This document provides an overview and instructions for configuring and using an iPASOLINK 100/200 system. It describes the system components, interfaces, and performance specifications. It also provides directions for logging into the system interface called WebLCT, navigating the main window, and performing user and security management settings. The user management section allows for creating, editing, and deleting user accounts and groups with different access levels.

Uploaded by

Varfee Sarnor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views356 pages

Section Ii Operation: iPASOLINK 100/200

This document provides an overview and instructions for configuring and using an iPASOLINK 100/200 system. It describes the system components, interfaces, and performance specifications. It also provides directions for logging into the system interface called WebLCT, navigating the main window, and performing user and security management settings. The user management section allows for creating, editing, and deleting user accounts and groups with different access levels.

Uploaded by

Varfee Sarnor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 356

-1-

iPASOLINK 100/200
SECTION II OPERATION

CONTENTS

DOCUMENT WARRANTY.....................................................................................................- 5 -
1. Getting Started .............................................................................................................1-1
1.1 Conventions Used in This Manual .......................................................................................... 1-1
1.2 LCT Communication Interface ................................................................................................ 1-1
1.2.1 Communications.............................................................................................................. 1-1
1.2.2 Local Port Interface ......................................................................................................... 1-2
1.3 Equipment Configuration of iPASOLINK................................................................................. 1-2
2. Installation of LCT .......................................................................................................2-1
2.1 Hardware Requirements......................................................................................................... 2-1
2.2 Software Requirements .......................................................................................................... 2-2
2.3 OS Environment for Windows................................................................................................. 2-2
2.3.1 Internet Explorer.............................................................................................................. 2-2
2.3.2 Confirming and Setting TCP/IP ....................................................................................... 2-3
2.4 Recommended browser settings ............................................................................................ 2-4
2.4.1 Internet Explorer 8........................................................................................................... 2-4
2.4.2 Firefox 3.6.x..................................................................................................................... 2-7
3. System Configuration .................................................................................................3-1
3.1 General................................................................................................................................... 3-1
3.2 System Configuration ............................................................................................................. 3-2
3.3 System Overview.................................................................................................................... 3-4
3.3.1 IDU Block Diagram .......................................................................................................... 3-5
3.3.2 ODU Block Diagram ........................................................................................................ 3-5
3.4 Interfaces ................................................................................................................................ 3-6
3.4.1 Baseband Interface ......................................................................................................... 3-6
3.4.1.1 E1 Interface............................................................................................................ 3-6
3.4.1.2 LAN (FE) Interface ................................................................................................. 3-6
3.4.1.3 LAN (GbE) interface............................................................................................... 3-7
3.4.2 LCT /NMS Interface......................................................................................................... 3-7
3.4.2.1 LCT Interface ......................................................................................................... 3-7
3.4.2.2 NMS Interface ........................................................................................................ 3-7

Operation NWD-107461-04E
September, 2011
-2-

3.4.3 ODU Interface ................................................................................................................. 3-7


3.4.3.1 ODU Interface ........................................................................................................ 3-7
3.4.4 Other Interfaces............................................................................................................... 3-8
3.4.4.1 ALM/SC/CLK Interface........................................................................................... 3-8
3.4.4.2 USB Memory Interface........................................................................................... 3-8
3.4.5 Additional Interface.......................................................................................................... 3-8
3.4.5.1 E1 Interface (for Optional Card Slot)...................................................................... 3-8
3.4.5.2 STM-1 Optical Interface (for Optional Card Slot) ................................................... 3-8
3.4.5.3 STM-1 Electrical Interface (for Optional Card Slot) ................................................ 3-8
3.4.6 AUX Card ........................................................................................................................ 3-9
3.4.7 Power Line Inlet (for Power Supply Slot) ......................................................................... 3-9
3.5 IDU (Indoor Unit) and System performance.......................................................................... 3-10
3.5.1 General.......................................................................................................................... 3-10
3.5.2 IDU performances ......................................................................................................... 3-10
4. NE Setup .......................................................................................................................4-1
4.1 Login/Logout/Exit .................................................................................................................... 4-1
4.1.1 Login NE.......................................................................................................................... 4-1
4.1.2 Logout NE ....................................................................................................................... 4-3
4.1.3 Exit WebLCT ................................................................................................................... 4-4
4.2 WebLCT Main Window ........................................................................................................... 4-5
4.3 User Management (Security Managements) .......................................................................... 4-8
4.3.1 User Access Levels ......................................................................................................... 4-9
4.3.2 Default User Account .................................................................................................... 4-12
4.3.3 User Account................................................................................................................. 4-12
4.3.3.1 Login User List ..................................................................................................... 4-13
4.3.3.2 User Account Management.................................................................................. 4-13
4.3.3.3 User Group Profile Configuration ......................................................................... 4-26
4.3.4 Security Management ................................................................................................... 4-33
4.3.4.1 Service Status Setting.......................................................................................... 4-41
4.3.4.2 SNMP .................................................................................................................. 4-43
4.3.4.3 SNMP Community ............................................................................................... 4-46
4.3.4.4 SNMP Trap Entry................................................................................................. 4-52
4.3.4.5 NTP...................................................................................................................... 4-60
4.3.4.6 NTP Server Address ............................................................................................ 4-63
4.3.4.7 FTP ...................................................................................................................... 4-69
4.3.4.8 HTTP ................................................................................................................... 4-72
4.4 Register NE Configuration .................................................................................................... 4-75
4.4.1 Easy Setup Wizard........................................................................................................ 4-75
4.4.1.1 Easy Setup........................................................................................................... 4-75
4.4.1.2 MODEM Setup..................................................................................................... 4-81
4.4.1.3 Management Setup.............................................................................................. 4-84

NWD-107461-04E Operation
-3-

4.4.1.4 TDM Setup........................................................................................................... 4-85


4.4.1.5 ETH Setup ........................................................................................................... 4-87
4.4.2 Equipment Setup........................................................................................................... 4-92
4.4.2.1 Equipment Configuration ..................................................................................... 4-93
4.4.2.2 Radio Configuration ............................................................................................. 4-98
4.4.2.3 AMR Configuration............................................................................................. 4-103
4.4.2.4 Network Management Configuration.................................................................. 4-108
5. System Operation ........................................................................................................5-1
5.1 Provisioning ............................................................................................................................ 5-1
5.1.1 MODEM Function Setting................................................................................................ 5-2
5.1.1.1 MODEM Port Setting ............................................................................................. 5-2
5.1.1.2 Radio Switch Setting.............................................................................................. 5-4
5.1.1.3 TX Power Setting ................................................................................................... 5-7
5.1.1.4 ALM Mode Setting ............................................................................................... 5-11
5.1.1.5 XPIC Setting (iPASOLINK 200) ........................................................................... 5-13
5.1.2 ETH Function Setting .................................................................................................... 5-15
5.1.2.1 Bridge Setting ...................................................................................................... 5-16
5.1.2.2 ETH Port Setting .................................................................................................. 5-18
5.1.2.3 VLAN Setting ....................................................................................................... 5-21
5.1.2.4 FDB Setting.......................................................................................................... 5-32
5.1.2.5 ETH OAM Setting ................................................................................................ 5-43
5.1.2.6 RSTP Setting ....................................................................................................... 5-66
5.1.2.7 QoS/Classification Setting.................................................................................... 5-72
5.1.2.8 Other ETH Port Setting ...................................................................................... 5-100
5.1.2.9 LLF Setting......................................................................................................... 5-102
5.1.2.10 Broadcast Storm Control Rate Setting ............................................................... 5-109
5.1.3 Cross Connect Setting ................................................................................................ 5-112
5.1.3.1 E1 Port Setting................................................................................................... 5-112
5.1.3.2 STM-1 Port Setting ............................................................................................ 5-116
5.1.3.3 Cross Connect Setting ....................................................................................... 5-119
5.1.4 Equipment Clock / Synchronization Setting................................................................. 5-132
5.1.4.1 Equipment Clock Setting.................................................................................... 5-133
5.1.4.2 EXT Clock Setting.............................................................................................. 5-136
5.1.5 V.11/OW Setting.......................................................................................................... 5-139
5.1.5.1 V.11/SC Setting ................................................................................................. 5-140
5.1.5.2 V.11 Directional Setting ..................................................................................... 5-147
5.1.5.3 OW Setting......................................................................................................... 5-149
5.1.6 Alarm/AIS Setting ........................................................................................................ 5-152
5.1.6.1 Correlation Setting ............................................................................................. 5-153
5.1.6.2 AIS Setting ......................................................................................................... 5-154
5.1.6.3 BER Threshold Setting ...................................................................................... 5-157

Operation NWD-107461-04E
-4-

5.1.6.4 BER Threshold Setting ...................................................................................... 5-159


5.1.7 PMON/RMON Setting ................................................................................................. 5-163
5.1.7.1 PMON Threshold Setting ................................................................................... 5-163
5.1.7.2 PMON Other ...................................................................................................... 5-173
5.1.7.3 RMON Threshold Setting ................................................................................... 5-175
5.1.7.4 RMON Other ...................................................................................................... 5-177
5.1.8 AUX Setting................................................................................................................. 5-182
5.1.8.1 AUX Input Setting .............................................................................................. 5-182
5.1.8.2 AUX Output Setting............................................................................................ 5-184

6. Abbreviations ...............................................................................................................6-1

NWD-107461-04E Operation
DOCUMENT WARRANTY -5-

DOCUMENT WARRANTY

1. The information contained in this document is subject to change without prior


notice.
2. The LCT screen figures in this manual are only examples. Screens will vary
according to equipment configurations, equipment operation modes, setting
parameters, LCT application program version, etc. Screens contained in this
manual are current at the moment of publishing; however, they may differ
slightly from the actual screens on your LCT.
3. This manual is written on the assumption that you already understand the
restrictions, limitations and precautions necessary to operate the equipment
properly. Refer to the equipment manual for details.

Operation NWD-107461-04E
- 6 -/END DOCUMENT WARRANTY

This page is intentionally left blank.

NWD-107461-04E Operation
Getting Started 1-1

1. GETTING STARTED

1.1 Conventions Used in This Manual


Table 1-1 Conventions Used in This Manual
Style What Represents Example
Italic For manual titles or related document names. Refer to iPASOLiNK Operation
Manual for details.
Bold Items and buttons on the user interface. Item The Overall window
on the computer display. File and directory
names. Menus and items.
Arrow A menu name and then the item. Select System -> Login/Logout
<Item> A command variable where the user must <password>
make the appropriate entry. This is also
commonly used when asking for a password.
Capitalized key Key name on the keyboard. Press Enter key

1.2 LCT Communication Interface

1.2.1 Communications
The local craft terminal is a useful tool to the installation and maintenance.
iPASOLINK supply users GUI environment through WEB browser. Moreover, this
tool supports remote connection.

Operation NWD-107461-04E
1-2/END Getting Started

1.2.2 Local Port Interface


The LCT Port is located on the front of the equipment.

Figure 1-1 LCT Port Interface

Use LAN Cable connected to the LCT Port at the front of equipment.

The LCT port has the following specifications:

• 10/100 BASE-TX / Cable Type: RJ45

1.3 Equipment Configuration of iPASOLINK


The following protection is available on a single IDU:

Non-protected (1+0), Protected (1+1) with hot standby / space diversity / twin path
with hitless switch, Back-to-back configuration ((1+0) x 2)

NWD-107461-04E Operation
Installation of LCT 2-1

2. INSTALLATION OF LCT

2.1 Hardware Requirements


* Windows XP
Item Required Recommend
CPU Pentium M 1.6 GHz
RAM 512 MB
HDD 40 GB
Display Color LCD (1024x768)
LAN Port 10/100BASE-T(X)
USB Port

* Windows Vista
Item Required Recommend
CPU Intel Core2 Duo 1.6 GHz
RAM 1 GB
HDD 40 GB
Display Color LCD (1024x768)
LAN Port 10/100BASE-T(X)
USB Port

* Windows 7
Item Required Recommend
CPU Intel Core2 Duo 1.6 GHz
RAM 1 GB
HDD 40 GB
Display Color LCD (1024x768)
LAN Port 10/100BASE-T(X)
USB Port

Operation NWD-107461-04E
2-2 Installation of LCT

2.2 Software Requirements


OS: Windows XP (English version), Windows Vista (English version), Windows7
(English version)

Browser: IE8, IE7, Firefox3.6 or higher

2.3 OS Environment for Windows


Check if the following configurations have been done on you PC. If not, follow the
procedures to configure your PC.

• Internet explorer is installed

• TCP/IP Protocol settings are set appropriately

2.3.1 Internet Explorer


Confirm the Internet Explorer is installed on the LCT computer.

Select Start -> Program -> Internet Explorer

Figure 2-1 Windows Start Menu Window

NWD-107461-04E Operation
Installation of LCT 2-3

2.3.2 Confirming and Setting TCP/IP


The IP address of the LCT computer will be detected automatically from DHCP
server of NE side.

Setup the IP address to be detected automatically.

1. Log on the Windows OS as Administrator.

2. Select Start -> Settings -> Control Panel from the Start menu of the
Windows.

3. The Control Panel window appears. Double-click the Network


Connections icon in the Control Panel window.

4. The Network Connections window appears. Double-click the Local Area


Connection icon, then click Properties button.

5. The Local Area Connection Properties window appears. Select Internet


Protocol (TCP/IP), then click Properties button.

6. The Internet Protocol (TCP/IP) Properties window appears. Confirm that


the following parameters are set:

• The Obtain an IP address automatically radio button is selected.

• The Obtain DSN server address automatically radio button is selected.

Figure 2-2 Internet Protocol (TCP/IP) Properties Window

Operation NWD-107461-04E
2-4 Installation of LCT

7. Click OK button of Internet Protocol (TCP/IP) Properties window.

8. The Local Area Connection Properties window reappears. Click OK


button of the Local Area Connection Properties window.

9. The Network Connections window reappears. Close this window.

2.4 Recommended browser settings


Below are the recommended settings for the most popular browsers.

2.4.1 Internet Explorer 8


Tabbed browsing option is recommend.

1. Tools -> Internet Options -> General -> Tabs Settings from the Tool Bar menu
of the Internet Explorer 8.

2. The Tabbed browsing setting Properties window appears. Select


Always open pop-ups in a new tab then click OK button.

Figure 2-3 Internet Options Window

NWD-107461-04E Operation
Installation of LCT 2-5

Figure 2-4 Tabbed browsing setting Properties Window

Security Setting recommendation.

1. Tools -> Internet Options -> Security -> Security Level for this zone “Custom
level…” from the Tool Bar menu of the Internet Explorer 8.

2. The Security Settings – Internet Zone Properties window appears. Check


Downloads "Automatic prompting for file downloads": Enable then
click OK button.

Operation NWD-107461-04E
2-6 Installation of LCT

Figure 2-5 Internet Options Window

Figure 2-6 Security Setting Window

NWD-107461-04E Operation
Installation of LCT 2-7

2.4.2 Firefox 3.6.x


1. Tools -> Options from the Tool Bar menu of the Firefox.

2. The General Properties window appears. Select Always ask me where to


save files then click OK button.

Figure 2-7 Options Window

Operation NWD-107461-04E
2-8/END Installation of LCT

This page is intentionally left blank.

NWD-107461-04E Operation
System Configuration 3-1

3. SYSTEM CONFIGURATION

3.1 General
iPASOLINK 100/200 is a basic configuration for nodal application in the wireless
iPASOLINK family and providing up to 440 Mbps with flexible combination of
native TDM and/or native Ethernet transmission and advanced adaptive modulation
scheme operating in 6, 7, 8, 10, 11, 13, 15, 18, 23, 26, 28, 32 or 38 GHz bands.

The iPASOLINK consists of antenna, outdoor unit (ODU) and indoor unit (IDU) like
as PASOLINK series and accedes to very high performance and ultra high reliability
gained through NEC’s rigid TQC activities and vast experience in wired and wireless
communication fields.

A single indoor unit (IDU) of iPASOLINK can accommodate up to two (2)


independent transmission channels. This allows you to configure back-to-back 1+0,
same direction 1+1 twin path, hot standby, diversity.

Operation NWD-107461-04E
3-2 System Configuration

3.2 System Configuration


The system consists of the MDP-400MB-1B Modulator-Demodulator (Indoor Unit
(IDU)) and TRP-( )G-1B/1D Transmitter-Receiver (Outdoor Unit (ODU)), Hybrid
Combiner/Divider and the antenna.

Note: The Combiner/Divider is used in (1+1) single antenna configuration for


antenna direct mount type ODUs.

z IDU with Antenna Direct Connection

z IDU HS/ HS with Antenna Direct Connection

z IDU HS/ Hybrid SD with Antenna Direct Connection

z IDU Twin-path FD with Antenna Direct Connection

NWD-107461-04E Operation
System Configuration 3-3

z IDU HS SD with Antenna Direct Connection

z IDU x2_2way

z 2+0

Operation NWD-107461-04E
3-4 System Configuration

3.3 System Overview


- ODU-IDU separate mount type. The connection line is only one coaxial cable.

- No protection or protection system is available using common ODU and IDU.

- Flexible configuration for ODU and antenna, direct mount / remote mount / 1+0
(non redundant) / 1+1 hot stand-by / 1+1 space diversity / 1+1 frequency diversity
(twin path), 2+0.

- ACCP, ACAP, CCDP and these combined configurations are available.

- 19 inches one rack unit size compact IDU,

> 483 mm (W) x 44 mm (H) x 240 mm (D)

Figure 3-1 IDU Outline

- Small and light weight ODU for easy handling and installation.

Figure 3-2 ODU Type

- Wide temperature range of ODU and IDU

- DC input voltage nominal rating: -48 VDC

> Wider range power rating is optional: +/- 20 to 60 VDC

NWD-107461-04E Operation
System Configuration 3-5

3.3.1 IDU Block Diagram

Figure 3-3 IDU Block Diagram

3.3.2 ODU Block Diagram

Figure 3-4 ODU Block Diagram

Operation NWD-107461-04E
3-6 System Configuration

3.4 Interfaces

Figure 3-5 IDU Interface Layout

3.4.1 Baseband Interface


The iPASOLINK has various interfaces specified by the ITU-T standard and IEEE
standard as listed below:

3.4.1.1 E1 Interface

- Signal rate: 16 x E1 (2.048 Mbps)

- Interface: HDB-3 (ITU-T G.703)

- Impedance: 75 ohms or 120 ohms (selectable)

- Connector: MDR68

3.4.1.2 LAN (FE) Interface

- Type: 10Base-T/100Base-TX (auto or fixed) / RJ-45

- Port number and interface: 2 (default), Max.4 (2xFE interface can be changed
into 4 x 10/100/ 1000Base-T by software key)

- VLAN: Port-based VLAN / Tag-based VLAN / Tunnel VLAN

- QoS: 802.1p CoS / IPv4 Precedence / IPv4 Diffserv/ IPv6 Diffserv

- QoS control: Deficit WRR or SP+3class Deficit WRR

- Bandwidth management: Shaper and Policing per VLAN or Port

- Protection: STP/RSTP (802.1D/w)

NWD-107461-04E Operation
System Configuration 3-7

3.4.1.3 LAN (GbE) interface

- Type: 1000Base-T/SX/LX (auto or fixed) / LC (SFP)

- Port number and interface: 2 (default), Max.4 (2xFE interface can be changed
into 4 x 10/100/ 1000Base-T (RJ-45) by software
key)

- VLAN: Port-based VLAN / Tag-based VLAN / Tunnel VLAN

- QoS: 802.1p CoS / IPv4 Precedence / IPv4 Diffserv / IPv6 Diffserv

- QoS control: Deficit WRR or SP+3class Deficit WRR

- Bandwidth management: Shaper and Policing per VLAN or Port

- Protection: RSTP (802.1w)

3.4.2 LCT /NMS Interface

3.4.2.1 LCT Interface

The local craft terminal is a useful tool to the installation and maintenance.
iPASOLINK supply users GUI environment through WEB browser. Moreover, this
tool supports remote connection.

- Type: 10/100Base-TX / RJ-45

- Port number and interface: 1

3.4.2.2 NMS Interface

This port is used to connect with the NMS server through the network.

- Type: 10/100Base-TX / RJ-45

- Port number and interface: 1

3.4.3 ODU Interface


This is a port used to connect ODU with IDU with the coaxial cable.

3.4.3.1 ODU Interface

- TNC female

Operation NWD-107461-04E
3-8 System Configuration

3.4.4 Other Interfaces

3.4.4.1 ALM/SC/CLK Interface

This port is used for alarm outside connection, and for digital service channels and
external clock signal.

- D-sub high density 44-way female

3.4.4.2 USB Memory Interface

USB memory is useful to store the equipment setting and configuration data. This
information storage is used for equipment replacement and recovery of setting and
configuration.

- USB type 1 female

3.4.5 Additional Interface


The iPASOLINK has optional card slots, AUX slot and power supply line inlet and
can add interfaces as listed below:

3.4.5.1 E1 Interface (for Optional Card Slot)

16 E1 can be added by adding optional E1 card.

- Signal rate: 16 x E1 (2.048Mbps) / MDR68

- Interface: HDB-3 (ITU-T G.703)

- Impedance: 75 ohms or 120 ohms (selectable)

3.4.5.2 STM-1 Optical Interface (for Optional Card Slot)

This card has E1 and STM-1 converter function and has STM-1 optical interface.

- Signal rate: 1 or 2 x 155.52 Mbps

- Interface: S-1.1/L-1.1 (ITU-T G.957)

- Connector: LC

3.4.5.3 STM-1 Electrical Interface (for Optional Card Slot)

This card is the same function as STM-1 optical function and has STM-1 electrical
interface.

- Signal rate: 1 or 2 x 155.52 Mbps

NWD-107461-04E Operation
System Configuration 3-9

- Interface: CMI (ITU-T G.703)

- Connector: IEC 169-29 (1.0/2.3)

3.4.6 AUX Card

This card supports cluster alarms and DI/DO (data-in/ data-out).

- Cluster alarm: Alarm extension and combining.

- DI: Remote input port for external alarms, etc.

- DO: Remote output from EMS controller.

- D-sub high density 44 ways female

3.4.7 Power Line Inlet (for Power Supply Slot)

Additional power line inlet can apply for operation of two independently power lines.

Operation NWD-107461-04E
3-10 System Configuration

3.5 IDU (Indoor Unit) and System performance

3.5.1 General
NO Item IDU
Operation:-5 to +50 deg.C (ETSI EN300019-1-4 class 3.1E),
Humidity: 95% (at 50 deg.C, No condensing)
1 Environmental condition (Workable: -10 to +55 deg.C)
Transportation ETSI EN300019-1-2 class 2.3
Storage ETSI 300019-1-1 class 1.2
2 Power consumption 1+0 1+1
3 IDU without options 45W 45W
4 Option AUX 5W 5W
5 Option 16 E1 5W 5W
6 Option STM-1 5W 5W
7 External clock board 3W
8 Mechanical Dimensions 1+0/ 1+1
9 IDU Size 482(W)x44(H)x240(D) mm, 3kg Approx.
10 EMC Conforms to EN301 489-4
11 Safety Conforms to EN60950-1

3.5.2 IDU performances


NO Item IDU
Channel 14 MHz 28 MHz 56 MHz
7 MHz
Space (13.75MHz)* (27.5 MHz)* (55MHz)*
Transmission
QPSK 14 28 57 114
Capacity**
1 and 16QAM 28 57 114 230
Channel 32QAM 35 71 143 287
Spacing 64QAM 42 85 172 345
(Mbps)
128QAM 49 99 200 402
256 QAM - 114 229 460
* ;Channel separation at 18 GHz band,
** Physical layer maximum throughput at 64 bytes VLAN tagged packet size, -; Not available
16 x E1 (G.703) MDR68 connector
E1
(option: up to total 32x E1 available with additional card)
Main Signal
2 2 x 10/100 Base-T(X) RJ45 connector (option: up to 4x 10/100/1000Base-T available)
Interface LAN
2 x 1000Base-SX or LX with optional SFP modules ( connector type: LC)
STM-1 1x STM-1 (S 1.1 or L 1.1.) with optional card (connector type: LC)

3 Interconnecting Connector, Connector type: TNC female


Cable impedance and Cable
length (IDU-ODU) Cable length: Nominal 300 m maximum with 8D-FB-E or equivalent performance cable

4 Power Line Requirement -48 VDC (-40.5 to -57 VDC), Conforms to EN300 132-2

NWD-107461-04E Operation
System Configuration 3-11

NO Item IDU
Function outline
Native Ethernet and Native
5 MODEM has both native Ethernet and Native TDM signal processing circuit
TDM
QPSK/ 16QAM/ 32QAM/ 64QAM/ 128QAM/ 256QAM :
6 Adaptive modulation (AMR)
6 modulation schemes changeable
7 Radio protection method 1+1 HS/HS,HS/SD,FD(HS: Hot Stand by, SD: Space Diversity, FD: Frequency Diversity
8 E1 Ring protection E1 SNCP support
Switching Capacity 20 Gbps (Non Blocking)
MAC Learning Independent VLAN Learning(VLAN + MAC),
Table Up to 128K (configurable)
Port based, Tag based,
Up to 256 VLAN per equipment,
VLAN
MEF 9 Certified EPL, EVPL and ELAN services support with L2CP
Tunneling function
Jumbo Frame Support (Up to 9600 byte)
MEF/RFC4115 compliant policing
(CIR/EIR/CBS/EBS)
Ingress
QoS Class Classification: VLAN CoS/IPv4 DSCP/IPv6
9 ETH functions DSCP/MPLS EXP/ETH Port
4 Classes SP/D-WRR queues
QoS - per-class rate configurable shaping
- per-class configurable maximum burst length
Egress
- shaping for strict priority queue
Hierarchical shaping (Port and Class)
WRED congestion avoidance and Weighted Tail Drop
ETH OAM 802.1ag Service OAM (CC/LB/LT)
Protection STP/RSTP
SyncE Support
Other Link Loss Forwarding, Mirroring, Broadcast Storm Control
XPIC(CCDP) function
10 QPSK to 256QAM modulation at 14/28/56 MHz channel spacing
support
AMR, 1+1 and XPIC
11 AMR and 1+1, AMR and XPIC combination available
combination
DXC (E1 cross connect ) Up to 152 x 152 E1 non blocking
12
capacity
Clock Source for Equipment
13 E1/STM-1/Modem/SyncE/External Clock
Clock
External clock interface 2.048 MHz or 2.048 Mbps external clock input /output, 75 or 120 ohms selectable,
14
(option) D-sup 44 ways connector
DCN and Service channel outline
1 port, 10/100 Base-T RJ 45 (inband or outband connection available)
15 NMS interface
SNMPv1/v2c/v3
16 NE1 1 port, 10/100 Base-T, RJ 45
17 NE2 (RS485) 1 port, Serial signal port for legacy equipment, RJ 45
18 LCT (Local craft terminal) 1 port, 10/100Base-T, RJ 45, DHCP server support

Operation NWD-107461-04E
3-12/END System Configuration

NO Item IDU
House keeping and cluster
19 Input 6 ch, output 6 ch available with optional AUX card, D-sub 44 ways
alarm
20 Service channel 1 2 ports, RS-232C: 9.6 kbps async, D-sub 44 ways
21 Service channel 2 2 ports, V-11 (co or contra direction selectable) 64 kbps sync, D-sub 44 ways
22 Engineering order wire 1 port 4-wire voice channel, D-sub 44 ways
Far End Baseband Loop Back
23 Loop Back Near End Baseband Loop Back
IF Loop Back
24 Modem TX output Control Manual control, Automatic control (ATPC), Mute control
PMON Items;
a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS
Modem Metering Items
Performance Monitoring
25 a) Output power level (TX PWR), b) Received signal level (AGC V),
(PMON)/Metering
c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error

NWD-107461-04E Operation
NE Setup 4-1

4. NE SETUP

4.1 Login/Logout/Exit

4.1.1 Login NE
Users are registered by means of login name and password. To protect the network
and network management system from unauthorized access or unauthorized
modifications, three levels (refer to the table shown in section 4.3.2 User Account
Management) of users are defined with different privileges. The functions available
in the window depend on the user’s access level. Therefore, some of the functions
may or may not be carried out.

