Please note:
Dimensions provided in this Guide are for REFERENCE ONLY
and should not be used for site preparation or construction.
GSL Artira
Table of Contents
UP
occupy valuable floor space and, when folded, is
the most compact inclined lift available. It is also
capable of turning tighter corners than any other
lift on the market.
• Safety - The Artira is available with a large
selection of safety and useability options. It is
considered to be one of the most user-friendly
inclined platform lift available today.
1-800-663-6556 or 1+604-594-0422
UP
Unusual Bends:
For applications such as theaters, restaurants or
lecture halls.
UP
UP
Unusual Landings:
An ideal layout for stages or store entrances.
Radiating Stairs:
Found in installations such as hotel lobbies or
observatories.
Spiral Stairs:
Turning Stairway In A Multi-Level Building Grand staircases in hotels or theaters.
Applications Include:
- Schools - Churches
- Courthouses - Commercial Buildings
- Theaters - Historical Buildings
- Restaurants - Residential
- Hospitals - And Many More
Outdoor Applications
When located outdoors, the lift must be equipped with
stainless steel outdoor compatible components. See
page 21 for more information on the outdoor weather-
resistant package. For outdoor units, stainless steel
components are available in a painted finish.
How it Works
Two custom-designed steel guide tubes which platform through a slot in the upper tube. The drive
are custom designed for each stairway support the system, consisting of an electric motor and drive cog,
platform. These tubes contain a continuous loop moves the wire haul rope and the wheelchair platform
of wire haul rope that is attached to the upper up and down the stairway.
carriage. This carriage is mounted to the back of the
Drive System
Steel Guide Tubes (Drive Box Shown) Drive Cog
Wire Haul Rope
Platform Hanger
Upper Carriage
Platform
Overspeed Safety
The Overspeed Safety is located at the lower end of Mechanical Pawl
the tube system and consists of a mechanical pawl and
electrical cut-out switch. In the unlikely event that the
lift should descend too quickly, both the mechanical Electrical
and electrical safety will activate simultaneously and Cut-out Switch
stop the platform from moving.
Overspeed Safety
Component Identification
The main components of an inclined lift are:
Platform, Drive, Guide Tubes, Call Stations
Call Station
Standard Drive
System
Platform
Overspeed Safety
Optional Compact
Drive System
*ADA Compliant
Under Platform
Anti-Slip Deck Surface Sensing Plate
Ramps with
Bi-Directional Pedestrian Safety Lights
Obstruction Sensing (Pedestrian Audio Alert
upgrade optional)
Platform Components
Directional Buttons
The durable and vandal resistant platform control The platform can be equipped with an optional
panel is mounted to the platform hanger. The standard Attendant Remote Control that overrides the con-
platform controls are permanently mounted and stant pressure Directional Buttons during attendant
consist of two large illuminated constant pressure operation. The remote control unit can be removed
Directional Buttons for independent operation and an when not required.
Emergency Stop Button (with illumination optional).
Standard Platform
Safety Features
Safety Sensing Pedestrian Safety Lights
The platform is equipped with safety sensors listed be- This illuminated tube lighting located at the base of
low. These sensors will automatically stop the lift when the ramps visually alerts pedestrians of the platform’s
activated by 1.8 kg (4 lbs.) of pressure. The platform location during travel, while still being discreet to the
can then be backed away from the obstruction. passenger.
Grab Bar
The Grab Bar is a 25mm (1”) diameter aluminum bar
located on the front face of the platform control panel
to assist passengers in loading and unloading.
Folding Seat
Designed for use by ambulatory passengers, this
folding seat is equipped with a safety belt. For
commercial applications, the folding seat and seat belt
are required by the ASME A18.1 safety code in the USA.
Side Load
For confined lower landing spaces, an automatically
deployed side load ramp allows the passenger to wheel
onto the platform diagonally, offering easier access.
Auto Fold
This feature automatically folds the platform if it is left
unfolded at a landing for a period of time.
