumx Stainless Steelx
B 4148-0/9 BS 4148-0/9
Male Female
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 73
Field W ireable Connectors - eurofast®
Wireable
Selection Guide Straight Right Angle
Field wireable connectors for bus lines and drops facilitate field replacement.
B8141-0/PG9 B8241-0/PG9
BS8141-0/PG9 BS8241-0/PG9
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
Rating: 3 A, 36 VDC Rating: 3 A, 36 VDC
74 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Closure Caps
Dimensions Description
RKMV BC
RSMV BC
RSFK-BC (10/BAG)
VZ-3 (8/BAG)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 75
HAR
HARTT ® Cables and Accessories
76 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HART® Overview
HART® (Highway Addressable Remote Transducer) is a protocol which supports two-way digital communication for
process measurement and control devices. Although it is not an international standard, it is considered an “open”
protocol, broadly accepted in the process industry. HART® devices can store process related information and
communicate digitally. It can also be used with traditional 4-20 mA devices. This is beneficial if there is a large
existing installed base of 4-20 mA transmitters.
The maximum HART® cable length is 1500 meters. However, the physical media is limited by a maximum system
attenuation of 3 dB. This is ensured if there is a resistance-capacitance combination having an RC time-constant
value of 65 µF (the circuit resistance R divided by the capacitance C). The system design must consider both
resistance of the device and the cable, likewise the capacitance of the device and the cable. In a typical system
the host load resistance is 250Ω. HART® recommends a maximum capacitance of 5000 pF on slave devices.
Devices with higher capacitance must list the capacitance number (CN). This number equals the actual device
capacitance divided by 5000 pF. For example, a device with a capacitance of 10,000 pF would have CN = 2.
Resistance is measured for both conductors in series. Capacitance is measured from one conductor to all others
and the screen. The values for InterlinkBT® cables are as follows:
0.30 H40
H120
H190
Device CTotal (µF)
0.20 HM40
0.10
0.00
0 500 1000 1500
Length (meters)
HART® simulation software to determine maximum lengths can be found at www.romilly.co.uk. The software
H-SIM can be downloaded free of charge.
78 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HAR
HARTT ® - Cable Specifications
A B
C D
4
Data Pair Device Ground Outer Jacket Shield
Approvals AWG DCR (/1000 ft) Material Color Type
Type Network Ref.
AWG Color Code
Color Code Insulation Nominal O.D. Drain Wire Standard
H40 NEC PLTC 2/22 AWG 16.5 Ohms 20 AWG PVC Grey Foil
RB50824-*M A
105°C 300V CEC [CMG] Blue/Brn PE Green/Yellow 7.2mm (.285 in.) 22 AWG
H40A NEC ITC PLTC 2/18 AWG 6.5 Ohms 18 AWG Armor/PVC Grey Foil
RB50939-*M B
105°C 300V CEC [CMG] Blue/Brn PE Green/Yellow 7.9mm (.310 in.) 18 AWG
H120 NEC ITC PLTC/CM 4 Pairs 16.5 Ohms 18 AWG PVC Grey Foil
RB50825-*M D
105°C 300V CEC [CMG HLBCD] 2/22 AWG PE Green/Yellow 12.7mm (0.5 in.) 18 AWG
H190 NEC ITC PLTC/CM 8 Pairs 16.5 Ohms 18 AWG PVC Grey Foil
RB50826-*M C
105°C 300V CEC [CMG HLBCD] 2/22 AWG PE Green/Yellow 12.7mm (0.5 in.) 18 AWG
HM40 NEC PLTC 2/18 AWG 6.5 Ohms PVC Grey Foil
None RB50938-*M A
105°C 300V CEC [CMG]] Blue/Brn PE 7.9mm (.310 in.) 20 AWG
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 79
HAR
HARTT ® - Cables and Cordsets
Cordsets
minifast® † eurofast®
RSV RSV Hx 4x - *M RSV WSV Hx 4x - *M RSV RKV Hx 4x - *M RSV WKV Hx 4x - *M RSV RSCV Hx 4x - *M
RSV
minifast® †
RSCV RSCV Hx 4x - *M
Pin (Male)
RSCV
eurofast®
WSCV
Socket (Female)
RKCV
WKCV
× Indicates cable type
Indicates length in meters WSV RSCV H40-1M
*
Consult factory for availability of armorfast® with eurofast® connectors.
