Datos PB 24-03-23
Datos PB 24-03-23
Datos PB 24-03-23
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Test Conducted by: Augusto Ramirez Test Date: 24/03/2023 Discharge: variable, average rate 6,0958 [l/s]
Observation Well: Well 1 Static Water Level [m]: 20,10 Radial Distance to PW [m]: -
Time Water Level Drawdown
[min] [m] [m]
1 0 20,10 0,00
2 0,5 23,85 3,75
3 1 24,50 4,40
4 1,5 24,77 4,67
5 2 25,00 4,90
6 2,5 25,20 5,10
7 3 25,35 5,25
8 3,5 25,50 5,40
9 4 25,63 5,53
10 4,5 25,77 5,67
11 5 25,85 5,75
12 6 26,10 6,00
13 7 26,30 6,20
14 8 26,50 6,40
15 9 26,65 6,55
16 10 26,80 6,70
17 12 27,15 7,05
18 14 27,40 7,30
19 16 27,60 7,50
20 18 27,82 7,72
21 20 28,00 7,90
22 25 28,45 8,35
23 30 28,82 8,72
24 35 29,13 9,03
25 40 29,45 9,35
26 45 29,73 9,63
27 50 29,98 9,88
28 55 30,21 10,11
29 60 30,50 10,40
30 70 30,95 10,85
31 80 31,32 11,22
32 90 31,66 11,56
33 100 31,93 11,83
34 120 32,33 12,23
35 140 32,64 12,54
36 160 32,93 12,83
37 180 33,15 13,05
38 200 33,38 13,28
39 220 33,57 13,47
40 240 33,65 13,55
41 260 33,86 13,76
42 280 34,05 13,95
43 300 34,20 14,10
44 330 34,40 14,30
45 360 34,59 14,49
46 390 34,65 14,55
47 420 34,86 14,76
48 480 35,20 15,10
49 540 35,56 15,46
50 600 35,86 15,76
51 660 36,10 16,00
52 720 36,40 16,30
53 780 36,67 16,57
54 840 37,00 16,90
55 900 37,20 17,10
56 960 37,40 17,30
57 1020 37,60 17,50
Contact Info Pumping Test - Water Level Data Page 2 of 3
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Time Water Level Drawdown
[min] [m] [m]
58 1080 37,85 17,75
59 1140 38,10 18,00
60 1200 38,35 18,25
61 1260 38,50 18,40
62 1320 38,75 18,65
63 1380 38,93 18,83
64 1440 39,10 19,00
65 1440,5 36,20 16,10
66 1441 35,90 15,80
67 1441,5 35,72 15,62
68 1442 35,60 15,50
69 1442,5 35,44 15,34
70 1443 35,32 15,22
71 1443,5 35,22 15,12
72 1444 35,15 15,05
73 1444,5 35,08 14,98
74 1445 35,00 14,90
75 1446 34,90 14,80
76 1447 34,85 14,75
77 1448 34,73 14,63
78 1449 34,70 14,60
79 1450 34,64 14,54
80 1452 34,50 14,40
81 1454 34,48 14,38
82 1456 34,39 14,29
83 1458 34,34 14,24
84 1460 34,27 14,17
85 1465 34,15 14,05
86 1470 34,05 13,95
87 1475 34,00 13,90
88 1480 33,82 13,72
89 1490 33,78 13,68
90 1500 33,71 13,61
91 1510 33,65 13,55
92 1520 33,58 13,48
93 1530 33,45 13,35
94 1540 33,34 13,24
95 1550 33,22 13,12
96 1560 33,10 13,00
97 1580 32,95 12,85
98 1600 32,78 12,68
99 1620 32,64 12,54
100 1640 32,50 12,40
101 1660 32,40 12,30
102 1680 32,27 12,17
103 1700 32,16 12,06
104 1720 32,06 11,96
105 1740 31,95 11,85
106 1770 31,84 11,74
107 1800 31,70 11,60
108 1830 31,64 11,54
109 1860 31,50 11,40
110 1890 31,42 11,32
111 1920 31,30 11,20
112 1950 31,10 11,00
113 1980 30,90 10,80
114 2010 30,80 10,70
115 2040 30,67 10,57
116 2100 30,57 10,47
117 2160 30,45 10,35
118 2220 30,35 10,25
119 2280 30,26 10,16
Contact Info Pumping Test - Water Level Data Page 3 of 3
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Time Water Level Drawdown
[min] [m] [m]
120 2340 30,16 10,06
121 2400 30,06 9,96
122 2460 29,96 9,86
123 2520 29,84 9,74
124 2580 29,74 9,64
125 2640 29,65 9,55
126 2700 29,54 9,44
127 2760 29,46 9,36
128 2820 29,40 9,30
Contact Info Pumping Test Analysis Report
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Location: - Pumping Test: Prueba Constante Pumping Well: Well 1
Test Conducted by: Augusto Ramirez Test Date: 24/03/2023
Analysis Performed by: Augusto Ramirez Jacoob y Cooper Analysis Date: 5/04/2023
Aquifer Thickness: 33,00 m Discharge: variable, average rate 6,0958 [l/s]
Time [min]
1E2 1E3 1E4
0,00
4,00
Drawdown [m]
8,00
12,00
16,00
20,00
Well 1
Calculation using COOPER & JACOB
Observation Well Transmissivity Hydraulic Conductivity Storage coefficient Radial Distance to PW
[m²/d] [m/d] [m]
1 -1 -1
Well 1 2,32 × 10 7,02 × 10 4,76 × 10 0,08
Contact Info Pumping Test Analysis Report
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Location: - Pumping Test: Prueba Constante Pumping Well: Well 1
Test Conducted by: Augusto Ramirez Test Date: 24/03/2023
Analysis Performed by: Augusto Ramirez Theis Analysis Date: 5/04/2023
Aquifer Thickness: 33,00 m Discharge Rate: 6 [l/s]
1E1
1E0
Well 1
Calculation using Theis
Observation Well Transmissivity Hydraulic Conductivity Storage coefficient Radial Distance to PW
[m²/d] [m/d] [m]
1 -1 -1
Well 1 2,30 × 10 6,97 × 10 5,00 × 10 0,08
Contact Info Pumping Test Analysis Report
Address
Project: -
Company Name
City, State/Province Number: -
Client: -
Location: - Pumping Test: Prueba Constante Pumping Well: Well 1
Test Conducted by: Augusto Ramirez Test Date: 24/03/2023
Analysis Performed by: Augusto Ramirez Theis Recovery Analysis Date: 5/04/2023
Aquifer Thickness: 33,00 m Discharge: variable, average rate 6,0958 [l/s]
t/t'
1E0 1E1 1E2 1E3 1E4 1E5
1E1
residual drawdown [m]
2E1
3E1
3E1
4E1
5E1
Well 1
Calculation using THEIS & JACOB
Observation Well Transmissivity Hydraulic Conductivity Radial Distance to PW
[m²/d] [m/d] [m]
1 0
Well 1 4,46 × 10 1,35 × 10 0,08