Section Ii Operation: iPASOLINK 100/200
Section Ii Operation: iPASOLINK 100/200
iPASOLINK 100/200
SECTION II OPERATION
CONTENTS
DOCUMENT WARRANTY.....................................................................................................- 5 -
1. Getting Started .............................................................................................................1-1
1.1 Conventions Used in This Manual .......................................................................................... 1-1
1.2 LCT Communication Interface ................................................................................................ 1-1
1.2.1 Communications.............................................................................................................. 1-1
1.2.2 Local Port Interface ......................................................................................................... 1-2
1.3 Equipment Configuration of iPASOLINK................................................................................. 1-2
2. Installation of LCT .......................................................................................................2-1
2.1 Hardware Requirements......................................................................................................... 2-1
2.2 Software Requirements .......................................................................................................... 2-2
2.3 OS Environment for Windows................................................................................................. 2-2
2.3.1 Internet Explorer.............................................................................................................. 2-2
2.3.2 Confirming and Setting TCP/IP ....................................................................................... 2-3
2.4 Recommended browser settings ............................................................................................ 2-4
2.4.1 Internet Explorer 8........................................................................................................... 2-4
2.4.2 Firefox 3.6.x..................................................................................................................... 2-7
3. System Configuration .................................................................................................3-1
3.1 General................................................................................................................................... 3-1
3.2 System Configuration ............................................................................................................. 3-2
3.3 System Overview.................................................................................................................... 3-4
3.3.1 IDU Block Diagram .......................................................................................................... 3-5
3.3.2 ODU Block Diagram ........................................................................................................ 3-5
3.4 Interfaces ................................................................................................................................ 3-6
3.4.1 Baseband Interface ......................................................................................................... 3-6
3.4.1.1 E1 Interface............................................................................................................ 3-6
3.4.1.2 LAN (FE) Interface ................................................................................................. 3-6
3.4.1.3 LAN (GbE) interface............................................................................................... 3-7
3.4.2 LCT /NMS Interface......................................................................................................... 3-7
3.4.2.1 LCT Interface ......................................................................................................... 3-7
3.4.2.2 NMS Interface ........................................................................................................ 3-7
Operation NWD-107461-04E
September, 2011
-2-
NWD-107461-04E Operation
-3-
Operation NWD-107461-04E
-4-
6. Abbreviations ...............................................................................................................6-1
NWD-107461-04E Operation
DOCUMENT WARRANTY -5-
DOCUMENT WARRANTY
Operation NWD-107461-04E
- 6 -/END DOCUMENT WARRANTY
NWD-107461-04E Operation
Getting Started 1-1
1. GETTING STARTED
1.2.1 Communications
The local craft terminal is a useful tool to the installation and maintenance.
iPASOLINK supply users GUI environment through WEB browser. Moreover, this
tool supports remote connection.
Operation NWD-107461-04E
1-2/END Getting Started
Use LAN Cable connected to the LCT Port at the front of equipment.
Non-protected (1+0), Protected (1+1) with hot standby / space diversity / twin path
with hitless switch, Back-to-back configuration ((1+0) x 2)
NWD-107461-04E Operation
Installation of LCT 2-1
2. INSTALLATION OF LCT
* Windows Vista
Item Required Recommend
CPU Intel Core2 Duo 1.6 GHz
RAM 1 GB
HDD 40 GB
Display Color LCD (1024x768)
LAN Port 10/100BASE-T(X)
USB Port
* Windows 7
Item Required Recommend
CPU Intel Core2 Duo 1.6 GHz
RAM 1 GB
HDD 40 GB
Display Color LCD (1024x768)
LAN Port 10/100BASE-T(X)
USB Port
Operation NWD-107461-04E
2-2 Installation of LCT
NWD-107461-04E Operation
Installation of LCT 2-3
2. Select Start -> Settings -> Control Panel from the Start menu of the
Windows.
Operation NWD-107461-04E
2-4 Installation of LCT
1. Tools -> Internet Options -> General -> Tabs Settings from the Tool Bar menu
of the Internet Explorer 8.
NWD-107461-04E Operation
Installation of LCT 2-5
1. Tools -> Internet Options -> Security -> Security Level for this zone “Custom
level…” from the Tool Bar menu of the Internet Explorer 8.
Operation NWD-107461-04E
2-6 Installation of LCT
NWD-107461-04E Operation
Installation of LCT 2-7
Operation NWD-107461-04E
2-8/END Installation of LCT
NWD-107461-04E Operation
System Configuration 3-1
3. SYSTEM CONFIGURATION
3.1 General
iPASOLINK 100/200 is a basic configuration for nodal application in the wireless
iPASOLINK family and providing up to 440 Mbps with flexible combination of
native TDM and/or native Ethernet transmission and advanced adaptive modulation
scheme operating in 6, 7, 8, 10, 11, 13, 15, 18, 23, 26, 28, 32 or 38 GHz bands.
The iPASOLINK consists of antenna, outdoor unit (ODU) and indoor unit (IDU) like
as PASOLINK series and accedes to very high performance and ultra high reliability
gained through NEC’s rigid TQC activities and vast experience in wired and wireless
communication fields.
Operation NWD-107461-04E
3-2 System Configuration
NWD-107461-04E Operation
System Configuration 3-3
z IDU x2_2way
z 2+0
Operation NWD-107461-04E
3-4 System Configuration
- Flexible configuration for ODU and antenna, direct mount / remote mount / 1+0
(non redundant) / 1+1 hot stand-by / 1+1 space diversity / 1+1 frequency diversity
(twin path), 2+0.
- Small and light weight ODU for easy handling and installation.
NWD-107461-04E Operation
System Configuration 3-5
Operation NWD-107461-04E
3-6 System Configuration
3.4 Interfaces
3.4.1.1 E1 Interface
- Connector: MDR68
- Port number and interface: 2 (default), Max.4 (2xFE interface can be changed
into 4 x 10/100/ 1000Base-T by software key)
NWD-107461-04E Operation
System Configuration 3-7
- Port number and interface: 2 (default), Max.4 (2xFE interface can be changed
into 4 x 10/100/ 1000Base-T (RJ-45) by software
key)
The local craft terminal is a useful tool to the installation and maintenance.
iPASOLINK supply users GUI environment through WEB browser. Moreover, this
tool supports remote connection.
This port is used to connect with the NMS server through the network.
- TNC female
Operation NWD-107461-04E
3-8 System Configuration
This port is used for alarm outside connection, and for digital service channels and
external clock signal.
USB memory is useful to store the equipment setting and configuration data. This
information storage is used for equipment replacement and recovery of setting and
configuration.
This card has E1 and STM-1 converter function and has STM-1 optical interface.
- Connector: LC
This card is the same function as STM-1 optical function and has STM-1 electrical
interface.
NWD-107461-04E Operation
System Configuration 3-9
Additional power line inlet can apply for operation of two independently power lines.
Operation NWD-107461-04E
3-10 System Configuration
3.5.1 General
NO Item IDU
Operation:-5 to +50 deg.C (ETSI EN300019-1-4 class 3.1E),
Humidity: 95% (at 50 deg.C, No condensing)
