Design Calculation For Raising Plateform
Design Calculation For Raising Plateform
Project:
Location
Contractor :
DYNAMIC MOTION
Job No Reference:
CAL01/2247/01/04 R0
Prepared by:
TECHNICAL DESIGN DEPARTMENT
Project: Location: Job No. :
RAISED SITTING PLATFORM
KINGDOM OF SAUDI ARABIA
Contractor: Dwg. Ref No: Sheet No. / Rev.
DYNAMIC MOTION
/
Calc by: Date: Checked by: Date:
CALCULATION SHEET
21/10/2022 21/10/2022
Introduction
This calculation should be read in conjunction with accordance with the codes of practice listed below, where
relevant. The specific guidance note used for the specification and design of scaffolding equipment is TG20:13
Technical guidance on the use of BS EN 12811-1:2003 and BS EN 12810-2:2004
Material Properties
Cuplock Scaffold (for Standard and ledgers)
Diameter of tube d = 48.30 mm
Nominal wall thickness t = 3.20 mm
Elastic modulus E = 210000 N/mm2
Yeild Strength fy = 235.00 N/mm2
Area of section A = 453.39 mm2
Moment of Inertia I = 115857 mm4
Radius of Gyration r = 15.99 mm
Plastic Modulus, Wpl = 6519.75 mm3
Length (mm) Load (KN) Length (mm) Load (KN) Length (mm) Load (KN)
1000 48.1 2600 16.1 4200 7.0
1200 42.8 2800 14.3 4400 6.4
1400 37.5 3000 12.7 4600 5.9
1600 32.5 3200 11.3 4800 5.5
1800 28.0 3400 10.2 5000 5.1
2000 24.2 3600 9.2 5200 4.7
2200 21.1 3800 8.4 5400 4.4
2400 18.4 4000 7.6 5600 4.1
l = l / (P 2 E /fy)1/2
= 1.00
1
x = 0.5
F + ( F 2
- l 2
)
= 0.54
Pc = 57.58 kN / 1.65
= 34.9 kN
2.0 24.25
2.5 17.21
3.0 12.69
Important Note
Scaffolding components will be designed based on safe working loads as stipulated in our attached technical data.
Design Load
Wind Load
Wind Code refers basic wind speed to ASCE 7-05, in order to move from ASCE 7-05 to
ASCE 7-10 basic wind speed shall be multiplied to the square root of 1.6 (same factor adopted in load ASCE 7-05 load
combination).
ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures
Wind Load on Buildings-MWFRS (Directional Procedure)
ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures
Wind Load on Buildings-MWFRS (Directional Procedure)
Design Load
Wind Load
Vref: 11.00 m/s (recommended maximum wind speeds for one off emergency work only from a completed scaffold)
* Chartered Institute of Buidling Publication (Access Scaffolding) 2002 page 23
Factor adopted to taking into account of the reducted return period due to erection phase : 0.8
(According to ASCE 37-02)
Wind Code refers basic wind speed to ASCE 7-05, in order to move from ASCE 7-05 to
ASCE 7-10 basic wind speed shall be multiplied to the square root of 1.6 (same factor adopted in load ASCE 7-05 load
combination).
ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures
Wind Load on Buildings-MWFRS (Directional Procedure)
ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures
Wind Load on Buildings-MWFRS (Directional Procedure)
Calculate Safe Working Moment of Scaffold Tube Ref. EN 1993 2005 Table 5.2 / 6.2.5
Check Classification:
e = 1.0 gMo = 1.65
d / t 50 e2
0.00 < 50.0 Therefore Class 1 Cuplock System Scaffold
Calculated Load
Dead Load = 0.04 kN/m2 x 0.900 m = 0.039 kN/m(board selfweight)
Live Load = 5.00 kN/m2 x 0.900 m = 4.500 kN/m
Wind Load = 0.10 kN/m2 x 0.450 m = 0.045 kN/m
Weight = 0.044 kN/m
Total UDL = 0.089 kN/m
Reaction = 0.089 kN/m x( 1.600 m) / 2 = 0.07 KN
Check Transom Subjected to Self weight, Live Load and Wind Load
MUDL = wL²/8
= 0.089 kN/m x( 1.600 m)2 / 8
MUDL = 0.028 kN-m < 0.93 kN-m Therefore: Safe
STAAD Analysis
MODELLING
STAAD Analysis
Load Application
Dead Load
Scaffold Selfweight
Service Load
1.60KN every Nodes on the game
Live Load
5 KN/m^2
Max Anticipated Load = 7.12 kN < 34.00 KN (using 2600 mm Galvanized Tube In Good Condition )
Therefore: Safe
Max Anticipated Load = 3.46 kN < 34.90 KN (using 1500 mm Cuplock Scaffold )
Therefore: Safe