Asterix 750
Asterix 750
Asterix 750
Cz: 37.52 cm
Ax: 12.3 cm2 BS000
Ixx: 15195.9 cm4
Izz: 29.9 cm4
BS000
Maximum single point load limited to 29.5kN across all load conditions.
Notes:
1. Safe load data given for guidance only and assumes simple supports each end.
2. This TI sheet is to be read in conjunction with the ASTERIX User Guide.
3. Data provided is calculated in accordance with EN 1999 and factored to EN 12811.
4. Data provided assumes spigoted connections using steel spigot BS0005.
5. All spigoted connections secured using quick release pin AF0001 or G8.8 M12x60 Bolt with nut AF0007
6. All loads must be applied within 150mm from a node point.
7. All supports must have a minimum width of 35mm.
8. Lacing tubes must be connected using a minimum 3kN connection.
9. For 4 bolt connections joint moment is decisive. Higher values may only be used where joint positions can be planned.
TI 003-K12-01