1 Environmental condition (Workable: -10 to +55 deg.C)
Transportation ETSI EN300019-1-2 class 2.3
Storage ETSI 300019-1-1 class 1.2
2 Power consumption 1+0 1+1
3 IDU without options 45W 45W
4 Option AUX 5W 5W
5 Option 16 E1 5W 5W
6 Option STM-1 5W 5W
7 External clock board 3W
8 Mechanical Dimensions 1+0/ 1+1
9 IDU Size 482(W)x44(H)x240(D) mm, 3kg Approx.
10 EMC Conforms to EN301 489-4
11 Safety Conforms to EN60950-1
4 Power Line Requirement -48 VDC (-40.5 to -57 VDC), Conforms to EN300 132-2
NWD-107461-04E Operation
System Configuration 3-11
NO Item IDU
Function outline
Native Ethernet and Native
5 MODEM has both native Ethernet and Native TDM signal processing circuit
TDM
QPSK/ 16QAM/ 32QAM/ 64QAM/ 128QAM/ 256QAM :
6 Adaptive modulation (AMR)
6 modulation schemes changeable
7 Radio protection method 1+1 HS/HS,HS/SD,FD(HS: Hot Stand by, SD: Space Diversity, FD: Frequency Diversity
8 E1 Ring protection E1 SNCP support
Switching Capacity 20 Gbps (Non Blocking)
MAC Learning Independent VLAN Learning(VLAN + MAC),
Table Up to 128K (configurable)
Port based, Tag based,
Up to 256 VLAN per equipment,
VLAN
MEF 9 Certified EPL, EVPL and ELAN services support with L2CP
Tunneling function
Jumbo Frame Support (Up to 9600 byte)
MEF/RFC4115 compliant policing
(CIR/EIR/CBS/EBS)
Ingress
QoS Class Classification: VLAN CoS/IPv4 DSCP/IPv6
9 ETH functions DSCP/MPLS EXP/ETH Port
4 Classes SP/D-WRR queues
QoS - per-class rate configurable shaping
- per-class configurable maximum burst length
Egress
- shaping for strict priority queue
Hierarchical shaping (Port and Class)
WRED congestion avoidance and Weighted Tail Drop
ETH OAM 802.1ag Service OAM (CC/LB/LT)
Protection STP/RSTP
SyncE Support
Other Link Loss Forwarding, Mirroring, Broadcast Storm Control
XPIC(CCDP) function
10 QPSK to 256QAM modulation at 14/28/56 MHz channel spacing
support
AMR, 1+1 and XPIC
11 AMR and 1+1, AMR and XPIC combination available
combination
DXC (E1 cross connect ) Up to 152 x 152 E1 non blocking
12
capacity
Clock Source for Equipment
13 E1/STM-1/Modem/SyncE/External Clock
Clock
External clock interface 2.048 MHz or 2.048 Mbps external clock input /output, 75 or 120 ohms selectable,
14
(option) D-sup 44 ways connector
DCN and Service channel outline
1 port, 10/100 Base-T RJ 45 (inband or outband connection available)
15 NMS interface
SNMPv1/v2c/v3
16 NE1 1 port, 10/100 Base-T, RJ 45
17 NE2 (RS485) 1 port, Serial signal port for legacy equipment, RJ 45
18 LCT (Local craft terminal) 1 port, 10/100Base-T, RJ 45, DHCP server support
Operation NWD-107461-04E
3-12/END System Configuration
NO Item IDU
House keeping and cluster
19 Input 6 ch, output 6 ch available with optional AUX card, D-sub 44 ways
alarm
20 Service channel 1 2 ports, RS-232C: 9.6 kbps async, D-sub 44 ways
21 Service channel 2 2 ports, V-11 (co or contra direction selectable) 64 kbps sync, D-sub 44 ways
22 Engineering order wire 1 port 4-wire voice channel, D-sub 44 ways
Far End Baseband Loop Back
23 Loop Back Near End Baseband Loop Back
IF Loop Back
24 Modem TX output Control Manual control, Automatic control (ATPC), Mute control
PMON Items;
a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS
Modem Metering Items
Performance Monitoring
25 a) Output power level (TX PWR), b) Received signal level (AGC V),
(PMON)/Metering
c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error
NWD-107461-04E Operation
NE Setup 4-1
4. NE SETUP
4.1 Login/Logout/Exit
4.1.1 Login NE
Users are registered by means of login name and password. To protect the network
and network management system from unauthorized access or unauthorized
modifications, three levels (refer to the table shown in section 4.3.2 User Account
Management) of users are defined with different privileges. The functions available
in the window depend on the user’s access level. Therefore, some of the functions
may or may not be carried out.
The highest or administrator level (Admin) has full access to the network and
network management system.
Procedure 4-1
3. Select Start -> Programs -> Internet Explorer from start menu.
4. The Internet Explorer window appears. Input the IP address of the NE and
WebLCT in URL Address box as shown below.
Ex: http://172.17.254.253/weblct/
Operation NWD-107461-04E
4-2 NE Setup
5. The WebLCT login window appears. Input user name and password in User
Name and Password textbox then press OK.
The following is the default user name and password for iPASOLINK 100/200:
• Password : 12345678
NWD-107461-04E Operation
NE Setup 4-3
4.1.2 Logout NE
Procedure 4-2
1. Click Logout button in the right top of the WebLCT main window.
Operation NWD-107461-04E
4-4 NE Setup
• Select File (F) -> Exit from the Internet Explorer menu bar.
NWD-107461-04E Operation
NE Setup 4-5
Click Refresh button to update the current status of the WebLCT main
window.
This part shows a list of NE on the opposite site, user can select the NE from the
Operation NWD-107461-04E
4-6 NE Setup
Click the corresponding tab to switch among the different event log view.
This part shows the tree view of the relevant configuration and provisioning
menu of the equipment.
Select this menu to show the equipment current status or history events for
each part of the NE (Active Alarm, Event Log, ODU, IDU, AUX).
Follow the Easy Setup Wizard to setup the basic configuration of the
equipment. The wizard includes ODU and IDU package registering,
removing function. This wizard provides a easier way to setup cross connect,
VLAN service and other necessary configuration for a new equipment.
Select this menu to register or remove ODU and IDU package and other
relevant configuration.
(d) Provisioning
Select this menu to configure the detail settings of the IDU and ODU.
NWD-107461-04E Operation
NE Setup 4-7
Select this menu to browse the report of Current, History, PMON and
RMON. User can also export the data to external storage (Local PC, USB
Memory). (For more details, refer to Maintenance Manual)
(h) Metering
Select this menu to measure the real time TX power, RX level, ODU power
supply and BER.
Select this menu to add, remove and modify user account of the equipment,
and setup user account security.
(k) Inventory
Select this menu to browse inventory information about the Equipment and
Software License.
Select this menu to import S/W License key and set Radio capacity.
Operation NWD-107461-04E
4-8 NE Setup
z Access Level
There are three user access levels with different privilege in iPASOLINK as
shown in the following table. For details of available operations of each access
level, refer to Table 4-3 User Access Privilege Levels.
Note: About the terms Upload and Download mentioned in the table above,
refer to the following description.
1. Upload means copy the file from NE to external storage, such as WebLCT
PC.
2. Download means copy the file from external storage to the equipment
internal storage.
z User Group
User Group configuration allow user to manage the Protocol Type and Access
Level for each group.
The user that assigned to the specified user group in iPASOLINK will be
assigned with pre-defined protocol and access level of the group.
Beside of the three default user groups, user can add up to six user groups
additionally. The default user groups are shown below.
Note: User can not change the options of default user group.
NWD-107461-04E Operation
NE Setup 4-9
Operation NWD-107461-04E
4-10 NE Setup
NWD-107461-04E Operation
NE Setup 4-11
Operation NWD-107461-04E
4-12 NE Setup
NWD-107461-04E Operation
NE Setup 4-13
Procedure 4-3
2. Select Login User List from the User Account/Security Setting sub
menu.
This function is for registering new user accounts, modifying and deleting existing
user account in iPASOLINK.
Note: This function is available for Admin access level user only.
This function is for registering the new user account other than the existing user
account.
Note: Up to nine user accounts can be added beside of the three default user
accounts.
Operation NWD-107461-04E
4-14 NE Setup
Procedure 4-4
3. The User Account Management window appears. Click Add User button.
4. The User Setting dialog box appears. Enter the proper value for each
parameter.
NWD-107461-04E Operation
NE Setup 4-15
Operation NWD-107461-04E
4-16 NE Setup
5. Click Set Password in the User Setting dialog box. The Set Password
box appears. Enter the same password into New Password and Re-Enter
boxes and then click OK button.
6. The User Setting dialog box appears again. Click OK button to close the
dialog box.
Note: Selection of Auth / Priv Algorithm will change according to the security
level below.
NWD-107461-04E Operation
NE Setup 4-17
z Security Level
Operation NWD-107461-04E
4-18 NE Setup
NWD-107461-04E Operation
NE Setup 4-19
For AuthPriv, Auth Algorithm, Auth key and Pri Algorithm Priv Key are
selectable.
Operation NWD-107461-04E
4-20 NE Setup
8. Click OK button after specifying the proper value for each parameter.
NWD-107461-04E Operation
NE Setup 4-21
10. The User Account Management window appears again. Confirm the user
account information displayed.
Procedure 4-5
3. The User Account Management window appears. Click the desired user
account.
Operation NWD-107461-04E
4-22 NE Setup
User Account
4. The User Setting box appears. Specify the proper value of each parameter.
• Select the user group from Group Name dropdown list to change the user
group of the user.
• Click Set Password on the top of the User Setting box to change the current
password. Enter the new password into New Password and Re-Enter on the
Set PassWord box.
NWD-107461-04E Operation
NE Setup 4-23
5. The User Setting dialog box appears again. Click OK button after inputting all
the information.
Operation NWD-107461-04E
4-24 NE Setup
Procedure 4-6
NWD-107461-04E Operation
NE Setup 4-25
4. The User Setting box appears. Select the user account from drop-down list and
click OK button.
5. The Confirmation box appears. Confirm the user name being deleted and then
click OK button.
Operation NWD-107461-04E
4-26 NE Setup
7. The User Account Management window appears again. Confirm that the
user has been deleted.
This setting is for registering and modifying the user group profiles.
The privilege of iPASOLINK user is subject to change according to the assigned user
access level and protocols that specified in the User Group Profile.
This function is for registering the new User Group Profile other than the default
User Group Profile.
Note: Up to six User Group Profiles can be registered beside of the three default
User Group Profiles.
This function is for modifying the existing User Group Profile (Access Level and
Protocol).
NWD-107461-04E Operation
NE Setup 4-27
Procedure 4-7
3. Click Add Group on the top of the User Group Profile Configuration
window.
Add Group button
4. The Group Setting box appears. Specify the proper value for each parameter
and the click OK button.
Operation NWD-107461-04E
4-28 NE Setup
NWD-107461-04E Operation
NE Setup 4-29
Procedure 4-8
3. The User Group Profile Configuration window appears. Click the desired
Group Name.
Group Name
4. The Group Setting box appears. Modify the parameters accordingly and then
click OK button.
Operation NWD-107461-04E
4-30 NE Setup
• Select the proper Access Level from drop-down list to change the access level of
the user group.