The highest or administrator level (Admin) has full access to the network and
network management system.

Procedure 4-1

1. Power on the computer.

2. Log in the Windows as Administrator.

3. Select Start -> Programs -> Internet Explorer from start menu.

4. The Internet Explorer window appears. Input the IP address of the NE and
WebLCT in URL Address box as shown below.

Ex: http://172.17.254.253/weblct/

Figure 4-1 Internet Explorer Window

Operation NWD-107461-04E
4-2 NE Setup

5. The WebLCT login window appears. Input user name and password in User
Name and Password textbox then press OK.

Figure 4-2 WebLCT Login Window

The following is the default user name and password for iPASOLINK 100/200:

• User Name : Admin

• Password : 12345678

6. The WebLCT main window appears.

Figure 4-3 WebLCT Main Window

NWD-107461-04E Operation
NE Setup 4-3

4.1.2 Logout NE

Procedure 4-2

1. Click Logout button in the right top of the WebLCT main window.

Figure 4-4 WebLCT Main Window

2. The Confirmation box appears. Click OK button to log out.

Figure 4-5 Confirmation Box

3. The WebLCT Login window appears again.

Operation NWD-107461-04E
4-4 NE Setup

Figure 4-6 WebLCT Login Window

This step ends the procedure.

4.1.3 Exit WebLCT


The following shows the methods to exit the WebLCT:

• Select File (F) -> Exit from the Internet Explorer menu bar.

• Click X button in the right top of the Internet Explorer window.

NWD-107461-04E Operation
NE Setup 4-5

4.2 WebLCT Main Window


This section describes the contents and structure of the WebLCT main window.

Figure 4-7 WebLCT Main Window

(1) Login User Name

This part shows the current logged in user name.

(2) Refresh Button

Click Refresh button to update the current status of the WebLCT main
window.

(3) Equipment Status View

This part shows the current equipment status.

(4) Opposite Site Links

This part shows a list of NE on the opposite site, user can select the NE from the

Operation NWD-107461-04E
4-6 NE Setup

pull down list to log in to the specified NE on the opposite site.

(5) Maintenance Button

Click Maintenance button before user performs any maintenance operation.

(6) Logout Button

Click Logout button to log out from NE.

(7) Alarm and Status View

Click the corresponding tab to switch among the different event log view.

(8) Menu Tree

This part shows the tree view of the relevant configuration and provisioning
menu of the equipment.

The available operations via the WebLCT are shown below.

(a) Current Status

Select this menu to show the equipment current status or history events for
each part of the NE (Active Alarm, Event Log, ODU, IDU, AUX).

(b) Easy Setup Wizard

Follow the Easy Setup Wizard to setup the basic configuration of the
equipment. The wizard includes ODU and IDU package registering,
removing function. This wizard provides a easier way to setup cross connect,
VLAN service and other necessary configuration for a new equipment.

(c) Equipment Setup

Select this menu to register or remove ODU and IDU package and other
relevant configuration.

(d) Provisioning

Select this menu to configure the detail settings of the IDU and ODU.

(e) Maintenance Control

Select this menu to operate Protection Switch, Loopback, H/W_F/W Reset,


etc.

NWD-107461-04E Operation
NE Setup 4-7

(f) Maintenance Test

Select this menu to measure the link quality of Ethernet traffic.

(g) Current/History PMON/RMON Report

Select this menu to browse the report of Current, History, PMON and
RMON. User can also export the data to external storage (Local PC, USB
Memory). (For more details, refer to Maintenance Manual)

(h) Metering

Select this menu to measure the real time TX power, RX level, ODU power
supply and BER.

(i) Equipment Utility

Select this menu to upload and download equipment configuration data,


software and firmware and FPGA data.

(j) User Account/Security Setting

Select this menu to add, remove and modify user account of the equipment,
and setup user account security.

(k) Inventory

Select this menu to browse inventory information about the Equipment and
Software License.

(l) S/W License Setup

Select this menu to import S/W License key and set Radio capacity.

Operation NWD-107461-04E
4-8 NE Setup

4.3 User Management (Security Managements)


User management is the function to manage the authorized user access to network
system and prevent unauthorized user from accessing to the network system.

z Access Level

There are three user access levels with different privilege in iPASOLINK as
shown in the following table. For details of available operations of each access
level, refer to Table 4-3 User Access Privilege Levels.

Table 4-1 Access Level


Access Description File Operation SNMP
Level Operation
Operator View configuration and equipment status Upload only Get
Config Operator user level + Management, Radio base band, Upload/Download Get/Set
switching Function
Admin Config user level + Data file update + User Upload/Download Get/Set
management, Time management

Note: About the terms Upload and Download mentioned in the table above,
refer to the following description.
1. Upload means copy the file from NE to external storage, such as WebLCT
PC.
2. Download means copy the file from external storage to the equipment
internal storage.

z User Group

User Group configuration allow user to manage the Protocol Type and Access
Level for each group.

The user that assigned to the specified user group in iPASOLINK will be
assigned with pre-defined protocol and access level of the group.

Beside of the three default user groups, user can add up to six user groups
additionally. The default user groups are shown below.

Note: User can not change the options of default user group.

NWD-107461-04E Operation
NE Setup 4-9

Table 4-2 User Group Profile


Group classification TELNET SSH FTP HTTP SNMP Access
Name Level
OPERATOR Unchangeable ― ― √ √ √ Operator
CONFIG Unchangeable ― ― √ √ √ Config
ADMIN Unchangeable ― ― √ √ √ Admin

4.3.1 User Access Levels


The following describes the details of each access levels. Remote means when user
access to the equipment
R/W: Read and write
R: Read only
O: The functions are available when user accesses to the equipment remotely but
restricted by the assigned access level.

Table 4-3 User Access Privilege Levels


WebLCT Menu Admin Config Operator Remote
Easy Setup Wizard
Easy Setup R/W
MODEM Setup R/W
Management Setup R/W
ETH Setup R/W
TDM Setup R/W
Equipment Setup
Equipment Configuration R/W R R O
Radio Configuration R/W R/W R O
AMR Configuration R/W R/W R O
Network Management General Setting R/W R R O
Configuration General Setting (Detail) R/W R R O
Routing Setting R/W R R O
Provisioning
MODEM Function Setting MODEM Port Setting R/W R/W R O
Radio Switch Setting R/W R/W R O
TX Power Setting R/W R/W R O
ALM Mode Setting R/W R/W R O
BER Threshold Setting R/W R/W R O

Operation NWD-107461-04E
4-10 NE Setup

WebLCT Menu Admin Config Operator Remote


ETH Function Setting Bridge Setting R/W R/W R O
ETH Port Setting R/W R/W R O
VLAN Setting R/W R/W R O
FDB Setting R/W R/W R O
ETH OAM Setting R/W R/W R O
RSTP Setting R/W R/W R O
QoS/Classification Setting R
Filter Setting R/W R/W R O
Other ETH Port Setting R/W R/W R O
LLF Setting R/W R/W R O
Provisioning
E1/STM-1/Cross Connect Cross Connect Setting R/W R/W R O
Setting E1 Port Setting R/W R/W R O
STM-1 Port Setting R/W R/W R O
EXT Clock Setting Equipment Clock Setting R/W R/W R O
EXT Clock Setting R/W R/W R O
Relay-Alarm Mapping Setting Relay Control Setting R/W R/W R O
Cluster Alarm Setting R/W R/W R O
V.11/OW Setting V.11/SC Setting R/W R/W R O
V.11 Directional Setting R/W R/W R O
OW Setting R/W R/W R O
Alarm/AIS Setting Correration/Delay_Strech R/W R/W R O
Setting
Alarm Severity Setting R/W R/W R O
Color Setting R/W R
AIS Setting R/W R/W R O
PMON/RMON Threshold PMON Threshold R/W R/W R O
Setting PMON Other R/W R/W R O
RMON Threshold R/W R/W R O
RMON Other R/W R/W R O
AUX Setting AUX Input Setting R/W R/W R O
AUX Output Setting R/W R/W R O
Maintenance Control
Loopback Control MODEM Loopback Control R/W R/W R
TDM Loopback Control R/W R/W R
(E1 LB1)
TDM Loopback Control R/W R/W R
(E1 LB2)

NWD-107461-04E Operation
NE Setup 4-11

WebLCT Menu Admin Config Operator Remote


TDM Loopback Control R/W R/W R
(STM-1 LB1)
TDM Loopback Control R/W R/W R
(STM-1 LB2)
Protection Control MODEM TX/RX SW R/W R/W R
Control
PSTP Control R/W R
SNCP SW Control R/W R/W R
Timing Source SW Control R/W R/W R
MODEM Maintenance Control R/W R/W R
Auto Laser Shutdown Control R/W R/W R
H/W_F/W Reset Control H/W Reset Control R/W R/W R
F/W Reset Control R/W R/W R
PMON/RMON/FDB Clear R/W R R
Offline Maintenance -
Maintenance Test ETH OAM LB/LT/LM/DM R/W R/W R
Control
Current/History PMON/RMON Report
MODEM PMON Report R
E1 PMON Report R
STM-1 PMON Report R
ETH RMON Report R
VLAN Counter Report R
ETH OAM Counter Report R
Metering
Current Metering R
Equipment Utility
User Account/Security Setting
Login User R/W - -
User Account Management R/W - -
User Group Profile Configuration R/W - -
Security Management Security Status Setting R/W R R
Inventory
Equipment Inventory Information R/W R/W R
S/W License Information R/W R/W R
S/W License Setup
Import License Key R/W R
Radio Capacity Setting R/W R

Operation NWD-107461-04E
4-12 NE Setup

4.3.2 Default User Account


There are three default user accounts in iPASOLINK with the pre-defined access
level and privileges. User can add up to nine user accounts additionally.

Following describes the details of the default user account.

Table 4-4 Default User Account


User Default Password Description Default Group
Name
User 87654321 User is able to confirm system configuration and equipment OPERATOR
status. It is not available to make any configuration change.
Config 87654321 Beside of the function can be performed by User, Config CONFIG
user is able to do radio management, baseband
management, Switching function management for C-Plane
control.
Admin 12345678 Beside of the function can be performed by Config user, ADMIN
Admin user is able to do database management, file
management, user management and time management for
M-Plane control.

4.3.3 User Account


The following User Management Functions are available on iPASOLINK.

• Login User List


Display the information of registered User Account in iPASOLINK and modify
User profiles such as password and User Group Profile.

• User Account Management


Register new user account, modify and delete exist user account.

• User Group Profile Configuration


Register new user group, modify and delete exist user group.

NWD-107461-04E Operation
NE Setup 4-13

4.3.3.1 Login User List

This function is for confirming the existing user account in iPASOLINK.

Procedure 4-3

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select Login User List from the User Account/Security Setting sub
menu.

3. The Login User List window appears.

Figure 4-8 Login User List Window

This step ends the procedure.

4.3.3.2 User Account Management

This function is for registering new user accounts, modifying and deleting existing
user account in iPASOLINK.

Note: This function is available for Admin access level user only.

z Add User Account

This function is for registering the new user account other than the existing user
account.

Note: Up to nine user accounts can be added beside of the three default user
accounts.

Operation NWD-107461-04E
4-14 NE Setup

z Modify User Account

This function is for modifying existing user account information including


password and user group.

z Delete User Account

This function is for deleting existing user account.

(1) Add User Account

Note: Security Level (hash Algorithm / Priv (Privacy) Algorithm) is required to


be set when registering new user account. It is impossible to modify it
after a user account has been registered.

Procedure 4-4

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select User Account Management from the User Account/Security


Setting sub menu.

3. The User Account Management window appears. Click Add User button.

Add User button

Figure 4-9 User Account Management Window

4. The User Setting dialog box appears. Enter the proper value for each
parameter.

NWD-107461-04E Operation
NE Setup 4-15

Figure 4-10 User Setting Dialog Box

Table 4-5 Add User Account


Item Parameter
User Name 1 to 31 characters
Password 8 to 31 characters
Group ADMIN/CONFIG/OPERATOR or GROUP added
(For more details refer to 4.3.3.3 User Group Profile
Management)
Security NoAuthNoPriv User login without authentication and encryption.
Level AuthNoPriv User login need authentication (MD5 or SHA1
based) but without encrypted.
AuthPriv User login need authentication (MD5 or SHA1
based) and the data is encrypted by DES or AES.
Auth Algorithm Select Authentication Algorithm between MD5 and
SHA
(For more details refer to (b) in case AuthNoPriv is
selected)
Auth Key Input 8 to 16 digits Public key of MD5 or SHA1
Priv Algorithm Select the encryption method between DES/ AES
(For more details refer to following (c) in case of
AuthPriv is selected)
Priv Key Input 8 to 16 digits key of DES or AES

Operation NWD-107461-04E
4-16 NE Setup

5. Click Set Password in the User Setting dialog box. The Set Password
box appears. Enter the same password into New Password and Re-Enter
boxes and then click OK button.

Figure 4-11 Set PassWord Box

6. The User Setting dialog box appears again. Click OK button to close the
dialog box.

Figure 4-12 User Setting Dialog Box

7. Select the security level.

Note: Selection of Auth / Priv Algorithm will change according to the security
level below.

NWD-107461-04E Operation
NE Setup 4-17

Table 4-6 Security Level Parameter


Item Parameter
Security NoAuthNoPriv User login without authentication and encryption.
Level AuthNoPriv User login need authentication (MD5 or SHA1
based) but without encrypted.
AuthPriv User login need authentication (MD5 or SHA1
based) and the data is encrypted by DES or AES.
Auth Algorithm Select Authentication Algorithm between MD5 and
SHA
(For more details refer to (b) below in case
AuthNoPriv is selected)
Auth Key Input 8 to 16 digits Public key of MD5 or SHA1
Priv Algorithm Select the encryption method between DES/ AES
(For more details refer to (c) below in case AuthPriv
is selected)
Priv Key Input 8 to 16 digits key of DES or AES

z Security Level

(a) For NoAuthNoPriv

For NoAuthNoPriv, Auth Algorithm and Private Algorithm are not


selectable.

Figure 4-13 User Setting (NoAuthNoPriv) Box

Operation NWD-107461-04E
4-18 NE Setup

(b) For AuthNoPriv

For AuthNoPriv, Auth Algorithm and Auth Key are selectable.

Figure 4-14 User Setting (AuthNoPriv) Box

Table 4-7 Auth Algorithm


Auth Algorithm Type Description
MD5 One of the Hash Algorithm for authentication and digital signature. In
order to detect the falsification of Original data during the data
transmitting, Original data will be converting the Hash by comparing
at both ends.
SHA One of the Hash Algorithm for authentication and digital signature. In
order to detect the falsification of Original data during the data
64
transmitting, Less than 2 bits of original data will be converting the
Hash of 160 bits by comparing at both ends.

Figure 4-15 Set Auth Key Box

NWD-107461-04E Operation
NE Setup 4-19

Figure 4-16 User Setting (AuthNoPriv) Box

(c) For AuthPriv

For AuthPriv, Auth Algorithm, Auth key and Pri Algorithm Priv Key are
selectable.

Figure 4-17 User Setting (AuthPriv) Box

Operation NWD-107461-04E
4-20 NE Setup

Table 4-8 Privacy Algorithm


Privacy Algorithm Description
Type
DES DES is 56 bits encryption key and encryption by 64
bit block.
AES SPN structured block encryption, block length is 128
bits, and the length of key is 128 / 192 / 256 bits.

Figure 4-18 Set Priv Key Box

Figure 4-19 User Setting (AuthPriv) Box

8. Click OK button after specifying the proper value for each parameter.

9. The Information box appears. Click OK button.

NWD-107461-04E Operation
NE Setup 4-21

Figure 4-20 Information Box

10. The User Account Management window appears again. Confirm the user
account information displayed.

Figure 4-21 User Account Management Window

This step ends the procedure.

(2) Modify User Account

Procedure 4-5

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select User Account Management from the User Account/Security


Setting sub menu.

3. The User Account Management window appears. Click the desired user
account.

Operation NWD-107461-04E
4-22 NE Setup

User Account

Figure 4-22 User Account Management Window

4. The User Setting box appears. Specify the proper value of each parameter.

Figure 4-23 User Setting Box

• Select the user group from Group Name dropdown list to change the user
group of the user.

• Click Set Password on the top of the User Setting box to change the current
password. Enter the new password into New Password and Re-Enter on the
Set PassWord box.

NWD-107461-04E Operation
NE Setup 4-23

Figure 4-24 Set PassWord Box

5. The User Setting dialog box appears again. Click OK button after inputting all
the information.

Figure 4-25 User Setting Box

6. The Information box appears. Click Ok button.

Figure 4-26 Information Box

Operation NWD-107461-04E
4-24 NE Setup

7. The User Account Management window appears again. Confirm the


modified user account information displayed.

Figure 4-27 User Account Management Window

This step ends the procedure.

(3) Delete User Account

Procedure 4-6

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select User Account Management from the User Account/Security


Setting sub menu.

3. Click Delete User button on the User Account Management window.

Delete User button

Figure 4-28 User Account Management Window

NWD-107461-04E Operation
NE Setup 4-25

4. The User Setting box appears. Select the user account from drop-down list and
click OK button.

Figure 4-29 User Setting Box

5. The Confirmation box appears. Confirm the user name being deleted and then
click OK button.

Figure 4-30 Confirmation Box

6. The Information box appears. Click OK button.

Figure 4-31 Information Box

Operation NWD-107461-04E
4-26 NE Setup

7. The User Account Management window appears again. Confirm that the
user has been deleted.

Figure 4-32 User Account Management Window

This step ends the procedure.

4.3.3.3 User Group Profile Configuration

This setting is for registering and modifying the user group profiles.

The privilege of iPASOLINK user is subject to change according to the assigned user
access level and protocols that specified in the User Group Profile.

Only Admin level user is able to configure the settings.

z Add User Group Profile

This function is for registering the new User Group Profile other than the default
User Group Profile.

Note: Up to six User Group Profiles can be registered beside of the three default
User Group Profiles.

z Modify User Group Profile

This function is for modifying the existing User Group Profile (Access Level and
Protocol).

z Delete User Group Profile

This function is for deleting the existing User Group Profile.

NWD-107461-04E Operation
NE Setup 4-27

(1) Add User Group

Procedure 4-7

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select User Group Profile Configuration from the User


Account/Security Setting sub menu.

3. Click Add Group on the top of the User Group Profile Configuration
window.
Add Group button

Figure 4-33 User Group Profile Configuration Window

4. The Group Setting box appears. Specify the proper value for each parameter
and the click OK button.

Figure 4-34 Group Setting Box

Operation NWD-107461-04E
4-28 NE Setup

Table 4-9 User Group Profile Configuration


Parameter Description
Group Name 1 to 32 characters
FTP Allow or deny using FTP Protocol to transmit Files.
HTTP Allow or Deny using HTTP Protocol for WebLCT to access
equipment.
SNMP Allow or Deny using SNMP Protocol to access to network
equipment.
Access Level Specify the user access level (Admin/Config/Operator)
(For more details refer to Table 4-3 User Access Privilege Levels)

5. The Information box appears. Click OK button.

Figure 4-35 Information Box

6. The User Group Profile Configuration window appears again. Confirm


newly added User Group Profile information displayed.

Figure 4-36 User Group Profile Configuration Window

This step ends the procedure.

NWD-107461-04E Operation
NE Setup 4-29

(2) Modify User Group

Procedure 4-8

1. Expand User Account/Security Setting from the WebLCT menu.

2. Select User Group Profile Configuration from the User


Account/Security Setting sub menu.

3. The User Group Profile Configuration window appears. Click the desired
Group Name.

Group Name

Figure 4-37 User Group Profile Configuration Window

4. The Group Setting box appears. Modify the parameters accordingly and then
click OK button.

Figure 4-38 Group Setting Box

Operation NWD-107461-04E
4-30 NE Setup

• Click either Allow or Deny radio button of the corresponding protocol to


change the setting.

• Select the proper Access Level from drop-down list to change the access level of
the user group.

5. Click OK button after completing the modification.

6. The Information box appears. Click OK button.

Figure 4-39 Information Box

7. The User Group Profile Configuration window appears again. Confirm the
user group profile information displayed.

Figure 4-40 User Group Profile Configuration Window

This step ends the procedure.

(3) Delete User Group

Note: A user group can be deleted only when no user account has been
assigned to the user group.

Procedure 4-9

1. Expand User Account/Security Setting from the WebLCT menu.

NWD-107461-04E Operation
NE Setup 4-31

2. Select User Group Profile Configuration from the User


Account/Security Setting sub menu.

3. The User Group Profile Configuration window appears. Click Delete


Group button.

Delete Group button

Figure 4-41 User Group Profile Configuration Window

4. The Group Setting box appears. Select the Group profile name from the
drop-down list.

Figure 4-42 Group Setting Box

5. The Confirmation box appears. Confirm that the User Group name is deleted
and then click OK button.

Figure 4-43 Confirmation Box

Operation NWD-107461-04E
4-32 NE Setup

6. The Information box appears. Click OK button.

Figure 4-44 Information Box

7. The User Group Profile Configuration window appears again. Confirm the
User Group Profile information displayed.

Figure 4-45 User Group Profile Configuration Window

This step ends the procedure.

NWD-107461-04E Operation
NE Setup 4-33

4.3.4 Security Management


iPASOLINK supports the following Protocol and Security Management functions.

(1) SNMPv1 (Simple Network Management Protocol Version 1)

SNMPv1 is a communication protocol to monitor/control the network equipment


on IP network and specified by flowing RFC.

Table 4-10 RFC Standard


RFC No. Title
RFC 1155 Structure and Identification of Management Information on
TCP/IP-based Internets (SMIv1)
RFC 1157 A Simple Network Management Protocol (SNMP)
RFC 1213 Management Information Base on Network Management of
TCP/IP-based internets: MIB-II

iPASOLINK mounts SNMPv1 to provide the following functions:

- GET/SET of MIB

Responds the request of PDU (Protocol Data Unit) supported by SNMPv1.

Up to ten SNMP managers including the setting of IP address, community name,


security settings, etc. can be registered via the WebLCT.

By default iPASOLINK uses the port 161 to receive the SNMP request UDP. If
user wants to use the pot other than the default one, it can be changed via the
WebLCT.

Table 4-11 Supported PDU by SNMPv1


Item Description
GetRequest Requests the specified instance value.
GetNextRequest Requests the subsequent instance value of specified instance
value in the list.
GetResponse Responds to the corresponding GetRequest and SetReaquest.
SetRequest Sets the specified instance value.
Trap Informs the change of sate and troubles (SNMPv1-Trap).

Operation NWD-107461-04E
4-34 NE Setup

- Send Trap

iPASOLINK can send SNMPv1 trap activity to UDP port 162, and up to three
destination IP addresses can be registered in advance. User also can specify the
community name and PDU type.

- User Application (Log)

iPASOLINK records the accessed user name in the log file.

(2) SNMPv2c (Simple Network Management Protocol Version 2c)

SNMPv2c is a communication protocol to monitor/control the network


equipment on IP network, the difference from SNMPv1 is the availability to add
GetBulk, inform request, unified packet format of each PDU, using SMIv2 and
specified by flowing RFC for SMIv2 use by SNMPv2c.

Table 4-12 RFC Standard


RFC No. Title
SNMPv2c
RFC 1901 Introduction to Community-based SNMPv2
RFC 3416 Version 2 of the Protocol Operations for the Simple Network
Management Protocol (SNMP)
RFC 3417 Transport Mappings for the Simple Network Management
Protocol (SNMP)
RFC 3418 Management Information Base (MIB) for the Simple Network
Management Protocol (SNMP)
RFC 3584 Coexistence between Version 1, Version 2, and Version 3 of the
Internet-standard Network Management Framework
SMIv2
RFC 2578 Structure of Management Information Version 2 (SMIv2)
RFC 2579 Textual Conventions for SMIv2
RFC 2580 Conformance Statements for SMIv2

NWD-107461-04E Operation
NE Setup 4-35

iPASOLINK mounts SNMPv2c to provide the following functions:

- GET/SET of MIB

iPASOLINK responds to the request of the network management system.

Up to ten SNMP managers including the setting of IP address, community name,


security settings, etc. can be registered via the WebLCT.

By default iPASOLINK uses the port 161 to receive the SNMP request UDP. If
user wants to use the pot other than the default one, it can be changed via the
WebLCT.

Table 4-13 Supported PDU by SNMPv2c


Item Description
GetRequest Requests the specified instance value.
GetNextRequest Requests the subsequent instance value of specified
instance value in the list.
GetResponse Responds to the corresponding GetRequest and
SetRequest.
SetRequest Sets the specified instance value.
SNMPv2-Trap Informs the change of sate and troubles.
The same trap is used as in SNMPv1, and the only
difference is the format of PDU.
GetBulkRequest Requests a number of instance value.
InformRequest Informs the event.

- Send Trap

iPASOLINK can send SNMPv2 trap activity to UDP port 162, and up to three
destination IP addresses can be registered in advance. User also can specify the
community name and PDU type.

- User Application (Log)

iPASOLINK records the accessed user name in the log file.

