4DO IOM Module: 4 X 16A Digital Relay Outputs For Local or Remote Serial Connection To A JACE Controller
4DO IOM Module: 4 X 16A Digital Relay Outputs For Local or Remote Serial Connection To A JACE Controller
4DO IOM Module: 4 X 16A Digital Relay Outputs For Local or Remote Serial Connection To A JACE Controller
Overview
The IOM range of I/O modules are
designed for use as local I/O within
motor control cabinets or as remote I/O
connected via RS485 Modbus. Typical
applications include building automation
control systems.
Page 1/2
TridiumEuropeIOM4DODS_v4
Specifications
Digital output data:
▪▪ number of outputs 4
▪▪ rated switching voltage 250v ac
▪▪ rated / inrush current (resistive load) 16A / 80A (20mS)
▪▪ maximum power rating 4,000VA
▪▪ maximum total module current 32A
▪▪ electrical life expectancy at rated / 4A load 1 x 105 cycles / 7 x 105 cycles @ 23°C & resistive load
▪▪ mechanical life expectancy 30 x 106 cycles
▪▪ maximum switching frequency 6 min-1 at rated current; 1,200 min-1 at no load
▪▪ contact material AgSnO2
▪▪ isolation test voltage (coil to contact) 4 kV
Bus data:
▪▪ bus protocol Modbus RTU
▪▪ bus interface RS485, half duplex, non isolated
▪▪ bus topology multidrop
▪▪ bus length maximum 500m
▪▪ bus speed 19,200 bps
▪▪ bus line termination integrated termination resistor (220Ω); activate via jumper (default: off)
▪▪ bus protection built-in transient protection
▪▪ bus connector pluggable male & female integrated connectors (modules mounted with zero spacing)
▪▪ bus cabling Shielded Twisted Pair (STP)
General data:
▪▪ module power supply 20v to 28v ac or dc
▪▪ module current 250ma ac or 100ma dc
▪▪ operating temperature range 0°C to +50°C
▪▪ storage temperature range -20°C to +70°C
▪▪ CE marking Low voltage directive (LVD) 2006/95/EC according requirements of EN 50178
EMC directive 2004/108/EC according requirements of EN 55011 and EN 61326-1
▪▪ conductor cross section 0.2mm2 to 2.5mm2 screw clamp connection
▪▪ insulation stripping length 6mm
▪▪ mounting DIN-rail TS35 (35mm x 7.5mm) or direct mounting by M3 fixing
▪▪ installation position any
▪▪ assembly up to 15 in a row with zero spacing
▪▪ module size (l x w x h-TS35 / direct) 53mm x 95mm x 60mm / 58mm
▪▪ insulating material / flammability class Housing: Noryl. Terminals: Polyamid 6.6 V0 / UL94-V0
▪▪ protection degree (DIN 40050) IP 20
▪▪ installation guide for mounting and I/O wiring details please refer to the IOM Installation guide
▪▪ communications guide for Modbus communications details please refer to the IOM Module Communications guide
How to Order
Product
Code Description
Copyright © 2013 Tridium. All rights reserved ®. Tridium, Niagara, NiagaraFramework, JACE and Security are trademarks or registered trademarks of Tridium.
Other marks are the properties of their respective owners. All specifications subject to change without notice or liability to provide changes to prior purchasers. Information
and specifications published here are current as of the date of publication of this document. Tridium reserves the right to change or modify specifications without prior notice.