7. The User Group Profile Configuration window appears again. Confirm the
user group profile information displayed.
Note: A user group can be deleted only when no user account has been
assigned to the user group.
Procedure 4-9
NWD-107461-04E Operation
NE Setup 4-31
4. The Group Setting box appears. Select the Group profile name from the
drop-down list.
5. The Confirmation box appears. Confirm that the User Group name is deleted
and then click OK button.
Operation NWD-107461-04E
4-32 NE Setup
7. The User Group Profile Configuration window appears again. Confirm the
User Group Profile information displayed.
NWD-107461-04E Operation
NE Setup 4-33
- GET/SET of MIB
By default iPASOLINK uses the port 161 to receive the SNMP request UDP. If
user wants to use the pot other than the default one, it can be changed via the
WebLCT.
Operation NWD-107461-04E
4-34 NE Setup
- Send Trap
iPASOLINK can send SNMPv1 trap activity to UDP port 162, and up to three
destination IP addresses can be registered in advance. User also can specify the
community name and PDU type.
NWD-107461-04E Operation
NE Setup 4-35
- GET/SET of MIB
By default iPASOLINK uses the port 161 to receive the SNMP request UDP. If
user wants to use the pot other than the default one, it can be changed via the
WebLCT.
- Send Trap
iPASOLINK can send SNMPv2 trap activity to UDP port 162, and up to three
destination IP addresses can be registered in advance. User also can specify the
community name and PDU type.
Operation NWD-107461-04E
4-36 NE Setup
NWD-107461-04E Operation
NE Setup 4-37
- GET/SET of MIB
Response the request of PDU (Protocol Data Unit) that correspond by SNMPv3
- Send Trap
Available to send SNMPv3-Trap and destination UDP Port No. are 162 among
SNMPv1, v2c, v3.
SNMP, IP address of entity, security level, and user name will require for setting
destination of Trap for SNMPv3.
Operation NWD-107461-04E
4-38 NE Setup
User authentication will be execute if send the SNMP request that security level
is authNoPriv or authPriv.
This protocol is for synchronizing the time between server and client connecting
in network and specified by the following RFC.
iPASOLINK uses NTP Client and Server to provide the following functions:
- As NTP Client
In case that the unicast mode is selected on NTP Client, client sends a request of
the current time to the pre-configured server and then sets the time according to
information in the reply. Up to four NTP severs can be registered via the
WebLCT.
In case that the multicast mode is selected on NTP Client, client will listen the
broadcast of the time server and then set the time according to the first received
valid broadcast and ignore the broadcasts from other servers if any.
NTP Client received neither reply nor broadcasts which cause synchronization
cannot be accomplished, and current time of the equipment will be used.
NWD-107461-04E Operation
NE Setup 4-39
- As NTP Server
In case that the unicast mode is selected on NTP server, server will reply the
client with his time information.
In case the multicast mode is selected, server will broadcast his time information
periodically.
This protocol is for transferring the file among network equipments, and
specified by the following RFC.
Provide the data upload and download service; however data download is
available only when user is assigned with the proper privilege (refer to 4.3.1
User Access Levels).
The files and the directories that can be accessed via FTP protocol are
predetermined as well as the file name and type which will be downloaded.
- Session management
Accept the connection from external device then conduct Login Authentication
process. Anonymous user is not available.
Using the default TCP port 21 for listening and transferring the file on TCP port
20, user can change the default setting by the WebLCT. When Passive Mode is
selected, the port number is decided by the equipment automatically.
Operation NWD-107461-04E
4-40 NE Setup
HTTP is the protocol for transferring data between Web server and client
(WebLCT).
- WebLCT
- Session Management
Accepts the connection from external device then conduct Login Authentication
process. Anonymous user is not available.
The default port number of HTTP service is 80, and user can change it on the
WebLCT.
NWD-107461-04E Operation
NE Setup 4-41
Procedure 4-10
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Confirm the status of each
Service.
Operation NWD-107461-04E
4-42 NE Setup
NWD-107461-04E Operation
NE Setup 4-43
4.3.4.2 SNMP
Procedure 4-11
3. Select Service Status Setting from the Security Management sub menu.
Click SNMP.
5. The SNMP Setting box appears. Specify a proper value for each parameter.
Operation NWD-107461-04E
4-44 NE Setup
NWD-107461-04E Operation
NE Setup 4-45
Caution
You must reboot the CPU for applying the value properly after changing the
UDP port number.
Operation NWD-107461-04E
4-46 NE Setup
Registers, modifies, or deletes the SNMP Manager information. Only the registered
SNMP managers have the right to access to the equipment. Up to ten servers can be
registered.
Procedure 4-12
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click Community No. of the
SNMP Community field.
NWD-107461-04E Operation
NE Setup 4-47
Community No.
Operation NWD-107461-04E
4-48 NE Setup
8. The Service Status Setting window appears again. Confirm the newly added
SNMP community information displayed.
Procedure 4-13
3. Select Service Status Setting from the Security Management sub menu.
NWD-107461-04E Operation
NE Setup 4-49
Community No.
Operation NWD-107461-04E
4-50 NE Setup
8. The Service Status Setting window appears again. Confirm the SNMP
Community information displayed.
Procedure 4-14
3. Select Service Status Setting from the Security Management sub menu.
4. Click Delete SNMP Community on the top of the Service Status Setting
window.
NWD-107461-04E Operation
NE Setup 4-51
5. The Delete SNMP Community box appears. Select the SNMP Community
No. from the drop-down list, and then click OK button.
Operation NWD-107461-04E
4-52 NE Setup
8. The Service Status Setting window appears again. Confirm the SNMP
Community information displayed.
Procedure 4-15
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click SNMP Trap Entry No.
of the SNMP Trap Entry field.
NWD-107461-04E Operation
NE Setup 4-53
5. The SNMP Trap Entry box appears. Specify a proper value for each parameter.
(a) SNMPv1
Operation NWD-107461-04E
4-54 NE Setup
(b) SNMPv2c
(c) SNMPv3
NWD-107461-04E Operation
NE Setup 4-55
Operation NWD-107461-04E
4-56 NE Setup
8. The Service Status Setting window appears again. Confirm newly added
SNMP trap entry information displayed.
Procedure 4-16
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click SNMP Trap Entry No.
of the SNMP Trap Entry field.
NWD-107461-04E Operation
NE Setup 4-57
5. The SNMP Trap Entry box appears. Modify the parameters accordingly.
Operation NWD-107461-04E
4-58 NE Setup
8. The Service Status Settings window appears again. Confirm the SNMP trap
entry information displayed.
Procedure 4-17
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click Delete SNMP Trap
Entry.
Delete SNMP Trap Entry
NWD-107461-04E Operation
NE Setup 4-59
5. The Delete SNMP Trap Entry box appears. Select the SNMP Trap Entry
No. from the drop-down list, and then click OK button.
8. The Service Status Setting window appears again. Confirm the SNMP Trap
Entry information displayed.
Operation NWD-107461-04E
4-60 NE Setup
4.3.4.5 NTP
Procedure 4-18
3. Select Service Status Setting from the Security Management sub menu.
Click NTP.
5. The NTP Setting box appears. Assign a proper value for each parameter.
NWD-107461-04E Operation
NE Setup 4-61
Operation NWD-107461-04E
4-62 NE Setup
8. The Service Status Setting window appears again. Confirm the NTP
configuration displayed.
NWD-107461-04E Operation
NE Setup 4-63
Procedure 4-19
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click NTP Server No. of the
NTP Server Address field.
5. The NTP Server Address Setting box appears. Assign a proper value for
each parameter.
Operation NWD-107461-04E
4-64 NE Setup
8. The Service Status Setting window appears. Confirm newly added NTP
Server Address information displayed.
NWD-107461-04E Operation
NE Setup 4-65
Procedure 4-20
3. Select Service Status Setting from the Security Management sub menu.
4. Service Status Setting window appears. Click the NTP Server No. of the
NTP Server Address field.
Operation NWD-107461-04E
4-66 NE Setup
5. The NTP Server Address Setting box appears. Modify the parameters
accordingly.
NWD-107461-04E Operation
NE Setup 4-67
8. The Service Status Setting window appears again. Confirm the NTP Server
Address information displayed.
Procedure 4-21
3. Select Service Status Setting from the Security Management sub menu.
4. The Service Status Setting window appears. Click Clear NTP Server.
Operation NWD-107461-04E
4-68 NE Setup
5. The Clear NTP Server box appears. Select the NTP Server Address number
from drop-down list, and then click OK button.
NWD-107461-04E Operation
NE Setup 4-69
8. The Service Status Setting window appears again. Confirm the NTP Server
Address information displayed.
4.3.4.7 FTP
Procedure 4-22
3. Select Service Status Setting from the Security Management sub menu.
Operation NWD-107461-04E
4-70 NE Setup
Click FTP.
5. The FTP Setting box appears. Assign a proper value for each parameter.
NWD-107461-04E Operation
NE Setup 4-71
8. The Service Status Setting window appears again. Confirm the FTP
information displayed.
Operation NWD-107461-04E
4-72 NE Setup
4.3.4.8 HTTP
Procedure 4-23
NWD-107461-04E Operation
NE Setup 4-73
3. Select Service Status Setting from the Security Management sub menu.
Click HTTP.