(3) SNMPv3 (Simple Network Management Protocol: Version 3)

SNMPv3 is a communication protocol to monitor/control the network equipment


on IP network, the difference between SNMPv1/ v2c are available to use user
authentication, cipher communication, change packet format and specified by
flowing RFC for SMIv2 use by SNMPv3, SNMPv2c.

Operation NWD-107461-04E
4-36 NE Setup

Table 4-14 RFC Standard


RFC No. Title
SNMPv2c
RFC 3411 An Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks
RFC 3412 Message Processing and Dispatching for the Simple Network
Management Protocol (SNMP)
RFC 3413 Simple Network Management Protocol (SNMP) Applications
RFC 3414 User-based Security Model (USM) for version 3 of the Simple
Network Management Protocol (SNMPv3)
RFC 3415 View-based Access Control Model (VACM) for the Simple
Network Management Protocol (SNMP)
RFC 3416 Version 2 of the Protocol Operations for the Simple Network
Management Protocol (SNMP)
RFC 3417 Trans port Mappings for the Simple Network Management
Protocol (SNMP)
RFC 3418 Management Information Base (MIB) for the Simple Network
Management Protocol (SNMP)
RFC 3584 Coexistence between Version 1, Version 2, and Version 3 of the
Internet-standard Network Management Framework
SMIv2
RFC 2578 Structure of Management Information Version 2 (SMIv2)
RFC 2579 Textual Conventions for SMIv2
RFC 2580 Conformance Statements for SMIv2

NWD-107461-04E Operation
NE Setup 4-37

iPASOLINK mount SNMPv3 to provide following function:

- GET/SET of MIB

Response the request of PDU (Protocol Data Unit) that correspond by SNMPv3

Table 4-15 Corresponding PDU for SNMPv3


Item Description
GetRequest Required the specified instance value
GetNextRequest Required the subsequent instance value of specified
instance value in the list.
GetResponse Response for requirement.
SetRequest Setting the specified instance value.
SNMPv3-Trap Inform the change of sate and troubles.
Same trap using among SNMPv1, SNMPv2, SNMPv3
only difference is format of PDU.
GetBulkRequest Required a number of instance value.
InformRequest Inform the event.
Report Response the packet if reportableFlag turns on. .

- Send Trap

Available to send SNMPv3-Trap and destination UDP Port No. are 162 among
SNMPv1, v2c, v3.

SNMP, IP address of entity, security level, and user name will require for setting
destination of Trap for SNMPv3.

Authentic method and authentic password will require if security level is


authNoPriv, authPriv.

Encryption algorithm, encrypted password will require if security level is


authPriv.

Note: Among SNMPv1, v2c, v3, SNMPv1-Trap is common setting


and can be registered up to 3 types of SNMPv1-Trap.

- Security (user authentication, Session management, encryption)

SNMPv3 is not available to certify by community name such as v1, v2c.


SNMPv3 is available to certify by User name, user registration will be required
before certification.

Operation NWD-107461-04E
4-38 NE Setup

User authentication will be execute if send the SNMP request that security level
is authNoPriv or authPriv.

Calculate of Auth algorithm for authentication password is MD5.

User registration will be required before certification.

Cipher communication will be executed after user authentication if send SNMP


request that security level is authPriv. Cipher algorithm is available to select
DES, AES and user registration include encrypted password will be required
before certification.

(4) NTP (Network Time Protocol)

This protocol is for synchronizing the time between server and client connecting
in network and specified by the following RFC.

Table 4-16 RFC Standards


RFC No. Title
RFC 1305 Network Time Protocol (Version 3) Specification, Implementation
and Analysis
RFC 2030 Simple Network Time Protocol (SNTP) Version 4 for IPv4, IPv6
and OS

iPASOLINK uses NTP Client and Server to provide the following functions:

- As NTP Client

In case that the unicast mode is selected on NTP Client, client sends a request of
the current time to the pre-configured server and then sets the time according to
information in the reply. Up to four NTP severs can be registered via the
WebLCT.

In case that the multicast mode is selected on NTP Client, client will listen the
broadcast of the time server and then set the time according to the first received
valid broadcast and ignore the broadcasts from other servers if any.

NTP Client received neither reply nor broadcasts which cause synchronization
cannot be accomplished, and current time of the equipment will be used.

NWD-107461-04E Operation
NE Setup 4-39

- As NTP Server

In case that the unicast mode is selected on NTP server, server will reply the
client with his time information.

In case the multicast mode is selected, server will broadcast his time information
periodically.

(5) FTP (File Transfer Protocol)

This protocol is for transferring the file among network equipments, and
specified by the following RFC.

Table 4-17 RFC Standard


RFC No. Title
RFC 959 Original FTP spec.
RFC 1123 The small FTP related section extends / clarifies RFC-959.
RFC 2228 FTP security extensions (vsftpd implements the small subset
needed to support TLS / SSL connections).
RFC 2389 Proposes FEAT and OPTS commands
RFC 2428 Essentially IPv6 support.

iPASOLINK is used as FTP Server to provide the following functions:

- Data upload and download service

Provide the data upload and download service; however data download is
available only when user is assigned with the proper privilege (refer to 4.3.1
User Access Levels).

The files and the directories that can be accessed via FTP protocol are
predetermined as well as the file name and type which will be downloaded.

- Session management

Accept the connection from external device then conduct Login Authentication
process. Anonymous user is not available.

Using the default TCP port 21 for listening and transferring the file on TCP port
20, user can change the default setting by the WebLCT. When Passive Mode is
selected, the port number is decided by the equipment automatically.

If no command is detected on client within ninety seconds, current TCP session


will be broken automatically.

Operation NWD-107461-04E
4-40 NE Setup

- User authentication function

iPASOLINK supports three types of the authentication, external RADIUS server


with internal authentication, external LDAP server with internal authentication
and internal authentication only.

(6) HTTP (Hyper Text Transfer Protocol)

HTTP is the protocol for transferring data between Web server and client
(WebLCT).

The HTTP is base on the following RFC standard.

Table 4-18 RFC Standard


RFC No. Title
RFC 1945 Hypertext Transfer Protocol -- HTTP/1.0
RFC 2616 Hypertext Transfer Protocol -- HTTP/1.1

iPASOLINK is used as HTTP server to provide the following functions.

- WebLCT

Allows user to operate the WebLCT via HTTP protocol.

- Session Management

Accepts the connection from external device then conduct Login Authentication
process. Anonymous user is not available.

The default port number of HTTP service is 80, and user can change it on the
WebLCT.

- User authentication function

iPASOLINK supports internal authentication only.

NWD-107461-04E Operation
NE Setup 4-41

4.3.4.1 Service Status Setting

This window displays the status of service and protocol.

Procedure 4-10

1. Expand User Account / Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Confirm the status of each
Service.

Operation NWD-107461-04E
4-42 NE Setup

Figure 4-46 Service Status Setting Window

NWD-107461-04E Operation
NE Setup 4-43

Table 4-19 Service Status


Status Description
Running Protocol or service is enable
Stopped Protocol or service is disable

This step ends the procedure.

4.3.4.2 SNMP

Procedure 4-11

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click SNMP.

Click SNMP.

Figure 4-47 Service Status Setting Window

5. The SNMP Setting box appears. Specify a proper value for each parameter.

Operation NWD-107461-04E
4-44 NE Setup

Figure 4-48 SNMP Setting Box

Table 4-20 SNMP Parameter


Item Parameter Description
SNMPv1/ Enable Enable SNMPv1/v2c (running)
SNMPv2c Disable Disable SNMPv1/v2c (stopped)
SNMPv3 Enable Enable SNMPv3 (running)
Disable Disable SNMPv3 (stopped)
UDP Port 161 Default port is 161
Range: 1 to 65535

NWD-107461-04E Operation
NE Setup 4-45

Caution

You must reboot the CPU for applying the value properly after changing the
UDP port number.

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button.

Figure 4-49 Information Box

8. The Service Status Setting window appears again. Confirm SNMP


information displayed.

Figure 4-50 Service Status Setting Window (1/2)

Operation NWD-107461-04E
4-46 NE Setup

Figure 4-50 Service Status Setting Window (2/2)

This step ends the procedure.

4.3.4.3 SNMP Community

Registers, modifies, or deletes the SNMP Manager information. Only the registered
SNMP managers have the right to access to the equipment. Up to ten servers can be
registered.

(1) Registration of SNMP Community

Procedure 4-12

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click Community No. of the
SNMP Community field.

NWD-107461-04E Operation
NE Setup 4-47

Community No.

Figure 4-51 Service Status Setting Window

5. The SNMP Community box appears. Specify a proper value of each


parameter.

Figure 4-52 SNMP Community Box

Table 4-21 SNMP Community Parameter


Item Parameter Description
Community Name 1 to 31 characters Set the SNMP community name. Any request with
different community name will be refused.
Access Level (Admin/Config/Operator) Specify the user access level.
(For more details refer to Table 4-3 User Access
Privilege Levels)
Access Control Enable/Disable It is a setting not to be able to access it from the host
who does not belong to this subnet.
Source IP Address xxx.xxx.xxx.xxx Specify the valid IP address or network of the SNMP
manager(s).
Subnet Mask x.x.x.x Subnet Mask of SNMP manager(s)

Operation NWD-107461-04E
4-48 NE Setup

6. Click OK button after configuring the parameters.

7. The Information box appears, then click OK button.

Figure 4-53 Information Box

8. The Service Status Setting window appears again. Confirm the newly added
SNMP community information displayed.

Figure 4-54 Service Status Setting Window

This step ends the procedure.

(2) Modify SNMP Community

Procedure 4-13

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click Community No. of


SNMP Community field.

NWD-107461-04E Operation
NE Setup 4-49

Community No.

Figure 4-55 Service Status Setting Window

5. The SNMP Community box appears. Modify the parameters accordingly.

Figure 4-56 SNMP Community Box

Table 4-22 SNMP Community Parameter


Item Parameter Description
Community Name 1 to 31 characters SNMP Community name. Any request with
different community name will be refused.
Access Level (Admin/Config/Operator) Specify the user access level.
(For more details refer to Table 4-3 User Access
Privilege Levels)
Access Control Enable/Disable It is a setting not to be able to access it from the
host who does not belong to this subnet.
Source IP Address xxx.xxx.xxx.xxx Specify the valid IP address or network of the
SNMP manager(s).
Subnet Mask x.x.x.x Subnet Mask of management server(s)

6. Click OK button after configuring the parameters.

Operation NWD-107461-04E
4-50 NE Setup

7. The Information box appears. Click OK button.

Figure 4-57 Information Box

8. The Service Status Setting window appears again. Confirm the SNMP
Community information displayed.

Figure 4-58 Service Status Setting Window

This step ends the procedure.

(3) Delete SNMP Community

Procedure 4-14

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. Click Delete SNMP Community on the top of the Service Status Setting
window.

NWD-107461-04E Operation
NE Setup 4-51

Delete SNMP Community

Figure 4-59 Service Status Setting Window

5. The Delete SNMP Community box appears. Select the SNMP Community
No. from the drop-down list, and then click OK button.

Figure 4-60 Delete SNMP Community Box

6. The Confirmation box appears. Click OK button.

Figure 4-61 Confirmation Box

7. The Information box appears. Click OK button.

Operation NWD-107461-04E
4-52 NE Setup

Figure 4-62 Information Box

8. The Service Status Setting window appears again. Confirm the SNMP
Community information displayed.

Figure 4-63 Service Status Setting Window

This step ends the procedure.

4.3.4.4 SNMP Trap Entry

This function provide user to configure the parameters of SNMP Trap.

(1) SNMP Trap Entry

Procedure 4-15

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click SNMP Trap Entry No.
of the SNMP Trap Entry field.

NWD-107461-04E Operation
NE Setup 4-53

SNMP Trap Entry No.

Figure 4-64 Service Status Setting Window

5. The SNMP Trap Entry box appears. Specify a proper value for each parameter.

(a) SNMPv1

Figure 4-65 SNMPv1 Trap Entry Box

Operation NWD-107461-04E
4-54 NE Setup

(b) SNMPv2c

Figure 4-66 SNMPv2c Trap Entry Box

(c) SNMPv3

Figure 4-67 SNMPv3 Trap Entry Box

NWD-107461-04E Operation
NE Setup 4-55

Table 4-23 SNMP Trap Entry Parameter


Item Parameter Description
SNMP Version v1/ v2c / v3 Set SNMP version for trap
PDU Type Trap / Inform Set PDU Type for trap
IP Address x.x.x.x Specify the destination IP address of trap
UDP Port 162 Set UDP Port of trap
(Range: 1 -
65535)
CommunityName 1 to 31 Set communication name of the trap. This
characters must match on both SNMP server and agent.
Security Level NoAuthNoPriv User login without authentication and
encryption.
AuthNoPriv User login need authentication (MD5 or
SHA1 based) but without encrypted.
AuthPriv User login need authentication (MD5 or
SHA1 based) and the data is encrypted by
DES or AES.
SNMP Engine ID 10 to 64 SNMPv3 local engineid
numeric
characters
Auth Algorithm MD5 One of the Auth Algorithm for authentication
and digital signature. In order to detect the
falsification of Original data during the data
transmitting, Original data will be converting
the auth by comparing at both ends. .
SHA One of the Auth Algorithm for authentication
and digital signature. In order to detect the
falsification of Original data during the data
64
transmitting, Less than 2 bits of original
data will be converting the auth of 160 bits by
comparing at both ends.
Auth Key 8 to 16 Input 8 to 16 digits Public key of MD5 or
SHA1
Priv Algorithm DES The DES function use encryption by
64bits/blog and use 56bits encryption of key
ASE The encryption of SPN structure, use 128 bits
blog length and the 128/192/256 bits of key
length
Priv Key 8 to 16 Input 8 to 16 digits key of DES or AES

Operation NWD-107461-04E
4-56 NE Setup

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button.

Figure 4-68 Information Box

8. The Service Status Setting window appears again. Confirm newly added
SNMP trap entry information displayed.

Figure 4-69 Service Status Setting Window

This step ends the procedure.

(2) Modify SNMP Trap Entry

Procedure 4-16

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click SNMP Trap Entry No.
of the SNMP Trap Entry field.

NWD-107461-04E Operation
NE Setup 4-57

SNMP Trap Entry No.

Figure 4-70 Service Status Setting Window

5. The SNMP Trap Entry box appears. Modify the parameters accordingly.

Figure 4-71 SNMP Trap Entry Box

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button.

Figure 4-72 Information Box

Operation NWD-107461-04E
4-58 NE Setup

8. The Service Status Settings window appears again. Confirm the SNMP trap
entry information displayed.

Figure 4-73 Service Status Setting Window

This step ends the procedure.

(3) Delete SNMP Trap Entry

Procedure 4-17

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click Delete SNMP Trap
Entry.
Delete SNMP Trap Entry

Figure 4-74 Service Status Setting Window

NWD-107461-04E Operation
NE Setup 4-59

5. The Delete SNMP Trap Entry box appears. Select the SNMP Trap Entry
No. from the drop-down list, and then click OK button.

Figure 4-75 Delete SNMP Trap Entry Box

6. The Confirmation box appears. Click OK button.

Figure 4-76 Confirmation Box

7. The Information box appears. Click OK button.

Figure 4-77 Information Box

8. The Service Status Setting window appears again. Confirm the SNMP Trap
Entry information displayed.

Operation NWD-107461-04E
4-60 NE Setup

Figure 4-78 Service Status Setting Window

This step ends the procedure.

4.3.4.5 NTP

Procedure 4-18

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click NTP.

Click NTP.

Figure 4-79 Service Status Setting Window

5. The NTP Setting box appears. Assign a proper value for each parameter.

NWD-107461-04E Operation
NE Setup 4-61

Figure 4-80 NTP Setting Box

Table 4-24 NTP Parameter


Item Parameter Description
NTP Disable Enable NTP protocol on the
Enable equipment
NTP Server Mode Unicast Setup NTP Server mode
Multicast
Disabled
NTP Client Mode Unicast Setup NTP Client mode
Multicast
Disabled
Stratum Range: 2 to 15 Stratum setup
Multicast Port NE2 Select pull down list to Multicast Port
Bridge
Brigde1
Brigde2
Multicast Interval Range: 16 to 131072S Select pull down list to Multicast
Interval

6. Click OK button after configuring the parameters.

7. The Information box appears, then click OK button.

Operation NWD-107461-04E
4-62 NE Setup

Figure 4-81 Information Box

8. The Service Status Setting window appears again. Confirm the NTP
configuration displayed.

Figure 4-82 Service Status Setting Window (1/2)

Figure 4-82 Service Status Setting Window (2/2)

This step ends the procedure.

NWD-107461-04E Operation
NE Setup 4-63

4.3.4.6 NTP Server Address

This function provide user to register/modify/delete the NTP Server.

(1) Registration NTP Server Address

Procedure 4-19

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click NTP Server No. of the
NTP Server Address field.

NTP Server No.

Figure 4-83 Service Status Setting Window

5. The NTP Server Address Setting box appears. Assign a proper value for
each parameter.

Operation NWD-107461-04E
4-64 NE Setup

Figure 4-84 NTP Server Address Setting Box

Table 4-25 NTP Server Address


Item Parameter Description
IP Address x.x.x.x Set the upper NTP server IP address
NTP Version 3 or 4 Specify the NTP message version
Poll Time 1 min 4 Sec Set the interval of polling NTP server.
(Range: 16 to 131072) Default is 1 min 4 sec

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button.

Figure 4-85 Information Box

8. The Service Status Setting window appears. Confirm newly added NTP
Server Address information displayed.

NWD-107461-04E Operation
NE Setup 4-65

Figure 4-86 Service Status Setting Window

This step ends the procedure.

(2) Modify NTP Server Address

Procedure 4-20

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. Service Status Setting window appears. Click the NTP Server No. of the
NTP Server Address field.

Operation NWD-107461-04E
4-66 NE Setup

NTP Server No.

Figure 4-87 Service Status Setting Window

5. The NTP Server Address Setting box appears. Modify the parameters
accordingly.

Figure 4-88 NTP Server Address Setting Box

6. Click OK button after configuring the parameters.

7. The Information window appears. Click OK button.

Figure 4-89 Information Box

NWD-107461-04E Operation
NE Setup 4-67

8. The Service Status Setting window appears again. Confirm the NTP Server
Address information displayed.

Figure 4-90 Service Status Setting Window

This step ends the procedure.

(3) Clear NTP Server Address

Procedure 4-21

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click Clear NTP Server.

Operation NWD-107461-04E
4-68 NE Setup

Clear NTP Server button

Figure 4-91 Service Status Setting Window

5. The Clear NTP Server box appears. Select the NTP Server Address number
from drop-down list, and then click OK button.

Figure 4-92 Clear NTP Server Box

6. The Confirmation box appears. Click OK button.

Figure 4-93 Confirmation Box

7. The Information box appears. Click OK button.

NWD-107461-04E Operation
NE Setup 4-69

Figure 4-94 Information Box

8. The Service Status Setting window appears again. Confirm the NTP Server
Address information displayed.

Figure 4-95 Service Status Setting Window

This step ends the procedure.

4.3.4.7 FTP

Procedure 4-22

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click FTP.

Operation NWD-107461-04E
4-70 NE Setup

Click FTP.

Figure 4-96 Service Status Setting Window

5. The FTP Setting box appears. Assign a proper value for each parameter.

Figure 4-97 FTP Setting Box

NWD-107461-04E Operation
NE Setup 4-71

Table 4-26 FTP


Item Parameter Description
FTP Always Enable Always FTP service running
Service Enable Enable FTP service
Service Disable Disable FTP service
TCP 21 Set the TCP port of FTP server (for
Port(Command) (Range: 1 to 65535) received command). Default is 21.
TCP Port (Data) 20 Set the TCP port of FTP server (For data
(Range: 1 to 65535) transmit). Default is 20.
MAX Session 3 Maximum user connection.
(Range: 1 to 3)
Auto Stop Enable Enable FTP server break the connection in
90 sec automatically after no operation on
the client.
Disable Disable FTP server break the connection
in 90 sec automatically after no operation
on the client.

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button.

Figure 4-98 Information Box

8. The Service Status Setting window appears again. Confirm the FTP
information displayed.

Operation NWD-107461-04E
4-72 NE Setup

Figure 4-99 Service Status Setting Window (1/2)

Figure 4-99 Service Status Setting Window (2/2)

This step ends the procedure.

4.3.4.8 HTTP

Procedure 4-23

1. Expand User Account/Security Setting from the WebLCT menu.

2. Expand Security Management from the User Account/Security Setting


sub menu.

NWD-107461-04E Operation
NE Setup 4-73

3. Select Service Status Setting from the Security Management sub menu.

4. The Service Status Setting window appears. Click HTTP.

Click HTTP.

Figure 4-100 Service Status Setting Window

5. The HTTP Setting box appears. Assign a proper value for each parameter.

Figure 4-101 HTTP Setting Box

Table 4-27 HTTP


Item Parameter Description
HTTP Enable (Running) Enable HTTP service
Disable (Stopped) Disable HTTP service
TCP Port 80 Set the port number of HTTP server.
(Range: 1 to 65535) Default is 80.

Operation NWD-107461-04E
4-74 NE Setup

6. Click OK button after configuring the parameters.

7. The Information box appears. Click OK button

Figure 4-102 Information Box

8. The Service Status Setting window appears again. Confirm the HTTP
information displayed.

Figure 4-103 Service Status Setting Window (1/2)

This step ends the procedure.

NWD-107461-04E Operation
NE Setup 4-75

4.4 Register NE Configuration

4.4.1 Easy Setup Wizard


The Easy Setup Wizard provides user a faster and easier way to configure the
equipment when powering on at the first time.

The Easy Setup Wizard contains the following items.

z Easy Setup

Setting of NE Name, Switch Group (System structure) and guide to other setups.

z MODEM Setup

Setting for Channel Spacing, Mode, E1/STM-1 Mapping, RF Frequency


regarding to Radio.

z Management Setup

Setting for IP address, Subnet mask and default gateway for NE.

z TDM Setup

Setting of TDM cross connect.

z ETH Setup

Setting of VLAN service

4.4.1.1 Easy Setup

The easy setup is a wizard that guides the user to set up the basic configuration by
following the correct sequences.

Procedure 4-24

1. Expand Easy Setup Wizard from the WebLCT menu.

2. Select the Easy Setup from the Easy Setup Wizard sub menu.

3. The Easy Setup window appears. Click Setup button.

Operation NWD-107461-04E
4-76 NE Setup

Setup button.

Figure 4-104 Easy Setup Window

4. The Easy Setup - Step1 window appears. Enter the equipment name then
click Next button.

NWD-107461-04E Operation
NE Setup 4-77

Next button

Figure 4-105 Easy Setup - Step1 Window

Note
The left part of the window shows the current setup while on the right part of
the window, user can edit the configuration.

Table 4-28 Easy Setup (Equipment Name)


Item Description
Equipment Name 1 to 32 characters

5. The Easy Setup - Step2 window appears. Assign a proper value for each
parameter.

Operation NWD-107461-04E
4-78 NE Setup

Figure 4-106 Easy Setup – Step2 Window

Table 4-29 Easy Setup (Equipment Configuration)


Item Description
Equipment STM1-S Through or STM1-S Channelized is selectable.
Configuration

6. The Easy Setup – Step3 window appears. Assign a proper value for each
parameter.

NWD-107461-04E Operation
NE Setup 4-79

Figure 4-107 Easy Setup - Step3 Window

Table 4-30 Easy Setup


Item Description
SW Group Check 1+1 TP, 1+1 HS, or 1+0 XPIC is selectable
Radio Box Not Check Select the Used/ Not Used of MODEM1
Select the Used/ Not Used of MODEM2

7. Click Next button after configuring the parameters.

8. The Easy Setup - Step4 window appears. The parameters that have been
modified will be marked with blue background. Confirm the value of the
parameters and then OK button.

Operation NWD-107461-04E
4-80 NE Setup

Figure 4-108 Easy Setup - Setp4 Window

9. The Warning box appears. Click OK button.

Figure 4-109 Warning Box

10. The Information box appears. Click OK button.

Figure 4-110 Information Box

11. The MODEM Setup wizard appears. Refer to the next sub section for details.

This step ends the procedure.

NWD-107461-04E Operation
NE Setup 4-81

4.4.1.2 MODEM Setup

Procedure 4-25

1. After Easy Setup wizard is completed or MODEM Setup is selected from the
Easy Setup Wizard sub menu, click the Setup button.

2. The MODEM Setup - Step1 window appears. Assign a proper value for each
parameter.

Figure 4-111 MODEM Setup - Step1 Window

Operation NWD-107461-04E
4-82 NE Setup

Table 4-31 Modem Setup


Item Parameter Description
Channel Spacing 7 / 14/ 28/ 56 [MHz] Specify the radio channel spacing
Reference QPSK Specify the reference modulation from
Modulation 16/ 32/ 64/ 128/ 256 [QAM] the list
E1 Mapping 0 to 152 [CH] Specify the number of E1 CH for
mapping. (The number of CH should not
exceed the limitation of the specified
modulation.)
STM-1 Mapping 0 to 2 [CH] Specify the number of STM-1 CH for
mapping.
ETH Bandwidth [Mbps] Specify the bandwidth of the ether traffic
TX RF Frequency [MHz] Set transmit frequency
RX RF Frequency [MHz] Set receive frequency
Frame ID 1 to 32 Set frame ID (1+0, 1+1 HS, 1+1 TP)
1 to 16 Set frame ID (MODEM1, XPIC)
17 to 32 Set frame ID (MODEM2, XPIC)
TX Power Control MTPC / ATPC Set transmit power control mode

3. Click Next button after configuring the parameters. (When two MODEMs are
used, setup window for MODEM2 appears. Configure the parameters for
MODEM2.)

4. The MODEM Setup - Step2 window appears. The parameters that have been
modified will be marked with blue background. Confirm the value of the
parameters and then click OK button.

NWD-107461-04E Operation
NE Setup 4-83

Figure 4-112 MODEM Setup - Step2 Window

5. The Warning box appears. Click OK button.

Figure 4-113 Warning Box

6. The Information box appears. Click OK button.

Figure 4-114 Information Box

7. The Management Setup wizard appears. Refer to the next sub section for
details.

This step ends the procedure.

Operation NWD-107461-04E
4-84 NE Setup

4.4.1.3 Management Setup

Note: The Warning box appears Click Maintenance button on the top of the
LCT window to turn on maintenance mode.

Procedure 4-26

1. After the MODEM Setup wizard is completed or Management Setup is


selected from the Easy Setup Wizard sub menu, click the Setup button.
The Management Setup box appears.