Call Stations
Located at each landing, the call station enables the Keyless (optional)
user to unfold the platform with a touch of a button. A keyless call station is available as an option.The key-
If the platform is not at the landing, the user simply less lift does not have a keyswitch on the call station.
presses the illuminated directional button to call the
platform to their landing. Remote Platform Fold/Call (optional)
This feature allows the platform to be folded up and
Garaventa Smart-Lite Technology™ called from any call station should the platform be left
The Artira’s Smart-Lite Technology™ illuminates the folded down.
correct call station button, guiding the user through
the sequenced steps to call and unfold the lift from the Mounting Options
call station (patent pending). The call stations can be mounted on the wall (surface
or flush mounted) or on a pedestal (when no suitable
surface is available). The upper call station can also
Call Station Options be mounted on the drive box or on the tube system
• Emergency Stop Button (with illumination itself (only available with Drive Box arrangement).
optional) Flush mount call stations can be pre-wired during the
• Attendant Call Switch construction or building renovations, resulting in a
cleaner appearance with no surface wiring.
Platform and
Ramp Power Fold
Up Button
Location for
Optional Emergency
Stop Button
”]
[2
mm
51
190 mm [7 1/2”]
102 mm x 102
mm [4” x 4”]
electrical box
190 mm [7 1/2”]
1
[5 50
15 7/ mm
0m 8”
m ] 8”]
[5
7/8 3/
” [2
] m
m
60
Flush Mount Call Station (optional) Surface Mount Call Station
pages 15 + 16
C
See Turning
Clearances
See Turning
Clearances pages
15 + 16
Notes:
- *ADA Compliant
- Dimension A + B has been calculated using a drop-down
landing configuration and a first riser height of 178mm
(7”).
- Dimensions are based on standard platforms with stan-
dard ramps. Ramp extensions will increase the clearances
required.
- Contact your local Garaventa representative or call the
Garaventa Design Hot Line for more information.
(Inside Bend)
(Note: Nearest obstruction.ie,
handrail or wall)
F
A
Wall to outside
of tubes
E
(Straight Lift Applications)
No Bends
B
Platform
Folded Up
D
Platform
Folded Down
Side Load Ramp Loading
(optional)
Platform Sizes
Attachment 800 x 1220 mm* 800 x 1050 mm 800 x 900 mm 700 x 750 mm
Dim.
Method (31 1/2" x 48")* (31 1/2" x 41 3/8") (31 1/2 x 35 3/8") (27 1/2" x 29 1/2")
mm in mm in mm in mm in
Direct Mount 125 4 7/8 125 4 7/8 125 4 7/8 125 4 7/8
A
Tower Mount 150 5 7/8 150 5 7/8 150 5 7/8 150 5 7/8
Direct Mount 320 12 5/8 320 12 5/8 320 12 5/8 330 13
B
Tower Mount 345 13 5/8 345 13 5/8 345 13 5/8 355 14
Direct Mount 1015 40 1015 40 1015 40 900 35 3/8
C
Tower Mount 1040 41 1040 41 1040 41 925 36 3/8
Direct Mount 1230 48 3/8 1230 48 3/8 1230 48 3/8 1115 44
D
Tower Mount 1255 49 3/8 1255 49 3/8 1255 49 3/8 1140 45
Direct Mount 1035 40 3/4 1035 40 3/4 1035 40 3/4 920 36 1/4
E
Tower Mount 1060 41 3/4 1060 41 3/4 1060 41 3/4 945 37 1/4
Direct Mount 1225 48 1/4 1185 46 5/8 1145 45 1/8 1025 40 3/8
F
Tower Mount 1250 49 1/4 1210 47 5/8 1170 46 1/8 1050 41 3/8
Notes:
• *ADA Compliant
• Dimensions E and F include 20mm (3/4”) running • For towers mounted to 2” x 6” wood boards on walls
clearance and include standard ramps. Ramp extensions (see page 26) add 38mm (1 1/2”) to the above tower
will increase the clearances required. Contact your local mount dimensions.
Garaventa Lift representative or call the Garaventa
Design Hot Line for more information.
Offset Drive
When upper landing space is limited, the drive box
can be positioned closer to the stairs and to the wall.