† Armorfast® cable only
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths.
Example
1 METER
80 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HAR
HARTT ® - Cables and Cordsets
Cordsets
Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female)
RSV WSCV Hx 4x - *M RSV RKCV Hx 4x - *M RSV WKCV Hx 4x - *M RSV RSFPV Hx 4x - *M RSV RKFPV Hx 4x - *M RSV FSFDV Hx 4x - *M RSV FKFDV Hx 4x - *M
WSV WSCV Hx 4x - *M WSV RKCV Hx 4x - *M WSV WKCV Hx 4x - *M WSV RSFPV Hx 4x - *M WSV RKFPV Hx 4x - *M WSV FSFDV Hx 4x - *M WSV FKFDV Hx 4x - *M
RKV WSCV Hx 4x - *M RKV RKCV Hx 4x - *M RKV WKCV Hx 4x - *M RKV RSFPV Hx 4x - *M RKV RKFPV Hx 4x - *M RKV FSFDV Hx 4x - *M RKV FKFDV Hx 4x - *M
WKV WSCV Hx 4x - *M WKV RKCV Hx 4x - *M WKV WKCV Hx 4x - *M WKV RSFPV Hx 4x - *M WKV RKFPV Hx 4x - *M WKV FSFDV Hx 4x - *M WKV FKFDV Hx 4x - *M
RSCV WSCV Hx 4x - *M RSCV RKCV Hx 4x - *M RSCV WKCV Hx 4x - *M RSCV RSFPV Hx 4x - *M RSCV RKFPV Hx 4x - *M RSCV FSFDV Hx 4x - *M RSCV FKFDV Hx 4x - *M
WSCV WSCV Hx 4x - *M WSCV RKCV Hx 4x - *M WSCV WKCV Hx 4x - *M WSCV RSFPV Hx 4x - *M WSCV RKFPV Hx 4x - *M WSCV FSFDV Hx 4x - *M WSCV FKFDV Hx 4x - *M 4
RKCV RKCV Hx 4x - *M RKCV WKCV Hx 4x - *M RKCV RSFPV Hx 4x - *M RKCV RKFPV Hx 4x - *M RKCV FSFDV Hx 4x - *M RKCV FKFDV Hx 4x - *M
WKCV WKCV Hx 4x - *M WKCV RSFPV Hx 4x - *M WKCV RKFPV Hx 4x - *M WKCV FSFDV Hx 4x - *M WKCV FKFDV Hx 4x - *M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 81
minifast® Cordset and Receptacle Connector Dimensions and Pinouts
Cordset
RSV-*
RSV-* RKV-*
RKV-*
WSV-*
WSV-* WKV-*
RSFPV-*
RSFPV-* RKFPV-*
RKFPV-* Mounting Installation
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
82 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Cordset and Receptacle Connector Dimensions and Pinouts
Cordset
RSCV-*
RSCV-* RKCV-*
RKCV-*
WSCV-*
WSCV-* WKCV-*
WKCV-*
FSFDV-*
FSFDV-* FKFDV-*
FKFDV-* Mounting Installation
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 83
HAR
HARTT ® - Cables and Cordsets
Cordsets
multifast®
CSM H1xx -*M CSWM H1xx -*M CKM H1xx -*M CKWM H1xx -*M
Bare
CSM CSM H1xx -*M CSM CSWM H1xx -*M CSM CKM H1xx -*M CSM CKWM H1xx -*M
Pin (Male)
CSM
CSWM CSWM H1xx -*M CSWM CKM H1xx -*M CSWM CKWM H1xx -*M
multifast®
CSWM
Socket (Female)
CKM
CKWM
Coupling nuts shown are nickel-plated brass. Consult factory for availability of stainless steel.
Example
1 METER
84 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
multifast® Receptacle Connector Dimensions and Pinouts
CSM...CKM...
CSM...CKM... CSWM...CKWM...
CSWM...CKWM...