2. Assign a proper value for each parameter.

Figure 4-115 Management Setup Box

Table 4-32 Management Network Configuration


Item Parameter Description
IP Address Setting (Bridge1)
IP Address x.x.x.x Input IP Address of NMS port
Subnet Mask x.x.x.x Input Subnet Mask of NMS port
Default Gateway x.x.x.x Input Default Gateway IP address
NMS Port Setting
Connect NMS Port to NMS Yes Use NMS Port (for root NE only)
No Not use NMS Port

3. Click OK button.

4. The Information box appears. Click OK button.

NWD-107461-04E Operation
NE Setup 4-85

Figure 4-116 Information Box

5. The Management Setup wizard appears. Refer to the next sub section for
details.

This step ends the procedure.

4.4.1.4 TDM Setup

Procedure 4-27

1. After the Management Setup wizard is completed or TDM Setup is selected


from the Easy Setup Wizard sub menu, the TDM Setup Wizard window
appears.

2. Click Add More XC button.

Add More XC button

Figure 4-117 TDM Setup Wizard Window

Operation NWD-107461-04E
4-86 NE Setup

3. The TDM XC Configuration window appears. Specify the proper value for
each parameter and then click OK button.

Figure 4-118 TDM XC Configuration Window

4. The TDM XC Service Configuration List window appears. Click OK button.

OK button

Figure 4-119 Service Configuration List Window

Note: By checking the Enable E1 CH Usage check box, E1 channel


communication is enabled after completion of Easy Setup.
(Default: Unchecked)

5. The Information box appears Click OK button.

NWD-107461-04E Operation
NE Setup 4-87

Figure 4-120 Information Box

6. The ETH Setup wizard appears. Refer to the next sub section for details.

This step ends the procedure.

4.4.1.5 ETH Setup

Procedure 4-28

1. After the TDM Setup wizard is completed or ETH Setup is selected from the
Easy Setup Wizard sub menu, the ETH Setup wizard appears. Click Setup
button.

2. The E-Line Service Configuration window appears. Specify a proper value


for each parameter then click Next button.

Next button

Figure 4-121 E-Line Service Configuration Window

Operation NWD-107461-04E
4-88 NE Setup

Table 4-33 E-Line Service Configuration Parameter


Item Parameter Description
VLAN ID 1 to 4094 Specify the ID of the VLAN
VALN Service 1 to 32 Character Specify the service name of the VLAN
Name
Service Type EPL Refer to Note 1
EVPL Refer to Note 2
Enable ETH Port Check / Uncheck Enables ETH port communication after
Usage (Default: Uncheck) setting of Easy Setup

Notes
1. EPL (Ethernet Private Line)
EPL is a data service defined by the Metro Ethernet Forum, providing a
point-to-point Ethernet connection between a pair of dedicated
User-Network Interfaces (UNIs), with a high degree of transparency.
EPL service is specified using an E-Line service type, with an expectation of
low Frame Delay, Frame Delay Variation and Frame Loss Ratio. EPL is
implemented as a point-to-point Ethernet Virtual Connection (EVC) which,
unlike Ethernet Virtual Private Line (EVPL), does not allow for Service
Multiplexing, i.e., a dedicated UNI (physical interface) is used to accept all
service frames and map them to a single EVC (a.k.a. All-to-one bundling).
Due to a high degree of transparency, EPL is often used to provide
point-to-point Transparent LAN Service (TLS), where the Service Frame’s
header and payload are identical at both the source and destination UNI.
EPL is not fully transparent, as it must filter IEEE 802.3x Pause frames.
2. EVPL (Ethernet Virtual Private Line)
Ethernet Virtual Private Line (EVPL) is a data service defined by the Metro
Ethernet Forum, providing a point-to-point Ethernet connection between a
pair of User-Network Interfaces (UNIs).
EVPL service is specified using an E-Line service type, very similar to a
Ethernet Private Line (EPL) service, via a point-to-point Ethernet Virtual
Connection (EVC). However, unlike EPL, EVPL allows for Service
Multiplexing, i.e., multiple EVCs or Ethernet services per UNI.
The other difference between the EVPL and EPL is the degree of
transparency - while EPL is highly transparent, filtering only the Pause
frames, EVPL is required to either peer or drop most of the Layer 2 Control
Protocols.

3. The E-LAN Service Configuration window appears, and then click OK


button.

NWD-107461-04E Operation
NE Setup 4-89

OK button

Figure 4-122 E-LAN Service Configuration Window

Table 4-34 E-LAN Service Configuration


Item Parameter Description
VLAN ID 1 to 4094 Specify the ID of the VLAN
VALN Service 1 to 32 Character Specify the service name of the VLAN
Name
Service Type EP-LAN Refer to Note 3
EVP-LAN Refer to Note 4
Enable ETH Port Checked / unchecked Enables ETH port communication after
Usage setting of Easy Setup

Notes
1. Ethernet Private LAN (EPLAN) is a Metro Ethernet service type defined by
the Metro Ethernet Forum.
Because E-LAN services implement multipoint-to-multipoint Ethernet virtual
connections (EVC), multiple locations can be interconnected using an
EPLAN service. However, each location can be a member of one and only
one EVC. If a given location requires connection to a second EVC, it will
require a second UNI.
Because there is only one EVC per UNI, the EVC can be invisible to the
customer (e.g., the customer will not see an 802.1p VLAN tag).

Operation NWD-107461-04E
4-90 NE Setup

2. Ethernet Virtual Private LAN (EVPLAN) is a Metro Ethernet service type


defined by the Metro Ethernet Forum.
Because E-LAN services implement multipoint-to-multipoint Ethernet virtual
connections (EVC), this service provides Metro Ethernet with a multipoint
service that can support multiple overlapping closed-user groups. For
example, a district school system with elementary, middle, and high schools
could put on of the high schools on one EVC , all of the middle schools on a
second EVC, and all of the elementary schools on a third EVC, using
EPLAN services at each school. The district data center and administrative
offices could have EVPLAN service and be made a member of all three
EVCs without the need for three UNIs.
Because there are multiple EVCs per UNI in an EVPLAN service, the EVCs
must be visible to the customer. To do this, the service provider expects
customer traffic to have an appropriate 802.1p VLAN tag when submitted.
The network will also deliver tagged traffic to that location so that the
customer knows which EVC traffic is arriving from.

4. The Warning box appears. Click OK button.

Figure 4-123 Warning Box

5. The Information box appears. Click OK button.

Figure 4-124 Information Box

6. The ETH Setup window appears.

NWD-107461-04E Operation
NE Setup 4-91

Figure 4-125 ETH Setup window

This step ends the procedure.

Operation NWD-107461-04E
4-92 NE Setup

4.4.2 Equipment Setup


The Equipment Setup provides more detail setting than it done in the Easy Setup
Wizard. Some parameters are included in the Easy Setup Wizard.

• Equipment Configuration

Setting for NE Name, Switch Group (System structure)

• Radio Configuration

Setting for Channel Spacing, Mode, E1/STM-1 Mapping, RF Frequency for


Radio.

• AMR Configuration

Setting for the mode type and range for AMR

• Network Management Configuration

Setting for IP Address of each port and functions that mounted at the front face
of iPASOLINK

NWD-107461-04E Operation
NE Setup 4-93

4.4.2.1 Equipment Configuration

Procedure 4-29

1. Expand Equipment Setup from the WebLCT menu.

2. Select Equipment Configuration from the Equipment Setup sub menu.

3. The Equipment Configuration window appears, then click Setup button.

Setup button

Figure 4-126 Equipment Configuration Window

4. The Step1 window appears. Input Equipment Name and then click Next
button.

Operation NWD-107461-04E
4-94 NE Setup

Figure 4-127 Step1 Window

Note
The left part of the window shows the current setup while on the right part of the
window, user can edit the configuration.

Table 4-35 Equipment Configuration (Equipment Name)


Parameter Description
Equipment Name 1 to 32 characters

5. The Step2 window appears, input necessary parameter, and then click Next
button.

NWD-107461-04E Operation
NE Setup 4-95

Figure 4-128 Step2 Window

Table 4-36 Equipment Configuration


Item Description
Equipment STM1-S Through or STM1-S Channelized is selectable.
Configuration

6. The Step3 window appears, input necessary parameter, and then click Next
button.

Operation NWD-107461-04E
4-96 NE Setup

Next button

Figure 4-129 Step3 Window

Table 4-37 Equipment Configuration


Item Description
SW Group Check 1+1 TP, 1+1 HS, or 1+0 XPIC is selectable
Radio Box Not Check Select the Used/ Not Used for MODEM1
Select the Used/ Not Used for MODEM2

7. The Step4 window appears. Confirm that the setup parameter changes to blue,
and then click OK button.

NWD-107461-04E Operation
NE Setup 4-97

Figure 4-130 Step4 Window

8. The Warning box appears. Click OK button.

Figure 4-131 Warning Box

9. The Information box appears. Click OK button.

Figure 4-132 Information Box

10. The Equipment Configuration window appears again. Confirm the


Equipment Configuration displayed.

Operation NWD-107461-04E
4-98 NE Setup

Figure 4-133 Equipment Configuration Window

This step ends the procedure.

4.4.2.2 Radio Configuration

Procedure 4-30

1. Expand Equipment Setup from the WebLCT menu.

2. Select Radio Configuration from the Equipment Setup sub menu.

3. The Radio Configuration window appears. Click Setup button.

NWD-107461-04E Operation
NE Setup 4-99

Setup button

Figure 4-134 Radio Configuration Window

4. The Step1 window appears. Input all necessary parameters and then click Next
button.

Operation NWD-107461-04E
4-100 NE Setup

Next button

Figure 4-135 Step1 Window (MODEM1)

NWD-107461-04E Operation
NE Setup 4-101

Figure 4-136 Step1 Window (MODEM2)

Table 4-38 Radio Configuration Parameter


Item Parameter Description
Channel Spacing 7 / 14/ 28/ 56 [MHz] Set the channel spacing
Reference QPSK / 16/ 32/ 64/ 128/ Set the specified reference modulation
Modulation 256 [QAM] from the list
E1 Mapping 0 to 152 [CH] Specify the number of E1 CH for
mapping.
STM-1 Mapping 0 to 2 [CH] Specify the number of STM-1 CH for
mapping.
ETH Bandwidth [Mbps] Not available
TX RF Frequency [MHz] Setup transmit RF Frequency
RX RF Frequency [MHz] Setup receive RF Frequency
Frame ID 1 to 32 Set frame ID (1+0, 1+1 HS, 1+1 TP)
1 to 16 Set frame ID (MODEM1, XPIC)
17 to 32 Set frame ID (MODEM2, XPIC)
TX Power Control MTPC/ ATPC Setup transmit Power

Operation NWD-107461-04E
4-102 NE Setup

5. Click Next button after configuring the parameters.

6. The Step2 window appears. Confirm that the setup parameter changes to blue
then click OK button.

Figure 4-137 Step2 Window

7. The Warning box appears. Click OK button.

Figure 4-138 Warning Box

8. The Information box appears. Click OK button.

Figure 4-139 Information Box

NWD-107461-04E Operation
NE Setup 4-103

9. The Radio Configuration window appears again. Confirm the Radio


Configuration displayed.

Figure 4-140 Radio Configuration Window

This step ends the procedure.

4.4.2.3 AMR Configuration

Procedure 4-31

1. Expand Equipment Setup from the WebLCT menu.

2. Select Radio Configuration from the Equipment Setup sub menu.

3. The AMR Configuration window appears. Click Setup button.

Operation NWD-107461-04E
4-104 NE Setup

Setup button

Figure 4-141 AMR Configuration Window

4. The Step1 window appears. Assign a proper value for each parameter for
MODEM1.

Figure 4-142 Step1 Window (MODEM1)

NWD-107461-04E Operation
NE Setup 4-105

Table 4-39 AMR Configuration


Item Parameter Description
AMR AMR Mode Enable AMR Range mode
Operation Non Operation Unable to setup AMR Range / E1 Mapping
AMR Range QPSK Data transmission for 1 time is 4 values (2 bits)
16 QAM Data transmission for 1 time is 16 values (4 bits)
32 QAM Data transmission for 1 time is 32 values (5 bits)
64 QAM Data transmission for 1 time is 64 values (6 bits)
128 QAM Data transmission for 1 time is 128 values (7 bits)
256 QAM Data transmission for 1 time is 256 values (8 bits)

5. Click Next button after configuring the parameters.

6. The Step2 window appears. Setup E1 Mapping of the AMR Range field
[QAM].

Figure 4-143 Step2 Window (MODEM1)

Operation NWD-107461-04E
4-106 NE Setup

Table 4-40 E1 Mapping


Item Parameter
E1 QPSK Select following items.
Mapping 16 QAM - E1 Mapping (Range: 0 - 152)
32 QAM - STM-1 Mapping (Range: 0 - 2)
64 QAM - ETH Bandwidth is calculated from E1 and
128 QAM STM-1 mapping
256 QAM

7. The Step1 window appears again. Assign a proper value for each parameter for
MODEM2.

Figure 4-144 Step1 Window (MODEM2)

8. Click Next button after configuring the parameters.

9. The Step2 window appears again. Setup E1 Mapping of the AMR Range
field [QAM].

NWD-107461-04E Operation
NE Setup 4-107

Figure 4-145 Step2 Window (MODEM2)

10. Click Next button after configuring the parameters.

11. The Step3 window appears. Confirm that the setup parameter changes to blue,
and then click OK button.

Figure 4-146 Step3 Window

Operation NWD-107461-04E
4-108 NE Setup

12. The Information box appears. Click OK button.

Figure 4-147 Information Box

13. The AMR Configuration window appears. Confirm that all parameters are set.

Figure 4-148 AMR Configuration Window

This step ends the procedure.

4.4.2.4 Network Management Configuration

In this menu execute the setting of function for each port mounted on front face of
iPASOLINK.

NWD-107461-04E Operation
NE Setup 4-109

• General Setting

In order to connect the iPASOLINK and NMS, execute the setting for using/un
using of NMS Port and IP Address.

• General Setting (Detail)

Setting for IP Address of each port (NE2, Inband Management VLAN) and NE
Branch (NMS/NE/MODEM)

• Routing Setting

Setting the Routing information for selecting the fixed route

(1) General Setting

Procedure 4-32
1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.
2. Expand Equipment Setup from the WebLCT menu.

3. Expand Network Management Configuration from the Equipment Setup


sub menu.

4. Select General Setting from the Network Management Configuration


sub menu.

5. The General Setting window appears. Click Setup button.

Figure 4-149 General Setting Window

6. The General Setting box appears. Setup all parameters.

Operation NWD-107461-04E
4-110 NE Setup

Figure 4-150 General Setting Box

Table 4-41 General Setting


Item Parameter Description
IP Address Setting (Bridge1)
IP Address x.x.x.x Input IP Address of NMS port
Subnet Mask x.x.x.x Input Subnet Mask of NMS port
Default Gateway x.x.x.x Input Default Gateway address
NMS Port Setting
Connect NMS Port to NMS Yes Use NMS port
No Not use NMS port

7. Click OK button after configuring the parameters.

8. The Information box appears. Click OK button.

Figure 4-151 Information Box

9. The General Setting window appears again. Confirm that all parameters are
set.

NWD-107461-04E Operation
NE Setup 4-111

Figure 4-152 General Setting Window

10. After finishing General Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.

11. Confirm that the MAINT changes from yellow to white.

This step ends the procedure.

(2) General Setting (Details)

Procedure 4-33

1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.

2. Expand Equipment Setup from the WebLCT menu.

3. Expand Network Management Configuration from the Equipment Setup


sub menu.

4. Select General Setting (Detail) from the Network Management


Configuration sub menu.

5. The General Setting (Detail) window appears. Click Setup button.

Operation NWD-107461-04E
4-112 NE Setup

Setup button

Figure 4-153 General Setting (Detail) Window

6. The General Setting (Detail) box appears. Assign a proper value for each
parameter.

NWD-107461-04E Operation
NE Setup 4-113

Figure 4-154 General Setting (Detail) Box

Operation NWD-107461-04E
4-114 NE Setup

Table 4-42 NE2/Inband Management VLAN/Ethernet Port Parameter


Item Parameter Description
NE2 Port Setting
NE2 Port IP x.x.x.x Input IP Address of NE2 port
Address
NE2 Port Usage Used Use NE2 port
Not Used Not use NE2 port
NE2 Port Speed 9600 specify the line speed of NE2 port2
19200

Inband Management VLAN Setting


Inband Used Use Inband Management VLAN
Management VLAN Not Used Not use Inband Management VLAN
Usage
VLAN ID 1 to 4094 VLAN ID of the Inband
Management VLAN
IP Address x.x.x.x Input IP Address of Inband
Management VLAN
Subnet Mask x.x.x.x Input Subnet Mask of Inband
Management VLAN
Ethernet Port Setting (NMS / NE2 Port)
Usage Used Use Ethernet port
Not Used Not use Ethernet port
Auto Negotiation Enabled Enable the Auto Negotiation of
Ethernet port
Disabled Disable the Auto Negotiation of
Ethernet port
Discovery Usage Used search of the network access
Not Used machinery using Ethernet connect
NE Branch Setting
Branch Number 1 to 4 Branches Select the Branch Number
Default Gateway x.x.x.x Input the Default Gateway
Restrict LCT Connection
NMS Port Setting Yes Use NMS Port
No Not use NMS Port
LCT Port Setting Any Connection from Local/Remote to
LCT Port
Only to Local NE only connection from Local to LCT
Port

NWD-107461-04E Operation
NE Setup 4-115

7. Click the items (NMS/NE1/MODEM1/MODEM2) on the NE Branch Setting


field. The Bridge No. Setting box appears. Select the bridge No. from the drop-
down list and then click OK button.

Figure 4-155 Bridge No. Setting Box

8. The General Setting (Detail) box appears again. Click Bridge No. of the NE
Branch Setting field.

Bridge No.

Figure 4-156 General Setting (Detail) Box

Operation NWD-107461-04E
4-116 NE Setup

9. The IP Address Setting box appears. Input the IP address and the subnet
mask, and then click OK button.

Figure 4-157 IP Address Setting Box

10. The General Setting (Detail) box appears again.

Figure 4-158 General Setting (Detail) Box

NWD-107461-04E Operation
NE Setup 4-117

11. Click OK button after configuring the parameters.

12. The Information box appears. Click OK button.

Figure 4-159 Information Box

13. The General Setting (Detail) window appears again. Confirm that all
parameter are set.

Figure 4-160 General Setting (Detail) Window

14. After finishing General Setting (Detail), click Maintenance button on the top
of the WebLCT window to exit maintenance mode.

15. Confirm that the MAINT changes from yellow to white.

This step ends the procedure.

Operation NWD-107461-04E
4-118 NE Setup

(3) Routing Setting

This function provide user to specify the static route for the particular network or
IP address.

(a) Add Routing Setting

Procedure 4-34

1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.

2. Expand Equipment Setup from the WebLCT menu.

3. Expand Network Management Configuration from the Equipment Setup


sub menu.

4. Select Routing Setting from the Network Management Configuration


sub menu.

5. The Routing Setting window appears. Click Setup button.

Setup button

Figure 4-161 Routing Setting Window

6. The Routing Setting box appears. Click Add button.

NWD-107461-04E Operation
NE Setup 4-119

Figure 4-162 Routing Setting Box

7. The Routing Setting (Add) box appears. Input the IP Address, Subnet Mask,
and Gateway, and then click OK button.

Figure 4-163 Routing Setting (Add) Box

8. The Routing Setting box appears again. Confirm the newly added route
information displayed.

Operation NWD-107461-04E
4-120 NE Setup

Figure 4-164 Routing Setting Box

9. Click OK button after configuring the parameters.

10. The Confirmation box appears. Click OK button.

Figure 4-165 Confirmation box

11. The Information box appears. Click OK button.

Figure 4-166 Information Box

12. The Routing Setting window appears again. Confirm that the newly added
route information displayed.

NWD-107461-04E Operation
NE Setup 4-121

Figure 4-167 Routing Setting Window

13. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.

14. Confirm that the MAINT changes from yellow to white.

This step ends the procedure.

(b) Modify Routing Setting

Procedure 4-35

1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.

2. Expand Equipment Setup from the WebLCT menu.

3. Expand Network Management Configuration from the Equipment Setup


sub menu.

4. Select Routing Setting from the Network Management Configuration


sub menu.

5. The Routing Setting window appears. Click Setup button.

Setup button

Figure 4-168 Routing Setting Window

Operation NWD-107461-04E
4-122 NE Setup

6. The Routing Setting box appears. Click the IP Address to be modified.

Figure 4-169 Routing Setting Box

7. The Routing Setting (Modify) box appears. Modify the IP Address, subnet
mask and gateway accordingly then click OK button.

Figure 4-170 Routing Setting (Modify) Box

8. The Routing Setting box appears again. Confirm the route information
displayed.

NWD-107461-04E Operation
NE Setup 4-123

Figure 4-171 Routing Setting Box

9. Click OK button after configuring the parameters.

10. The Confirmation box appears. Click OK button.

Figure 4-172 Confirmation Box

11. The Information box appears. Click OK button.

Figure 4-173 Information Box

12. The Routing Setting window appears again. Confirm the route information
displayed.

Operation NWD-107461-04E
4-124 NE Setup

Figure 4-174 Routing Setting Window

13. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.

14. Confirm that the MAINT changes from yellow to white.

This step ends the procedure.

(c) Delete Routing Setting

Procedure 4-36

1. Click the Maintenance button on the top of the LCT window to turn on the
maintenance mode.

2. Expand Equipment Setup from the WebLCT menu.

3. Expand Network Management Configuration from the Equipment Setup


sub menu.

4. Select Routing Setting from the Network Management Configuration


sub menu.

5. The Routing Setting window appears. Click Setup button.

NWD-107461-04E Operation
NE Setup 4-125

Setup button

Figure 4-175 Routing Setting Window

6. The Routing Setting box appears. Click Delete button.

Delete button

Figure 4-176 Routing Setting Box

7. The Routing Setting (Delete) box appears. Enter the network address
displayed in the list, and then click OK button.

Operation NWD-107461-04E
4-126 NE Setup

Figure 4-177 Routing Setting (Delete) Box

8. The Routing Setting box appears again. Confirm that the specified network
has been deleted, then click OK button.

Figure 4-178 Routing Setting Box

9. The Confirmation box appears. Click OK button.

Figure 4-179 Confirmation Box

10. The Information box appears. Click OK button.

NWD-107461-04E Operation
NE Setup 4-127

Figure 4-180 Information Box

11. The Routing Setting window appears again. Confirm the route information
displayed.

Figure 4-181 Routing Setting Window

12. After finishing Routing Setting, click Maintenance button on the top of the
WebLCT window to exit maintenance mode.

13. Confirm that the MAINT changes from yellow to white.

This step ends the procedure.

Operation NWD-107461-04E
4-128 / END NE Setup

This page is intentionally left blank.

NWD-107461-04E Operation
System Operation 5-1

5. SYSTEM OPERATION

5.1 Provisioning
This setup is for further system fundamental configuration after the equipment setup.
The setting items are listed as follows:

z MODEM Function Setting

User can configure the port, radio switch, ATPC/MTPC power, E1/STM-1
threshold, and so on for each selected MODEM.

z ETH Function Setting

User can configure the Ethernet port, VLAN ETH OAM, RSTP, QOS, link loss
forwarding and so on.

z E1/STM-1/Cross Connect Setting

User can configure the E1 port/STM-1 port and cross connect.

z Equipment Clock/Synchronization Setting

User can configure the internal clock, external clock, timing source.

z V.11/OW Setting

User can configure the user interface of iPASOLINK 100/200 (V.11,RS-232C)


and OW buzzer.

z Alarm/AIS Setting

User can configure the alarm delay, severity, color and relevant settings of AIS.

z PMON/RMON Setting

User can configure the threshold of PMON (except Ethernet)/ RMON (Ethernet).

z AUX Setting

User can configure the relevant settings of the auxiliary (AUX).

For details, refer to the relevant sections accordingly.

Operation NWD-107461-04E
5-2 System Operation

5.1.1 MODEM Function Setting


User can configure the port, radio switch, ATPC/MTPC power, E1/STM-1 threshold,
and so on for each selected MODEM.

z MODEM Function Setting

Specify the port name of MODEM.

z Radio Switch Setting

Specify the TX/RX switch priority that prevents from unnecessary switching.

z TX Power Setting

Specify the threshold of TX power and RX power in MTPC/ATPC


configuration.

z ALM Mode Setting

Specify the ATPC power mode and ALM mode when ODU communication
fails.

z XPIC Setting (iPASOLINK 200)

Specify the XPIC Lo Condition operation mode.

z AMR Setting

Specify the AMR switching mode.

5.1.1.1 MODEM Port Setting

Specify the Port Name of MODEM.

Procedure 5-1

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select MODEM Port Setting from the MODEM Function Setting sub
menu.

4. The MODEM Port Setting window appears. Click the desired MODEM to
configure.

NWD-107461-04E Operation
System Operation 5-3

Figure 5-1 MODEM Port Setting Window

5. The MODEM Port Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-2 MODEM Port Setting Dialog Box

Table 5-1 MODEM Port Setting


Item Parameter Note
Port Name 0 to 32 Specify the port name of the
MODEM

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-3 Information Box

8. The MODEM Port Setting window appears again. Confirm the displayed
parameters.

Operation NWD-107461-04E
5-4 System Operation

Figure 5-4 MODEM Port Setting Window

This step ends the procedure.

5.1.1.2 Radio Switch Setting

Specify the TX/RX SW priority and TXSW lockin usage, and TX SW reverse
function usage.

The configurable items are listed as follows:

• TX SW Priority

Specify the TX switches priority in transmit direction. (Hot-standby System


only)

• TXSW Lockin Usage

This function is to prevent the TX switch from frequent switch over in case of
cable problem between IDU and ODU.

• TX SW Reverse Function Usage

This function is to enable TX switch in case the opposite station detects the TX
transmit trouble of local station.

• RX SW Priority

Specify the RX switches priority. (Hot-standby system and Twin-path system


only)

• RX SW Condition Early Warning

Select whether include this function.

NWD-107461-04E Operation
System Operation 5-5

Procedure 5-2

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select Radio Switch Setting from the MODEM Function Setting sub
menu.

4. The Radio Switch Setting window appears. Click the desired MODEM No.
(or SW GRP1) to configure.

SW GRP1.