5. The HTTP Setting box appears. Assign a proper value for each parameter.
Operation NWD-107461-04E
4-74 NE Setup
8. The Service Status Setting window appears again. Confirm the HTTP
information displayed.
NWD-107461-04E Operation
NE Setup 4-75
z Easy Setup
Setting of NE Name, Switch Group (System structure) and guide to other setups.
z MODEM Setup
z Management Setup
Setting for IP address, Subnet mask and default gateway for NE.
z TDM Setup
z ETH Setup
The easy setup is a wizard that guides the user to set up the basic configuration by
following the correct sequences.
Procedure 4-24
2. Select the Easy Setup from the Easy Setup Wizard sub menu.
Operation NWD-107461-04E
4-76 NE Setup
Setup button.
4. The Easy Setup - Step1 window appears. Enter the equipment name then
click Next button.
NWD-107461-04E Operation
NE Setup 4-77
Next button
Note
The left part of the window shows the current setup while on the right part of
the window, user can edit the configuration.
5. The Easy Setup - Step2 window appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
4-78 NE Setup
6. The Easy Setup – Step3 window appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
NE Setup 4-79
8. The Easy Setup - Step4 window appears. The parameters that have been
modified will be marked with blue background. Confirm the value of the
parameters and then OK button.
Operation NWD-107461-04E
4-80 NE Setup
11. The MODEM Setup wizard appears. Refer to the next sub section for details.
NWD-107461-04E Operation
NE Setup 4-81
Procedure 4-25
1. After Easy Setup wizard is completed or MODEM Setup is selected from the
Easy Setup Wizard sub menu, click the Setup button.
2. The MODEM Setup - Step1 window appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
4-82 NE Setup
3. Click Next button after configuring the parameters. (When two MODEMs are
used, setup window for MODEM2 appears. Configure the parameters for
MODEM2.)
4. The MODEM Setup - Step2 window appears. The parameters that have been
modified will be marked with blue background. Confirm the value of the
parameters and then click OK button.
NWD-107461-04E Operation
NE Setup 4-83
7. The Management Setup wizard appears. Refer to the next sub section for
details.
Operation NWD-107461-04E
4-84 NE Setup
Note: The Warning box appears Click Maintenance button on the top of the
LCT window to turn on maintenance mode.
Procedure 4-26
3. Click OK button.
NWD-107461-04E Operation
NE Setup 4-85
5. The Management Setup wizard appears. Refer to the next sub section for
details.
Procedure 4-27
Operation NWD-107461-04E
4-86 NE Setup
3. The TDM XC Configuration window appears. Specify the proper value for
each parameter and then click OK button.
OK button
NWD-107461-04E Operation
NE Setup 4-87
6. The ETH Setup wizard appears. Refer to the next sub section for details.
Procedure 4-28
1. After the TDM Setup wizard is completed or ETH Setup is selected from the
Easy Setup Wizard sub menu, the ETH Setup wizard appears. Click Setup
button.
Next button
Operation NWD-107461-04E
4-88 NE Setup
Notes
1. EPL (Ethernet Private Line)
EPL is a data service defined by the Metro Ethernet Forum, providing a
point-to-point Ethernet connection between a pair of dedicated
User-Network Interfaces (UNIs), with a high degree of transparency.
EPL service is specified using an E-Line service type, with an expectation of
low Frame Delay, Frame Delay Variation and Frame Loss Ratio. EPL is
implemented as a point-to-point Ethernet Virtual Connection (EVC) which,
unlike Ethernet Virtual Private Line (EVPL), does not allow for Service
Multiplexing, i.e., a dedicated UNI (physical interface) is used to accept all
service frames and map them to a single EVC (a.k.a. All-to-one bundling).
Due to a high degree of transparency, EPL is often used to provide
point-to-point Transparent LAN Service (TLS), where the Service Frame’s
header and payload are identical at both the source and destination UNI.
EPL is not fully transparent, as it must filter IEEE 802.3x Pause frames.
2. EVPL (Ethernet Virtual Private Line)
Ethernet Virtual Private Line (EVPL) is a data service defined by the Metro
Ethernet Forum, providing a point-to-point Ethernet connection between a
pair of User-Network Interfaces (UNIs).
EVPL service is specified using an E-Line service type, very similar to a
Ethernet Private Line (EPL) service, via a point-to-point Ethernet Virtual
Connection (EVC). However, unlike EPL, EVPL allows for Service
Multiplexing, i.e., multiple EVCs or Ethernet services per UNI.
The other difference between the EVPL and EPL is the degree of
transparency - while EPL is highly transparent, filtering only the Pause
frames, EVPL is required to either peer or drop most of the Layer 2 Control
Protocols.
NWD-107461-04E Operation
NE Setup 4-89
OK button
Notes
1. Ethernet Private LAN (EPLAN) is a Metro Ethernet service type defined by
the Metro Ethernet Forum.
Because E-LAN services implement multipoint-to-multipoint Ethernet virtual
connections (EVC), multiple locations can be interconnected using an
EPLAN service. However, each location can be a member of one and only
one EVC. If a given location requires connection to a second EVC, it will
require a second UNI.
Because there is only one EVC per UNI, the EVC can be invisible to the
customer (e.g., the customer will not see an 802.1p VLAN tag).
Operation NWD-107461-04E
4-90 NE Setup
NWD-107461-04E Operation
NE Setup 4-91
Operation NWD-107461-04E
4-92 NE Setup
• Equipment Configuration
• Radio Configuration
• AMR Configuration
Setting for IP Address of each port and functions that mounted at the front face
of iPASOLINK
NWD-107461-04E Operation
NE Setup 4-93
Procedure 4-29
Setup button
4. The Step1 window appears. Input Equipment Name and then click Next
button.
Operation NWD-107461-04E
4-94 NE Setup
Note
The left part of the window shows the current setup while on the right part of the
window, user can edit the configuration.
5. The Step2 window appears, input necessary parameter, and then click Next
button.
NWD-107461-04E Operation
NE Setup 4-95
6. The Step3 window appears, input necessary parameter, and then click Next
button.
Operation NWD-107461-04E
4-96 NE Setup
Next button
7. The Step4 window appears. Confirm that the setup parameter changes to blue,
and then click OK button.
NWD-107461-04E Operation
NE Setup 4-97
Operation NWD-107461-04E
4-98 NE Setup
Procedure 4-30
NWD-107461-04E Operation
NE Setup 4-99
Setup button
4. The Step1 window appears. Input all necessary parameters and then click Next
button.
Operation NWD-107461-04E
4-100 NE Setup
Next button
NWD-107461-04E Operation
NE Setup 4-101
Operation NWD-107461-04E
4-102 NE Setup
6. The Step2 window appears. Confirm that the setup parameter changes to blue
then click OK button.
NWD-107461-04E Operation
NE Setup 4-103
Procedure 4-31
Operation NWD-107461-04E
4-104 NE Setup
Setup button
4. The Step1 window appears. Assign a proper value for each parameter for
MODEM1.
NWD-107461-04E Operation
NE Setup 4-105
6. The Step2 window appears. Setup E1 Mapping of the AMR Range field
[QAM].
Operation NWD-107461-04E
4-106 NE Setup
7. The Step1 window appears again. Assign a proper value for each parameter for
MODEM2.
9. The Step2 window appears again. Setup E1 Mapping of the AMR Range
field [QAM].
NWD-107461-04E Operation
NE Setup 4-107
11. The Step3 window appears. Confirm that the setup parameter changes to blue,
and then click OK button.
Operation NWD-107461-04E
4-108 NE Setup
13. The AMR Configuration window appears. Confirm that all parameters are set.
In this menu execute the setting of function for each port mounted on front face of
iPASOLINK.
NWD-107461-04E Operation
NE Setup 4-109
• General Setting
In order to connect the iPASOLINK and NMS, execute the setting for using/un
using of NMS Port and IP Address.
Setting for IP Address of each port (NE2, Inband Management VLAN) and NE
Branch (NMS/NE/MODEM)
• Routing Setting
Procedure 4-32
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
2. Expand Equipment Setup from the WebLCT menu.
Operation NWD-107461-04E
4-110 NE Setup
9. The General Setting window appears again. Confirm that all parameters are
set.
NWD-107461-04E Operation
NE Setup 4-111
10. After finishing General Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.
Procedure 4-33
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
Operation NWD-107461-04E
4-112 NE Setup
Setup button
6. The General Setting (Detail) box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
NE Setup 4-113
Operation NWD-107461-04E
4-114 NE Setup
NWD-107461-04E Operation
NE Setup 4-115
8. The General Setting (Detail) box appears again. Click Bridge No. of the NE
Branch Setting field.
Bridge No.
Operation NWD-107461-04E
4-116 NE Setup
9. The IP Address Setting box appears. Input the IP address and the subnet
mask, and then click OK button.
NWD-107461-04E Operation
NE Setup 4-117
13. The General Setting (Detail) window appears again. Confirm that all
parameter are set.
14. After finishing General Setting (Detail), click Maintenance button on the top
of the WebLCT window to exit maintenance mode.
Operation NWD-107461-04E
4-118 NE Setup
This function provide user to specify the static route for the particular network or
IP address.
