114 MLS Capacitance Type For Solids
114 MLS Capacitance Type For Solids
APPLICATIONS:
Detecting / Controlling level of dry / moist,free
flowing solids like Cement, clinker, limestone,
coal, fly ash,foundry sand, iron ore,nylon / PVC
chips, pellets, food grains, etc.
FEATURES:
Surface/Pipe mounting versions
Built in Time delay and probe failure
(Optional)
One point switch.
SPECIFIACTIONS:
CONTROLLER UNIT :
Power supply: 115 VAC/ 230VAC/24VDC.
Relay contacts:
2 C/O, 5A @ 230VAC,Resistive
Versions:
1 – Level alarm (With time delay)
2 – Level and probe failure alarm ( Optional )
Fail safe feature: Cable entries : 1/2” NPT(F), ¾” UNF (F)
DIP switch settable fail safe high (FSH) or fail Location:
safe low (FSL) Suitable for installation in safe area.
Time delay: Enclosure:
0 – 200sec Cast aluminum, Polyurethane painted,
Controls: Weatherproof to IP-65
Potentiometers to set : Level Alarms.
: Time Delay. ELECTRODES :
DIP-For setting level alarms.
Indications:
Electrode Duties
Red LED for Level Alarms Bi-Color LED for
Bi-colour LED for level above set point. Rigid Partially grounded
Dry solid, Nylon/PVC
Red LED for Probe failure ( Optional ). Dia.27 mm PTFE chips & pallets, food
Sensitivity: Insulated. grains,etc.
± 0.5% of probe output Coat safe PTFE Moist, free flowing
Environmental conditions:
Insulated solids,Cement,Fly ash,
Temperature : -10º C to + 60º C Bag filler,ESP Hoppers.
Relative Humidity : 0 % to 95 % Coatsafe high Tempera- Fly ash, Clinker
(Non condensing) ture alumina insulated
Terminals: GI Wire Rope Electrode Dry Solids
Suitable for 1.5 sq. mm size conductor (Max)
(Refer Note. 5)
--- 1 ---
ORDERING CODE :
Process
Switch connection Electrode Electrode length
114 MLS - L=
Construction: L=XXXX
I - Integral Weatherproof Electrode length
Remote head Weatherproof
S-Surface mounting with remote head
P-Pipe Mounting with remote head
Safty:
H-Non Intrinsically
safe. Electrode code:
00 - Not applicable
XX - Refer table
Versions:
1-One Pt.
2-One Pt.+ PF Alarm
Process connection:
00 - Not applicable
Cable entry: 01 - 1” BSP(M)
T-1/2” NPT (F) 02 - 1 1/2” BSP(M) (Ref.note 1&2)
F- 3/4” NPT (F)
Note:
Power Supply: 1.Slip on flange of appropriate size order
0 - Not applicable separately.
1 - 230 VAC
2 - 115 VAC 2. Size of process connection is strictly as per
3 - 24 VDC electrode selection guide.
ELECTRODE SELECTION GUIDE :
ELECTRODE
PROCESS OPERATING
LENGTH
CONNECTION CONDITIONS
MOC OF CONST TRANS (`L`mm)
CODE ELECTRODE SERVICE MTG. HYS.
NO. DESCRIPTION THD. SENSING RUCTION DUCER TEMP. PRES.
V mm.
ELECTRODE IN IN
I/R H MIN. MAX. TYP. 0 Kg/cm2
C
MAX. MAX.
Notes:
1. Separate ordering code for controller and Electrode is required for Remote mounting (Refer page 4)
2. V/H Indicates mounting orientation : V=Vertical, H= Horizontal.
3. I/R indicates construction :I= Integrated,R= Remote i.e 2 part system seperate switch and probe unit.
4. Hysterisis varies as per process material sensed.
5. High temperature stand off (HTSO) is recommended for process temperature above 600 C
HTSO in SS 316 : 600C to 1800C,HTSO in CS & SINDANO : 1800C to 3000C.
Remotely mounted transducer housing : 3000C to 6000C.
6. Cable between Probe head and Controller is 4 core shielded Tinned copper multistrended 3 X 0.5 sq.mm.
100 Mtr.( Max.).
7. Slip on flanges with suitable threaded hole in required material e.g. CS/SS316/SS304,available optionally.
8. Size of Process connection as per “Electrode Selection Guide”.
DIMENSIONAL DETAILS :
COAT-SAFE PRINCIPLE :
Normal probe may not perform satisfactorily if the
process material builds up on the probe to a significant
degree. The `coat-safe` electrode is designed to
overcome this problem. In this type of electrode, in
addition to the primary sensing electrode, a secondary
`coat-shield` electrode, insulated from ground &
primary electrode is used. This electrode is driven with
signal of equal phase & amplitude as primary electrode.
Hence when there is a coating / material buildup on
electrode , no current flows between primary &
secondary electrode. The electronic in strument
measures the current that flows from primary electrode
to ground. This means that build up is ignored.
Only when the product level in the vessel rises & covers
the primary electrode, it causes a current to flow which
is sensed, demodulated, amplified & causes the switch
to changeover.
--- 3 ---
Example of model code selection for Integral Mounting.Model no.: 114 MLS IH1T1 01 92 L=0600
The above model code specifies that Capacitance Type Level Switch 114 MLS with Integral mounting,Non-intrinsically
safe single point having cable entry of 1/2” NPT(F) & Power supply of 230 VAC.Process connection for this switch is
1” BSP(M) & Electrode is of following type i.e. Coatsafe PTFE insulated having length of 600 mm.
Model code selection for remote mounting switch and probe has to be seperately ordered.
Controller: Model No.: 114 MLS SH1T1 00 00 XXXX
Capacitance type level switch 114 MLS Surface mounting,Non-intrinsically safe single point having cable entry of 1/2”
NPT(F) & power supply of 230 VAC.
Electrode: Model No.: 114 MLS XXXX0 01 95 0600
Coatsafe PTFE insulated having 1” BSP(M) process connection & 600 mm Length.
APPLICATION DRAWINGS :
*** Continuous developments may necessitate changes without notice. LF-114-0807 Rev.03 05/2009
--- 4 ---