Figure 5-5 Radio Switch Setting Window

5. The Radio Switch Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-6 Radio Switch Setting Dialog Box

Operation NWD-107461-04E
5-6 System Operation

Table 5-2 Radio Switch Setting


Item Parameter Description
TX SW Priority Non Priority Selecting non revertive mode
No.1 Select No.1 when both No.1 and No.2 are normally
operating.
TX SW Lockin Used Enable TX SW Lockin function
Usage Not Used Disable TX SW Lockin function
TX SW Reverse Used Enable Reverse Function
Function Usage Not Used Disable Reverse Function
RX SW Priority Non Priority Selecting non revertive mode
No.1 Select No.1 when both No.1 and No.2 are normally
operating.
RX SW Condition Included Early Include Early Warning in the switch factor by an
Early Warning Warning automatic switch.
Excluded Do not include Early Warning in the switch factor
Early Warning by an automatic switch.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-7 Information Box

8. The Radio Switch Setting window appears again. Confirm the displayed
parameters.

NWD-107461-04E Operation
System Operation 5-7

Figure 5-8 Radio Switch Setting Window

This step ends the procedure.

5.1.1.3 TX Power Setting

Specify the threshold of TX power and RX power in MTPC/ATPC configuration.

(1) ATPC Mode

Procedure 5-3

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select TX Power Setting from the MODEM Function Setting sub menu.

4. The TX Power Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.

Operation NWD-107461-04E
5-8 System Operation

Figure 5-9 TX Power Setting Window

5. The TX Power Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-10 TX Power Setting Dialog Box

Table 5-3 TX Power Setting


Item Parameter Description
ATPC Range (MAX) -30.5 to 0.0 dBm Set ODU maximum TX power level in ATPC
mode
ATPC Range (MIN) -30.5 to 0.0 dBm Set ODU minimum TX power level in ATPC mode
ATPC Hysteresis -30.5 to 0.0 dBm Set Hysteresis in ATPC mode
MTPC TX Power -30 to 0 dBm Not select
RX Threshold -95 - -30 dBm Set threshold of RX LEVEL in ATPC mode

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-9

Figure 5-11 Information Box

8. The TX Power Setting window appears again. Confirm the displayed


parameters.

Figure 5-12 TX Power Setting Window

This step ends the procedure.

(2) MTPC Mode

Procedure 5-4

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select TX Power Setting from the MODEM Function Setting sub menu.

4. The TX Power Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.

Operation NWD-107461-04E
5-10 System Operation

Figure 5-13 TX Power Setting Window

5. The TX Power Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-14 TX Power Setting Dialog Box

Table 5-4 TX Power Setting


Item Parameter Description
ATPC Range (MAX) -30.5 to 0.0 dBm Not select
ATPC Range (MIN) -30.5 to 0.0 dBm Not select
ATPC Hysteresis -30.5 to 0.0 dBm Not select
MTPC TX Power -30 to 0 dBm Set TX power level in MTPC mode
RX Threshold -95 to -30 dBm Set threshold of RX LEVEL in ATPC mode

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-11

Figure 5-15 Information Box

8. The TX Power Setting window appears again. Confirm the displayed


parameters.

Figure 5-16 TX Power Setting Window

This step ends the procedure.

5.1.1.4 ALM Mode Setting

Specify the ATPC power mode and ALM mode when ODU communication fails.

Procedure 5-5

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select ALM Mode Setting from the MODEM Function Setting sub menu.

4. The ALM Mode Setting window appears. Click the desired MODEM No. (or
SW GRP1) to configure.

Operation NWD-107461-04E
5-12 System Operation

Figure 5-17 ALM Mode Setting Window

5. The ALM Mode Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-18 ALM Mode Setting Dialog Box

Table 5-5 ALM Mode Setting


Item Parameter Description
ATPC Power Mode MAX Increase TX Power to Max. value
MIN Decrease TX Power to Min. value.
Hold Hold the current TX Power value.
ODU COMM ALM Mute Mute TX power when ODU communication
Mode failed
Hold Hold TX power when ODU communication
failed.

Note: In case user has selected MTPC, “ATPC Power Mode” will be Invalid.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-13

Figure 5-19 Information Box

8. The ALM Mode Setting window appears again. Confirm the displayed
parameters.

Figure 5-20 ALM Mode Setting Window

This step ends the procedure.

5.1.1.5 XPIC Setting (iPASOLINK 200)

Configure XPIC as follows:

Procedure 5-6

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select XPIC Setting from the MODEM Function Setting sub menu.

4. The XPIC Setting window appears. Click the XPIC GRP1 to configure.

Operation NWD-107461-04E
5-14 System Operation

XPIC GRP1

Figure 5-21 XPIC Setting Window

5. The XPIC Setting dialog box appears.

Figure 5-22 XPIC Setting Dialog Box

6. When the Lo signal to ODU from IDU becomes out of synchronization, either
ODU operation MUTE (default) or Self Lo (ODU self Lo operation) can be
selected

7. Click OK button after setting the parameter.

Figure 5-23 Information Box

8. The XPIC Setting window appears again.

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-15

5.1.1.6 AMR Setting

Configure AMR switch mode as follows:

Procedure 5-7

1. Expand Provisioning from the WebLCT menu.

2. Expand MODEM Function Setting from the Provisioning sub menu.

3. Select AMR Setting from the MODEM Function Setting sub menu.

4. The AMR Setting window appears.

Figure 5-24 AMR Setting Window

5. Click the MODEM Number to configure.

6. The AMR Setting dialog box appears. Assign a proper value for each parameter.

Operation NWD-107461-04E
5-16 System Operation

Figure 5-25 AMR Setting Window

Table 5-6 AMR Mode Setting


Item Parameter Description
AMR Switch CNR+RSL AMR Switching mode with CNR+RSL.
Condition CNR AMR Switching mode only with CNR.
When using this mode, AMR Range must be set as
continuously "Used" as following sample, 16QAM
to 64QAM setting.

7. Click OK button after setting the parameter.

Figure 5-26 Information Box

8. The AMR Setting window appears again.

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-17

5.1.2 ETH Function Setting


The ETH Function setting menu list is as follows:

z Bridge Setting
Bridge function also known as switching function that enable the device in the
multiple network segments can communicate with each other. User can
configure the FDB (forward database) aging time, default VLAN ID and VLAN
mode here.

z ETH Port Setting

This function provide user the abilities that configure the attributes of the
Ethernet port on the front panel of iPASOLINK, including port name, line speed,
Mode, Flow Control etc.

z VLAN Setting

VLAN (Virtual Local Area Network) enable multiple devices which separated
physically can communicate as they are located in a same broadcast domain and
also protect the data from send to other domain even they may connected
physically.

This function provide user the abilities of create, configure and delete the VLAN.

z FDB Setting

iPASOLINK can learn the MAC address of the Ethernet frame dynamically and
save the port – MAC address mapping information into FDB (Forwarding
DataBase) based on IEEE802.1d for each VLAN. User can also add the static
mapping information manually by this function.

z ETH OAM Setting

iPASOLINK support Ethernet OAM function based on ITU-T Y.1731 and


IEEE802.1ag, which enable operator to measure the Ethernet link quality such as
delay, throughput, jitter, loss and so on, greatly help network operator in
maintenance and troubleshooting.

z RSTP Setting

iPASOLINK supports RSTP (Rapid Spanning Tree Protocol) which prevent


from layer 2 level link loop with a faster manner compare to legacy STP
protocol.

User can set the priority of the bridge; specify the role of the Ethernet port and
other parameters.

Operation NWD-107461-04E
5-18 System Operation

z QoS/Classification Setting

iPASOLINK support QoS control function that provide different priority to


different applications, users, or data flow or to guarantee a certain level of
performance to a data flow. User can configure Class Classification, Ingress
Policer, Egress QoS and SP, TDM E1 QoS on MODEM to realize differential
service strategy.

z Other ETH Port Setting

This function provides additional setting of bridge such as Mirror port, layer 2
protocol transparency.

z LLF Setting

LLF (Link Loss Forwarding) is the function that mandatory shutdown the port on
the opposite device when local device detected unidirectional link problem.

z Broadcast Storm Control

This function discards flooding frames in a specific interface without transferring.


This function can set also flooding transferring control in unit of ETH port
including MODEM port. By specifying the bandwidth of broadcast frame,
multicast frame, and unknown address unicast frame collectively, frames beyond
the specified band are discarded at the circuit input.

5.1.2.1 Bridge Setting

Procedure 5-8

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select Bridge Setting from the ETH Function Setting sub menu.

4. The Bridge Setting window appears. Click Modify button.

NWD-107461-04E Operation
System Operation 5-19

Modify button

Figure 5-27 Bridge Setting Window

5. The Bridge Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-28 Bridge Setting Dialog Box

Table 5-7 Bridge Setting


Item Parameter Description
Aging On/Off On Enable/Disable aging the MAC address in the table.
Off
FDB Aging Time 5 to 163680 s Specify the aging time when Aging is enable.
GbE MAX Frame Size 64 to 9600 Byte Set the maximum frame size of GbE (Giga bit Ethernet)
FE MAX Frame Size 64 to 2000 Byte Set the maximum frame size of FE (Fast Ethernet)
VLAN Mode 802.1q 802.1q only
Default VID Default = 1 Specify the default VLAN ID of the equipment
1 to 4094
Default VLAN TPID 0x8100 Not selectable

Operation NWD-107461-04E
5-20 System Operation

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-29 Information Box

8. The Bridge Setting window appears again. Confirm the displayed parameters.

Figure 5-30 Bridge Setting Window

This step ends the procedure.

5.1.2.2 ETH Port Setting

Procedure 5-9

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH Port Setting from the ETH Function Setting sub menu.

4. The ETH Port Setting window appears. Click the desired Port No. to
configure.

NWD-107461-04E Operation
System Operation 5-21

Port No.

Figure 5-31 ETH Port Setting Window

5. The ETH Port Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-32 ETH Port Setting Dialog Box

Table 5-8 ETH Port Setting


Item Parameter Description
Port Usage Enable Turn on the port administratively
Disable Shutdown the port administratively
Port Name 1-32 Specify the name of the Ethernet port
Media Type Electrical Not selectable
Optical Not selectable
Speed AUTO Set the line speed of ETH port between
10MB 10 Mbit/s, 100 Mbit/s, or negotiate with the
100MB opposite side (AUTO negotiation).
*1
Duplex Half Specify the port work on half-duplex mode.

Operation NWD-107461-04E
5-22 System Operation

Full Specify the port work on full-duplex mode.


*1
MDI and MDIX MDI Select the Multiple Document Interface
MDIX Select the MDI Crossover
Flow Control Enable Enable flow control
Disable Disable flow control

*1 When AUTO of Speed is selected, Duplex and MDI and MDIX are not selectable.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-33 Information Box

8. The ETH Port Setting window appears again. Confirm the displayed
parameters.

Figure 5-34 ETH Port Setting Window

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-23

5.1.2.3 VLAN Setting

(1) VLAN List Tab

(a) Add VLAN ID

Procedure 5-10

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select VLAN Setting from the ETH Function Setting sub menu.

4. The VLAN Setting window appears. Click VLAN List tab.

VLAN List tab

Figure 5-35 VLAN Setting Window

5. The VALN List tab appears. Click Add VLAN ID button to create a new
VLAN ID.

Operation NWD-107461-04E
5-24 System Operation

VLAN ID button

Figure 5-36 VLAN List Tab

6. The Add VLAN ID dialog box appears. Refer to the table below to assign a
proper value for each parameter accordingly.

Figure 5-37 Add VLAN ID Dialog Box

Table 5-9 Add VLAN ID Parameter


Item Parameter Description
VLAN ID 1 to 4094 Specify VLAN ID
VALN Service Name 1 to 32 Character Specify the service name of the VLAN

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-25

Figure 5-38 Information Box

9. The VLAN Setting window appears again. Confirm the displayed parameters.

Figure 5-39 VLAN List Tab in the VLAN Setting Window

This step ends the procedure.

(b) Modify VLAN Service Name

Procedure 5-11

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select VLAN Setting from the ETH Function Setting sub menu.

4. The VLAN Setting window appears. Click VLAN List tab.

Operation NWD-107461-04E
5-26 System Operation

VLAN List tab

Figure 5-40 VALN Setting Window

5. The VALN List tab appears. Click the VLAN Service Name to be modified.

VLAN Service Name

Figure 5-41 VLAN List Tab

6. The Modify VLAN Service Name box appears. Modify the VLAN Service
Name accordingly.

NWD-107461-04E Operation
System Operation 5-27

Figure 5-42 Modify VLAN Service Name Box

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-43 Information Box

9. The VALN List tab appears again. Confirm the modified VLAN Service Name.

Figure 5-44 VLAN List Tab

This step ends the procedure.

Operation NWD-107461-04E
5-28 System Operation

(c) Delete VLAN ID

Procedure 5-12

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select VLAN Setting from the ETH Function Setting sub menu.

4. The VLAN Setting window appears. Click VLAN List tab.

VLAN List tab

Figure 5-45 VALN Setting Window

5. The VLAN List tab appears. Click Delete VLAN ID button.

NWD-107461-04E Operation
System Operation 5-29

Delete VLAN ID button

Figure 5-46 VLAN List Tab

6. The Delete VLAN ID box appears. Input the VLAN ID or VLAN Service Name
to be deleted.

Figure 5-47 Delete VLAN ID Box (1/2)

Figure 5-44 Delete VLAN ID Box (2/2)

7. Click OK button after setting the parameters.

8. The Confirmation box appears. Click OK button.

Operation NWD-107461-04E
5-30 System Operation

Figure 5-48 Confirmation Box

9. The Information box appears. Click OK button.

Figure 5-49 Information Box

10. The VLAN List tab appears again. Confirm the VLAN ID has been deleted.

Figure 5-50 VLAN List Tab

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-31

(2) VLAN Setting Tab

(a) Set VLAN ID

Procedure 5-13

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select VLAN Setting from the ETH Function Setting sub menu.

4. The VLAN Setting window appears. Click Port No. button.

Port No.

Figure 5-51 VLAN Setting Window

5. The VLAN Setting window appears. Assign a proper value for each VLAN
Assignment field parameter.

Note: The views are different according to the configuration (Access/ Tunnel/
Trunk).

Operation NWD-107461-04E
5-32 System Operation

• Access

Figure 5-52 VLAN Setting Window

• Tunnel

Figure 5-53 VLAN Setting Window

NWD-107461-04E Operation
System Operation 5-33

• Trunk

Figure 5-54 VLAN Setting Window

Table 5-10 VLAN Assignment Parameter


Item Parameter Description
Port Type Access Only Allow untagged frame pass through
Tunnel Allow tagged and untagged frame pass
through
Trunk Only allow tagged frame pass through
Enable check box Check Check the box to assign the port to the
Uncheck specified VLAN.
UntagFrame Assignment Check -
(Access Port) Uncheck

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-34 System Operation

Figure 5-55 Information Box

8. The VLAN Setting window appears again. Confirm the parameters displayed.

Figure 5-56 VLAN Setting Window

This step ends the procedure.

5.1.2.4 FDB Setting

(1) FDB Setting Tab

Procedure 5-14

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select FDB Port Setting from the ETH Function Setting sub menu.

4. The FDB Setting window appears. Click on the desired Equipment to


configure in the FDB Setting tab.

NWD-107461-04E Operation
System Operation 5-35

Equipment

Figure 5-57 FDB Setting Tab

5. The FDB Setting (Equipment) dialog box appears. Assign a proper value for
each parameter.

Figure 5-58 FDB Setting (Equipment) Dialog Box

Table 5-11 FDB Setting


Item Parameter Description
Learning MAX Size 1 to 32384 Set the learning MAX entries of MAC Address
Learning Limit Mode Forwarding Not selectable
Discard Not selectable
Learning Limit Trap Enable Enable equipment to send trap when the
learning MAC Address reach to the specified
MAX number.
Disable Disable above feature.

Operation NWD-107461-04E
5-36 System Operation

6. Click OK button after setting the parameters.

7. The FDB Setting tab appears again. Click the desired VLAN ID No. to
configure.

VLAN ID No.

Figure 5-59 FDB Setting Tab

8. The FDB Setting box appears. Assign a proper value for each parameter.

Figure 5-60 FDB Setting Box

Table 5-12 FDB Setting (VLAN ID)


Item Parameter Description
Learning MAX Size 0 to 32384 Set the learning MAX entries of MAC Address
Learning Limit Mode Forwarding Not selectable
Discard Not selectable

9. Click OK button after setting the parameters.

10. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-37

Figure 5-61 Information Box

11. The FDB Setting tab appears again. Confirm the displayed parameters.

Figure 5-62 FDB Setting Tab

This step ends the procedure.

(2) Static Entry Tab

(a) Add Static Entry

Procedure 5-15

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select FDB Port Setting from the ETH Function Setting sub menu.

4. The FDB Setting window appears. Click the Static Entry tab.

Operation NWD-107461-04E
5-38 System Operation

Static Entry tab

Figure 5-63 FDB Setting Window

5. The Static Entry tab appears. Click Add button.

Add button

Figure 5-64 Static Entry Tab

6. The Static Entry (Add) dialog box appears. Refer to the table below to assign
a proper value for each parameter accordingly.

NWD-107461-04E Operation
System Operation 5-39

Figure 5-65 Static Entry (Add) Dialog Box

Table 5-13 FDB Setting (Static Entry)


Item Parameter Description
Item Main Board Select the object from drop-down list.
MODEM1
MODEM2
Port Select the port from drop-down list.
MAC Address xx:xx:xx:xx:xx:xx Enter the object MAC address
Enable check box Check Check the box to assign the port to the
specified VLAN.
Uncheck Not assign the port to the VLAN.

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-66 Information Box

9. The Static Entry tab appears again. Confirm the displayed parameters.

Operation NWD-107461-04E
5-40 System Operation

Figure 5-67 Static Entry Tab

This step ends the procedure.

(b) Modify Static Entry

Procedure 5-16

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select FDB Port Setting from the ETH Function Setting sub menu.

4. The FDB Setting window appears. Click the Static Entry tab.

Static Entry tab

Figure 5-68 FDB Setting Window

NWD-107461-04E Operation
System Operation 5-41

5. The Static Entry tab appears. Click the desired Entry No. to configure.

Entry No.

Figure 5-69 Static Entry Tab

6. The Static Entry dialog box appears. Modify the MAC address accordingly.

Figure 5-70 Static Entry Dialog Box

7. Click OK button after setting the MAC address.

8. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-42 System Operation

Figure 5-71 Information Box

9. The Static Entry tab appears again. Confirm the modified parameters of the
MAC address.

Figure 5-72 Static Entry Tab

This step ends the procedure.

(c) Delete Static Entry

Procedure 5-17

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select FDB Port Setting from the ETH Function Setting sub menu.

4. The FDB Setting window appears. Click the Static Entry tab.

NWD-107461-04E Operation
System Operation 5-43

Static Entry tab

Figure 5-73 FDB Setting Window

5. The Static Entry tab appears. Click the Delete button.

Delete buton

Figure 5-74 Static Entry Tab

6. The Static Entry (Delete) dialog box appears. Check the static entry No. to
be deleted.

Operation NWD-107461-04E
5-44 System Operation

Figure 5-75 Static Entry (Delete) Dialog Box

7. Click OK button after setting the parameters.

8. The Confirmation box appears. Click OK button.

Figure 5-76 Confirmation Box

9. The Information box appears. Click OK button.

Figure 5-77 Information Box

10. The Static Entry tab appears again. Confirm the static entry No. has been
deleted.

NWD-107461-04E Operation
System Operation 5-45

Figure 5-78 Static Entry Tab

This step ends the procedure.

5.1.2.5 ETH OAM Setting

(1) OAM MEG Tab

(a) Add OAM MEG Index

Procedure 5-18

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the OAM MEG tab.

OAM MEG tab

Figure 5-79 ETH OAM Setting Window

Operation NWD-107461-04E
5-46 System Operation

5. The OAM MEG tab appears. Click the Add MEG button.

Figure 5-80 OAM MEG Tab

6. The OAM MEG Setting (Add) box appears. Refer to the table below to assign
a proper value for each parameter accordingly.

Figure 5-81 OAM MEG Setting (Add) Box

NWD-107461-04E Operation
System Operation 5-47

Table 5-14 MEG Configuration Parameter


Item Parameter Description
MEG Index 1 to 128 Specify MEG (Maintenance Entity
Group) Index
Maintenance String of a maximum of 43 Specify the Name of the Maintenance
Domain Name characters (Maintenance Domain
Short MA Name Domain Name + Short MA Specify the Short MA Name
Name)
MEG Level 0 to 7 Specify the Level of the MEG
CCM Enable Enable sending and monitoring CCM
Disable Disable sending and monitoring CCM
ETH-CC Period 3.3ms/10ms/100ms/1s/10s/60s Set the period of ETH-CC(Continuity
Check) message
CCM Priority 0 to 7 Specify the priority of the CCM

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-82 Information Box

9. The OAM MEG tab appears again. Confirm the newly added MEG Index
information displayed.

Operation NWD-107461-04E
5-48 System Operation

Figure 5-83 OAM MEG Tab

This step ends the procedure.

(b) Delete OAM MEG

Procedure 5-19

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the OAM MEG tab.

OAM MEG tab

Figure 5-84 ETH OAM Setting Window

5. The OAM MEG tab appears. Click the Delete MEG button.

NWD-107461-04E Operation
System Operation 5-49

OAM MEG tab

Figure 5-85 OAM MEG Tab

6. The OAM MEG Setting (Delete) box appears. Select the OAM MEG Index
No. to be deleted.

Figure 5-86 OAM MEG Setting (Delete) Box

7. Click OK button.

8. The Confirmation box appears. Click OK button.

Figure 5-87 Confirmation Box

9. The Information box appears. Click OK button.

Figure 5-88 Information Box

Operation NWD-107461-04E
5-50 System Operation

10. The OAM MEG tab appears again. Confirm the OAM MEG has been deleted.

Figure 5-89 OAM MEG Tab

This step ends the procedure.

(2) OAM MEP Tab

(a) Add OAM MEP Index

Procedure 5-20

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click Add MEP button in the OAM
MEP tab.
Add MEP button

Figure 5-90 OAM MEP Tab

5. The OAM MEP Setting (Add) dialog box appears. Select the Enable radio
button in the MEG Configuration field.

NWD-107461-04E Operation
System Operation 5-51

Enable radio button

Figure 5-91 OAM MEP Setting (Add) Dialog Box

6. Click Add Peer MEP button in the Peer MEP Configuration field.

Operation NWD-107461-04E
5-52 System Operation

Add Peer MEP button

Figure 5-92 OAM MEP Setting (Add) Dialog Box

7. The Peer MEP Add box appears. Input the Peer MEP ID.

Figure 5-93 Peer MEP Add Box

8. Click OK button after setting the parameters.

9. The OAM MEP Setting (Add) dialog box appears again. Refer to the table
below to assign a proper value for each parameter accordingly.

NWD-107461-04E Operation
System Operation 5-53

Figure 5-94 OAM MEP Setting (Add) Dialog Box

Operation NWD-107461-04E
5-54 System Operation

Table 5-15 MEP Configuration field Parameter


Item Parameter Description
Peer MEP Add
Peer MEP ID 1 to 8191 Specify the MEP (MEG End Point) ID of the
peer equipment
MEP Configuration
MEP Index 1 to 128 Specify the local MEP Index
MEP ID 1 to 8191 specify the ID of the MEG Index
Item Main Board Select the object item from drop-down list
MODEM1
MODEM2
Port Select the port from drop-down list
Assignment VLAN Check Check the box of the VLAN ID to associate
ID List MEP to the VLAN.
Uncheck Not associate the MEP to the VLAN ID.
MEG Configuration
Enable radio Check Check the button of the MEG Index to
button associate MEG Configuration
Uncheck Not associate the MEP to the MEG
Configuration.

10. Click OK button after setting the parameters.

11. The Confirmation box appears. Click OK button.

Figure 5-95 Confirmation Box

12. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-55

Figure 5-96 Information Box

13. The OAM MEP tab appears again. Confirm the newly added MEP Index
information displayed.

Figure 5-97 OAM MEP Tab

This step ends the procedure.

(b) Modify OAM MEP Index

Procedure 5-21

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the MEP Index No. to be
modified in the OAM MEP tab.

Operation NWD-107461-04E
5-56 System Operation

Figure 5-98 OAM MEP Tab

5. The OAM MEP Setting (Modify) dialog box appears. Modify the parameter
accordingly.

Figure 5-99 OAM MEP Setting (Modify) Dialog Box

NWD-107461-04E Operation
System Operation 5-57

Table 5-16 OAM MEP Index Parameter


Item Parameter Description
Peer MEP Add
Peer MEP ID 1 to 8191 Specify the MEP (MEG End Point) ID of
the peer equipment
MEP Configuration
MEP Index 1 to 128 Specify the Number of the MEP Index
MEP ID 1 to 8191 Specify the ID of the MEP Index
Item Main Board Select the object item from drop-down list
MODEM1
MODEM2
Port Select the object port from drop-down list
Assignment VLAN ID check Check the box of the VLAN ID to
List associate MEP to the VLAN.
uncheck Not associate the MEP to the VLAN ID.
MEG Configuration
Enable Check box Check Check the box of the MEG Index to
associate MEG Configuration
Uncheck Not associate the MEP to the MEG
Configuration.

6. Click OK button after setting the parameters.

7. The Confirmation box appears. Click OK button.

Operation NWD-107461-04E
5-58 System Operation

Figure 5-100 Confirmation Box

8. The Information box appears. Click OK button.

Figure 5-101 Information Window

9. The OAM MEP tab appears again. Confirm the modified parameters of the
OAM MEP Index information displayed.

Figure 5-102 OAM MEP Tab

This step ends the procedure.

(c) Delete OAM MEP

Procedure 5-22

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

NWD-107461-04E Operation
System Operation 5-59

4. The ETH OAM Setting window appears. Click Delete MEP button in the
OAM MEP tab.

Figure 5-103 OAM MEP Tab

5. The OAM MEP Setting (Delete) box appears. Select the OAM MEP Index No.
to be deleted.

Figure 5-104 OAM MEP Setting (Delete) Box

6. Click OK button.

7. The Confirmation box appears. Click OK button.

Figure 5-105 Confirmation Box

8. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-60 System Operation

Figure 5-106 Information Box

Note: In case that CCM Transmit / CCM Receive is enabled, if user try to
delete the MEP Index the following error message will appears:

Follow the procedure of (2) Modify OAM MEP Index, disable CCM
Transmit / CCM Receive first and then delete the MEP Index.

9. The OAM MEP tab appears again. Confirm the OAM MEP has been deleted.

Figure 5-107 OAM MEP Tab

This step ends the procedure.

(3) OAM MIP Tab

(a) Add OAM MIP

Procedure 5-23

1. Expand Provisioning from the WebLCT menu.

NWD-107461-04E Operation
System Operation 5-61

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the OAM MIP tab.

