Central Medical Gas: Distribution System
Central Medical Gas: Distribution System
Distribution System
WHAT IS CENTRAL MEDICAL GAS DISTRIBUTION SYSTEM?
1
ADVANTAGES OF CENTRALISED MEDICAL GAS
DELIVERY SYSTEM
2
TYPES OF MEDICAL GASES
• Oxygen- used for respiratory therapy and life-support • Helium/oxygen mixture is used to treat patients with
and is additionally used in anaesthetic procedures. respiratory or airway obstruction.
• Medical air-This is supplied by a specialized air •Carbon dioxide in used in the medical world to aid
compressor to patient care areas. Used extensively in laparoscopic examination. The carbon dioxide inflates the
the ICU, PICU, and NICU areas, to reduce the risk of stomach slightly which simplifies internal visibility inside
excess oxygen in the lungs, during surgical procedures. the abdomen.
• Surgical air is used, at a higher pressure, to power a • Piped vacuum or Suction is provided by means of
variety of surgical tools and other devices. centrally sited vacuum pumps & supports evacuation
procedures.
• Nitrous oxide is used for anaesthetic and analgesic
purposes.
3
USAGE OF MEDICAL GASES COLOUR CODING
4
MEDICAL GAS PIPELINE SYSTEM
COMPONENTS
5
1.MEDICAL GAS PIPELINE 2. SHUT OFF VALVE
• Shut off valve system is
A pipeline system is a system that
used on each floor of the
includes; hospital or on the entrance
The pipeline network of the gas port of the
operation room
The control unit and
The piped material should be copper • It main has two functions:
seamless tubes. To reduce gas pressure and
to shut off gas pipes.
These terminal gas outlets are colour-coded, labelled with gas name
and have self-sealing sockets.
Gas specificity- The terminal unit shall only accept the probe for the
gas for which it is intended.
7
TYPES OF TERMINAL GAS OUTLETS
Outlets can be installed as flush fitting units, surface-fitting units on booms or pendants,
suspended on a hose and gang mounted.
Hanging From Ceiling Ceiling column & pendent Bedhead Unit
Medical Hanger
Type Outlet
MANIFOLD ROOM
Consists of a cylinder manifold and a control
panel
Manifold can be of 2 banks of 2 cylinders each or
2 banks of 20 cylinders each.
Control panel: primary and secondary pressure
regulations: warning lamp.
9
Gas Cylinders Cylinder Manifold
12
PIPELINES
13
GAS OUTLETS
BED HEADS
PIPELINES
SHUTOFF VALVES
14
MEDICAL GAS ALARM
BED HEADS
15
WHY CHOOSE ONSITE GAS GENERATORS?
ON SITE GAS PRODUCTION
16
THE PRESSURE SWING ADSORPTION
(PSA) PRINCIPLE
• PSA (pressure swing adsorption) is an • Ambient air entering the compressors is 78% nitrogen, 21%
economical alternative for onsite oxygen, less than 1% argon and other gases.
production of oxygen for medical use
and is in use for over 30 years in the • As nitrogen is separated, the resulting product gas is up to
medical industry. 95.5% oxygen purity.
17
THE PRESSURE SWING ADSORPTION PROCESS
18
CAPACITY- 900 LITRE FEATURES
19
CAPACITY- 5500 LITRE FEATURES
20
THANK YOU