Procedure 4-34
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
Setup button
NWD-107461-04E Operation
NE Setup 4-119
7. The Routing Setting (Add) box appears. Input the IP Address, Subnet Mask,
and Gateway, and then click OK button.
8. The Routing Setting box appears again. Confirm the newly added route
information displayed.
Operation NWD-107461-04E
4-120 NE Setup
12. The Routing Setting window appears again. Confirm that the newly added
route information displayed.
NWD-107461-04E Operation
NE Setup 4-121
13. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.
Procedure 4-35
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
Setup button
Operation NWD-107461-04E
4-122 NE Setup
7. The Routing Setting (Modify) box appears. Modify the IP Address, subnet
mask and gateway accordingly then click OK button.
8. The Routing Setting box appears again. Confirm the route information
displayed.
NWD-107461-04E Operation
NE Setup 4-123
12. The Routing Setting window appears again. Confirm the route information
displayed.
Operation NWD-107461-04E
4-124 NE Setup
13. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.
Procedure 4-36
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
NWD-107461-04E Operation
NE Setup 4-125
Setup button
Delete button
7. The Routing Setting (Delete) box appears. Enter the network address
displayed in the list, and then click OK button.
Operation NWD-107461-04E
4-126 NE Setup
8. The Routing Setting box appears again. Confirm that the specified network
has been deleted, then click OK button.
NWD-107461-04E Operation
NE Setup 4-127
11. The Routing Setting window appears again. Confirm the route information
displayed.
12. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.
Operation NWD-107461-04E
4-128 / END NE Setup
NWD-107461-04E Operation
System Operation 5-1
5. SYSTEM OPERATION
5.1 Provisioning
This setup is for further system fundamental configuration after the equipment setup.
The setting items are listed as follows:
User can configure the port, radio switch, ATPC/MTPC power, E1/STM-1
threshold, and so on for each selected MODEM.
User can configure the Ethernet port, VLAN ETH OAM, RSTP, QOS, link loss
forwarding and so on.
User can configure the internal clock, external clock, timing source.
z V.11/OW Setting
z Alarm/AIS Setting
User can configure the alarm delay, severity, color and relevant settings of AIS.
z PMON/RMON Setting
User can configure the threshold of PMON (except Ethernet)/ RMON (Ethernet).
z AUX Setting
Operation NWD-107461-04E
5-2 System Operation
Specify the TX/RX switch priority that prevents from unnecessary switching.
z TX Power Setting
Specify the ATPC power mode and ALM mode when ODU communication
fails.
z AMR Setting
Procedure 5-1
3. Select MODEM Port Setting from the MODEM Function Setting sub
menu.
4. The MODEM Port Setting window appears. Click the desired MODEM to
configure.
NWD-107461-04E Operation
System Operation 5-3
5. The MODEM Port Setting dialog box appears. Assign a proper value for each
parameter.
8. The MODEM Port Setting window appears again. Confirm the displayed
parameters.
Operation NWD-107461-04E
5-4 System Operation
Specify the TX/RX SW priority and TXSW lockin usage, and TX SW reverse
function usage.
• TX SW Priority
This function is to prevent the TX switch from frequent switch over in case of
cable problem between IDU and ODU.
This function is to enable TX switch in case the opposite station detects the TX
transmit trouble of local station.
• RX SW Priority
NWD-107461-04E Operation
System Operation 5-5
Procedure 5-2
3. Select Radio Switch Setting from the MODEM Function Setting sub
menu.
4. The Radio Switch Setting window appears. Click the desired MODEM No.
(or SW GRP1) to configure.
SW GRP1.
5. The Radio Switch Setting dialog box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-6 System Operation
8. The Radio Switch Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-7
Procedure 5-3
3. Select TX Power Setting from the MODEM Function Setting sub menu.
4. The TX Power Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.
Operation NWD-107461-04E
5-8 System Operation
5. The TX Power Setting dialog box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-9
Procedure 5-4
3. Select TX Power Setting from the MODEM Function Setting sub menu.
4. The TX Power Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.
Operation NWD-107461-04E
5-10 System Operation
5. The TX Power Setting dialog box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-11
Specify the ATPC power mode and ALM mode when ODU communication fails.
Procedure 5-5
3. Select ALM Mode Setting from the MODEM Function Setting sub menu.
4. The ALM Mode Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.
Operation NWD-107461-04E
5-12 System Operation
5. The ALM Mode Setting dialog box appears. Assign a proper value for each
parameter.
Note: In case user has selected MTPC, “ATPC Power Mode” will be Invalid.
NWD-107461-04E Operation
System Operation 5-13
8. The ALM Mode Setting window appears again. Confirm the displayed
parameters.
Procedure 5-6
3. Select XPIC Setting from the MODEM Function Setting sub menu.
4. The XPIC Setting window appears. Click the XPIC GRP1 to configure.
Operation NWD-107461-04E
5-14 System Operation
XPIC GRP1
6. When the Lo signal to ODU from IDU becomes out of synchronization, either
ODU operation MUTE (default) or Self Lo (ODU self Lo operation) can be
selected
NWD-107461-04E Operation
System Operation 5-15
Procedure 5-7
3. Select AMR Setting from the MODEM Function Setting sub menu.
6. The AMR Setting dialog box appears. Assign a proper value for each parameter.
Operation NWD-107461-04E
5-16 System Operation
NWD-107461-04E Operation
System Operation 5-17
z Bridge Setting
Bridge function also known as switching function that enable the device in the
multiple network segments can communicate with each other. User can
configure the FDB (forward database) aging time, default VLAN ID and VLAN
mode here.
This function provide user the abilities that configure the attributes of the
Ethernet port on the front panel of iPASOLINK, including port name, line speed,
Mode, Flow Control etc.
z VLAN Setting
VLAN (Virtual Local Area Network) enable multiple devices which separated
physically can communicate as they are located in a same broadcast domain and
also protect the data from send to other domain even they may connected
physically.
This function provide user the abilities of create, configure and delete the VLAN.
z FDB Setting
iPASOLINK can learn the MAC address of the Ethernet frame dynamically and
save the port – MAC address mapping information into FDB (Forwarding
DataBase) based on IEEE802.1d for each VLAN. User can also add the static
mapping information manually by this function.
z RSTP Setting
User can set the priority of the bridge; specify the role of the Ethernet port and
other parameters.
Operation NWD-107461-04E
5-18 System Operation
z QoS/Classification Setting
This function provides additional setting of bridge such as Mirror port, layer 2
protocol transparency.
z LLF Setting
LLF (Link Loss Forwarding) is the function that mandatory shutdown the port on
the opposite device when local device detected unidirectional link problem.
Procedure 5-8
3. Select Bridge Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-19
Modify button
5. The Bridge Setting dialog box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-20 System Operation
8. The Bridge Setting window appears again. Confirm the displayed parameters.
Procedure 5-9
3. Select ETH Port Setting from the ETH Function Setting sub menu.
4. The ETH Port Setting window appears. Click the desired Port No. to
configure.
NWD-107461-04E Operation
System Operation 5-21
Port No.
5. The ETH Port Setting dialog box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-22 System Operation
*1 When AUTO of Speed is selected, Duplex and MDI and MDIX are not selectable.
8. The ETH Port Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-23
Procedure 5-10
3. Select VLAN Setting from the ETH Function Setting sub menu.
5. The VALN List tab appears. Click Add VLAN ID button to create a new
VLAN ID.
Operation NWD-107461-04E
5-24 System Operation
VLAN ID button
6. The Add VLAN ID dialog box appears. Refer to the table below to assign a
proper value for each parameter accordingly.
NWD-107461-04E Operation
System Operation 5-25
9. The VLAN Setting window appears again. Confirm the displayed parameters.
Procedure 5-11
3. Select VLAN Setting from the ETH Function Setting sub menu.
Operation NWD-107461-04E
5-26 System Operation
5. The VALN List tab appears. Click the VLAN Service Name to be modified.
6. The Modify VLAN Service Name box appears. Modify the VLAN Service
Name accordingly.
NWD-107461-04E Operation
System Operation 5-27
9. The VALN List tab appears again. Confirm the modified VLAN Service Name.
Operation NWD-107461-04E
5-28 System Operation
Procedure 5-12
3. Select VLAN Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-29
6. The Delete VLAN ID box appears. Input the VLAN ID or VLAN Service Name
to be deleted.
Operation NWD-107461-04E
5-30 System Operation
10. The VLAN List tab appears again. Confirm the VLAN ID has been deleted.
NWD-107461-04E Operation
System Operation 5-31
Procedure 5-13
3. Select VLAN Setting from the ETH Function Setting sub menu.
Port No.
5. The VLAN Setting window appears. Assign a proper value for each VLAN
Assignment field parameter.
Note: The views are different according to the configuration (Access/ Tunnel/
Trunk).
Operation NWD-107461-04E
5-32 System Operation
• Access
• Tunnel
NWD-107461-04E Operation
System Operation 5-33
• Trunk
Operation NWD-107461-04E
5-34 System Operation
8. The VLAN Setting window appears again. Confirm the parameters displayed.
Procedure 5-14
3. Select FDB Port Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-35
Equipment
5. The FDB Setting (Equipment) dialog box appears. Assign a proper value for
each parameter.
