Dibta Compressed
Dibta Compressed
The DIBTA (Delta Infrared Breath Test Analyser) determines the isotope ratio
of 13C/12C of CO2 in human breath with a precision of +/-0,1 delta per mille and
is supplied with a software to evaluate the commonly known 13C Breath Tests.
Newly developed tests can be defined, too. The DIBTA is controlled by a
DIBTA
high finesse instruments for measurements of isotope ratios in breath gas
Technical data:
Weight : 20kg
Dimensions: Height x Width x Depth 27,2 x 46,5 x 54 cm
Power supply: 24 VDC via medical power supply pack
(90...264 VAC)
Power requirement: Typ. 40 W, Max. 90W during warm-up
Data connection: LAN
Operating system: Computer with XP to Windows 7, Mac OS X
or Linux
Application, System specification:
Test medium: Breath from breath bags or breath masks
Physical measured value: 13
CO2 and 12CO2
Measuring range CO2 total
Minimum concentration CO2: 0,2%
Maximum concentration CO2: 5%
Precision: +/-0,1 delta per mille 13CO2 /12CO2 over 1h
Reproducibility (one sample N=8): +/-0,1 delta per mille
Software:
• Runs on Windows, Linux, Mac
• Multitasking: Define new tests in the measurement list or calculate and print
results while performing your actual measurements.
• User management: User rights depend on user login. There are three levels
of use: Administrator, doctor and assistent.
• Use one of the predefined tests and compare your results to normal collectives.
• Define new tests for a clinical study.
• Export to Excel and produce PDF-Reports with your self defined individual
lay out of the doctor´s letter. Get Excel templates for every test type you need.
• Optional: Connect to IT-management system. In human metabolism CO2 is often the • None invasive Applications:
final product, which is exhaled and thus • No side effects • Infection
easy accessible to analysis. • Harmless substrates • Gastroenterology
Thereby, almost any body function can • User-friendly • Hepatology
be evaluated. • Multitasking • Nutrition control
t
emen
asur
Digestion of food and enzyme activity
Me
C-Mixed Triglycerides breath test:
13
m
r
Metabolism of fat by checking lipase activity of the pancreas. rfo
Pe
Ca l c u l a t
charides like starch and glycogen are hydrolysed by the enzyme
amylase.
eR
Lactose (naturally enriched 13C) breath test: ul
es
t
Check for the enzyme lactase for digestion of milk sugar (lactose).
Lactase deficiency.
report
C-Bicarbonate breath test:
13
D F-
energy consumption during the test phase (dependent on activity
tP
and health status). Thereby also a rise in REE (Resting EE) caused
rin
by some diseases (inflammation diseases, sickle cell disease, HIV) P
δ C
can be addressed.
13
CO2