0% found this document useful (0 votes)
263 views3 pages

HT Yard BOM

The document provides a bill of materials (BOM) for 33 KV/433 V substations and metering yards. It includes quantities and specifications for various items like 33 KV air break switches, current transformers, potential transformers, cables, conductors, busbars, cable glands and lugs required to set up the substations and metering infrastructure. A total of 26 line items with descriptions and quantities of equipment, accessories and materials are listed in the BOM.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
263 views3 pages

HT Yard BOM

The document provides a bill of materials (BOM) for 33 KV/433 V substations and metering yards. It includes quantities and specifications for various items like 33 KV air break switches, current transformers, potential transformers, cables, conductors, busbars, cable glands and lugs required to set up the substations and metering infrastructure. A total of 26 line items with descriptions and quantities of equipment, accessories and materials are listed in the BOM.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

33 KV/433 V Substations & Metering yards

BOM

s.no Description of the material Qty


1250 A,33 KV, Double break, centre rotating, horizontal
1. gang operated air break switches (AB switches)
1. With earth switch AB switches
2. Without earth switch AB switch 2 No’s
2 No’s
2. 800 A,33 KV, Double break, centre rotating, horizontal
gang operated air break switches (AB switches)
1. With earth switch AB switches
2. Without earth switch AB switch 2 No’s
1 No’s

3. 30 KV, 10 KA, Line type, class – 3, porcelain Lighting 15 No’s


Arresters

4. 33 KV , porcelain Disc Insulators 3 No’s

5. 33 KV , porcelain post top Insulators 6 No’s

6. 33 KV, Current Transformers


Type : outdoor (live tank type)
Normal system voltage : 33 KV
Rated system voltage : 36 KV 3 No’s
STC (Short Time Current) : 25 KA/ 1 Sec ( Metering Yard)
Ratio : 200/ 1A
Class : 0.2 s
Burden : 10 VA
No. of. cores : 1

7. 33 KV, Current Transformers


Type : outdoor ( live tank type)
Normal system voltage : 33 KV
Rated system voltage : 36 KV 3 No’s with standard
S T C ( short time current) : 25 KA/1 Sec Frame suitable for out
Ratio : 200/ 1 A Door installation at
Class : 5P20 Height of 3.8 mtrs from
Burden : 20 VA The ground level.
No. of. Cores : 1
8. 33 KV, Current Transformers
Type : out door( live tank type)
Normal system voltage : 33 KV
Rated system voltage : 36 KV
S T C (short time current) : 25 KA/ 1Sec 3 No’s with standard
Ratio : 200/ 1-1 A Frame suitable for out
Class : CORE-1: 0.2 S Door installation at height
CORE-2: 5P20 Of 3.8 mtrs from the
Burden : CORE-1: 10 VA Ground level.
CORE-2: 20 VA
No. of. Cores : 2

9. 33 KV, Current Transformers


Type : out door( live tank type)
Normal system voltage : 33 KV 6 No’s with standard
Rated system voltage : 36 KV Frame suitable for out
S T C (short time current) : 25 KA/ 1Sec Door installation at height
Ratio : 100/ 1-1-1 A Of 3.8 mtrs from the
Class : CORE-1: 0.2 S Ground level.
CORE-2: 5P20 (Required two sets)
CORE -3 : PS
Burden : CORE-1: 10 VA
CORE-2: 20 VA
No. of. Cores : 3

10. 33 KV Potential Transformers


Type : out door (live tank type)
Normal system voltage : 33 KV
Rated system voltage : 36 KV
STC : 25 KA/ 1 SEC 3 No’s
Ratio of primary volts : 33 KV/ √3 (Metering Yard)
Ratio of secondary volts : 110 v / √3
Class : 0.2 S
Burden : 50 VA
No.of cores : 1
Insulation level : 75/170 KV
Type of cooling : out door oil cooled

11. 33 KV Potential Transformers


Type : out door ( live tank type)
Normal system voltage : 33 KV
Rated system voltage : 36 KV
STC : 25 KA/ 1Sec
Ratio of primary volts : 33 KV/√3 3 no’s with standard Frame
Ratio of secondary volts : 110V/√3 – 110V/√3 suitable for out Door installation
Class : CORE-1: 0.2 at height Of 3.8 mtrs from the
CORE-2: 3P ground level
Burden : CORE-1: 15 VA
CORE-2: 50 VA
No. of cores : 2
Insulation level : 75/170 KV
Type of cooling : OUT DOOR OIL COOLED

12. 38 mm dia, 5 mm thickness, aluminium tubulor 150 mtrs


conductor

13. 3core*300 sq mm , 33KV-E-HT-XLPE Insulated, 480 mtrs


aluminium armoured cable

14. 3 core*300 sq mm,33 KV, Outdoor, Heat shrink cable 12 kits


end kits with heavy duty long aluminium lugs

15. 75*10 mm EC grade copper flat 35 mtrs


16. 25*6 mm EC grade copper flat 200 mtrs
17. 50*6 mm hot dip G.I. flat 250 mtrs
18. 25*6 mm hot dip G.I. flat 100 mtrs
19. 100*10 mm hot dip G.I. flat 60 mtrs
20. 50*10 mm hot dip G.I. flat 100 mtrs

21. 12C*2.5sq mm, copper ,armoured, multi strand cable 300 mtrs
22. 4C*2.5sq mm, copper ,armoured, multi strand cable
300 mtrs

23. Conical Busbar insulator supports (red colour )


Top dia : 30 mm
Bottom dia : 40 mm
Length : 40 mm 200 No’s
Both sides 8 mm threaded holes

24. 28,25 and 22-mm single compression cable glands. 25 No’s (each sq.mm)
25. 4 sq. mm copper ring and pin type lugs. 80 No’ s each type
26. 2.5 sq. mm copper ring and pin type lugs. 120 No’s each type