NAMUR HART®
HART Color NAMUR HAR
HARTT® Color
V+ V- V+ V-
J1 V- V+ J1 V- V+
Drain Drain Drain Drain
V+ V- V+ V-
J2 V- V+ J2 V- V+
Drain Drain Drain Drain
V+ V- V+ V-
J3 V- V+ J3 V- V+
Drain Drain Drain Drain
V+ V- V+ V-
J4 V- V+ J4 V- V+
Drain Drain Drain Drain
Ground
Ground Ground
Ground V+ V-
Drain Drain J5 V- V+
Drain Drain
V+ V-
J6 V-
Drain
V+
V+
Drain
V-
4
J7 V- V+
Drain Drain
V+ V-
J8 V- V+
Drain Drain
Ground
Ground Ground
Ground
Drain Drain
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 85
HART ® Junction T
HART ee
Tee
The HART® junction tee provides a rugged connection to all of your fieldbus devices.
Mechanically rugged, the new overmolded design provides unparalled corrosive
Description
resistance. It is also available with either multifast® connectors for point-to-point
wiring, or minifast® connectors for multidrop installations.
JTBS-40H-CS12
P1 12-Pin Male J0-J4
JTBS-60HM-RS4
P1 4-Pin Male J0-J6
* change RS to RSV for stainless steel connectors
change CS to CSV for stainless steel connectors
(consult factory for availability)
NAMUR Sensor
86 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Quick Selection Guide
Connector Material
Overmold Material
Number of Ports
Connector Size
(P1)
(J0-JX)
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 87
eurofast® Multibox Aluminum Junctions (Bricks)
Dimensions
HARTT
HART ransmitter
Transmitter
NAMUR Sensor
88 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Multibox Nylon Junctions (Bricks)
Dimensions
NAMUR Sensor
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 89
Device Gland Receptacles - 3 wire
Selection Guide eurofast® minifast®
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. N/C
4. Green/Yellow (Ground)
90 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Conduit Adapter
minifast® eurofast® Schematic
trunk
2-port
BCA 4HM-M223 BCA 4HM-E223
drop
drop
2-port
source
BCA 4H-M223 BCA 4H-E223
drop
drop
trunk
1-port
BCA 4HM-M123 BCA 4HM-E123
drop
The conduit adapter attaches to a standard conduit
Description body for transition to minifast® or eurofast® connectors.
Form 8 LB28
LB Mark 9 LB29
Conduit Bodies
Form 8 LL28
LL
Mark 9 LL29
Form 8 LR28
LR
Mark 9 LR29
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
RSCV 2RKCV H4
eurofast® tee
• stainless steel coupling nuts
92 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable multidrop® T
Wireable ee
Tee
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.
This allows an extremely rapid changeover to a connectorized network, often in less than 15
Description minutes. The Field Wireable IP67 Tee SPTTM13-AHM4 features standardized minifast® connectors
for the drop connection and field wireable terminals on the trunk connections. This provides the
best of both worlds, reliable connections on the short lengths and ease of installation planning on
the long trunk runs.
SPTT1-AHM4 SPTTM13-AHM4
Dimensions
W ireT
ire able
Table
Pin Designation Color
Specifications
1 V- Blue
2 V+ Brown
3 Shield Bare
4 Ground Green/Yellow
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 93
Gender Changers and Elbow Connectors
RSV RSV H4
RKV RKV H4
WSV RKV H4
minifast® Elbow
• right angle male to female connector
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
94 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bulkhead Feed-Thru Receptacles
panel mount
For nickel-plated brass coupling nuts change part number: RSFV RKFV H4/22 to RSF RKF H4/22
or
FKV FSV H4/M12 to FKM FS H4/M12
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 95
Panel Mount Receptacles - minifast®, eurofast®
Selection Guide Female Male
Leads
eurofast® FKV H4 - *M FSV H4 - *M
Cable
eurofast® FKV H40 - *M FSV H40 - *M
RKFV H4 - *M RSFV H4 - *M
FKV H4 - *M FSV H4 - *M
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
96 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Panel Mount Receptacles - multifast®
Selection Guide Female Male
Leads
19-pin CKF H19 CSF H19
Cable
19-pin CKF H190 CSF H190
CKF.. or CSF
CKF.. ..