Operation NWD-107461-04E
5-36 System Operation
7. The FDB Setting tab appears again. Click the desired VLAN ID No. to
configure.
VLAN ID No.
8. The FDB Setting box appears. Assign a proper value for each parameter.
NWD-107461-04E Operation
System Operation 5-37
11. The FDB Setting tab appears again. Confirm the displayed parameters.
Procedure 5-15
3. Select FDB Port Setting from the ETH Function Setting sub menu.
4. The FDB Setting window appears. Click the Static Entry tab.
Operation NWD-107461-04E
5-38 System Operation
Add button
6. The Static Entry (Add) dialog box appears. Refer to the table below to assign
a proper value for each parameter accordingly.
NWD-107461-04E Operation
System Operation 5-39
9. The Static Entry tab appears again. Confirm the displayed parameters.
Operation NWD-107461-04E
5-40 System Operation
Procedure 5-16
3. Select FDB Port Setting from the ETH Function Setting sub menu.
4. The FDB Setting window appears. Click the Static Entry tab.
NWD-107461-04E Operation
System Operation 5-41
5. The Static Entry tab appears. Click the desired Entry No. to configure.
Entry No.
6. The Static Entry dialog box appears. Modify the MAC address accordingly.
Operation NWD-107461-04E
5-42 System Operation
9. The Static Entry tab appears again. Confirm the modified parameters of the
MAC address.
Procedure 5-17
3. Select FDB Port Setting from the ETH Function Setting sub menu.
4. The FDB Setting window appears. Click the Static Entry tab.
NWD-107461-04E Operation
System Operation 5-43
Delete buton
6. The Static Entry (Delete) dialog box appears. Check the static entry No. to
be deleted.
Operation NWD-107461-04E
5-44 System Operation
10. The Static Entry tab appears again. Confirm the static entry No. has been
deleted.
NWD-107461-04E Operation
System Operation 5-45
Procedure 5-18
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the OAM MEG tab.
Operation NWD-107461-04E
5-46 System Operation
5. The OAM MEG tab appears. Click the Add MEG button.
6. The OAM MEG Setting (Add) box appears. Refer to the table below to assign
a proper value for each parameter accordingly.
NWD-107461-04E Operation
System Operation 5-47
9. The OAM MEG tab appears again. Confirm the newly added MEG Index
information displayed.
Operation NWD-107461-04E
5-48 System Operation
Procedure 5-19
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the OAM MEG tab.
5. The OAM MEG tab appears. Click the Delete MEG button.
NWD-107461-04E Operation
System Operation 5-49
6. The OAM MEG Setting (Delete) box appears. Select the OAM MEG Index
No. to be deleted.
7. Click OK button.
Operation NWD-107461-04E
5-50 System Operation
10. The OAM MEG tab appears again. Confirm the OAM MEG has been deleted.
Procedure 5-20
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click Add MEP button in the OAM
MEP tab.
Add MEP button
5. The OAM MEP Setting (Add) dialog box appears. Select the Enable radio
button in the MEG Configuration field.
NWD-107461-04E Operation
System Operation 5-51
6. Click Add Peer MEP button in the Peer MEP Configuration field.
Operation NWD-107461-04E
5-52 System Operation
7. The Peer MEP Add box appears. Input the Peer MEP ID.
9. The OAM MEP Setting (Add) dialog box appears again. Refer to the table
below to assign a proper value for each parameter accordingly.
NWD-107461-04E Operation
System Operation 5-53
Operation NWD-107461-04E
5-54 System Operation
NWD-107461-04E Operation
System Operation 5-55
13. The OAM MEP tab appears again. Confirm the newly added MEP Index
information displayed.
Procedure 5-21
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the MEP Index No. to be
modified in the OAM MEP tab.
Operation NWD-107461-04E
5-56 System Operation
5. The OAM MEP Setting (Modify) dialog box appears. Modify the parameter
accordingly.
NWD-107461-04E Operation
System Operation 5-57
Operation NWD-107461-04E
5-58 System Operation
9. The OAM MEP tab appears again. Confirm the modified parameters of the
OAM MEP Index information displayed.
Procedure 5-22
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-59
4. The ETH OAM Setting window appears. Click Delete MEP button in the
OAM MEP tab.
5. The OAM MEP Setting (Delete) box appears. Select the OAM MEP Index No.
to be deleted.
6. Click OK button.
Operation NWD-107461-04E
5-60 System Operation
Note: In case that CCM Transmit / CCM Receive is enabled, if user try to
delete the MEP Index the following error message will appears:
Follow the procedure of (2) Modify OAM MEP Index, disable CCM
Transmit / CCM Receive first and then delete the MEP Index.
9. The OAM MEP tab appears again. Confirm the OAM MEP has been deleted.
Procedure 5-23
NWD-107461-04E Operation
System Operation 5-61
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the OAM MIP tab.
6. The OAM MIP Setting (Add) box appears. Refer to the table below to assign a
proper value for each parameter accordingly.
Operation NWD-107461-04E
5-62 System Operation
NWD-107461-04E Operation
System Operation 5-63
9. The OAM MIP tab appears again. Confirm the newly added OAM MIP
information displayed.
Procedure 5-24
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the OAM MIP tab.
Operation NWD-107461-04E
5-64 System Operation
5. The OAM MIP tab appears. Click the desired MIP Index No. to configure.
6. The OAM MIP Setting (Modify) box appears. Modify the parameter
accordingly.
NWD-107461-04E Operation
System Operation 5-65
9. The OAM MIP tab appears again. Confirm the modified parameters of the OAM
MIP information displayed.
Operation NWD-107461-04E
5-66 System Operation
Procedure 5-25
3. Select ETH OAM Setting from the ETH Function Setting sub menu.
4. The ETH OAM Setting window appears. Click the OAM MIP tab.
6. The OAM MIP Setting (Delete) box appears. Select the OAM MIP Index No.
to be deleted.
NWD-107461-04E Operation
System Operation 5-67
7. Click OK button.
10. The OAM MIP tab appears again. Confirm the OAM MIP Index has been
deleted.
Operation NWD-107461-04E
5-68 System Operation
Note STP/RSTP tunnel enable function is not supported for RSTP enabled
port.
Procedure 5-26
3. Select RSTP Setting from the ETH Function Setting sub menu.
4. The RSTP Setting window appears. Click Modify RSTP Port button.
NWD-107461-04E Operation
System Operation 5-69
5. The RSTP Port Setting window appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-70 System Operation
8. The RSTP Setting window appears again. Confirm the parameters displayed.
NWD-107461-04E Operation
System Operation 5-71
Procedure 5-27
3. Select RSTP Setting from the ETH Function Setting sub menu.
4. The RSTP Setting window appears. Click Modify Detail RSTP Parameter
button.
Operation NWD-107461-04E
5-72 System Operation
5. The Detail RSTP Parameter Setting box appears. Assign a proper value for
each parameter.
NWD-107461-04E Operation
System Operation 5-73
8. The RSTP Setting window appears again. Confirm the parameters displayed.
Operation NWD-107461-04E
5-74 System Operation
NWD-107461-04E Operation
System Operation 5-75
iPASOLINK supports QoS based on MEF10 and REC4115 which classify the
traffic into eight classes with the proper Internal Priority according to the
predetermined Policer. Except the default Policer, user can configure up to three
additional Policer which provide user the capability of realizing the
user-orientation QoS strategy flexibly. The Internal Priority is used for following
purpose:
2) Mapping the eight classes of ingress traffic to four classes when queueing the
Egress traffic.
3) Copy the original internal priority to the capsulated frame to prevent the
traffic priority from changing unexpectedly. (VLAN c-tag CoS/VLAN s-tag
CoS)
z Ingress
At the Ingress of the traffic, assign the internal priority and then perform flow
control according to the predetermined policer, coloring the frame with Yellow
or Green which decide the QoS queue at the egress, discarding the frames of the
traffic that exceed the designated bandwidth (EIR, Excess Information Rate).
z Egress
Queueing the frame according to the internal priority and the color assigned at
ingress, determine forwarding or discarding the frame.
Operation NWD-107461-04E
5-76 System Operation
Procedure 5-28
10. Expand ETH Function Setting from the Provisioning sub menu.
11. Select QoS/Classification Setting from the ETH Function Setting sub
menu.
13. The Classification Mode window appears. Select the Equipment Based
QoS Mode
NWD-107461-04E Operation
System Operation 5-77
Procedure 5-29
Operation NWD-107461-04E
5-78 System Operation
Entry No.
6. The Classify Entry Setting box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-79
Operation NWD-107461-04E
5-80 System Operation
Procedure 5-30
NWD-107461-04E Operation
System Operation 5-81
6. The Delete Entry box appears. Assign a proper value for each parameter and
then click OK button.
Operation NWD-107461-04E
5-82 System Operation
Procedure 5-31
NWD-107461-04E Operation
System Operation 5-83
5. The Select profile No. box appears. Assign a proper value for drop-down list.
Operation NWD-107461-04E
5-84 System Operation
Procedure 5-32
3. Select QoS/Classification Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-85
5. The Classification Mode window appears. Select the Port Based QoS
Mode
Operation NWD-107461-04E
5-86 System Operation
Procedure 5-33
5. The Port Classification Mode Setting window appears. Select the object
from Port Classification Mode drop-down list and Assign a proper value for
Default Port Priority.
