0% found this document useful (0 votes)
60 views3 pages

Slab Thickness Calculation

The document contains calculations of slab thickness for typical floors, roof slabs, and a water tank level slab of a building. It includes tables showing imposed load, span, effective depth, and calculated and finalized slab thickness for 25 panels in each slab type. The calculations consider support conditions and interpolate between shorter and longer span depths to determine the effective depth and slab thickness.

Uploaded by

Almaden Site
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views3 pages

Slab Thickness Calculation

The document contains calculations of slab thickness for typical floors, roof slabs, and a water tank level slab of a building. It includes tables showing imposed load, span, effective depth, and calculated and finalized slab thickness for 25 panels in each slab type. The calculations consider support conditions and interpolate between shorter and longer span depths to determine the effective depth and slab thickness.

Uploaded by

Almaden Site
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Table 1.

1 - Slab Thickness Calculation for Typical Floors

Imposed load Span / Effective depth considering Slab


Longer span / Interpolated Span / Shorter span Effective depth Finalized slab
Panel (including support conditions thickness
Shorter span Effective depth (mm) (mm) thickness (mm)
finishes) If one way If two way (mm)

P1 4.25 kN/m2 29 35 1.2 34 4648 137 167 175


2
P2 4.25 kN/m 29 - 2.5 29 2133 74 104 150
P3 2.75 kN/m2 29 - 2.5 29 2286 79 109 150
2
P4 2.75 kN/m 29 - 2.5 29 2438 84 114 150
P5 4.25 kN/m2 29 35 1.2 34 3810 112 142 150
2
P6 4.25 kN/m 29 35 1.9 29 3810 131 161 150
P7 4.25 kN/m2 29 35 1.2 34 3810 112 142 150
P8 4.25 kN/m2 31 40 1.9 29 3810 131 161 150
P9 4.25 kN/m2 29 - 5.15 29 1600 55 85 150
P10 4.25 kN/m2 29 35 1.6 31 3840 124 154 150
P11 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P12 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P13 4.25 kN/m2 31 40 1.4 36 3810 106 136 150
P14 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P15 4.25 kN/m2 31 40 1.4 36 3810 106 136 150
P16 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P17 4.25 kN/m2 31 40 1.6 37 3810 103 133 150
P18 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P19 4.25 kN/m2 31 40 1.6 37 3810 103 133 150
P20 4.25 kN/m2 31 40 1.9 32 3810 119 149 150
P21 4.25 kN/m2 29 - 2.2 29 3200 110 140 150
P22 4.25 kN/m2 31 40 1.9 32 3536 111 141 150
P23 4.25 kN/m2 29 - 4.1 29 914 32 62 150
P24 4.25 kN/m2 29 35 1.9 29 3536 122 152 150
P25 4.25 kN/m2 29 35 1.1 34 2667 78 108 150
Table 1.2 - Slab Thickness Calculation for Roof Slab

Imposed load Span / Effective depth considering Slab


Longer span / Interpolated Span / Shorter span Effective depth Finalized slab
Panel (including support conditions thickness
Shorter span Effective depth (mm) (mm) thickness (mm)
finishes) If one way If two way (mm)
2
P1 5.75 kN/m 29 35 1.2 34 4648 137 167 175
P2 5.75 kN/m2 31 40 1.4 36 4267 119 149 150
2
P3 5.75 kN/m 29 35 2.0 29 1524 53 83 150
P4 5.75 kN/m2 29 35 1.4 31 3048 98 128 150
P5 5.75 kN/m2 29 35 1.2 34 3810 112 142 150
P6 5.75 kN/m2 29 35 1.9 29 3810 131 161 150
P7 5.75 kN/m2 29 35 1.2 34 3810 112 142 150
P8 5.75 kN/m2 31 40 1.9 29 3810 131 161 150
P9 5.75 kN/m2 31 40 1.4 36 3810 106 136 150
P10 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P11 5.75 kN/m2 31 40 1.4 36 3810 106 136 150
P12 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P13 5.75 kN/m2 31 40 1.4 36 3810 106 136 150
P14 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P15 5.75 kN/m2 31 40 1.4 36 3810 106 136 150
P16 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P17 5.75 kN/m2 31 40 1.6 37 3810 103 133 150
P18 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P19 5.75 kN/m2 31 40 1.6 37 3810 103 133 150
P20 5.75 kN/m2 31 40 1.9 32 3810 119 149 150
P21 5.75 kN/m2 29 - 2.2 29 3200 110 140 150
P22 5.75 kN/m2 31 40 1.9 32 3536 111 141 150
P23 5.75 kN/m2 29 35 3 29 1829 63 93 150
P24 5.75 kN/m2 29 35 1.9 29 3536 122 152 150
P25 5.75 kN/m2 29 35 1.1 34 2667 78 108 150
Table 1.3 - Slab Thickness Calculation for Water Tank Level Slab

Imposed load Span / Effective depth considering Slab


Longer span / Interpolated Span / Shorter span Effective depth Finalized slab
Panel (including support conditions thickness
Shorter span Effective depth (mm) (mm) thickness (mm)
finishes) If one way If two way (mm)

P1 2 kN/m2 29 35 1.4 32 4267 133 163 150


2
P2 2 kN/m 29 35 1.9 29 3048 105 135 150
P3 2 kN/m2 29 35 4.0 29 1753 60 90 150
2
P4 2 kN/m 29 35 1.2 33 5486 166 196 200
2
P5 2 kN/m 29 35 1.1 34 2667 78 108 150
2
P6 2 kN/m 11 - - 11 1000 91 121 125
2
P7 2 kN/m 11 - - 11 1000 91 121 125