CSF..
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 97
Field W ireable Connectors - minifast®
Wireable
Selection Guide Aluminum Stainless Steel
B 4149-0/9 BS 4149-0/9
Male Female
1. Blue (-Voltage)
2. Brown (+ Voltage)
3. Bare (Shield Drain Wire)
4. Green/Yellow (Ground)
98 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W ireable Connectors - eurofast®
Wireable
Selection Guide Straight Right Angle
B8141-0/PG9 B8241-0/PG9
BS8141-0/PG9 BS8241-0/PG9
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 99
Field W ireable Connectors - multifast®
Wireable
Selection Guide 12-pin* 19-pin**
CK.. CS..
Female contact holder, female threads Male contact holder, female threads
Male Female
100 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Closure Cap
Dimensions Description
RKMV BC
RSMV BC
RSFK-BC (10/BAG)
VZ-3 (8/BAG)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 101
Index
Symbols F
4MB12-40H-CS12 ............................................89 FKV 48 - *M ...........................................................72
8MB12-40H-CS19 ............................................89 FKV 483 - *M .........................................................72
FKV 49 ...................................................................43
B FKV 490 - *M .........................................................43
B 4148-0/9 .......................................................73 FKV FSV 48/M12 ....................................................71
B 4149-09...................................................98, 44 FKV FSV 49/M12 ....................................................42
B8141-0/PG9 .....................................99, 74, 45 FKV FSV H4/M12 ...................................................95
B8241-0/PG9 ......................................99, 74, 45 FKV H4 - *M ...........................................................96
BCA 48-E123 ...................................................65 FKV H40 - *M .........................................................96
BCA 48-E223 ...................................................65 FOUNDATION fieldbus - Cable Specifications ........17
BCA 48-M123 ..................................................65 FOUNDATION fieldbus - Cable and Cordsets ...18-19
BCA 48-M223 ..................................................65 FSV 48 - *M ............................................................72
BCA 49-E123 ...................................................35 FSV 483 - *M ..........................................................72
BCA 49-E223 ...................................................35 FSV 48T-*M / 14.5 ..................................................62
BCA 49-M123 ..................................................35 FSV 48T-*M / 14.75 ................................................62
BCA 49-M223 ..................................................35 FSV 48T-*M / M20 ..................................................62
BCA 4HM-E123 ................................................91 FSV 49 ...................................................................43
BCA 4HM-E223 ................................................91 FSV 49-*M / 14.5 ....................................................32
BCA 4HM-M123 ...............................................91 FSV 49-*M / 14.75 ..................................................32
BCA 4HM-M223 ...............................................91 FSV 49-*M / M20 ....................................................32
BRPC-49-M213 ................................................40 FSV 490 - *M ..........................................................43
BS 4148-0/9 .....................................................73 FSV 49T-*M / 14.5 ..................................................33
BS 4149-0/9 ..............................................98, 44 FSV 49T-*M / 14.75 ................................................33
BS8141-0/PG9 ...................................99, 74, 45 FSV 49T-*M / M20 ..................................................33
BS8241-0/PG9 ...................................99, 74, 45 FSV H4 - *M ...........................................................96
BSV 4148-0/9 ...................................................73 FSV H4-*M / 14.5 ...................................................90
BSV 4149-0/9 ............................................98, 44 FSV H4-*M / 14.75 .................................................90
BV 4148-0/9 .....................................................73 FSV H4-*M / M20 ...................................................90
BV 4149-0/9 ..............................................98, 44 FSV H40 - *M .........................................................96
C H
120 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Index
JBBS-49-M613 .................................................28 RSFV 49T-*M / M20 ........................................33
JBBS-49-M813 .................................................28 RSFV H4 - *M .................................................96
JTBS-40H-CS12 ...............................................86 RSFV H4-*M / 14.5 .........................................90
JTBS-48SC-M633 .............................................56 RSFV H4-*M / 14.75 .......................................90
JTBS-49-I633 ....................................................26 RSFV H4-*M / M20 .........................................90
JTBS-49SC-M633 .............................................24 RSFV H40 - *M ...............................................96
JTBS-60HM-RS4 ..............................................86 RSFV RKF 48/22 .............................................71