NWD-107461-04E Operation
System Operation 5-87
Procedure 5-34
Operation NWD-107461-04E
5-88 System Operation
5. The Ingress Setting tab appears. Click the Add Policer Index button.
6. The Add Policer Index box appears. Assign a proper value for each parameter.
NWD-107461-04E Operation
System Operation 5-89
8. The Ingress Policer Profile Detail Setting box appears. Assign a proper
value for each parameter
Operation NWD-107461-04E
5-90 System Operation
Note You need to set Ebs value bigger than MTU size of the policer applying
port.
11. The Add Policer Index box appears again. Click OK Button.
NWD-107461-04E Operation
System Operation 5-91
13. The Ingress Setting tab appears again. Confirm the newly added Ingress
Policer Index information displayed
Operation NWD-107461-04E
5-92 System Operation
Procedure 5-35
NWD-107461-04E Operation
System Operation 5-93
5. The Ingress Setting tab appears. Click the Ingress Policer Profile Setting
button.
6. The Ingress Policer Profile Setting box appears. Click the desired Ingress
Policer Index No. to configure.
Operation NWD-107461-04E
5-94 System Operation
7. The Ingress Policer Profile Detail Setting box appears. Assign a proper
value for each parameter
NWD-107461-04E Operation
System Operation 5-95
10. The Ingress Policer Profile Setting box appears again. Click Close button.
11. The Ingress Setting tab appears again. Confirm the parameters displayed.
Operation NWD-107461-04E
5-96 System Operation
Procedure 5-36
NWD-107461-04E Operation
System Operation 5-97
5. The Ingress Setting tab appears. Click the desired Pollcer Index No to
configure.
Pollcer Index No
6. The Ingress Policer Setting box appears. Modify the parameter accordingly.
Operation NWD-107461-04E
5-98 System Operation
9. The Ingress Setting tab appears again. Confirm the modified parameters of
the Ingress Policer Index information displayed.
NWD-107461-04E Operation
System Operation 5-99
Procedure 5-37
Operation NWD-107461-04E
5-100 System Operation
5. The Ingress Setting tab appears. Click Delete Policer Index button.
6. The Delete Policer Index box appears. Input the Ingress Pollcer Index No.
to be deleted.
NWD-107461-04E Operation
System Operation 5-101
7. Click OK button.
10. The Ingress Setting tab appears again. Confirm the Ingress Policer Index
No. has been deleted
Operation NWD-107461-04E
5-102 System Operation
Procedure 5-38
NWD-107461-04E Operation
System Operation 5-103
5. The Port Setting tab appears. Click the desired Main Board or MODEM
Port No. to configure.
6. The Qos Port Setting box appears. Assign a proper value for each parameter.
Operation NWD-107461-04E
5-104 System Operation
Class No.
7. Click the desired Class No. of the Egress Class Setting Information field.
8. The Egress Class Setting box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-105
Operation NWD-107461-04E
5-106 System Operation
Class 3
SP
DWRR
11. The Qos Port Setting box appears again. Click OK button after setting the
parameters.
NWD-107461-04E Operation
System Operation 5-107
13. The Port Setting tab appears again. Confirm the parameters displayed.
Operation NWD-107461-04E
5-108 System Operation
Procedure 5-39
3. Select Other ETH Port Setting from the ETH Function Setting sub menu.
4. The Other ETH Port Setting window appears. Click the desired Port No to
configure.
Port No.
NWD-107461-04E Operation
System Operation 5-109
5. The Other ETH Port Setting box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-110 System Operation
Note STP/RSTP tunnel enable function is not supported for RSTP enabled
port.
8. The Other ETH Port window appears again. Confirm the parameters displayed.
Procedure 5-40
3. Select LLF Setting from the ETH Function Setting sub menu.
NWD-107461-04E Operation
System Operation 5-111
5. The LLF Setting (Add) box appears. Refer to the table below to assign a
proper value for each parameter accordingly
Operation NWD-107461-04E
5-112 System Operation
8. The LLF Setting window appears again. Confirm the newly added LLF Setting
information displayed.
NWD-107461-04E Operation
System Operation 5-113
Procedure 5-41
3. Select LLF Setting from the ETH Function Setting sub menu.
4. The LLF Setting window appears. Click the desired LLF GRP No. to
configure.
5. The LLF Setting (Modify) box appears. Modify the parameter accordingly.
Operation NWD-107461-04E
5-114 System Operation
8. The LLF Setting window appears again. Confirm the modified parameters of
the LLF GRP information displayed.
NWD-107461-04E Operation
System Operation 5-115
Procedure 5-42
3. Select LLF Setting from the ETH Function Setting sub menu.
5. The LLF Setting (Delete) box appears. Select the LLF GRP ID to be deleted.
Operation NWD-107461-04E
5-116 System Operation
9. The LLF Setting window appears again. Confirm the LLF GRP has been
deleted.
NWD-107461-04E Operation
System Operation 5-117
Procedure 5-43
3. Select Broadcast Storm Control from the ETH Function Setting sub
menu.
Operation NWD-107461-04E
5-118 System Operation
5. The Broadcast Storm Control Rate dialog box appears. Enter storm control
rate 1 to 1000 Mbps.
6. Click OK button. The Broadcast Storm Control Rate dialog box closes. The
entered rate is indicated at the right field of the Broadcast Storm Control
Rate button.
7. Click Port No at the Item/Port Information for Main Board or MODEM1/2. The
Broadcast Storm Control (Main Board – Port-0x) or (MODEM –
Port-0x) dialog box appears.
NWD-107461-04E Operation
System Operation 5-119
Figure 5-210 Broadcast Storm Control Rate Dialog Box (Main Board)
9. Click OK button. The dialog box closes, and the Broadcast Storm Control
Setting window appears again.
Operation NWD-107461-04E
5-120 System Operation
• E1 Port Setting
Configure the STM-1 Port Mode, Usage, AIS generation, ALS (Automatic Laser
Shutdown) and tree setting.
Configure Cross Connect, and confirm current Cross Connect and Port (CH)
utilization.
Procedure 5-44
NWD-107461-04E Operation
System Operation 5-121
Modify button
5. The E1 Port Setting (Main Board) dialog box appears. Refer to the table
below to assign a proper value for each parameter.
Operation NWD-107461-04E
5-122 System Operation
NWD-107461-04E Operation
System Operation 5-123
8. The E1 Port Setting window appears again. Confirm the displayed parameters.
Operation NWD-107461-04E
5-124 System Operation
Configure the STM-1 port mode, usage, AIS generation, ALS (Automatic Laser
Shutdown) and tree setting.
Procedure 5-45
Modify button
5. The STM-1 Port Setting dialog box appears. Refer to the table below to assign
a proper value for each parameter.
NWD-107461-04E Operation
System Operation 5-125
Operation NWD-107461-04E
5-126 System Operation
8. The STM-1 Port Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-127
User can add, edit and delete the Cross Connect. Upto152 cross connections in total
can be created
In addition, if a user sets the Cross Connect Type to RST when Add Cross Connect,
Port (CH) utilization can be observed.
iPASOLINK supports 2M E1 level Cross Connect. The packets that support Cross
Connect are listed in the following table.
Operation NWD-107461-04E
5-128 System Operation
1 1 1 1
2 2 1 1
3 3 1 1
4 1 2 1
5 2 2 1
6 3 2 1
7 1 3 1
8 2 3 1
9 3 3 1
10 1 4 1
11 2 4 1
12 3 4 1
13 1 5 1
14 2 5 1
15 3 5 1
16 1 6 1
17 2 6 1
18 3 6 1
19 1 7 1
20 2 7 1
21 3 7 1
22 1 1 2
23 2 1 2
24 3 1 2
25 1 2 2
26 2 2 2
27 3 2 2
28 1 3 2
29 2 3 2
30 3 3 2
31 1 4 2
NWD-107461-04E Operation
System Operation 5-129
63 3 7 3
Operation NWD-107461-04E
5-130 System Operation
Procedure 5-46
4. The Cross Connect Setting window appears. Click Add button to create a
new cross connection.
Add button
5. The Cross Connect Setting (Add) dialog box appears. Refer to the table
below to assign a proper value for each parameter accordingly.
NWD-107461-04E Operation
System Operation 5-131
Operation NWD-107461-04E
5-132 System Operation
Note: The port number of the Edge.A/B Term1 on the mounted card or
MODEM is change according to the channel spacing.
8. The Cross Connect Setting window appears again. Confirm the newly added
cross connect information displayed.
NWD-107461-04E Operation
System Operation 5-133
Procedure 5-47
4. The Cross Connect Setting window appears. Click Add button to create a
new cross connect.
5. The Cross Connect Setting (Add) dialog box appears. Refer to the table
below to assign a proper value for each parameter accordingly.
Note
The Hold Off Time Setting button enables guard time setting for SNCP mode,
Operation NWD-107461-04E
5-134 System Operation
NWD-107461-04E Operation
System Operation 5-135
8. The Cross Connect Setting window appears again. Confirm the newly added
cross connect information displayed.
Operation NWD-107461-04E
5-136 System Operation
Procedure 5-48
4. The Cross Connect Setting window appears. Click the Service No. to be
modified.