860 (33 7/8”) min.
(5 1/2” min.
140 mm
Notes:
For 90° and 180° configurations, add 200mm (7 7/8”)
if the Call Station is mounted on the tubes.
50 (2”) min.
Drive on Shelf
The drive box can be attached to a shelf that is fastened
to a solid wall.
Drive System
The drive is always located at the upper end of the Mains Power Requirements
guide tubes. It is available in two arrangements, the Both drive systems require 208-240 VAC single-
standard Drive Box and the Compact Drive. Each phase 50/60 Hz. on a dedicated 20 amp. circuit.
drive system is suited to a particular application,
with a variety of design configurations to choose from
(see pages 17-19 for drive configurations).
Drive Cog
”] ”]
5/8 /8
[10 [2 3
270 60
213 [8 3/8”]
1053 [41 1/2”]
Lower Tube
945 [37 1/4”]
Centerline ]
6”
6 [1
40
508 [20”]
Controller Box
521 for Compact
[20
1/2 Drive
”]
Drive Box
23
3[
91
/ 8”
]
Audio Visual Alert Box Size: 597 mm (23 1/2”) high x 444 mm
A wall mounted strobe light and audible chime cautions (17 1/2”) wide x 192 mm (7 5/8”) deep
pedestrians in the vicinity that the lift is in operation.
The volume of the audible chime can be adjusted on Outdoor and Extreme Applications
site. This option is ideal for stairways with 90 degree When located outdoors or in extremely harsh
or 180 degree switchbacks. environmental conditions, the lift will require a
stainless steel drive box, stainless steel tubes, towers
Fire Alarm Integration (Fire Service) and audio visual alerts (if specified).
The fire service feature is designed to interface with
a building’s fire safety system and interrupt power A vinyl platform cover is recommended for outdoor
to the lift when the fire alarm sounds. This ensures applications.
the lift will not obstruct stairway traffic during
evacuation. If the lift is in use when the alarm The Compact Drive System is not available for
sounds, the lift will only allow the platform to travel to outdoor applications or with stainless steel tubes.
the designated landing with the emergency exit. The
passenger must use the constant pressure direction Note: In certain indoor applications such as
button. Custom versions of this feature are available. near a swimming pool, an outdoor weather-
Consult Garaventa Lift. resistant package may be required.
Guide Tubes
The platform travels on two steel tubes, 51mm
(2”)in diameter, that are affixed 600mm (23 5/8”)
apart vertically. The location of the tubes on the
stairs depends on the platform size and the angle
of the stairs. Generally speaking, the lower tube is
approximately 500mm (21 5/8”) vertically above the
stairs when a 800 x 1220 mm (31 1/2” x 48”)platform
is used.
Upper Tube
Triangle of Sup-
port
Lower Tube
Horizontal Stabilizer
(back of platform shown)
Upper Tube
Stabilizer
The stabilizer tube is placed in horizontal or shallow
sections of the lift’s travel. This slotted tube allows a Handrail
roller, mounted to the back of the platform, to enter and
travel through. This roller connection creates a triangle
of support to stabilize the platform. The stabilizer is
required whenever the lift travels horizontally or at an
angle of less than 20°.
Lower Tube
A
100 (3 7/8”) min.
50 (2”) min.
B
In-line Drive with Platform Storage 90° Drive with Platform Storage
(Drive Box Shown, also available with Compact Drive) (Compact Drive Shown, also available with Drive Box)
Notes:
Dimensions for Compact Drives are approximate only. Factors affecting the location of the Compact Drive include stair angle,
motor orientation and ramp extensions. Contact your local Garaventa Lift representative or call the Garaventa Lift Design Hot
Line for more information.
- If the call station is mounted on the tubes, add 200mm (7 7/8”) for drive box configurations.
- Dimensions are based on standard platforms with standard ramps. Ramp extensions will increase the clearance
dimensions required.
n
mi
”]
[1
25
Ceiling or other obstruction
Dimension A
Note:
This running clearance is for the
platform in the folded position only.
See dimensions below for overhead
requirements for passenger usage and
codes.