JTBS-70H-CS19 ...............................................86 RSFV RKF 49/22 .............................................42
JTBS Part Number Key .....................................11 RSFV RKF H4/22 ............................................95
RSGV-* ...........................................................23
M RSM 48-FK 4.5 ...............................................68
Marine Cable .....................................................22 RSM 49-FK 4.5 ...............................................38
minifast® Part Number Keys ..............................10 RSM H4-FK 4.5 ................................................94
RSMV BC .........................................101, 75, 46
P RSV 2RKV 48 ..................................................66
RSV 2RKV 49 ..................................................36
PROFIBUS-PA - Cable Specifications ................51 RSV 2RKV HM4 ..............................................92
PROFIBUS-PA - Cables and Cordsets .........52-53 RSV 48-TR ......................................................63
RSV 48-TR-Ex .................................................64
R
RSV 49-TR ......................................................34
RKFV 48 - *M ....................................................72 RSV FKV RKV 48 ............................................66
RKFV 483 - *M ..................................................72 RSV FKV RKV 49 ............................................36
RKFV 49 ............................................................43 RSV FKV RKV HM4 .........................................92
RKFV 490 - *M ..................................................43 RSV RKV 48 SS ..............................................69
RKFV H4 - *M ....................................................96 RSV RKV 49 SS ..............................................39
RKFV H40 - *M ..................................................96 RSV RSV 48 ....................................................68
RKGV-* ..............................................................23 RSV RSV 49 ....................................................38
RKMV BC ..........................................101, 75, 46 RSV RSV H4 ...................................................94
RKV RKV 48 ......................................................68
RKV RKV 49 ......................................................38 S
RKV RKV H4 .....................................................94 SHLD, EURO ............................................70, 41
RSCV 2RKCV 48 ...............................................66 SHLD, EURO FW ......................................70, 41
RSCV 2RKCV 49 ...............................................36 SHLD, MINI ...............................................70, 41
RSCV 2RKCV H4 ..............................................92 SHLD, MINI FW ........................................70, 41
RSEV 48-TR ......................................................63 SPTT1-A48 ......................................................67
RSEV 48-TR-Ex .................................................64 SPTT1-A49 ......................................................37
RSEV 49-TR ......................................................34 SPTT1-AHM4 ..................................................93
RSFK-BC (10/BAG) ...........................101, 75, 46 SPTTM13-A48 .................................................67
RSFV 48 - *M ....................................................72 SPTTM13-A49 .................................................37
RSFV 483 - *M ..................................................72 SPTTM13-AHM4 .............................................93
RSFV 48T-*M / 14.5 ..........................................62
RSFV 48T-*M / 14.75 ........................................62 V
RSFV 48T-*M / M20 ..........................................62
RSFV 49 ............................................................43 VBM-40H-CS12 ..............................................88
RSFV 49-*M / 14.5 ............................................32 VBM-80H-CS19 ..............................................88
RSFV 49-*M / 14.75 ..........................................32 VZ-3 (8/BAG) ...................................101, 75, 46
RSFV 49-*M / M20 ............................................32 W
RSFV 490 - *M ..................................................43
RSFV 49T-*M / 14.5 ..........................................33 WSV RKV 48 ...................................................68 6
RSFV 49T-*M / 14.75 ........................................33 WSV RKV 49 ...................................................38
WSV RKV H4 ..................................................94
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 121
V isit us at www.interlinkbt.com
www.interlinkbt.com
*
Link to support.interlinkbt.com
What’s New:
What’s Check the latest articles, literature updates and product releases.
Products:
Products: Complete listing of network cables and cordsets, interconnection products, accessories,
I/O stations and modules, I/O systems and more.
Sear ch:
Search: Use keywords and phrases to locate specific information.
Tech Support: See page 123.
Calendar: Check out the events in your area.
Literature:
Literature: Contains a complete listing of catalogs, brochures, tutorials, CAD drawings and electronic
news releases from InterlinkBT®. Download pdf files or register for mail copy.
Contacts: Sales - Find reps and distributors in your area.
Partners - Lists affiliates and trade associations.