OAM MIP tab

Figure 5-108 ETH OAM Setting Window

5. The OAM MIP tab appears. Click Add MIP button.

Add MIP button

Figure 5-109 OAM MIP Tab

6. The OAM MIP Setting (Add) box appears. Refer to the table below to assign a
proper value for each parameter accordingly.

Operation NWD-107461-04E
5-62 System Operation

Figure 5-110 OAM MIP Setting (Add) Box

Table 5-17 OAM MIP Index Parameter


Item Parameter Description
MIP Index 1 to 32 Specify the MIP (MEG Intermediate Point)
Index
MEG Level 0 to 7 Specify the MEG level for the MIP
Item Main Board Select the object item from drop-down list
MODEM1
MODEM2
Port Select the object port from drop-down list
Assignment VLAN ID Check Check the box of the VLAN ID to
List associate MEP to the VLAN.
Uncheck Not associate the MEP to the VLAN ID.

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-63

Figure 5-111 Information Box

9. The OAM MIP tab appears again. Confirm the newly added OAM MIP
information displayed.

Figure 5-112 OAM MIP Tab

This step ends the procedure.

(b) Modify OAM MIP Index

Procedure 5-24

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the OAM MIP tab.

Operation NWD-107461-04E
5-64 System Operation

Figure 5-113 ETH OAM Setting Window

5. The OAM MIP tab appears. Click the desired MIP Index No. to configure.

MIP Index No.

Figure 5-114 OAM MIP Tab

6. The OAM MIP Setting (Modify) box appears. Modify the parameter
accordingly.

Figure 5-115 OAM MIP Setting (Modify) Box

NWD-107461-04E Operation
System Operation 5-65

Table 5-18 OAM MIP Index Parameter


Item Parameter Description
MIP Index 1 to 32 Specify the MIP Index
MEG Level 0 to 7 Specify the MEG level for the MIP
Item Main Board Select the object from drop-down list
MODEM1
MODEM2
Port Select the port from drop-down list
Assignment VLAN ID Check Check the box of the VLAN ID to
List associate MEP to the VLAN.
Uncheck Not associate the MEP to the VLAN ID.

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-116 Information Box

9. The OAM MIP tab appears again. Confirm the modified parameters of the OAM
MIP information displayed.

Figure 5-117 OAM MIP Tab

This step ends the procedure.

Operation NWD-107461-04E
5-66 System Operation

(c) Delete OAM MIP Index

Procedure 5-25

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select ETH OAM Setting from the ETH Function Setting sub menu.

4. The ETH OAM Setting window appears. Click the OAM MIP tab.

OAM MIP tab

Figure 5-118 ETH OAM Setting Window

5. The OAM MIP tab appears. Click Delete MIP button.

Delete MIP button

Figure 5-119 OAM MIP Tab

6. The OAM MIP Setting (Delete) box appears. Select the OAM MIP Index No.
to be deleted.

NWD-107461-04E Operation
System Operation 5-67

Figure 5-120 OAM MIP Setting (Delete) Box

7. Click OK button.

8. The Confirmation box appears. Click OK button.

Figure 5-121 Confirmation Box

9. The Information box appears. Click OK button.

Figure 5-122 Information Box

10. The OAM MIP tab appears again. Confirm the OAM MIP Index has been
deleted.

Operation NWD-107461-04E
5-68 System Operation

Figure 5-123 OAM MIP Tab

This step ends the procedure.

5.1.2.6 RSTP Setting

Note STP/RSTP tunnel enable function is not supported for RSTP enabled
port.

(1) Modify RSTP PORT

Procedure 5-26

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select RSTP Setting from the ETH Function Setting sub menu.

4. The RSTP Setting window appears. Click Modify RSTP Port button.

NWD-107461-04E Operation
System Operation 5-69

Modify RSTP Port button

Figure 5-124 RSTP Setting Window

5. The RSTP Port Setting window appears. Assign a proper value for each
parameter.

Figure 5-125 RSTP Port Setting Window

Operation NWD-107461-04E
5-70 System Operation

Table 5-19 RSTP Port Setting


Item Parameter Description
STP Mode RSTP Enable RSTP (Rapid Spanning Tree
Protocol) with RSTP/STP bilingual mode.
Disable Disable RSTP
STP Port Path Cost Auto Enable equipment calculate the path cost
automatically.
Manual Enter the path cost manually.
STP Port Path Cost 1 to 200000000 Enter the cost of path when Path Cost is
(Value) set to Manual
STP Port Priority 0 to 240 Specify the RSTP priority of the port
Edge Port Enable Set the Port as Edge port
Disable Remove Edge port feature
P-to-P Port Force true Enable Point-to-point
Force False Disable Point-to-point
Auto Set Point-to-point automatically

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-126 Information Box

8. The RSTP Setting window appears again. Confirm the parameters displayed.

NWD-107461-04E Operation
System Operation 5-71

Figure 5-127 RSTP Setting Window

This step ends the procedure.

(2) Modify Detail RSTP Parameter

Procedure 5-27

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select RSTP Setting from the ETH Function Setting sub menu.

4. The RSTP Setting window appears. Click Modify Detail RSTP Parameter
button.

Operation NWD-107461-04E
5-72 System Operation

Modify Detail RSTP Parameter button

Figure 5-128 RSTP Setting Window

5. The Detail RSTP Parameter Setting box appears. Assign a proper value for
each parameter.

Figure 5-129 Detail RSTP Parameter Setting Box

NWD-107461-04E Operation
System Operation 5-73

Table 5-20 Detail RSTP Parameter


Item Parameter Description
Bridge Priority 0 to 61440 Set STP priority of the bridge
STP Bridge MAX Age 6 to 40 s Set the expiration of the Configuration BPDU
stored, Bridge will. notice that a topology
change has occurred after the Max Age time
elapses and the BPDU is aged out
STP Bridge Hello Time 1s Set the period of sending Configuration
2s BPDUs from Root Bridge.
STP Bridge Forward 4 to 30 s Set the delay when the port is going to change
Delay the state from Listening to Learning.
STP TX Hold Count 1 to 10 Set the number of BPDU which can be sent
per second.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-130 Information Box

8. The RSTP Setting window appears again. Confirm the parameters displayed.

Operation NWD-107461-04E
5-74 System Operation

Figure 5-131 RSTP Setting Window

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-75

5.1.2.7 QoS/Classification Setting

z Classify Setting tab

iPASOLINK supports QoS based on MEF10 and REC4115 which classify the
traffic into eight classes with the proper Internal Priority according to the
predetermined Policer. Except the default Policer, user can configure up to three
additional Policer which provide user the capability of realizing the
user-orientation QoS strategy flexibly. The Internal Priority is used for following
purpose:

1) Indentify Ingress traffic properly according to the predetermined Policer.

2) Mapping the eight classes of ingress traffic to four classes when queueing the
Egress traffic.

3) Copy the original internal priority to the capsulated frame to prevent the
traffic priority from changing unexpectedly. (VLAN c-tag CoS/VLAN s-tag
CoS)

Two modes are available for QoS Classification.

1) Equipment Based QoS Mode (default)


QoS classification policies are determined by per-equipment basis. One
classification profile is activated, and up to three profiles are stored on the
equipment configuration. In this mode, most outer QoS field of the packet
can be specified for the classification policy.

2) Port Base QoS Mode


QoS classification policies are determined by per-port basis. In this mode,
inner QoS field of the packet can be specified for the classification policy.

z Ingress

At the Ingress of the traffic, assign the internal priority and then perform flow
control according to the predetermined policer, coloring the frame with Yellow
or Green which decide the QoS queue at the egress, discarding the frames of the
traffic that exceed the designated bandwidth (EIR, Excess Information Rate).

z Egress

Queueing the frame according to the internal priority and the color assigned at
ingress, determine forwarding or discarding the frame.

Operation NWD-107461-04E
5-76 System Operation

(1) Classify Setting Tab [Equipment Based QoS Mode]

(a) Classification Mode Setting

Procedure 5-28

9. Expand Provisioning from the WebLCT menu.

10. Expand ETH Function Setting from the Provisioning sub menu.

11. Select QoS/Classification Setting from the ETH Function Setting sub
menu.

12. The QoS/Classification Setting window appears. Click the Classification


Mode button
Classification Mode button

Figure 5-132 QoS/Classification Setting Window

13. The Classification Mode window appears. Select the Equipment Based
QoS Mode

Figure 5-133 Classification Mode Window

NWD-107461-04E Operation
System Operation 5-77

14. The Information box appears. Click OK button.

Figure 5-134 Information Box

15. The QoS/Classification Setting window appears again. Confirm the


parameters displayed.

This step ends the procedure.

(b) Classify Entry Setting

Procedure 5-29

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Select the object from


Classify Profile No. drop-down list.

Classify Profile No. drop-down list

Figure 5-135 QoS/Classification Setting Window

Operation NWD-107461-04E
5-78 System Operation

5. The QoS/Classification Setting window appears again. Click the desired


Entry No. to configure.

Entry No.

Figure 5-136 QoS/Classification Setting Window

6. The Classify Entry Setting box appears. Assign a proper value for each
parameter.

Figure 5-137 Classify Entry Setting Box

NWD-107461-04E Operation
System Operation 5-79

Table 5-21 Classify Entry Setting Parameter


Item Parameter Description
Classify Field type VLAN Cos Select the object from drop-down list
IPv4 Precedence
IPv4 DSCP
IPv6 DSCP
other
Classify Priority 0 to 7 Specify the Classify priority
Classify Internal 0 to 7 Select the Classify internal priority from
Priority drop-down list.

7. The Information box appears. Click OK button.

Figure 5-138 Information Box

8. The QoS/Classification Setting window appears again. Confirm the


parameters displayed.

Figure 5-139 QoS/Classification Setting Window

This step ends the procedure.

Operation NWD-107461-04E
5-80 System Operation

(c) Delete Entry

Procedure 5-30

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Select the object from


Classify Profile No. drop-down list.

Classify Profile No. drop-down list

Figure 5-140 QoS/Classification Setting Window

5. The QoS/Classification Setting window appears again. Click Delete Entry


button.

NWD-107461-04E Operation
System Operation 5-81

Delete Entry button

Figure 5-141 QoS/Classification Setting Window

6. The Delete Entry box appears. Assign a proper value for each parameter and
then click OK button.

Figure 5-142 Delete Entry Box

7. The Confirmation box appears. Click OK button.

Figure 5-143 Confirmation Box

8. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-82 System Operation

Figure 5-144 Information Box

9. The QoS/Classification Setting window appears again. Confirm the


parameters displayed.

Figure 5-145 QoS/Classification Setting Window

This step ends the procedure.

(d) Select Profile No.

Procedure 5-31

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

NWD-107461-04E Operation
System Operation 5-83

4. The QoS/Classification Setting window appears. Click the desired Select


Profile No. button to configure.
Select Profile No. button

Figure 5-146 QoS/Classification Setting Window

5. The Select profile No. box appears. Assign a proper value for drop-down list.

Figure 5-147 Select Profile No. Box

6. The Information box appears. Click OK button.

Figure 5-148 Information Box

7. The QoS/Classification Setting window appears. Confirm the parameters


displayed.

Operation NWD-107461-04E
5-84 System Operation

Figure 5-149 QoS/Classification Setting Window

This step ends the procedure.

(2) Classify Setting Tab [Port Based QoS Mode]

(a) Classification Mode Setting

Procedure 5-32

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub menu.

4. The QoS/Classification Setting window appears. Click the Classification


Mode button

NWD-107461-04E Operation
System Operation 5-85

Classification Mode button

Figure 5-150 QoS/Classification Setting Window

5. The Classification Mode window appears. Select the Port Based QoS
Mode

Figure 5-151 Classification Mode Window

6. The Information box appears. Click OK button.

Figure 5-152 Information Box

7. The QoS/Classification Setting window appears again. Confirm the


parameters displayed.

This step ends the procedure.

Operation NWD-107461-04E
5-86 System Operation

(b) Port Classification Mode Setting

Procedure 5-33

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click the Port button


Port button

Figure 5-153 QoS/Classification Setting Window

5. The Port Classification Mode Setting window appears. Select the object
from Port Classification Mode drop-down list and Assign a proper value for
Default Port Priority.

Figure 5-154 Port Classification Mode Setting Window

NWD-107461-04E Operation
System Operation 5-87

Table 5-22 Port Classification Mode Setting Parameter


Item Parameter Description
Port Classification Port Select the object from drop-down list
Mode CoS(C-Tag) - CoS(C-Tag): use CoS as the internal
IPv4 /v6 DSCP priority
- IPv4 /v6 DSCP: use DSCP as the
internal priority. DSCP is used even if a
frame has VLAN tag
- Port: Default priority of the port. This
value is used for access VLAN port, and
default value when specified DSCP filed is
not exist in the frame in the IPv4 /v6
DSCP mode.
Default Port Priority 0 to 7 Select the default priority for the port

6. The Information box appears. Click OK button.

Figure 5-155 Information Box

(3) Ingress Setting Tab

(a) Add Policer Index

Procedure 5-34

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click Ingress Setting


tab.

Operation NWD-107461-04E
5-88 System Operation

Ingress Setting tab

Figure 5-156 Classify Setting Window

5. The Ingress Setting tab appears. Click the Add Policer Index button.

Add Policer Index button

Figure 5-157 Ingress Setting Tab

6. The Add Policer Index box appears. Assign a proper value for each parameter.

NWD-107461-04E Operation
System Operation 5-89

Figure 5-158 Add Policer Index Box

Table 5-23 Ingress Policer Index Parameter


Item Parameter Description
Item Main Board Select the object from drop-down list
MODEM1
MODEM2
Port Specify the port from drop-down list.
Internal Priority 0 to 7 Specify the internal priority
Policer Profile No. 1 to 16 Specify the Policer Profile number that will
be applied on the port.
VLAN ID Check Enable Policer on the checked VLAN.
Uncheck -

7. Click the Policer Profile Detail button.

8. The Ingress Policer Profile Detail Setting box appears. Assign a proper
value for each parameter

Operation NWD-107461-04E
5-90 System Operation

Figure 5-159 Ingress Policer Profile Detail Setting Box

Table 5-24 Ingress Policer Profile Detail Parameter


Item Parameter Description
Classify Eir 0 to 1000000 kbps Set the available maximum bandwidth
Classify Cir 0 to 1000000 kbps Set the minimum guaranteed bandwidth
Classify Ebs 0 to 128 kbyte Specify the maximum Burst size.
Classify Cbs 1 to 64 kbyte Specify the minimum Burst size.

Note You need to set Ebs value bigger than MTU size of the policer applying
port.

9. Click OK button after setting the parameters.

10. The Information box appears. Click OK button.

Figure 5-160 Information Box

11. The Add Policer Index box appears again. Click OK Button.

NWD-107461-04E Operation
System Operation 5-91

Figure 5-161 Add Policer Index Box

12. The Information box appears. Click OK button.

Figure 5-162 Information Box

13. The Ingress Setting tab appears again. Confirm the newly added Ingress
Policer Index information displayed

Operation NWD-107461-04E
5-92 System Operation

Figure 5-163 Ingress Setting Tab

This step ends the procedure.

(b) Ingress Policer Profile Detail Setting

Procedure 5-35

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click Ingress Setting


tab.

NWD-107461-04E Operation
System Operation 5-93

Figure 5-164 QoS/Classification Setting Window

5. The Ingress Setting tab appears. Click the Ingress Policer Profile Setting
button.

Ingress Policer Profile Setting button

Figure 5-165 Ingress Setting Tab

6. The Ingress Policer Profile Setting box appears. Click the desired Ingress
Policer Index No. to configure.

Operation NWD-107461-04E
5-94 System Operation

Ingress Policer Index No.

Figure 5-166 Ingress Policer Profile Setting Box

7. The Ingress Policer Profile Detail Setting box appears. Assign a proper
value for each parameter

Figure 5-167 Ingress Policer Profile Detail Setting Box

Table 5-25 Ingress Policer Profile Detail Setting Parameter


Item Parameter Description
Classify Eir 0 to 1000000 (kbps) Set the available maximum bandwidth
Classify Cir 0 to 1000000 (kbps) Set the minimum guaranteed bandwidth
Classify Ebs 0 to 128 (kbyte) Specify the maximum Burst size.
Classify Cbs 1 to 64 (kbyte) Specify the minimum Burst size.

8. Click OK button after setting the parameters.

9. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-95

Figure 5-168 Information Box

10. The Ingress Policer Profile Setting box appears again. Click Close button.

Figure 5-169 Ingress Policer Profile Setting Box

11. The Ingress Setting tab appears again. Confirm the parameters displayed.

Operation NWD-107461-04E
5-96 System Operation

Figure 5-170 Ingress Setting Tab

This step ends the procedure.

(c) Modify Policer Index

Procedure 5-36

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click Ingress Setting


tab.

NWD-107461-04E Operation
System Operation 5-97

Ingress Setting tab

Figure 5-171 QoS/Classification Setting Window

5. The Ingress Setting tab appears. Click the desired Pollcer Index No to
configure.

Pollcer Index No

Figure 5-172 Ingress Setting Tab

6. The Ingress Policer Setting box appears. Modify the parameter accordingly.

Operation NWD-107461-04E
5-98 System Operation

Figure 5-173 Ingress Policer Setting Box

Table 5-26 Ingress Policer Index Parameter


Item Parameter Description
Internal Priority 0 to 7 Specify the internal priority
Policer Profile No 1 to 16 Specify the Policer Profile number which
will be applied on the port.
VLAN ID Check Enable Policer on the checked VLAN.
Uncheck -

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-174 Information Box

9. The Ingress Setting tab appears again. Confirm the modified parameters of
the Ingress Policer Index information displayed.

NWD-107461-04E Operation
System Operation 5-99

Figure 5-175 Ingress Setting Tab

This step ends the procedure.

(d) Delete Ingress Policer Index

Procedure 5-37

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click Ingress Setting


tab.

Operation NWD-107461-04E
5-100 System Operation

Ingress Setting tab

Figure 5-176 QoS/Classification Setting Window

5. The Ingress Setting tab appears. Click Delete Policer Index button.

Delete Policer Index button

Figure 5-177 Ingress Setting Tab

6. The Delete Policer Index box appears. Input the Ingress Pollcer Index No.
to be deleted.

NWD-107461-04E Operation
System Operation 5-101

Figure 5-178 Delete Policer Index Box

7. Click OK button.

8. The Confirmation box appears. Click OK button.

Figure 5-179 Confirmation Box

9. The Information box appears. Click OK button.

Figure 5-180 Information Box

10. The Ingress Setting tab appears again. Confirm the Ingress Policer Index
No. has been deleted

Operation NWD-107461-04E
5-102 System Operation

Figure 5-181 Ingress Setting Tab

This step ends the procedure.

(4) Port Setting Tab

Procedure 5-38

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select QoS/Classification Setting from the ETH Function Setting sub


menu.

4. The QoS/Classification Setting window appears. Click Port Setting tab.

NWD-107461-04E Operation
System Operation 5-103

Port Setting tab

Figure 5-182 QoS/Classification Setting Window

5. The Port Setting tab appears. Click the desired Main Board or MODEM
Port No. to configure.

Main Board or MODEM Port No.

Figure 5-183 Port Setting Tab

6. The Qos Port Setting box appears. Assign a proper value for each parameter.

Operation NWD-107461-04E
5-104 System Operation

Class No.

Figure 5-184 Qos Port Setting Box

7. Click the desired Class No. of the Egress Class Setting Information field.

8. The Egress Class Setting box appears. Assign a proper value for each
parameter.

Figure 5-185 Egress Class Setting Box

NWD-107461-04E Operation
System Operation 5-105

Table 5-27 Port Setting


Item Parameter Description
Qos Port Setting Information
Scheduling Mode 4xSP Specify the queueing mode.
1xSP+3xDWRR SP: Strict-Priority
4xDWRR DWRR: Deficit Weighted Round Robin
Port Drop Mode WTD Specify the port discard all packets at the
tail end of the queue when queue
exceeded the pre set threshold. WTD
(Weighted tail drop).
WRED Specify the port randomly discard the
packets of lower priority traffic before
higher priority traffic when queue
exceeded the preset threshold. WRED
(weighted random early detection).
Egress Shaper Rate 1 to 1000 Mbps Specify the maximum transmit rate of the
port.
Internal Priority Queueing Policy per Ingress Port
Internal Priority 0 to 7 0 to 3 Specify the egress queue(0 to 3) for each
Class internal priority values. Egress queueing
policy is determined with the policy.
Egress Class Setting Information
Class Shaper Rate 0.001 to 1000 Specify the maximum sending rate of the
Mbps class(queue). This value works with
“Egress Shaper Rate” as hierarchical
shaping function.
Class DWRR Weight 1 to 127 Specify the weight of the queue.
Class Queue Length 16 to 128 Kbyte Specify the length for each Queue.
(default: 64Kbyte)
Wtd Yellow Frame 10 to 100 % Set the discard Threshold of Yellow
Threshold Frames which are colored with ingress
policer and not applied with ingress
policer. When total queued frames length
exceeds the threshold due to traffic
congestion, arrived yellow frames are
discarded. (default: 70%)
Green frame discard threshold is fixed to
100%

Operation NWD-107461-04E
5-106 System Operation

Class 3

SP
DWRR

WTD Yellow Frame Clas s 0


Threshold (default 70%)

Queue Length (16-128Kbyte)

Figure 5-186 Egress Queue (1xSP+3xDWRR)

9. Click OK button after setting the parameters.

10. The Information box appears. Click OK button.

Figure 5-187 Information Box

11. The Qos Port Setting box appears again. Click OK button after setting the
parameters.

NWD-107461-04E Operation
System Operation 5-107

Figure 5-188 Qos Port Setting Box

12. The Information box appears. Click OK button.

Figure 5-189 Information Box

13. The Port Setting tab appears again. Confirm the parameters displayed.

Operation NWD-107461-04E
5-108 System Operation

Figure 5-190 Port Setting Tab

This step ends the procedure.

5.1.2.8 Other ETH Port Setting

Procedure 5-39

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select Other ETH Port Setting from the ETH Function Setting sub menu.

4. The Other ETH Port Setting window appears. Click the desired Port No to
configure.
Port No.

Figure 5-191 Other ETH Port Setting Window

NWD-107461-04E Operation
System Operation 5-109

5. The Other ETH Port Setting box appears. Assign a proper value for each
parameter.

Figure 5-192 Other ETH Port Setting Box

Table 5-28 Other ETH Port Setting


Item Parameter Description
Port Information
Monitoring Disable Set to Monitor the Disable
Monitoring Set to Monitor the port traffic
Mirror Set the port as Mirror port, the traffic of the
monitored port will be duplicated to this
port.
Monitoring Direction Ingress Specify to monitor the ingress traffic of the
port
Egress Specify to monitor the egress traffic of the
port
Both Specify to monitor the traffic of both
ingress and egress.
L2 Protocol Transparency
Tunnel Enable Check Check the box of the protocol to enable
the PDU of the protocol transparent
without processed.
Uncheck -

Operation NWD-107461-04E
5-110 System Operation

Note STP/RSTP tunnel enable function is not supported for RSTP enabled
port.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-193 Information Box

8. The Other ETH Port window appears again. Confirm the parameters displayed.

Figure 5-194 Other ETH Port Window

This step ends the procedure.

5.1.2.9 LLF Setting

(a) Add LLF GRP

Procedure 5-40

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select LLF Setting from the ETH Function Setting sub menu.

NWD-107461-04E Operation
System Operation 5-111

4. The LLF Setting window appears. Click Add LLF button.

Add LLF button

Figure 5-195 LLF Setting Window

5. The LLF Setting (Add) box appears. Refer to the table below to assign a
proper value for each parameter accordingly

Figure 5-196 LLF Setting (Add) Box

Operation NWD-107461-04E
5-112 System Operation

Table 5-29 LLF Setting Parameter


Item Parameter Description
LLF GRP ID 1 to 16 Select the LLF RGP ID Number
Item MODEM1 Select the object item form drop-down list.
MODEM2
Send LLF Signal Enable Enable sending LLF signal
Disable Disable sending LLF signal
Ignore Received LLF Enable Ignore received LLF signal.
Signal Disable Accept received LLF signal
Edge Port Setting Check Set the port as Edge port
Uncheck Unset the port as Edge port

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-197 Information Box

8. The LLF Setting window appears again. Confirm the newly added LLF Setting
information displayed.

Figure 5-198 LLF Setting Window

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-113

(b) Modify LLF GRP

Procedure 5-41

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select LLF Setting from the ETH Function Setting sub menu.

4. The LLF Setting window appears. Click the desired LLF GRP No. to
configure.

LLF GRP No.

Figure 5-199 LLF Setting Window

5. The LLF Setting (Modify) box appears. Modify the parameter accordingly.

Operation NWD-107461-04E
5-114 System Operation

Figure 5-200 LLF Setting (Modify) Box

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-201 Information Box

8. The LLF Setting window appears again. Confirm the modified parameters of
the LLF GRP information displayed.

NWD-107461-04E Operation
System Operation 5-115

Figure 5-202 LLF Setting Window

This step ends the procedure.

(c) Delete LLF GRP

Procedure 5-42

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select LLF Setting from the ETH Function Setting sub menu.

4. The LLF Setting window appears. Click Delete LLF button.

Delete LLF button

Figure 5-203 LLF Setting Window

5. The LLF Setting (Delete) box appears. Select the LLF GRP ID to be deleted.

Operation NWD-107461-04E
5-116 System Operation

Figure 5-204 LLF Setting (Delete) Box

6. Click OK button after setting the parameters.

7. The Confirmation box appears. Click OK button.

Figure 5-205 Confirmation Box

8. The Information box appears. Click OK button.

Figure 5-206 Information Box

9. The LLF Setting window appears again. Confirm the LLF GRP has been
deleted.

NWD-107461-04E Operation
System Operation 5-117

Figure 5-207 LLF Setting Window

This step ends the procedure.

5.1.2.10 Broadcast Storm Control Rate Setting

Procedure 5-43

1. Expand Provisioning from the WebLCT menu.

2. Expand ETH Function Setting from the Provisioning sub menu.

3. Select Broadcast Storm Control from the ETH Function Setting sub
menu.

4. The Broadcast Storm Control Setting window appears. Click Broadcast


Storm Control Rate button.

Operation NWD-107461-04E
5-118 System Operation

Broadcast Storm Control Rate button

Figure 5-208 Broadcast Storm Control Setting Window

5. The Broadcast Storm Control Rate dialog box appears. Enter storm control
rate 1 to 1000 Mbps.

Figure 5-209 Broadcast Storm Control Rate Dialog Box

6. Click OK button. The Broadcast Storm Control Rate dialog box closes. The
entered rate is indicated at the right field of the Broadcast Storm Control
Rate button.

