COMPOSER Carl Zeller - SEIBOLD Online-Analyser for Cadmium

Sources directly proportional to metal


concentration.
Cadmium compounds belong to the most
hazardous pollutants in the environment.
Industry. Cadmium metal is used in the
steel industry and in plastics. Cadmium
compounds are widely used in batteries.
Drinking water. Contamination in
drinking-water may also be caused by
impurities in the zinc of galvanized pipes
and solders and some metal fittings. A
guideline value of 0.005 mg/litre was
recommended for cadmium in drinking-
water.
Toxicity. Cadmium is toxic to a wide
range of organs. Primary targets are the
kidneys, bone, and the lung.

Method Advantage of the system


 Robust design.
 Minimal maintenance.
Metal is measured as chelate complex  Easy handling.
between metal ions in the waste water  High accuracy and precision.
and sensitive spectrophotometric  Suitable for mission critical
reagent dye. Change of the intensity of applications.
the visible light throughout cuvette  Automated cleaning and
containing formed metal complex is calibration.

System information
Measurement variable Cadmium (Cd)
Measurement application Drinking water, river monitoring, electroplating
and semiconducting industry
Measurement ranges 0.005 – 1.000 mg/L (ppm)
other ranges possible upon request
Accuracy and Precision ± 3 % (based on full scale)
Resolution 0.005 mg/L
Calibration and cleaning automated
Seibold Reagent kit Buffer and Dye
Provided by Sigma Aldrich
Continuous Analysis. Reliable Results.

COMPOSER Carl Zeller - SEIBOLD Online-Analyser for Cadmium

MEASUREMENT INFORMATION
Measurement method
Spectrophotometric (LED, detector)
Measurement interval
Continuous; Discontinuous (programmable, external start)
Sample and Reagents consumption per measurement
Sample: ~ 75 - 200 ml
Seibold Buffer and Reagent: ~ 3 ml
ENVIRONMENTAL DATA
Ambient operating temperature, sample temperature: 5 to 40°C
Ambient operating humidity: Up to 95 % RH non-condensing (bellow the condensation
limit)
ELECTRICAL DATA
Power supply
Supply voltage: 220 … 230 V AC, 50…60 Hz (110 V AC or 24 V DC, optional)
Power consumption: approx 50 VA
Output signal: 4…20 mA
Screen
Color, TFT, liquid crystal display (LCD) with built-in backlight and brightness adjustment.
MAINTENANCE
Maintenance interval: 3 months

SEIBOLD Wasser-Analysatorenfabrik GmbH, Büropark Donau, Inkustrasse 1-7/5/2, A-3400


Klosterneuburg, phone: +43 22 43 20 787, web: www.seibold-wasser.at, e-mail: [email protected]