LCD Hall Cullen Meter Current Voltage Power Electric Energy Meter
Technical Parameters
Model WLS-PVA200
black red yellow
Current measuring
range 200A
Capacity measuring
range 0〜999AH
When the measured voltage is over DC 5-90V, this meter must
Power measuring be connected with three-wire system connection. A separate
range 0〜999KW power supply is needed for this meter. As the following picture
shows:
Electric energy Normally, the controller of electric bike has a 12V or 5V output,
measuring range 0〜999KWH
you can use it as power supply.
Measurement error ±1%
red
Refreshing speed 0.5S/time
Installing size 76.0mm * 39.5mm
DC5-100V
Diameter of power supply
Φ20mm
transformer
Working current Backlight on:10MA;Backlight off:4MA
black yellow
Wiring instructions:
+
battery load or
T h i s m e t e r, w i t h 3 w i r e s , a l l o w s t o b e p o w e r e d b y w i d e controller
- Triangle icon on the
voltage range and has a wide voltage measuring range. If the transformer will point to
measured voltage is DC 5-90V, you can use two-wire system load’s direction when
measuring positive lead.
connection to make it work, which is easy and simple. There
are 3 wires on the back of meter, as following:
The above pictures show the wiring method for those that
(1) Black wire is for power supply -
charging port and discharging port are the same one. If they
(2) Red wire is for power supply +.( Note: power supply range don’t share the same port, you need to make the positive of
must be DC 5-90V, or this meter will be burnt.) charging cable go through the hole of transformer.
(3) Yellow wire is for the input lead wire of the measured
voltage, it have to be connected to the lead wire of the
measured voltage.
Special Note:
1. Correct wiring method: Cullen meter display positive current
When the measured voltage is DC 5-90V, this meter can be when discharging and display negative current when
connected with two-wire system connection. Making the red charging. If not, that means you connected the transformer
wire and yellow wire in parallel and then connect it to the
positive of battery. As the following picture shows: ( Note: if in wrong direction.
you input voltage is higher than 80V, please add ventilation 2. Newly installed Cullen meter need to clear current when
and cooling; and also we suggest to add separate power no load connected.
supply for this meter.) 3. When the newly installed Cullen meter has been set battery
capacity and automatically filling the voltage when fully
charged, you need to make battery fully charged again,
then it can display remaining capacity.
4. Please keep this meter away from water, or it will be burnt.