Wi040 Ing
Wi040 Ing
WI040
LARZEP, S.A. LARZEP AUSTRALIA PTY. LTD. LARZEP AUSTRALIA PTY. LTD.
Avenida Urtiaga, 6 139 Wedgewood Road, 49A Sustainable Avenue
48269 MALLABIA, SPAIN HALLAM, VIC. 3803 AUSTRALIA BIBRA LAKE, WA 6163 AUSTRALIA
Tel. +34 943 171200 Tel. +61 (3) 9796 3744 Tel. +61 (8) 9418 4988
Fax. +34 943 174166 Fax. +61 (3) 9796 5964 Fax. +61 (8) 9418 2644
e-mail: [email protected] e-mail: [email protected] e-mail: [email protected]
www.larzep.com www.larzep.com.au www.larzep.com.au
Instruction Manual
Modular Hand Pump “WI040”
INDEX
1. BEFORE USING THE EQUIPMENT AND SECURITY -------------------------- 2
2. WARRANTY --------------------------------------------------------------------------------- 2
3. TECHNICAL FEATURES ---------------------------------------------------------------- 2
4. START UP------------------------------------------------------------------------------------- 3
5. MAINTENANCE ---------------------------------------------------------------------------- 3
6. DECLARATION OF CONFORMITY ------------------------------------------------- 4
ANNEX
GENERAL DRAWING
The correct union of a pump to a cylinder via a hydraulic hose constitutes a machine designed for lifting, pulling, folding and retaining operations, etc., that,
due to its high thrust capacity requires safe use in order to eliminate the risk of accidents.
Read the instructions manual carefully and practise using the equipment before application.
Choose the most suitable model for the application from the wide range available, and make sure that it will not exceed 80% of its nominal capacity during
normal operation.
Define stable zones for applying the load and safety zones for operators, separating them through the use of hoses of sufficient length.
Block loads mechanically once the movement has been completed and avoids operating underneath them.
Use the entire cylinder’s useful support surface, both on the head and the base. Be prepared to use tilting heads if applying lateral loads.
Remove loads before carrying out maintenance operations and always work in clean, well-lit areas.
Include control elements (pressure gauges) in the installation in order to enable the operator to monitor the pressure in the system and ensure that the
equipment’s nominal capacity is never exceeded. Be prepared to use safety valves and accessories if the safety criteria so demand.
The pump controls should be activated manually, as should the connections between elements equipped with quick plugs.
Once you have finished using the device, check that it has not been damaged, clean it and protect it ready for storage.
Clean the quick plugs before connecting and make sure the connections are perfect (first insert as far as the plug will go and then screw in by hand). A bad
connection may result in improper functioning and may even generate a safety hazard.
Install the device in such a way as to ensure that the hoses are not subjected to sharp or forced bends or thrust actions that may cause them to break.
Do not modify the device (welded parts, lengthening drive levers, etc.) without consulting the manufacturer.
Do not use the hoses for transporting the device. Use the handles on the cylinders (when appropriate) and set the pump lever to the transportation position.
When filling the pump with oil, always use LARZEP hydraulic oil or another oil of similar characteristics. Fill only to the indicated level and remember that
the cylinder piston should be back.
Before initiating operation, check that the installation is correct, the operator position is safe and the working zone is out of bounds to all personnel.
In all cases, the operator should have received adequate training regarding the handling of the device and logical safety criteria associated with the movement
of heavy loads.
2. WARRANTY
LARZEP, S.A. guarantees its products against all design and manufacturing defects for the durations of two years from the date of purchase. This guarantee does not
include the ordinary wear of both metal and non-metal parts, abuse, using the equipment beyond its rated capacity and any wear or damage incurred as a result of
using a hydraulic fluid which is not recommended by LARZEP, S.A.
Please note that if the equipment is disassembled or serviced by anyone other than an authorized service dealer or by LARZEP, S.A., this guarantee is rendered null
and void.
In the event of a warranty claim, return the equipment, to LARZEP, S.A. or the authorized dealer which sold you the hydraulic equipment, LARZEP, S.A. will
repair or replace the faulty equipment, whichever is deemed most appropriate. LARZEP, S.A. shall not be held liable for any consequential damages or losses,
which may occur as a result of faulty equipment.
3. TECHNICAL FEATURES
MODEL WI 040
WORKING PRESSURE 700 kg/cm²
PISTON DIAMETER 38 mm
OIL FLOW PER STROKE 36.2 cm³
2
Instruction Manual
Modular Hand Pump “WI040”
4. START UP
This is a modular pump, it is supplied with a lever to pump the oil and its use is very simple.
These pumps are lightweight, easy to fix by the base so, we can use them with different sizes of tanks.
To start operating with the pump, we only have to place the lever in the upper of the pump and pump several times until reach the wished stroke of the hydraulic
element in the system.
5. MAINTENANCE.
Checking the oil level.
With the pump in vertical position (base downwards), unscrew or pry off the plug. Check the level on the dip stick.
This check must be carried out with the cylinder fully retracted. Excessive amount of oil in the tank will lead to internal pressures which will hamper the
function of the pump.
Filter the oil before filling up the pump.
Once the equipment is being used the areas exposed to wear and oxidation must be cleaned and greased.
BREAK DOWNS AND REPARATIONS
THE CYLINDER DOESN´T REACH WORKING PRESSURE. THE CYLINDER DOESN´T AVANCE
Relief valve decalibrated (12) ____ Calibrate the valve. Lack of oil in the tank ____ Check the oil.
Retention ball valve failure (20) ____ Clean the seat and replace the ball. Couplers not fully inserted ____ Check couplers.
Closing ball valve failure (22) ____ Clean the seat and replace the ball. Admission ball valve failure (19) ____ Clean the seat and
Pressure seal damaged (26) ____ Replace the seal. replace the ball.
Cylinder pressure seal damaged (see cylinder) ____ Replace the seal. Closing ball valve failure (22) ____ Clean the seat and
THE CYLINDER DOES NOT RETRACT replace the ball.
Too much oil in the tank ____ Check the level.
3
Instruction Manual
Modular Hand Pump “WI040”
6. DECLARATION OF CONFORMITY
4
Instruction Manual
Modular Hand Pump “WI040”