0% found this document useful (0 votes)
24 views1 page

QC220329-11 Retort - 900

This document is a calibration certificate for a retort tester owned by Daqing Drilling Company in Basra, Iraq. The certificate provides details of the equipment, environmental conditions during testing, calibration method, traceability, and test results. The retort tester was calibrated by Quality Control Labs in accordance with their standard procedures. Test results showed the equipment measurements were found to be okay. The certificate is valid until March 28, 2023.

Uploaded by

Yahya Tarek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

QC220329-11 Retort - 900

This document is a calibration certificate for a retort tester owned by Daqing Drilling Company in Basra, Iraq. The certificate provides details of the equipment, environmental conditions during testing, calibration method, traceability, and test results. The retort tester was calibrated by Quality Control Labs in accordance with their standard procedures. Test results showed the equipment measurements were found to be okay. The certificate is valid until March 28, 2023.

Uploaded by

Yahya Tarek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ω 9拟π 斑 ‰Bmu1Commny For n咖 1eer吨

Q1I多 n饣 c。 nml~IF:q
sα吣 $

CaI:bm〃 o″ C匕 r〃刀匕臼fe
AI Takamul Yard,Nor山 Rumailah soⅡ tll Iraq
。ph。 ne:+96478】 0009138● lvi1。 lv quaⅡ tvronmo⒈ iraq ronl● E-mal⒈ op@quali,rontro← ilaq coⅢ
Date of Issue; lmarch29,2022 Page l of1

NuMBER ∶ QC/JN`22`0084

CUsTOlVIER DETAILs
Nallle RAQ
∶Daqing Dr:Ⅱ ing Company Ι (Mud Un:t)
Λddress ∶Basla,solIth araq
EQtiIPMENT1DENTIFICATIoN AND sPECIFICAT】 oNs
DesCription ∶Retort Tes‘ er
汀anufadurcr
卜 ∶oFITE
Model ∶I65ˉ 80ˉ l
seriaI Numbcr ∶900
Max Mud Sa lplc ∶ 20ml
Cahbldlcd By ∶Abdul讪 man△ 唧
CalibIatlon Date 犭arch29,2022
∶小
Calibration19ue : IⅥ arCh28,2023
ENV1RONlljENTAL CoNDITIoNs DURINC TEsT
Ambicnt Tcmpcraturc ∶ 222° C ± 1s° C
Rcl扯 ive Humiditv : 519%RH ± 23%RH
CALIBRATIoN hIETⅡ oI,
The above equipment has been。 ahbratcd in Ⅱ cordanoc w“ h Dubai Munoipalio staltdard,C・ alibI/ation Proccdurc # sOP-QC-C TO7
The devidtions ofthc mcasuIcmcnts obta】 ned fIom UUC with rcspcd to lcference standalds are determ】 ned to obtaln the cllor
TRACEABILITV
Thc nleasu虍 mellts madc by QuaI"y Contld Labs are traceable lo Alllα ek,vide Cal Cclt# :20123042
灬ˇ
Thc measurements madc by Qualiˇ Contol Labs,lcalizc tlle physical units ofmeasurcments ls1J,tllfough its statc of
thc a"calibration standards that alc ooIltrollcd and maitltained by QC

DEsCRIPTIoN 卜刂AkE ~Ι oDEL# sER1AL# CERTIFICATE# TRACEABILITY


K1、 pc ThCmOcOup1c PATOs DE305 GO009036 AW o0123042 ALˉ Wallrail Basra IRAQ

CALIBRATIoN TEsT REsU△ Ts

Tcst And FounfOK

~END OF DOCUMENT~

lr沁 cc″ l・ crl把 ls isslfcd忉 日CCordα 勿 乃°昭 ro〃 曰ccrC涉 砌 ″o″ 沼 日 cJ’I纟 ″沁 Csper fso/JFC'702,20`7
ˉ "Ce w`r/lr9l纟 'l’
砀 沁 四 ″ 。馆 y″ o`0e lePlodjl四 ′ 。fhc/thgn j″ 丿%JJ″ ″汩 $Pε r/JlJ9slo″ ro'助 e pIfD″ c口扌汩 ″ oFaJl。 pp∞ 昭
lll日 ⒇ 扌乃鲋 沙留 ″ o乃 ″ 初 e〃
初 Ⅱ.″ g户
`・
olll/he菡 r怦c`o严 犭 oC J/'昭 s″ ° re ro r/le sj`缸 召cr盯 功 e臼 ″a汨 f`。 `c霪
,ly曰 r″ 00'弪 s oe,o,,Jf/9os's乃 ow″ Ⅱ
`l。
r/召 〃曰忽 c口 ″″ ll召 d乃 召犯 加 `or|r,CfJJFP″ "口

・蠛

伽Ⅱ 惭d
嘁 ⑧ ① 目 薷 御 ‰…
=糖
:栈嬲 糨 T%h涮

You might also like