CB Layout Plan 1: A B C D Official Use Only

The document contains a technical drawing showing the layout and dimensions of concrete beams labeled A through D, with reinforcing bars and ties. Beams A and B are 15'7" long, while beams C1 through C3 range from 7'6" to 9'2" long. The drawing specifies requirements for placement of special confining ties and lateral ties between the beams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views1 page

CB Layout Plan 1: A B C D Official Use Only

The document contains a technical drawing showing the layout and dimensions of concrete beams labeled A through D, with reinforcing bars and ties. Beams A and B are 15'7" long, while beams C1 through C3 range from 7'6" to 9'2" long. The drawing specifies requirements for placement of special confining ties and lateral ties between the beams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

official use only

A B C D TOP FLOOR
Ld

Ld
1' - 0" 15' - 7" 1' - 2" 8' - 1" 1' - 0" 6' - 6" 1' - 0" JOINT TIE
16' - 8" 9' - 2" 7' - 6" North
C3 C2
C1

1' - 0"
4

5' - 0"

5' - 0"
C1

SPECIAL CONFINING TIES


1' - 0"
3
15' - 3"

h
THE LENGTH h SHALL NOT BE LESS THAN
1. LARGE LATERAL DIMENSION

10' - 3"
11' - 4"

11' - 4"
2. 1/6 OF CLEAR SPAN
3. 450mm

JOINT TIE
z

SPECIAL CONFINING TIES


C3 C3 C3
1' - 2"

1' - 2"
2

h
10' - 10"

10' - 10"
9' - 9"

9' - 9"

SPECIAL CONFINING TIES


WHERE LAP IS PROVIDED
LATERAL TIE
C2 C2 C2 SPACING OF LATERAL TIE

BUT

H
1' - 0"

1' - 0"
SHALL NOT EXCEED 0.5TIMES
1 LEAST LATERAL DIMENSION
16' - 8" 9' - 2" 7' - 6"

1' - 0" 15' - 7" 1' - 2" 15' - 7" 1' - 0" Jansewa Engineering
CB Layout Plan

SPECIAL CONFINING TIES


1 Consultancy & Co Pvt Ltd
1/8" = 1'-0"

h
co-reg no:
172845/074/75

JOINT TIE
Dhangadhi-2 ,Dhangadhi
A B C D

z
JOINT TIE z Name of Project: SAP -Residential Building Design for
SAME AS SPECIAL CONFINING TIE 2.5 storey
16' - 8" 9' - 2" 7' - 6"

SPECIAL CONFINING TIES


BUT FOR INTERIOR JOINTS Project Location: Ward No-3, Dhangadhi , Kailali
WHERE BEAM WIDTH IS ATLEAST
3/4 OF COLUMN WIDTH
4' - 0"

1' - 0" 15' - 7" 1' - 2" 8' - 1" 1' - 0" HALF THE SPECIAL CONFINING TIE Plot No :571 Land Area :169.31sq.m

h
BUT NOT GREATER THAN 150mm.
INCASE OF DIFFICULTY IN PROVIDING
4 CLOSED STIRRUP, U-TYPE MAY BE
PROVIDED. Dhangadhi Sub-Metro Politian City , Kailali
5' - 0"

5' - 0"
Floor Beam
9"X12" 3' - 6"
Secondary Beam Drawn By: Roshan Checked By:
1' - 0"

9"X9"
Chaudhary Er. Prakash Rawal
3 TYP. LONGITUDINAL COLUMN SECTION NEC: 24159 Civil"A"
SCALE:1"=2'-0"
Floor Beam
9"X12"
Floor Beam Floor Beam
9"X12" 9"X12" Secondary Beam
10' - 3"
11' - 4"

11' - 4"

Secondary Beam 9"X9"


9"X9"

Building Purpose: Residential


Floor Beam
9"X12"
1' - 2"

2 Longitudinal Rebar Lateral ties Owner's Name: Bhupendra Bdr Singh


Type Mark Section Size(in) Edge Rebar Middle Rebar in(2h+z) end ties in(h-2h) end ties
B/C LAYOUT,BEAM PLAN
10' - 10"

10' - 10"
9' - 9"

C1 12X12 4-Ø16 bars 4-Ø12 bars Ø8 @ 4"c/c spacing Ø8 @ 5"c/c spacing

C2 12X12, 14X14 4-Ø16 bars 4-Ø16 bars Ø8 @ 4"c/c spacing Ø8 @ 5"c/c spacing
Floor Beam C3 12X12, 14X14 4-Ø20 bars 4-Ø16 bars Ø8 @ 4"c/c spacing Ø8 @ 5"c/c spacing Drg. No.
9"X12"
1' - 0"

1 Notes:Grid-B, Grid-2 columns are of Size 14"X14" , rest are 12"X12" S.3
4' - 0"

Column Schedule Scale 1 : 96


1' - 0" 15' - 7" 1' - 2" 8' - 7" 7' - 0" 1' - 0" 3
1/8" = 1'-0"