7. Click Port No at the Item/Port Information for Main Board or MODEM1/2. The
Broadcast Storm Control (Main Board – Port-0x) or (MODEM –
Port-0x) dialog box appears.

8. Click Enable radio button to enable broadcast storm control function.

NWD-107461-04E Operation
System Operation 5-119

Figure 5-210 Broadcast Storm Control Rate Dialog Box (Main Board)

Figure 5-211 Broadcast Storm Control Rate Dialog Box (MODEM)

9. Click OK button. The dialog box closes, and the Broadcast Storm Control
Setting window appears again.

This step ends the procedure.

Operation NWD-107461-04E
5-120 System Operation

5.1.3 Cross Connect Setting


User can configure the E1 port/STM-1 port and cross connect.

The E1/STM-1/Cross Connect Setting menu list is as follows:

• E1 Port Setting

Configure E1 Port Name and E1 CH usage, Channel Impedance, reporting


unused CH.

• STM-1 Port Setting

Configure the STM-1 Port Mode, Usage, AIS generation, ALS (Automatic Laser
Shutdown) and tree setting.

• Cross Connect Setting

Configure Cross Connect, and confirm current Cross Connect and Port (CH)
utilization.

5.1.3.1 E1 Port Setting

Configure E1 port name, E1 CH usage, channel impedance, and unused CH report.

Procedure 5-44

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select E1 Port Setting from the E1/STM-1/Cross Connect Setting sub


menu.

4. The E1 Port Setting window appears. Click Modify button.

NWD-107461-04E Operation
System Operation 5-121

Modify button

Figure 5-212 E1 Port Setting Window

5. The E1 Port Setting (Main Board) dialog box appears. Refer to the table
below to assign a proper value for each parameter.

Operation NWD-107461-04E
5-122 System Operation

Figure 5-213 E1 Port Setting (Main Board) Dialog Box

Table 5-30 E1 Port Setting


Item Parameter Description
Collective Setting
CH Usage Used All All E1 CH is set to used
Not Used All All E1 Port is set to All unused
CH Usage Error Report All Report the input error of unused
Report all E1 CH.
Not Report All Not report the input error of
unused all E1 CH.
Impedance All CH 120Ω Set all E1 CH Impedance to 120Ω
All CH 75Ω Set all E1 CH Impedance to 75Ω
CH Usage Used E1 CH is set to used
Not Used E1 CH is set to unused
CH Usage Error Report Report the input error of unused
Report E1 CH.
Not Report Not report the input error of
unused E1 CH.
Impedance Setting 120Ω Set E1 Port Impedance to 120Ω
75Ω Set E1 Port Impedance to 75Ω
Port Name 1 to 32 Specify the Port name of the E1
CH

NWD-107461-04E Operation
System Operation 5-123

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-214 Information Box

8. The E1 Port Setting window appears again. Confirm the displayed parameters.

Figure 5-215 E1 Port Setting Window

This step ends the procedure.

Operation NWD-107461-04E
5-124 System Operation

5.1.3.2 STM-1 Port Setting

Configure the STM-1 port mode, usage, AIS generation, ALS (Automatic Laser
Shutdown) and tree setting.

Procedure 5-45

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select STM-1 Port Setting from the E1/STM-1/Cross Connect Setting


sub menu.

4. The STM-1 Port Setting window appears. Click Modify button.

Modify button

Figure 5-216 STM-1 Port Setting Window

5. The STM-1 Port Setting dialog box appears. Refer to the table below to assign
a proper value for each parameter.

NWD-107461-04E Operation
System Operation 5-125

Figure 5-217 STM-1 Port Setting Dialog Box

Table 5-31 STM-1 Port Setting


Item Parameter Description
STM-1 Mode Through Through Mode of STM-1
Channelized Channelized Mode of STM-1
Port Usage Used Use STM-1 Port
Not Used Not user STM-1 Port
Port Name 1 to 32 character Specify the port name of the STM-1
MS - AIS Generation Enable Enable device stop output laser when
receiving STM1 signal lost (optical or
radio) (RLOS) and send out MS-AIS.
Disable Disable device stop output laser when
receiving STM1 signal lost (optical or
radio) (RLOS) and send out MS-AIS
ALS Usage Enable Enable ALS (Auto Laser Shutdown)
Disable Disable ALS (Auto Laser Shutdown)

Operation NWD-107461-04E
5-126 System Operation

Item Parameter Description


ALS Interval 60 sec Set the delay of release ALS after
restored
180 sec
300 sec
Trace Setting
Trace Mode J0:Section Trace Enable RS-TIM detection
J1:High Order Path Trace Enable HP-TIM detection
Trace Mismatch AIS Enable Enable transmit AIS alarm when TIM
Generation Action detected
Disable Disable transmit AIS alarm when TIM
detected
Section Trace Send 1 to 15 Set J0 in transmit direction
Expected Section 1 to 15 Set J0 in receiving direction
Trace
High Order Path - Not select
Trace
Expected High Order - Not select
Path Trace
Received Trace Value
Received select trace - Not select
Port 01
Received High Order - Not select
Path Trace
Radio Alarm Transfer Setting
Radio Alarm Transfer Enable To transfer radio alarms to ch-STM-1
VC-12 overhead field for configuring E-1
level SNCP with radio and ch-STM-1
Disable

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-218 Information Box

8. The STM-1 Port Setting window appears again. Confirm the displayed
parameters.

NWD-107461-04E Operation
System Operation 5-127

Figure 5-219 STM-1 Port Setting Window

This step ends the procedure.

5.1.3.3 Cross Connect Setting

User can add, edit and delete the Cross Connect. Upto152 cross connections in total
can be created

In addition, if a user sets the Cross Connect Type to RST when Add Cross Connect,
Port (CH) utilization can be observed.

iPASOLINK supports 2M E1 level Cross Connect. The packets that support Cross
Connect are listed in the following table.

Table 5-32 Cross Connect Setting


Item Max. Max. Description
Mounted Ports
MODEM-S 2 152 -
16E1 1 16 -
16E1-S 1 16 Optional; only 1 can be mounted on a single
STM1-S (channelized 63 device.
mode) STM1-S (through mode) does not support a
STM1-S (through mode) 1(75E1) customized cross connect.

Operation NWD-107461-04E
5-128 System Operation

The channelized STM-1 channel numbering is listed in the following table.

Table 5-33 Channelized STM-1 Numbering


STM-1 channelized TUG-3# TUG-2# TU-12#
Port No. #K #L #M

1 1 1 1
2 2 1 1
3 3 1 1
4 1 2 1
5 2 2 1
6 3 2 1
7 1 3 1
8 2 3 1
9 3 3 1
10 1 4 1
11 2 4 1
12 3 4 1
13 1 5 1
14 2 5 1
15 3 5 1
16 1 6 1
17 2 6 1
18 3 6 1
19 1 7 1
20 2 7 1
21 3 7 1
22 1 1 2
23 2 1 2
24 3 1 2
25 1 2 2
26 2 2 2
27 3 2 2
28 1 3 2
29 2 3 2
30 3 3 2
31 1 4 2

NWD-107461-04E Operation
System Operation 5-129

STM-1 channelized TUG-3# TUG-2# TU-12#


Port No. #K #L #M
32 2 4 2
33 3 4 2
34 1 5 2
35 2 5 2
36 3 5 2
37 1 6 2
38 2 6 2
39 3 6 2
40 1 7 2
41 2 7 2
42 3 7 2
43 1 1 3
44 2 1 3
45 3 1 3
46 1 2 3
47 2 2 3
48 3 2 3
49 1 3 3
50 2 3 3
51 3 3 3
52 1 4 3
53 2 4 3
54 3 4 3
55 1 5 3
56 2 5 3
57 3 5 3
58 1 6 3
59 2 6 3
60 3 6 3
61 1 7 3
62 2 7 3

63 3 7 3

Operation NWD-107461-04E
5-130 System Operation

(1) Add Cross Connect

(a) Cross Connect – Non Protection Mode

Procedure 5-46

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select Cross Connect Setting from the E1/STM-1/Cross Connect


Setting sub menu.

4. The Cross Connect Setting window appears. Click Add button to create a
new cross connection.

Add button

Figure 5-220 Cross Connect Setting Window

5. The Cross Connect Setting (Add) dialog box appears. Refer to the table
below to assign a proper value for each parameter accordingly.

NWD-107461-04E Operation
System Operation 5-131

Figure 5-221 Cross Connect Setting (Add) Dialog Box

Table 5-34 Cross Connect Setting


Item Parameter Description
No. 1 to 168 Cross connect service
number
Service Name 0 to 32 Cross connect service
name
Cross Connect E1 E1 level cross connect
Type
RST STM-1 Through mode
cross connect
Edge A
Protection Not check the radio Uncheck Protection means
box no E1 SNCP protection is
provided. Configure one of
Edge A only.
Pull-down menu Main Board Interface Block for Edge.A
(Block selection) MODEM1
MODEM2
16E1(Option)
STM-1(Option)

Operation NWD-107461-04E
5-132 System Operation

Click-to-Select Blue Selected Port/CH


Port/CH White Not Selected Port/CH
Gray Already used Port/CH
Edge.B
Protection Not check the radio Uncheck Protection means
box no E1 SNCP protection is
provided. Configure one of
Edge B only.
Pull-down menu Main Board Interface Block for Edge.B
(Block selection) MODEM1
MODEM2
16E1(Option)
STM-1(Option)
Click-to-Select Blue Selected Port/CH
Port/CH White Not Selected Port/CH
Gray Already used Port/CH
Item Parameter Description

Note: The port number of the Edge.A/B Term1 on the mounted card or
MODEM is change according to the channel spacing.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-222 Information Box

8. The Cross Connect Setting window appears again. Confirm the newly added
cross connect information displayed.

NWD-107461-04E Operation
System Operation 5-133

Figure 5-223 Cross Connect Setting Window

This step ends the procedure.

(b) Cross Connect – Protection Mode

Procedure 5-47

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select Cross Connect Setting from the E1/STM-1/Cross Connect


Setting sub menu.

4. The Cross Connect Setting window appears. Click Add button to create a
new cross connect.

Figure 5-224 Cross Connect Setting Window

5. The Cross Connect Setting (Add) dialog box appears. Refer to the table
below to assign a proper value for each parameter accordingly.

Note
The Hold Off Time Setting button enables guard time setting for SNCP mode,

Operation NWD-107461-04E
5-134 System Operation

and it can be set in an IDU basis.

Figure 5-225 Cross Connect Setting (Add) Dialog Box

Table 5-35 Cross Connect Setting


Item Parameter Description
No. 1 to 168 Cross connect service number
Service Name 0 to 32 Cross connect service name
Cross Connect Type E1 E1 level cross connect
RST STM-1 Through mode cross
connect
Edge.A
Protection Check the radio box If Protection is checked, both of
Edge.B Port/CH needs to be
specified.
Pull-down menu Main Board Interface Block for Edge.A
(Block selection) MODEM1
MODEM2
16E1(Option)
STM-1(Option)
Click-to-Select Blue Selected Port/CH

NWD-107461-04E Operation
System Operation 5-135

Port/CH White Not Selected Port/CH


Gray Already used Port/CH
Edge.B
Protection Check the radio box If Protection is checked, both of
Edge.B Port/CH needs to be
specified..
Pull-down menu Main Board Interface Block for Edge.B
(Block selection) MODEM1
MODEM2
16E1(Option)
STM-1(Option)
Click-to-Select Blue Selected Port/CH
Port/CH White Not Selected Port/CH
Gray Already used Port/CH

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-226 Information Box

8. The Cross Connect Setting window appears again. Confirm the newly added
cross connect information displayed.

Figure 5-227 Cross Connect Setting Window

This step ends the procedure.

Operation NWD-107461-04E
5-136 System Operation

(2) Modify (Edit) Cross Connect

Procedure 5-48

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select Cross Connect Setting from the E1/STM-1/Cross Connect


Setting sub menu.

4. The Cross Connect Setting window appears. Click the Service No. to be
modified.
Service No.

Figure 5-228 Cross Connect Setting Window

5. The Cross Connect Setting (Modify) dialog box appears. Modify the
parameter accordingly.

NWD-107461-04E Operation
System Operation 5-137

Figure 5-229 Cross Connect Setting (Modify) Dialog Box

6. Click OK button after modification.

7. The Information box appears. Click OK button.

Figure 5-230 Information Box

8. The Cross Connect Setting window appears again. Confirm the modified
parameters of the cross connect.

Operation NWD-107461-04E
5-138 System Operation

Figure 5-231 Cross Connect Setting Window

This step ends the procedure.

(3) Delete Cross Connect

Procedure 5-49

1. Expand Provisioning from the WebLCT menu.

2. Expand E1/STM-1/Cross Connect Setting from the Provisioning sub


menu.

3. Select Cross Connect Setting from the E1/STM-1/Cross Connect


Setting sub menu.

4. The Cross Connect Setting window appears. Click Delete button.

Delete button

Figure 5-232 Cross Connect Setting Window

5. The Cross Connect Setting (Delete) dialog box appears. Check the
Service No. to be deleted.

NWD-107461-04E Operation
System Operation 5-139

Service No.

Figure 5-233 Cross Connect Setting (Delete) Dialog Box

6. Click OK button.

7. The Confirmation box appears. Click OK button.

Figure 5-234 Confirmation Box

8. The Information box appears. Click OK button.

Figure 5-235 Information Box

9. The Cross Connect Setting window appears again. Confirm that the selected
cross connect has been deleted.

Operation NWD-107461-04E
5-140 System Operation

Figure 5-236 Cross Connect Setting Window

This step ends the procedure.

5.1.4 Equipment Clock / Synchronization Setting


This setting provides configuration of Clock (Internal or External) and Timing
Source selection of the equipment.

Specific System Configuration is available only when CLK2M-C card (option) is


installed. Detailed configuration is as shown below:

Table 5-36 Optional Clock Setting


System w/o CLK2M-C CLK2M-C
Radio 1+0/1+1 3 3
Radio n-way 3 3
Radio Ring 3 3
STM-1 Through 3 3
STM-1 Channelized − 3
SyncETH − 3
EXT CLK I/O − 3

The EXT Clock Setting menu list is as follows:

• Equipment Clock Setting

Select the Clock and Timing Source.

• EXT Clock Setting

Setting output CLK parameters.

NWD-107461-04E Operation
System Operation 5-141

5.1.4.1 Equipment Clock Setting

Procedure 5-50

1. Expand Provisioning from the WebLCT menu.

2. Expand Equipment Clock/Synchronization Setting from the


Provisioning sub menu.

3. Select Equipment Clock Setting from the Equipment


Clock/Synchronization Setting sub menu.

4. The Equipment Clock Setting window appears. Click Modify button.

Modify button

Figure 5-237 Equipment Clock Setting Window

5. The Equipment Clock Setting dialog box appears. Assign a proper value for
each parameter.

Operation NWD-107461-04E
5-142 System Operation

Figure 5-238 Equipment Clock Setting Dialog Box (with CLK2M-C Card)

Figure 5-239 Equipment Clock Setting Dialog Box (without CLK2M-C Card)

Table 5-37 Equipment Clock Setting (without CLK2M-C Card)


Item Parameter Description
Equipment CLK Mode Master Internal clock is used as
equipment clock. This setting must
be set for network master IDU
Slave (MODEM1) Received radio clock is used as
equipment clock. This setting must
be set for slave equipments with
1-hop and n-hop network
configuration.
Slave(AUTO) Received radio clock is used as
equipment clock. This setting
must be set for slave equipments
with radio ring configuration.

NWD-107461-04E Operation
System Operation 5-143

Table 5-38 Equipment Clock Setting (with CLK2M-C Card)


Item Parameter Description
Equipment CLK Mode Master Internal clock is used as
equipment clock.
Slave Best clock is selected by
automatically among clocks of
“Timing Source” entry. Selection is
based on quality and priority.
When all of clocks in the “Timing
Source” entry are failed, status of
equipment clock becomes
holdover.
SyncETH Enable Enable Synchronous Ethernet
Function in the IDU
Disable Disable Synchronous Ethernet
Function in the IDU
Timing Source Not Entry Select the object line clock.
MODEM 1/2 (valid when the Equipment CLK
GbE Line CLK Mode is Slave.)
E1 Line CLK
Option Line CLK (STM1)
EXT CLK
Port/CH E1: 1 to 16 CH Specify the Port or CH.
GbE: 1 to 6
Priority 1 to 12 Set the priority of timing source
(“1”: Highest Priority, manually. For XPIC, recommend 1
“12”: Lowest Priority) with Slave Equipment CLK mode.
WTR 0, 10, 20, 30 sec Set Wait To Restore time, which is
1 to 15 min the amount of time to wait before
a recovered timing source
becomes active again.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-144 System Operation

Figure 5-240 Information Box

8. The Equipment Clock Setting window appears again. Confirm the displayed
parameters.

Figure 5-241 Equipment Clock Setting Window

This step ends the procedure.

5.1.4.2 EXT Clock Setting

Procedure 5-51

1. Expand Provisioning from the WebLCT menu.

2. Expand Equipment Clock/Synchronization Setting from the


Provisioning sub menu.

3. Select Ext Clock Setting from the Equipment Clock/Synchronization


Setting sub menu.

4. The Ext Clock Setting window appears. Click Modify button.

NWD-107461-04E Operation
System Operation 5-145

Modify button

Figure 5-242 Ext Clock Setting Window

5. The Ext Clock Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-243 Ext Clock Setting Dialog Box

Operation NWD-107461-04E
5-146 System Operation

Table 5-39 EXT Clock Setting


Item Parameter Description
EXT Impedance 120 Ω Sets Ext Clock impedance to 120 Ω
75 Ω Sets Ext Clock impedance to 75 Ω
EXT CLK Interface bps Selects the Ext Clock in bps
Hz Selects the Ext Clock in Hz
CRC On/Off On Turns on Ext Clock CRC check
Off Turns off Ext Clock CRC check
Sa Bit Sa 4 to 8 Sets SSM bit of input/output Ext
Clock
EXT CLK Out SEL NOT SELECT Does not export CLK
NE CLK Export NE CLK (equipment clock)
MODEM1 Export MODEM1
MODEM2 Export MODEM2
GbE Line CLK Export GbE Line CLK
E1 Line CLK Export E1 Line CLK
Option Line CLK Export Option Line CLK
Port/CH E1: 1 to 16 CH Specify the Port or CH.
GbE: 1 to 6

Note: You can not change the Port/CH parameters when the same interface is
already registered on the Equipment clock setting.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-244 Information Box

8. The Ext Clock Setting window appears again. Confirm the displayed
parameters.

NWD-107461-04E Operation
System Operation 5-147

Figure 5-245 Ext Clock Setting Window

This step ends the procedure.

5.1.5 V.11/OW Setting


This setting provides the configuration of user interface (V.11, RS-232C) and OW
channel.

• V.11/SC Control Setting

Selecting the input of SC Channel, RS-232C, and V.11 from the SC channel of
each MODEM

• V.11 Directional Setting

Setting the working mode of V.11

• OW Setting

Setting the OW channel of the radio section and CALL OUT polarity

Operation NWD-107461-04E
5-148 System Operation

5.1.5.1 V.11/SC Setting

(1) SC Setting

Procedure 5-52

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select V.11/SC Setting from the V.11/OW Setting sub menu.

4. The V.11/SC Setting window appears. Click SC Channel.

SC Channel

Figure 5-246 V.11/SC Setting Window

5. The V.11/SC Setting (SC Channel) dialog box appears. Specify the proper
SC channel for each interface.

NWD-107461-04E Operation
System Operation 5-149

Figure 5-247 V.11/SC Setting (SC Channel) Dialog Box (for MODEM1)

Figure 5-248 V.11/SC Setting (SC Channel) Dialog Box (for STM1-S)

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-249 Information Box

8. The V.11/SC Setting window appears again. Confirm the displayed


parameters.

Operation NWD-107461-04E
5-150 System Operation

Figure 5-250 V.11/SC Setting Window

This step ends the procedure.

(2) MODEM

Procedure 5-53

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select V.11/SC Setting from the V.11/OW Setting sub menu.

4. The V.11/SC Setting window appears. Click MODEM1 or MODEM2.

NWD-107461-04E Operation
System Operation 5-151

Figure 5-251 V.11/SC setting Window

5. The V.11/SC Setting dialog box appears. Specify the proper SC channel for
each interface.

Figure 5-252 V.11/SC Setting Dialog Box (between MODEM1 and MODEM2)

Operation NWD-107461-04E
5-152 System Operation

Figure 5-253 V.11/SC Setting Dialog Box (between MODEM1 or MODEM2 to STM1-S)

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-254 Information Box

8. The V.11/SC Setting window appears again. Confirm the displayed


parameters.

NWD-107461-04E Operation
System Operation 5-153

Figure 5-255 V.11/SC Setting Window

This step ends the procedure.

(3) STM1-S

Procedure 5-54

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select V.11/SC Setting from the V.11/OW Setting sub menu.

4. The V.11/SC Setting window appears. Click STM1-S.

Operation NWD-107461-04E
5-154 System Operation

Figure 5-256 V.11/SC Setting Window

5. The V.11/SC Setting dialog box appears. Specify the proper SC channel for
each interface.

Figure 5-257 V.11/SC Setting Dialog Box (for STM1-S)

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

NWD-107461-04E Operation
System Operation 5-155

Figure 5-258 Information Box

8. The V.11/SC Setting window appears again. Confirm the parameters


displayed.

Figure 5-259 V.11/SC Setting Window

This step ends the procedure.

5.1.5.2 V.11 Directional Setting

Procedure 5-55

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select V.11 Directional Setting from the V.11/OW Setting sub menu.

Operation NWD-107461-04E
5-156 System Operation

4. The V.11 Directional Setting window appears. Click Modify button.

Figure 5-260 V.11 Directional Setting Window

5. The V.11 Directional Setting dialog box appears. Assign a proper value for
each parameter.

Figure 5-261 V.11 Directional Setting Dialog Box

Table 5-40 V.11 Directional Setting


Item Parameter Description
V.11-1/2 Direction Co-Directional The data receiving direction is same as
Setting the clock output/input direction.
Contra-Directional The data receiving direction is different
from the clock output/input direction.

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-262 Information Box

NWD-107461-04E Operation
System Operation 5-157

8. The V.11 Directional Setting window appears again. Confirm the displayed
parameters.

Figure 5-263 V.11 Directional Setting Window

This step ends the procedure.

5.1.5.3 OW Setting

(1) SW GRP1 (MODEM1/2)

Procedure 5-56

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select OW Setting from the V.11/OW Setting sub menu.

4. The OW Setting window appears. Click MODEM1 or MODEM2.

Figure 5-264 OW Setting Window

5. The OW Setting (MODEM - 1 + 0) dialog box appears. Specify a proper value


for the parameter.

Operation NWD-107461-04E
5-158 System Operation

Figure 5-265 OW Setting (MODEM - 1 + 0) Dialog Box

Table 5-41 OW Setting


Item Parameter Description
OW Use DSC Used Enables the use of OW channel
Not Used Disables the use of OW channel

6. Click OK button after setting the parameter.

7. The Information box appears. Click OK button.

Figure 5-266 Information Box

8. The OW Setting window appears again. Confirm the displayed parameters.

Figure 5-267 OW Setting Window

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-159

(2) AUX-S

Procedure 5-57

1. Expand Provisioning from the WebLCT menu.

2. Expand V.11/OW Setting from the Provisioning sub menu.

3. Select OW Setting from the V.11/OW Setting sub menu.

4. The OW Setting window appears. Click AUX-S.

AUX-S

Figure 5-268 OW Setting Window

5. The OW Setting (AUX-S) dialog box appears. Specify a proper value for the
parameter.

Figure 5-269 OW Setting (AUX-S) Dialog Box

Table 5-42 OW Setting


Item Parameter Description
Call Polarity Invert In case of a signal unlike the
normal signal
Normal In case of a normal signal

Operation NWD-107461-04E
5-160 System Operation

6. Click OK button after setting the parameter.

7. The Information box appears. Click OK button.

Figure 5-270 Information Box

8. The OW Setting window appears again. Confirm the displayed parameters.

Figure 5-271 OW Setting Window

This step ends the procedure.

5.1.6 Alarm/AIS Setting


This setting provides the configuration of alarm severity, color and the relevant
setting of AIS events.

• Correlation Setting

User can configure the condition of masking alarm (displaying/clearing on LCT


or LED).

• Alarm Severity Setting

User can specify the alarm severity among critical, major, and minor, and
warning for each alarm reported by iPASOLINK.

NWD-107461-04E Operation
System Operation 5-161

• AIS Setting

User can enable or disable sending of AIS alarm and specify the conditions and
delay of sending AIS alarm.

• BER Threshold

User can specify the threshold of BER alarm.

5.1.6.1 Correlation Setting

Procedure 5-58

1. Expand Provisioning from the WebLCT menu.

2. Expand Alarm/AIS Setting from the Provisioning sub menu.

3. Select Correlation Setting from the Alarm/AIS Setting sub menu.

4. The Correlation Setting window appears. Click Modify button.

Modify button

Figure 5-272 Correlation Setting Window

5. The Correlation Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-273 Correlation Setting Dialog Box

Operation NWD-107461-04E
5-162 System Operation

Table 5-43 Correlation Setting


Item Parameter Description
Alarm Correlation On Enables the mask of the lower level alarm
Off Disables the mask of the lower level alarm

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-274 Information Box

8. The Correlation Setting window appears again. Confirm the displayed


parameters.

Figure 5-275 Correlation Setting Window

5.1.6.2 Alarm Severity Setting

Procedure 5-59

1. Expand Provisioning from the WebLCT menu.

2. Expand Alarm/AIS Setting from the Provisioning sub menu.

3. Select Alarm Severity Setting sub menu.

4. The Alarm Severity Setting window appears. Click the MODEM tab.

Description is an example for MODEM. After the setting of MODEM, perform


similarly for other tabs.

5. Click the Modify button.

NWD-107461-04E Operation
System Operation 5-163

Modify button

Figure 5-276 Alarm Severity Setting Window

6. The Alarm Severity Setting (MODEM) dialog box appears.

7. Select the desired alarm status from the drop down list of Alarm Status.

Operation NWD-107461-04E
5-164 System Operation

Figure 5-277 Alarm Severity Setting (MODEM) Dialog Box

Table 5-44 Alarm Status

Item Parameter Description


Alarm Items Critical -
specific for each
Major -
tab
Minor -
Warning -

8. Set the alarm status for each Alarm Item, and then repeat the procedures for
other tabs.

9. After setting of severity, click OK button. Information box appears.

NWD-107461-04E Operation
System Operation 5-165

Figure 5-278 Information Box

This step ends the procedure.

