DB 01.01.11.01 Pump G10
DB 01.01.11.01 Pump G10
DB 01.01.11.01 Pump G10
Technical Data:
Air drive pressure: 1-10 bar / 14,5 - 145psi
Calculated Outlet Pressure at an air drive of 110 bar/ 1,095 psi
10 bar/145 psi:
Pressure ratio: 1:11
Displacement volume/double stroke 90.0cm³/ 5.49 cu.inch
Connections:
Inlet: Standard: Bottom Inlet 1 BSP
Air control units with filter pressure regulator, control pressure gauge and shut off valve: G10(L) with C2
To protect the pump against excessive outlet pressures or to limit the outlet pressure, a safety valve G10(L) with C2/SVair (The re-
can be fitted to the air control unit in the air drive line: quired outlet pressure has to be
indicated.)
Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including
limitations of our liability, apply to all products and services sold.
MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics
MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Leistungsdiagramm/Performance Graph G(SF) 10
Prüfflüssigkeit/Test Liquid: Wasser-Öl-Emulsion/Water Oil Emulsion ca. 1 - 10 cst
100 1800
8 bar 8 bar
90 1600
80 1400
6 bar
Hydraulics • Pneumatics
6 bar
70 1200
60 1000
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
4 bar
50 800
4 bar
40 600
Luftverbrauch/
Betriebsdruck/
Outlet Pressure (bar)
Air consumption (lN /min)
30 400
20 200
10 0
0 -200
0
2
4
6
8
10
12
14
16
18
Förderleistung/Flow (l/min)
MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Release 03 / 2012 • MAXIMATOR • Technical Data Sheet G10 • Page 3 of 3 • DB.01.01.11.01