Stair Angle
Platform
required to any point above the platform
deck. Refer to Dimension B in chart on
US Code Dimension B - Canadian Code Dimension C
Total Overhead Clearance Required
page 25.
Minimum US Code Requirements
End of Plat-
form
Canadian Code (CSA B355)
1500mm (59”) overhead clearance
required to the centerline of the
platform. Refer to Dimension C in chart
on page 25.
Stair Angle
Platform Size
Stair 800 x 1220 mm 800 x 1050 mm 800 x 900 mm 700 x 750 mm
Angle (31 1/2" x 48") (31 1/2" x 41 3/8") (31 1/2 x 35 3/8") (27 1/2" x 29 1/2")
Dimension A
mm in mm in mm in mm in
22° 1560 61 3/8 1500 59 1445 56 7/8 1330 52 3/8
25° 1690 66 1/2 1610 63 3/8 1540 60 5/8 1400 55 1/8
30° 1825 71 7/8 1730 68 1/8 1645 64 3/4 1475 58 1/8
35° 2000 78 3/4 1880 74 1775 69 7/8 1560 61 3/8
40° 2215 87 1/4 2070 81 1/2 1945 76 5/8 1685 66 3/8
45° 2460 96 7/8 2290 90 1/8 2140 84 1/4 1845 72 5/8
Platform Size
Stair 800 x 1220 mm 800 x 1050 mm 800 x 900 mm 700 x 750 mm
Angle (31 1/2" x 48") (31 1/2" x 41 3/8") (31 1/2 x 35 3/8") (27 1/2" x 29 1/2")
Dimension B
mm in mm in mm in mm in
22° 2086 82 1/8 2020 79 1/2 1960 77 1/8 1880 74
25° 2170 85 3/8 2090 82 1/2 2020 79 1/2 1930 76
30° 2320 91 3/8 2220 87 1/2 2135 84 2020 79 1/2
35° 2480 97 5/8 2365 93 1/8 2260 89 2120 83 1/2
40° 2665 104 7/8 2525 99 3/8 2400 94 1/2 2235 88
45° 2880 113 3/8 2710 106 3/4 2560 100 3/4 2365 93
Platform Size
Stair 800 x 1220 mm 800 x 1050 mm 800 x 900 mm 700 x 750 mm
Angle (31 1/2" x 48") (31 1/2" x 41 3/8") (31 1/2" x 35 3/8") (27 1/2" x 29 1/2")
Dimension C
mm in mm in mm in mm in
22° 1820 71 5/8 1785 70 1/4 1755 69 1/8 1705 67 1/8
25° 1865 73 3/8 1825 72 1790 70 1/2 1730 68
30° 1945 76 5/8 1895 74 5/8 1850 72 7/8 1780 70
35° 2030 79 7/8 1970 77 1/2 1920 75 5/8 1835 72 1/4
40° 2130 83 7/8 2060 81 1/8 1995 78 1/2 1895 74 5/8
45° 2245 88 3/8 2160 85 2085 82 1/8 1965 77 3/8
Upper Tube
The following are examples of common tube attachment
methods. To ensure that the structure can withstand Gusset
the loads and forces exerted by the lift, please consult
Distance Plate
a structural engineer. Back Plate
Lower Tube
Please refer to the loading diagram on Direct Mount Strut Tower Mount Strut
page 29 for wall and floor reactions.
Solid Walls
- solid concrete, concrete block, wood or steel
reinforcement.
This construction is ideal for direct mounting as the
struts can be attached directly to the wall. Where Weak Wall Structure
extra support is necessary the upper hole in the (RequiresThrough Bolt)
strut can be fastened through the wall.
