DB 01.01.11.01 Pump G10

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

M a x i m u m P r e s s u r e.

High Pressure Technology • Testing Equipment


Hydraulics • Pneumatics

Technical Data Sheet G10 (L) » Oil service


G10 (L) VE » Water service

Technical Data:
Air drive pressure: 1-10 bar / 14,5 - 145psi
Calculated Outlet Pressure at an air drive of 110 bar/ 1,095 psi
10 bar/145 psi:
Pressure ratio: 1:11
Displacement volume/double stroke 90.0cm³/ 5.49 cu.inch
Connections:
Inlet: Standard: Bottom Inlet 1 BSP

Release 03 / 2012 • MAXIMATOR • Technical Data Sheet G10 • Page 1 of 3 • DB.01.01.11.01


Outlet: 3/4 BSP
Air drive: 3/4 BSP
G10 (L)
Maximum operating tempreature: 60°C
single acting, single air drive head
(Standard= Bottom inlet) Net weight: 16.0 kg
Pressure and flow performances, please see enclosed graph.

Wetted materials of construction: Seal package: G10(L): Polyurethan, NBR


G10(L)VE: UHMWPE, FKM
Pump Body: 1.4305
Piston: 1.4112 (hardened)
Fittings: 1.4571
Approximate Dimensions: Height: 311 mm
Depth: 190.5 mm
Width: 272 mm
Available Options: Seal material for oil service: G10 (L)
Seal material for water service: G10(L)VE
Side inlet G10(L)S/ G10(L)VES
Special inlet and outlet ports, i.e. NPT G10(L)-NPT
G10(L)VE-NPT
Special seal material to handle special fluids on request.
Available Accessories:

Air control units with filter pressure regulator, control pressure gauge and shut off valve: G10(L) with C2

To protect the pump against excessive outlet pressures or to limit the outlet pressure, a safety valve G10(L) with C2/SVair (The re-
can be fitted to the air control unit in the air drive line: quired outlet pressure has to be
indicated.)
Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including
limitations of our liability, apply to all products and services sold.

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics

Release 03 / 2012 • MAXIMATOR • Technical Data Sheet G10 • Page 2 of 3 • DB.01.01.11.01

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Leistungsdiagramm/Performance Graph G(SF) 10
Prüfflüssigkeit/Test Liquid: Wasser-Öl-Emulsion/Water Oil Emulsion ca. 1 - 10 cst
100 1800
8 bar 8 bar
90 1600

80 1400
6 bar
Hydraulics • Pneumatics

6 bar
70 1200

60 1000
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment

4 bar
50 800
4 bar

40 600
Luftverbrauch/

Betriebsdruck/
Outlet Pressure (bar)
Air consumption (lN /min)

30 400

20 200

10 0

0 -200

0
2
4
6
8
10
12
14
16
18

Förderleistung/Flow (l/min)

Betriebsdruck bei/Outlet Pressure at 4 bar Betriebsdruck bei/Outlet Pressure at 6 bar


Betriebsdruck bei/Outlet Pressure at 8 bar Luftverbrauch bei/Air consumption at 4 bar
Luftverbrauch bei/Air consumption at 6 bar Luftverbrauch bei/Air consumption at 8 bar

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Release 03 / 2012 • MAXIMATOR • Technical Data Sheet G10 • Page 3 of 3 • DB.01.01.11.01