Service No.
5. The Cross Connect Setting (Modify) dialog box appears. Modify the
parameter accordingly.
NWD-107461-04E Operation
System Operation 5-137
8. The Cross Connect Setting window appears again. Confirm the modified
parameters of the cross connect.
Operation NWD-107461-04E
5-138 System Operation
Procedure 5-49
Delete button
5. The Cross Connect Setting (Delete) dialog box appears. Check the
Service No. to be deleted.
NWD-107461-04E Operation
System Operation 5-139
Service No.
6. Click OK button.
9. The Cross Connect Setting window appears again. Confirm that the selected
cross connect has been deleted.
Operation NWD-107461-04E
5-140 System Operation
NWD-107461-04E Operation
System Operation 5-141
Procedure 5-50
Modify button
5. The Equipment Clock Setting dialog box appears. Assign a proper value for
each parameter.
Operation NWD-107461-04E
5-142 System Operation
Figure 5-238 Equipment Clock Setting Dialog Box (with CLK2M-C Card)
Figure 5-239 Equipment Clock Setting Dialog Box (without CLK2M-C Card)
NWD-107461-04E Operation
System Operation 5-143
Operation NWD-107461-04E
5-144 System Operation
8. The Equipment Clock Setting window appears again. Confirm the displayed
parameters.
Procedure 5-51
NWD-107461-04E Operation
System Operation 5-145
Modify button
5. The Ext Clock Setting dialog box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-146 System Operation
Note: You can not change the Port/CH parameters when the same interface is
already registered on the Equipment clock setting.
8. The Ext Clock Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-147
Selecting the input of SC Channel, RS-232C, and V.11 from the SC channel of
each MODEM
• OW Setting
Setting the OW channel of the radio section and CALL OUT polarity
Operation NWD-107461-04E
5-148 System Operation
(1) SC Setting
Procedure 5-52
SC Channel
5. The V.11/SC Setting (SC Channel) dialog box appears. Specify the proper
SC channel for each interface.
NWD-107461-04E Operation
System Operation 5-149
Figure 5-247 V.11/SC Setting (SC Channel) Dialog Box (for MODEM1)
Figure 5-248 V.11/SC Setting (SC Channel) Dialog Box (for STM1-S)
Operation NWD-107461-04E
5-150 System Operation
(2) MODEM
Procedure 5-53
NWD-107461-04E Operation
System Operation 5-151
5. The V.11/SC Setting dialog box appears. Specify the proper SC channel for
each interface.
Figure 5-252 V.11/SC Setting Dialog Box (between MODEM1 and MODEM2)
Operation NWD-107461-04E
5-152 System Operation
Figure 5-253 V.11/SC Setting Dialog Box (between MODEM1 or MODEM2 to STM1-S)
NWD-107461-04E Operation
System Operation 5-153
(3) STM1-S
Procedure 5-54
Operation NWD-107461-04E
5-154 System Operation
5. The V.11/SC Setting dialog box appears. Specify the proper SC channel for
each interface.
NWD-107461-04E Operation
System Operation 5-155
Procedure 5-55
3. Select V.11 Directional Setting from the V.11/OW Setting sub menu.
Operation NWD-107461-04E
5-156 System Operation
5. The V.11 Directional Setting dialog box appears. Assign a proper value for
each parameter.
NWD-107461-04E Operation
System Operation 5-157
8. The V.11 Directional Setting window appears again. Confirm the displayed
parameters.
5.1.5.3 OW Setting
Procedure 5-56
Operation NWD-107461-04E
5-158 System Operation
NWD-107461-04E Operation
System Operation 5-159
(2) AUX-S
Procedure 5-57
AUX-S
5. The OW Setting (AUX-S) dialog box appears. Specify a proper value for the
parameter.
Operation NWD-107461-04E
5-160 System Operation
• Correlation Setting
User can specify the alarm severity among critical, major, and minor, and
warning for each alarm reported by iPASOLINK.
NWD-107461-04E Operation
System Operation 5-161
• AIS Setting
User can enable or disable sending of AIS alarm and specify the conditions and
delay of sending AIS alarm.
• BER Threshold
Procedure 5-58
Modify button
5. The Correlation Setting dialog box appears. Assign a proper value for each
parameter.
Operation NWD-107461-04E
5-162 System Operation
Procedure 5-59
4. The Alarm Severity Setting window appears. Click the MODEM tab.
NWD-107461-04E Operation
System Operation 5-163
Modify button
7. Select the desired alarm status from the drop down list of Alarm Status.
Operation NWD-107461-04E
5-164 System Operation
8. Set the alarm status for each Alarm Item, and then repeat the procedures for
other tabs.
NWD-107461-04E Operation
System Operation 5-165
Procedure 5-60
Modify button
5. The AIS Setting dialog box appears. Specify a proper value for each parameter.
Operation NWD-107461-04E
5-166 System Operation
8. The AIS Setting window appears again. Confirm the displayed parameters.
NWD-107461-04E Operation
System Operation 5-167
Procedure 5-61
3. Select BER Threshold Setting from the Alarm/AIS Setting sub menu.
4. The BER Threshold Setting window appears. Click the desired MODEM No.
(or SW GRP1) to configure.
MODEM No.
Operation NWD-107461-04E
5-168 System Operation
8. The BER Threshold Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-169
(2) STM1-S
Procedure 5-62
3. Select BER Threshold Setting from the Alarm/AIS Setting sub menu.
STM-1S
5. The BER Threshold Setting (STM1-S) dialog box appears. Assign a proper
value for each parameter.
Operation NWD-107461-04E
5-170 System Operation
8. The BER Threshold Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
System Operation 5-171
• PMON Other
• RMON Other
Procedure 5-63
4. The PMON Threshold Setting window appears. Select the Main Board tab.
Operation NWD-107461-04E
5-172 System Operation
Modify button
6. The Main Board dialog box appears. Assign a proper value for each parameter.
NWD-107461-04E Operation
System Operation 5-173
Operation NWD-107461-04E
5-174 System Operation
9. The Main Board tab appears again. Confirm the displayed parameters.
Procedure 5-64
NWD-107461-04E Operation
System Operation 5-175
Modify button
Operation NWD-107461-04E
5-176 System Operation
NWD-107461-04E Operation
System Operation 5-177
parameters.
Procedure 5-65
4. The PMON Threshold Setting window appears. Select the STM1-S tab.
Operation NWD-107461-04E
5-178 System Operation
NWD-107461-04E Operation
System Operation 5-179
Operation NWD-107461-04E
5-180 System Operation
NWD-107461-04E Operation
System Operation 5-181
Procedure 5-66
Operation NWD-107461-04E
5-182 System Operation
5. The PMON Other Setting dialog box appears. Assign a proper value for each
parameter.
8. The PMON Other window appears again. Confirm the displayed parameters.
NWD-107461-04E Operation
System Operation 5-183
Procedure 5-67
3. Select RMON Threshold Setting from the PMON/RMON Setting sub menu.
5. The RMON Threshold Setting dialog box appears. Assign a proper value for
each parameter.
Operation NWD-107461-04E
5-184 System Operation
NWD-107461-04E Operation
System Operation 5-185
8. The RMON Threshold Setting window appears again. Confirm the displayed
parameters.
Procedure 5-68
Operation NWD-107461-04E
5-186 System Operation
4. The RMON Other window appears. Click VLAN counter No. in the VLAN
Counter Select tab.
5. The VLAN Counter Select dialog box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-187
8. The RMON Other window appears again. Confirm the displayed parameters.
Operation NWD-107461-04E
5-188 System Operation
Procedure 5-69
4. The RMON Other window appears. Click Delete VLAN Counter button.
5. The Delete VLAN Counter dialog box appears. Select the VLAN Counter
No. to be deleted.
NWD-107461-04E Operation
System Operation 5-189
9. The RMON Other window appears again. Confirm the displayed parameters.
Operation NWD-107461-04E
5-190 System Operation
Procedure 5-70
3. Select AUX Input Setting from the AUX Setting sub menu.
4. The AUX Input Setting window appears. Click Modify button in the desired
AUX tab.
Modify button
5. The AUX Input Setting dialog box appears. Assign a proper value for each
parameter.
NWD-107461-04E Operation
System Operation 5-191
Operation NWD-107461-04E
5-192 System Operation
8. The AUX Input Setting window appears again. Confirm the displayed
parameters.
Procedure 5-71
3. Select AUX Output Setting from the AUX Output Setting sub menu.
4. The AUX Output Setting window appears. Click the desired output No.
NWD-107461-04E Operation
System Operation 5-193
Output No.
5. The AUX Output Setting dialog box appears. Specify a proper value for the
parameters.
Operation NWD-107461-04E
5-194/END System Operation
8. The AUX Output Setting window appears again. Confirm the displayed
parameters.
NWD-107461-04E Operation
Abbreviations 6-1
6. ABBREVIATIONS
Operation NWD-107461-04E
6-2 Abbreviations
NWD-107461-04E Operation
Abbreviations 6-3
Operation NWD-107461-04E
6-4 Abbreviations
NWD-107461-04E Operation
Abbreviations 6-5
Operation NWD-107461-04E
6-6/END Abbreviations
NWD-107461-04E Operation