Integrators - Contains business summaries and web site links.
Us - Submit requests and comments directly to InterlinkBT®.
About Us: Contains company information and opportunities.
Login: The login page provides access to the secure area for the InterlinkBT® sales channel.
122 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
V isit us at support.interlinkbt.com
* Click Tech Support from interlinkbt.com or visit support.interlinkbt.com
App. Notes: Application Notes contain documents for approvals and testing, mapping and configuration
and application guidelines.
CAD Library: Contains Product CAD Files - search by network and/or part number.
Config. Files: EDS and GSD file search.
Documents: Download catalogs, guides, manuals and wiring diagrams.
Softwar e:
Software: Lists software that is available for download.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 123
Warranty
InterlinkBT, LLC (hereinafter “InterlinkBT”) warrants the Products covered by this WARRANTY AGREEMENT to be free from defects in
material and workmanship under normal and proper usage for 18 months from the date of shipment from InterlinkBT.
THE WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE – BOTH EXPRESSED AND IMPLIED.
THERE ARE NO WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR PRODUCTS COV-
ERED BY THESE TERMS AND CONDITIONS.
InterlinkBT warrants that the goods sold are as described, but no promise, description, affirmation of fact, sample model or representation,
oral or written shall be part of an order, unless set forth in these terms and conditions, or are in writing and signed by an authorized
representative of InterlinkBT. This warranty does not apply to any Product which has been subject to misuse, negligence, or accident – or
to any Product which has been modified or repaired, improperly installed, altered, or disassembled – except according to InterlinkBT’s
written instructions.
1. This WARRANTY is limited to the electronic and mechanical performance only, as expressly detailed in the Product specifications and
NOT to cosmetic performance.
2. This WARRANTY shall not apply to any cables attached to, or integrated with the Product. However, the 18 month warranty shall
apply to cables sold separately by InterlinkBT.
3. This WARRANTY shall not apply to any products which are stored, or utilized, in harsh environmental or electrical conditions outside
written specifications.
4. The WARRANTY is applicable only to Products shipped from InterlinkBT subsequent to May 1, 1998.
Purchaser’s Remedies
If an InterlinkBT Distributor desires to make a WARRANTY Claim, the Distributor shall, if requested by InterlinkBT, ship the Product to
InterlinkBT’s facility in Minneapolis, Minnesota, postage or freight prepaid. If the User desires to make a WARRANTY Claim, they shall
notify the authorized InterlinkBT Distributor from whom it was purchased or, if such Distributor is unknown, shall notify InterlinkBT. InterlinkBT
shall, at its option, take either of the following two courses of action for any products which InterlinkBT determines are defective in
materials or workmanship.
1. Repair or replace the Product and ship the Product to the Original Purchaser or to the authorized InterlinkBT Distributor, postage or
freight prepaid; or
2. Repay to the Original Purchaser that price paid by the Original Purchaser.
PURCHASER’S REMEDIES SHALL BE LIMITED EXCLUSIVELY TO THE RIGHT OF REPLACEMENT, REPAIR OR REPAYMENT AS PRO-
VIDED AND DOES NOT INCLUDE ANY LABOR COST OR REPLACEMENT AT ORIGINAL PURCHASER’S SITE. INTERLINKBT SHALL
NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF ANY WARRANTY, EXPRESSED OR
IMPLIED, APPLICABLE TO THE PRODUCT, INCLUDING WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM PROPERTY DAM-
AGE, PERSONAL INJURY OR BUSINESS INTERRUPTION.
Risk of Loss
Delivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time to
Purchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaser
upon notification by InterlinkBT that the order is complete and ready for shipment.
Governing Law
The sale and purchase of Products covered hereby and all terms and conditions hereof shall be governed by the law of the State of
Minnesota.
Product Availability
InterlinkBT makes every effort to stock most of these part numbers in reasonable quantities. InterlinkBT also makes no guarantee of
availability of any product represented. Some part numbers are available on a special order basis only and may require longer lead times.
Please consult with InterlinkBT when you need a committed delivery date.
Field Service
124 Please contact
InterlinkBT®
InterlinkBT
3000 Campus for details.
Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880