Direct Mount
Tower
Tower Base
Upper Tube
Handrail Tube
Tower
Platform Size
Stair 800 x 1220 mm 800 x 1050 mm 800 x 900 mm 700 x 750 mm
Angle (31 1/2" x 48") (31 1/2" x 41 3/8") (31 1/2 x 35 3/8") (27 1/2" x 29 1/2")
mm in mm in mm in mm in
20° 1155 45 1/2 1125 44 1/4 1095 43 1/8 1055 41 1/2
25° 1230 48 3/8 1190 46 7/8 1155 45 1/2 1100 43 1/4
30° 1315 51 3/4 1270 50 1225 48 1/4 1155 45 1/2
35° 1410 55 1/2 1355 53 3/8 1300 51 1/8 1215 47 7/8
40° 1520 59 7/8 1450 57 1/8 1385 54 1/2 1285 50 5/8
45° 1645 64 3/4 1560 61 3/8 1485 58 1/2 1365 53 3/4
i n.
]m
8”
/
37
0[
10
Stair Angle
Loading Diagram
F
Loads are based on an 800 x 1220mm
(31 1/2” x 48”) platform: X d2
Straight Lifts And/Or Lifts With Inside
Radius Bends d1
F1= 1093 N (246 lbf)
F2= 2942 N (661 lbf)
d1= 296mm (11 5/8”)
d2= 506mm (19 7/8”)
Tower Mount
X is 92mm (3 5/8”) min. to 330mm (13”) max.
Direct Mount
X is 100mm (4.0”) min. to 140mm (5 1/2”) max.
F1 F2
Maximum Moment C.G. of Rated
M= 3144 Nm (27827 in.lbf) with Tower Mount Conveyance Load
M= 2377 Nm (21041 in.lbf) with Direct Mount
Tower Mount
X is 92mm (3 5/8”) min. to 330mm (13”) max.
Direct Mount
X is 100mm (4.0”) min. to 140mm (5 1/2”) max.
Maximum Moment
M= 3580 Nm (31682 in.lbf) with Tower Mount
M= 2787 Nm (24664 in.lbf) with Direct Mount
Technical Reference of
Standard Features
Platform Sizes Drive System
800 x 1220mm (31 1/2” x 48”) - ADA Compliant Motor: Single phase (supplied by inverter) 2 H.P. drive
800 x 1050mm (31 1/2” x 41 3/8”) box at the end of the guide tube system. The drive
800 x 900mm (31 1/2” x 35 3/8”) box can be located away from the upper landing by
700 x 750mm (27 1/2” x 29 1/2”) extending the guide tubes.
Power Requirements: The mains power requirement for
Curved Safety Arms both drive systems is 208-240 VAC, 50/60 HZ single
phase on a dedicated 20 amp. circuit.
Fully automatic, 32mm (1 1/4”) diameter safety arms,
top of arm 948mm (37 3/8”) above platform deck. Power Transmission: Roped sprocket using 8mm (3/8”)
wire haul rope.
Emergency Use: Ratchet wrench (or handwheel) is
Pedestrian Safety Lights provided.
Illuminated tube lighting, located at both ends of the
platform deck. Alerts pedestrians that the platform is
in motion. Overspeed Safety
Located at the bottom of the tube assembly containing
mechanical overspeed sensor and brake, with electrical
drive cut-out protection.
Rated Load
300 kg. (660 lbs.)
Rail System
Two 51mm (2”) O.D. steel tubes spaced 600mm (23
Speed 5/8”) apart vertically.
6 meters (20 ft) per minute, slowing to 3 meters (10
ft) through corners and when approaching or departing
landings.
Finishes
Durable electrostatically applied and baked fine tex-
tured Satin Grey paint.
Operating Controls
Call Stations (Standard): Equipped with Garaventa Lift
Smart-Lite Technology™, constant pressure directional
buttons, one touch fold & unfold buttons, 24VDC power,
and keyed operation.
Platform (Standard): Equipped with constant pressure
switches, Emergency Stop Button (manual reset) and
keyless operation
Audio Visual
(Optional Item)
Audio Visual
3 Conductors Integrated
min. 20 AWG Disconnect
Switch
Intermediate
Call Station
Call Station
3 Conductors min.
20 AWG
Overspeed Safety
1 Conductor
min. 20 AWG Lower Call
Station
Call Station
3 Conductors min. 20 AWG
Printed in Canada
15810-M-DP
© G a ra v e n t a L i f t . A s w e a r e
continuously improving our products,
specifications outlined in this brochure