5.1.6.3 AIS Setting

Procedure 5-60

1. Expand Provisioning from the WebLCT menu.

2. Expand Alarm/AIS Setting from the Provisioning sub menu.

3. Select AIS Setting from the Alarm/AIS Setting sub menu.

4. The AIS Setting window appears. Click Modify button.

Modify button

Figure 5-279 AIS Setting Window

5. The AIS Setting dialog box appears. Specify a proper value for each parameter.

Operation NWD-107461-04E
5-166 System Operation

Figure 5-280 AIS Setting Dialog Box

Table 5-45 AIS Setting


Item Parameter Description
AIS Activation LOF + High BER Sends AIS alarm after receiving LOF
Condition and High BER alarm
LOF Sends AIS alarm after receiving LOF
alarm only.
AIS Generated Report Report Reports AIS generated event
Not Report Does not report AIS generated event
AIS Received Report Report Reports AIS received event
Not Report Does not report AIS received event
AIS Received Alarm Specifies the AIS received event as
Condition alarm
Status Specifies the AIS received event as
event

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-281 Information Box

8. The AIS Setting window appears again. Confirm the displayed parameters.

NWD-107461-04E Operation
System Operation 5-167

Figure 5-282 AIS Setting Window

This step ends the procedure.

5.1.6.4 BER Threshold Setting

Specify the threshold of BER alarm of (High/Low)/STM-1 MUX input and


E-BER/SD.

(1) SW GRP1 (MODEM1/2)

Procedure 5-61

1. Expand Provisioning from the WebLCT menu.

2. Expand Alarm/AIS Setting from the Provisioning sub menu.

3. Select BER Threshold Setting from the Alarm/AIS Setting sub menu.

4. The BER Threshold Setting window appears. Click the desired MODEM No.
(or SW GRP1) to configure.

MODEM No.

Figure 5-283 BER Threshold Setting Window

Operation NWD-107461-04E
5-168 System Operation

5. The BER Threshold Setting (MODEM - 1 + 0) dialog box appears. Assign a


proper value for each parameter.

Figure 5-284 BER Threshold Setting (MODEM - 1 + 0) Dialog Box

Table 5-46 BER Threshold


Item Parameter Description
High BER 1E-3 to1E-5 Setting High BER Threshold of MW
Low BER 1E-6 to 1E-9 Setting Low BER Threshold of MW

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-285 Information Box

8. The BER Threshold Setting window appears again. Confirm the displayed
parameters.

NWD-107461-04E Operation
System Operation 5-169

Figure 5-286 BER Threshold Setting Window

This step ends the procedure.

(2) STM1-S

Procedure 5-62

1. Expand Provisioning from the WebLCT menu.

2. Expand Alarm/AIS Setting from the Provisioning sub menu.

3. Select BER Threshold Setting from the Alarm/AIS Setting sub menu.

4. The BER Threshold Setting window appears. Click STM1-S.

STM-1S

Figure 5-287 BER Threshold Setting Window

5. The BER Threshold Setting (STM1-S) dialog box appears. Assign a proper
value for each parameter.

Operation NWD-107461-04E
5-170 System Operation

Figure 5-288 BER Threshold Setting (STM1-S) Dialog Box

Table 5-47 BER Threshold


Item Parameter Description
E-BER (MUX) 1E-3 to1E-5 Setting E-BER Threshold of STM-1 MUX
SD (MUX) 1E-6 to 1E-9 Setting SD Threshold of STM-1 MUX

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-289 Information Box

8. The BER Threshold Setting window appears again. Confirm the displayed
parameters.

Figure 5-290 BER Threshold Setting Window

This step ends the procedure.

NWD-107461-04E Operation
System Operation 5-171

5.1.7 PMON/RMON Setting


This setting provides the relevant configuration of PMON (except Ethernet port) and
RMON (Ethernet port), including threshold.

The PMON/RMON Setting menu list is as follows:

• PMON Threshold Setting

Threshold setting of PMON (except Ether port)

• PMON Other

Threshold setting of TCN level

• RMON Threshold Setting

Threshold setting of RMON (Ether port)

• RMON Other

5.1.7.1 PMON Threshold Setting

(1) Main Board Tab

Procedure 5-63

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select PMON Threshold Setting from the PMON/RMON Setting sub


menu.

4. The PMON Threshold Setting window appears. Select the Main Board tab.

5. The Main Board tab appears. Click Modify button.

Operation NWD-107461-04E
5-172 System Operation

Modify button

Figure 5-291 Main Board Tab

6. The Main Board dialog box appears. Assign a proper value for each parameter.

NWD-107461-04E Operation
System Operation 5-173

Figure 5-292 Main Board Dialog Box

Table 5-48 PMON Threshold Setting


Item Parameter Description
15minutes/1day Occur 0 to 4294967295
Recover 0 to 4294967295

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-293 Information Box

Operation NWD-107461-04E
5-174 System Operation

9. The Main Board tab appears again. Confirm the displayed parameters.

Figure 5-294 Main Board Tab

This step ends the procedure.

(2) MODEM Tab

Procedure 5-64

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select PMON Threshold Setting from the PMON/RMON Setting sub


menu.

4. The PMON Threshold Setting window appears. Select the MODEM1 or


MODEM2 tab.

5. The MODEM1 or MODEM2 tab appears. Click Modify button.

NWD-107461-04E Operation
System Operation 5-175

Modify button

Figure 5-295 MODEM1 or MODEM2 Tab

6. The RF-MODEM1 or RF-MODEM2 dialog box appears. Assign a proper value


for each parameter.

Figure 5-296 RF-MODEM1 or RF-MODEM2 Dialog Box

Operation NWD-107461-04E
5-176 System Operation

Table 5-49 PMON Threshold Setting (MODEM1 or MODEM2 Tab)


Item Parameter Description
RF 15minutes 0 to2014000 Specifies the threshold of generation/recovery
BBE of 15 min RS-BBE alarm
1 day 0 to193344000 Specifies the threshold of generation/recovery
of 1 day RS-BBE alarm
RF ES 15minutes 0 to 900 Specifies the threshold of generation/recovery
of 15 min RF ES alarm
1 day 0 to 86400 Specifies the threshold of generation/recovery
of 1 day RF ES alarm
RF 15minutes 0 to 900 Specifies the threshold of generation/recovery
SES of 15 min RF SES alarm
1 day 0 to 86400 Specifies the threshold of generation/recovery
of 1 day RF SES alarm
RF 15minutes 0 to 900 Specifies the threshold of generation/recovery
SEP of 15 min RF SEP alarm
1 day 0 to 86400 Specifies the threshold of generation/recovery
of 1 day RF SEP alarm
RF 15minutes 0 to 900 Specifies the threshold of generation/recovery
UAS of 15 min RF UAS alarm
1 day 0 to 86400 Specifies the threshold of generation/recovery
of 1 day RF UAS alarm
RF 15minutes 0 to 900 Specifies the threshold of generation/recovery
OFS of 15 min RF OFS alarm
1 day 0 to 86400 Specifies the threshold of generation/recovery
of 1 day RF OFS alarm

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-297 Information Box

9. The MODEM1 or MODEM2 tab appears again. Confirm the displayed

NWD-107461-04E Operation
System Operation 5-177

parameters.

Figure 5-298 MODEM1 or MODEM2 Tab

This step ends the procedure.

(3) STM1-S Tab

Procedure 5-65

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select PMON Threshold Setting from the PMON/RMON Setting sub


menu.

4. The PMON Threshold Setting window appears. Select the STM1-S tab.

5. The STM1-S tab appears. Click Modify RS or Modify MS button.

Operation NWD-107461-04E
5-178 System Operation

Figure 5-299 STM1-S Tab

6. The MS - STM1-S or RS - STM1-S dialog box appears. Assign a proper value


for each parameter.

Figure 5-300 MS - STM1-S Dialog Box

NWD-107461-04E Operation
System Operation 5-179

Figure 5-301 RS - STM1-S Dialog Box

Table 5-50 PMON Threshold Setting (STM1-S MS)


Item Parameter Description
MS BBE 15min 0 to16777215 specify the threshold of generation/recovery
of 15 min MS BBE Alarm
1 day 0 to specify the threshold of generation/recovery
1610612640 of 1 day MS BBE Alarm
MS ES 15min 0 to 900 specify the threshold of generation/recovery
of 15 min MS ES Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day MS ES Alarm
MS SES 15min 0 to 900 specify the threshold of generation/recovery
of 15 min MS SES Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day MS SES Alarm
MS SEP 15min 0 to 900 specify the threshold of generation/recovery
of 15 min MS SEP Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day MS SEP Alarm
MS UAS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min MS UAS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day MS UAS Alarm
MS OFS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min MS OFS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day MS OFS Alarm

Operation NWD-107461-04E
5-180 System Operation

Table 5-51 PMON Threshold Setting (STM1-S RS)


Item Parameter Description
RS BBE-RS 15min 0 to 16777215 specify the threshold of generation/recovery
of 15 min RS BBE-RS Alarm
1 day 0 to specify the threshold of generation/recovery
1610612640 of 1 day RS BBE-RS Alarm
RS ES-RS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min RS ES-RS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day RS ES –RS Alarm
RS SES-RS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min RS SES-RS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day RS SES-RS Alarm
RS SEP-RS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min RS SEP-RS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day RS SEP-RS Alarm
RS UAS-RS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min RS UAS-RS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day RS UAS-RS Alarm
RS OFS-RS 15min 0 to 900 specify the threshold of generation/recovery
of 15 min RS OFS-RS Alarm
1 day 0 to 86400 specify the threshold of generation/recovery
of 1 day RS OFS-RS Alarm

7. Click OK button after setting the parameters.

8. The Information box appears. Click OK button.

Figure 5-302 Information Box

9. The STM1-S tab appears again. Confirm the parameters displayed.

NWD-107461-04E Operation
System Operation 5-181

Figure 5-303 STM1-S Tab

This step ends the procedure.

5.1.7.2 PMON Other

Procedure 5-66

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select PMON Other from the PMON/RMON Setting sub menu.

4. The PMON Other window appears. Click the desired MODEM.

Operation NWD-107461-04E
5-182 System Operation

Figure 5-304 PMON Other Window

5. The PMON Other Setting dialog box appears. Assign a proper value for each
parameter.

Figure 5-305 PMON Other Setting Dialog Box

Table 5-52 PMON Other Setting


Item Parameter Description
RX Level TCN Threshold -99 to -30 dBm Specify the threshold of TCN RX Level alarm

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-306 Information Box

8. The PMON Other window appears again. Confirm the displayed parameters.

NWD-107461-04E Operation
System Operation 5-183

Figure 5-307 PMON Other Window

This step ends the procedure.

5.1.7.3 RMON Threshold Setting

Procedure 5-67

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select RMON Threshold Setting from the PMON/RMON Setting sub menu.

4. The RMON Threshold Setting window appears. Click Modify button.

Figure 5-308 RMON Threshold Setting Window

5. The RMON Threshold Setting dialog box appears. Assign a proper value for
each parameter.

Operation NWD-107461-04E
5-184 System Operation

Figure 5-309 RMON Threshold Setting Dialog Box

Table 5-53 RMON Threshold Setting


Item Parameter Description
RX Drop Events 15 min 0 to 133929000 Specify the threshold of received of 15
min RX Drop Events
1 day 0 to 4294967294 Specify the threshold of received of 1
day RX Drop Events
RX Undersize Pkts 15 min 0 to 133929000 Specify the threshold of received of
15min RX Under size Packets
1 day 0 to 4294967294 Specify the threshold of received of
1day RX Under size Packets
RX Fragments 15 min 0 to 133929000 Specify the threshold of received of
15min RX Fragments
1 day 0 to 4294967294 Specify the threshold of received of
1day RX Fragments
RX CRC Alignment Errors 15 min 0 to 133929000 Specify the threshold of received of 15
min RX CRC Alignment Errors
1 day 0 to 4294967294 Specify the threshold of received of
1day RX CRC Alignment Errors
RX oversize Pkts 15 min 0 to 133929000 Specify the threshold of received of 15
min RX over size Packets
1 day 0 to 4294967294 Specify the threshold of received of
1day RX over size Packets
TX Collisions 15 min 0 to 133929000 Specify the threshold of received of 15
min TX Collisions
1 day 0 to 4294967294 Specify the threshold of received of
1day TX Collisions

NWD-107461-04E Operation
System Operation 5-185

6. Click OK button after setting the parameter.

7. The Information box appears. Click OK button.

Figure 5-310 Information Box

8. The RMON Threshold Setting window appears again. Confirm the displayed
parameters.

Figure 5-311 RMON Threshold Setting Window

This step ends the procedure.

5.1.7.4 RMON Other

(a) Add VLAN Counter

Procedure 5-68

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select RMON Other from the PMON/RMON Setting sub menu.

Operation NWD-107461-04E
5-186 System Operation

4. The RMON Other window appears. Click VLAN counter No. in the VLAN
Counter Select tab.

VLAN counter No.

Figure 5-312 RMON Other Window

5. The VLAN Counter Select dialog box appears. Assign a proper value for each
parameter.

Figure 5-313 VLAN Counter Select Dialog Box

NWD-107461-04E Operation
System Operation 5-187

Table 5-54 RMON Other


Item Parameter Description
Item Main Board (Default)
MODEM1
MODEM2
Port Port01 (Default) to Port01 is available when Item is
Port 06 MODEM1 or 2
Enable radio Button Check / Uncheck Check the check box of object
VLAN ID

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Figure 5-314 Information Box

8. The RMON Other window appears again. Confirm the displayed parameters.

Figure 5-315 RMON Other Window

Operation NWD-107461-04E
5-188 System Operation

This step ends the procedure.

(b) Delete VLAN Counter

Procedure 5-69

1. Expand Provisioning from the WebLCT menu.

2. Expand PMON/RMON Setting from the Provisioning sub menu.

3. Select RMON Other from the PMON/RMON Setting sub menu.

4. The RMON Other window appears. Click Delete VLAN Counter button.

Figure 5-316 RMON Other Window

5. The Delete VLAN Counter dialog box appears. Select the VLAN Counter
No. to be deleted.

Figure 5-317 Delete VLAN Counter Dialog Box

6. Click OK button after setting the parameters.

NWD-107461-04E Operation
System Operation 5-189

7. The Confirmation box appears. Click OK button.

Figure 5-318 Confirmation Box

8. The Information box appears. Click OK button.

Figure 5-319 Information Box

9. The RMON Other window appears again. Confirm the displayed parameters.

Figure 5-320 RMON Other Window

This step ends the procedure.

Operation NWD-107461-04E
5-190 System Operation

5.1.8 AUX Setting


The AUX Setting menu list is as follows:

• AUX Input Setting

• AUX Output Setting

5.1.8.1 AUX Input Setting

Procedure 5-70

1. Expand Provisioning from the WebLCT menu.

2. Expand AUX Setting from the Provisioning sub menu.

3. Select AUX Input Setting from the AUX Setting sub menu.

4. The AUX Input Setting window appears. Click Modify button in the desired
AUX tab.

Modify button

Figure 5-321 AUX Input Setting Window

5. The AUX Input Setting dialog box appears. Assign a proper value for each
parameter.

NWD-107461-04E Operation
System Operation 5-191

Figure 5-322 AUX Input Setting Dialog Box

Table 5-55 AUX Input Setting


Item Parameter Description
Name 1 to 32 character Input Alarm Name
Condition Alarm when Event The alarm is reported when Event
On(Close) ON
Alarm when Event The alarm is reported when Event
Off(Open) OFF
Status Status information is reported instead
of the alarm
Status Strings
Event On 1 to 32 character Input the event name to be displayed
(Close) on the Event Status
Event Off 1 to 32 character
(Open)
X.733
Severity Critical/major/Minor/Warning Specify the alarm Severity
Alarm Type Default: Specify the Alarm Type name
CommunicatonAlarm
Probable Cause Default: adapterError Specify the Probable Cause name

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-192 System Operation

Figure 5-323 Information Box

8. The AUX Input Setting window appears again. Confirm the displayed
parameters.

Figure 5-324 AUX Input Setting Window

This step ends the procedure.

5.1.8.2 AUX Output Setting

Procedure 5-71

1. Expand Provisioning from the WebLCT menu.

2. Expand AUX Setting from the Provisioning sub menu.

3. Select AUX Output Setting from the AUX Output Setting sub menu.

4. The AUX Output Setting window appears. Click the desired output No.

NWD-107461-04E Operation
System Operation 5-193

Output No.

Figure 5-325 AUX Output Setting Window

5. The AUX Output Setting dialog box appears. Specify a proper value for the
parameters.

Figure 5-326 AUX Output Setting Dialog Box

Table 5-56 AUX Output Setting


Item Parameter Description
Name 1 to 32 character Input the Alarm Name
Control Event Off (Open) select the desired output condition
Event On (Close) of the selected relay output
Event On(Close) 1 to 32 character Input the event name
Event Off(Open) 1 to 32 character

6. Click OK button after setting the parameters.

7. The Information box appears. Click OK button.

Operation NWD-107461-04E
5-194/END System Operation

Figure 5-327 Information Box

8. The AUX Output Setting window appears again. Confirm the displayed
parameters.

Figure 5-328 AUX Output Setting Window

This step ends the procedure.

NWD-107461-04E Operation
Abbreviations 6-1

6. ABBREVIATIONS

ACAP Adjacent Channel Alternate CoS Class of Service


Polarization CPU Central Processing Unit
ACCP Adjacent Channel Co-Polarization CR Critical
ACK Acknowledgement CRC Cyclic Redundancy Check
AGC Automatic Gain Control CS Channel Separation
AIS Alarm Indication Signal CTRL Control
ALM Alarm CV near end Code Violation
ALS Automatic Laser Shutdown CW Carrier Wave
AMR Adaptive Modulation Radio DA Destination Address
ANT, Ant. Antenna DADE Differential Absolute Delay
APS Automatic Protection Switch Equalizer
ATT Attenuator DB Database
ATPC Automatic Transmitter Power DC Direct Current
Control DCN Data Communication Network
AU Administrative Unit DEG Degraded
AUX Auxiliary DEI Drop Eligible Indicator
Ave Average DEM Demodulator
BBE Background Block Error Des(Dest) Destination
BER Bit Error Rate DI Data-in
BPF Band Pass Filter D/I Drop and Insert
BS Base Station DL Download
BSC Base Station Controller DM Delay Measurement
BTS Base Transceiver Station DMM Delay Measurement Message
CAPEX Capital Expenditure DMR Delay Measurement Reply
CBS Committed Burst Size DO Data-out
CCDP Co-Channel Dual Polarization DSCP Differentiated Services Code Point
CCM Continuity Check Message DUP Duplexer
CEPT Conference of European Postal & DXC Digital Cross Connect
Telecommunication Administration E1 E-carrier level 1
CIR Committed Information Rate EBS Express Burst Size
CKT Circuit EIR Excess Information Rate
CLK Clock EMC Electro Magnetic Compatibility
CMF Channel Mismatch Failure EML Element Management Layer
CMI Coded Mark Inversion EMS Element Management System
CONV Converter EOW C Order Wire
CORBA Common Object Request Broker EPS ETH-Protection Switch
Architecture EQL Equalizer

Operation NWD-107461-04E
6-2 Abbreviations

ERP ETH-Ring Protection Switch HP Higher order Path


ES Errored Seconds HYB Hybrid
ETH-CC ETH-Continuity Check function H/W Hardware
ETH-LB ETH-Loopback function ID Identification
ETH-LBM ETH-Loopback Message IDU Indoor Unit
ETH-LBR ETH-Loopback Reply IE Internet Explorer
ETH-LT ETH- Link Trace function IEC International Electrotechnical
ETH-LTM ETH-Link Trace Message Commission
ETH-LTR ETH-Link Trace Reply IEEE Institute of Electrical and
ETH-OAM Ethernet Operations, Administration Electronics Engineers
and Maintenance I/F Interface
ETH-OAM ETH-OAM Loopback IF Intermediate Frequency
LB IHG iPASOLINK High Grade
ETH-OAM ETH-OAM Link Trace IN Input
LT INTFC Interface
ETH-RDI ETH-Remote Defect Indication I/O Input/Output
function IP Internet Protocol
ETSI European Telecommunications ITU International Telecommunication
Standards Institute Union
EXC Electrical Cross Connect ITU-R Radio Communication Sector of ITU
E-to-E. End-to-End ITU-T Telecommunication Sector of ITU
Fail Failure L2SW Layer2-Switch
F/B Front Back Ratio LAN Local Area Network
FCS Frame Check Sequence LB Loopback
FDB Forwarding Database LBM Loopback Message
FE Fast Ethernet LCD Loss of Cell Delineation
FEC Forward Error Correction LCT Local Craft Terminal
FEBBE Far End Background Block Error LDPC Low Density Parity Check
FEES Far End Errored Seconds LED Light Emitting Diode
FESES Far End Severely Errored Seconds Lev. Level
FEUAS Far End Unavailable Seconds LLF Link Loss Forwarding
FPGA Field Programmable Gate Array LM Loss Measurement
F/W Firmware LMM Loss Measurement Message
GbE, GBE Gigabit Ethernet LNA Low Noise Amplifier
3GPP Third Generation Partnership LO Local Oscillator
Project LOC Loss of Continuity
GUI Graphical User Interface LOF Loss of Frame
H Horizontal LOM Loss of Multiframe
HDB High Density Bipolar LOP Loss of Pointer
HK House Keeping LO REF Local Reference Signal Loss

NWD-107461-04E Operation
Abbreviations 6-3

LOS Loss of Signal NE Network Element


LP Lower order Path NML Network Management Layer
LPM Link Performance Monitor NMS Network Management System
LT Link Trace OAM Operation, Administration and
LTI Loss of incoming Timing Input Maintenance
LTM Link Trace Message OCR Occur
MAC Media Access Control Octs Octets
MAINT Maintenance ODU Out-Door Unit
MAX Maximum OFS Out of Frame Second
Mdev Mean Deviation OMT Ortho-Mode Transducer
MDCPU MODEM CPU OPEX Operational Expenditure
MDI Medium Dependent Interface OPP Opposite
MDIX Medium Dependent Interface OPR Operation
Crossover OPT Optical
MD4 Message Digest Algorithm 4 OSPF Open Shortest Path First
MD5 Message Digest Algorithm 5 OSS Operation Support System
MEG Maintenance Entity Group OUT Output
MEM Memory OW Oder Wire
MEP MEG End Point PA Power Amplifier
MIN Minimum PBR Pressurizable Type B, flange profile
MIP Maintenance Intermediate Point square Rectangular
MIX Mixer PCP Priority Code Point
MJ Major PDH Plesiochronous Digital Hierarchy
MMC Multi Media Card PDU Protocol Data Unit
MME Mobility Management Entity PGM Program
MMG Mismerge PHY Physical
MN Minor PIR Peak Information Rate
MOD Modulator PJE Pointer Justification Event
MODEM Modulator Demodulator PJE-N Pointer Justification Event Negative
MON Monitor Stuff
MPX Multiplexer PJE-P Pointer Justification Event Positive
MS Multiplex Section Stuff
MSC Mobile Switching Center PKG Package
MSDU MAC Service Data Unit Pkts Packets
MSP Multiplex Section Protection PLM Payload Label Mismatch
MTBF Mean Time Between Failure PMC PASOLINK Management Card
MTPC Manual Transmitter Power Control PMON Performance Monitor
MUX Multiplexing Equipment PNMSj PASOLINK Network Management
N/A Not Applicable System Java Version
NBI Northbound Interface PPI PDH PHY Interface

Operation NWD-107461-04E
6-4 Abbreviations

ppm parts per million SNCP Sub-network Connection Protection


PPP Point-to-Point Protocol SNMP Simple Network Management
PPS Path Protection Switch Protocol
PQ Priority Queuing SP Strict Priority
PRM Parameter SPD Speed
PROT Protection SRC Source MAC Address
PS Power Supply STAT Status
PSC Protection Switching Counts STD Standard
PSD Protection Switching Duration STM Synchronous Transport Module
PWR Power STP Spanning Tree Protocol
QAM Quadrature Amplitude Modulation SUB Substitute
QoS Quality of Service SW Switch
QPSK Quadrature Phase Shift Keying S/W Software
RCVR Recover SWG Switch Group
REF Reference SYNC Synchronous
REM Remote TCI Tag Control Information
RDI Remote Defect Indication TCN Threshold Crossing Notification
RF Radio Frequency TDM Time Division Multiplex
RFS Radio Frequency Systems TDMoP TDM over Packet
RL Relay TEMP Temperature
RMON Remote Network Monitoring TERM Terminal
RNC Radio Network Controller TF Transmit Fail
RPL Ring Protection Link TIM Trace Identifier Mismatch
RS Regenerator Section TLV Type Length Value
RS-232 Recommended Standard 232 TM Through Mode
RSL Received Signal Level TNC Threaded Neil Councilman
RST Regenerator Section Termination ToS Type of Service
RSTP Rapid Spanning Tree Protocol TP Twin Path
RX Receiver TPID Tag Protocol Identifier
SC Service Channel TQC Total Quality Control
SD Space Diversity TTL Time To Live
SDH Synchronous Digital Hierarchy TU Tributary Unit
SEG Segment TX Transmitter
SEP Severely Errored Period UAE UAS Event
SES Severely Errored Seconds UAS Unavailable Seconds
SFP Small Form factor Pluggable UL Upload
SGMI Security Gateway Management UNEQ Unequipped
Interface UNEXP Unexpected
SMS Synchronous Multiplexing System Unicast Unicast Delay Measurement Reply
SMU Source Measure Unit DMR

NWD-107461-04E Operation
Abbreviations 6-5

UNM Unexpected MEP


UNP Unexpected Period
USB Universal Serial Bus
V Vertical
V Volt
VC Virtual Channel
VLAN Virtual LAN
VP Virtual Path
VPN Virtual Private Network
VSWR Voltage Standing Wave Ratio
WDM Wavelength Division Multiplexing
WG Waveguide
WR Warning
WRR Weighted Round Robin
WS Wayside
WWW World Wide Web
XCTRL XPIC Control
X-DEM XPIC Demodulator
XFP 10(X) Gigabit Small Form Factor
Pluggable
XIF XPIC IF
XPD Cross Polarization Discrimination
Ratio
XPIC Cross Polarization Interference
Canceller
XREF XPIC Reference

Operation NWD-107461-04E
6-6/END Abbreviations

This page is intentionally left blank.

NWD-107461-04E Operation