Fire Simulation Using FDS (Fire Dynamics Simulator) : Egi-Inspire
Fire Simulation Using FDS (Fire Dynamics Simulator) : Egi-Inspire
• FDS Support
• To automate the process of simulation runs, for
each configuration an fds-manager script was
created which provides for the following actions:
• it accepts and checks input arguments specifying the
FDS input file and cluster configuration (the number of
nodes, cores, and eventually the number of MPI
processes and OpenMP threads)
• it produces an fds-submission script which serves as
an input to the Portable Batch System (PBS)
• it realizes the execution of the FDS simulation using
the previously generated job-submission script
• FDS Running
• Experiments are carried out on the HP blade
cluster of the configuration:
• 16 blade nodes, each comprising of 2 quad-core
CPU Intel Xeon X5570@ 2.9GHz, 24-48GB RAM,
500GB hard disk
• 6 nodes are interconnected by the Infiniband
network (40Gb/s)
• 10 nodes are interconnected by the Ethernet
network (4Gb/s)
• Disk storage: 48 TB disk array
Amsterdam, 24-26, 2012 8
EGI-InSPIRE RI-261323 www.egi.eu
FDS Simulation
• FDS Input
• FDS reads input parameters from a single
text file which provides all the necessary
information to describe the fire scenario.
• The computational domain representing the
given fire scenario included 12-25 millions
rectangular mesh cells dependent on the
resolution.
• Simulations with the given fire scenario
consumed 8-48GB RAM.
Amsterdam, 24-26, 2012 9
EGI-InSPIRE RI-261323 www.egi.eu
FDS Simulation
• FDS Output
• The numerical solution to the governing
equations is written to various types of files. All
output quantities must be explicitly declared (in
the input file) at the start of the calculation.
• Simulations with the given fire scenario
produced output data files of amount 7-20GB.
• The simulation result can be visualized using the
Smokeview program that reads FDS output files
and produces animations on the computer
screen.
Amsterdam, 24-26, 2012 10
EGI-InSPIRE RI-261323 www.egi.eu
FDS Simulation
• Fire Scenario
• We have constructed a model of a two-lane road
tunnel with dimensions 10x180x7m with 2 fans
located on the tunnel ceiling at the distance 50m and
140m from the left entrance.
• The fire source was represented by burning of a
flammable liquid in a pool with dimensions 2x3m
placed in the distance 92m from the left entrance of
the tunnel, 1.1m above the floor level.
• The initial air temperature in the whole tunnel was
set to 20°C.
• The total duration of the simulation was 150s.
Amsterdam, 24-26, 2012 13
EGI-InSPIRE RI-261323 www.egi.eu
FDS Simulation
4
3
2
1
• Computational Requirements
Resolution 20 cm 10 cm 5 cm
Cells Number 1,62 mil. 12,96 mil. 103,68 mil.