Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
192 views
8 pages
RESUN SOLAR Installation Manual
RESUM
Uploaded by
Juan José Bonilla Reinoso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download
Save
Save RESUN SOLAR Installation Manual For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
0 ratings
0% found this document useful (0 votes)
192 views
8 pages
RESUN SOLAR Installation Manual
RESUM
Uploaded by
Juan José Bonilla Reinoso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Carousel Previous
Carousel Next
Download
Save
Save RESUN SOLAR Installation Manual For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
Download
Save RESUN SOLAR Installation Manual For Later
You are on page 1
/ 8
Search
Fullscreen
ESU INSTALLATION MANUAL FOR STANARD MODULE 1.0 GENERAL INFORMATION 1.4 INSTALLATION MANUAL DISCLAIMER. 1.2 LIMITATION OF LIABILITY 2.0 SAFETY PRECAUTIONS 3.0 MECHANICAL / ELECTRICAL SPECIFICATIONS 4.0 UNPACKING AND STORAGE, 5.0 MODULE INSTALLATION 5.1 MODULE WIRING 5.2 EQUIPMENT GROUNDING 6.0 MOUNTING INSTRUCTIONS 6.1 MOUNTING METHOD: BOLTING 7.0 MAINTENANCE GENERAL INFORMATION www.resunsolar.com 1ESU This general manual provides important safely information relating tothe installation, maintenance and handling of RS-series solar modules. Professional installer must read these guidelines carefully and stctly follow these instructions. Failure to follow these instructions may result death, injury or property damage. The installation and handling of PV modules requires professional skils and should only be performed by qualified professionals. The installers must inform end -users (consumers) the aforesaid information accordingly, ‘The word "module" or "PV module” used inthis manual refers to one or more RS-series solar modules. Pease retain this manual for future reference. We recommend checking www.resunsolar.com regularly for the most updated 14 INSTALLATION MANUAL DISCLAIMER The information contained in this manual is subject to change by Resun Solar Energy Co, Ltd without prior notice, Resun Solar Energy Co,Ltd gives no warranty of any kind whatsoever, ether expltly or impliity, with respect tothe information contained herein. 12 LIMITATION OF LIABILITY Resun Solar Energy Co,Ltd shall not be held responsible for damages of any kind, including — without imitation — body harm, injury or damage to property, in connection with handling PY modules, sytem installation, or compliance or non-compliance withthe instructions set forth jn this manual 2.0 ‘SAFETY PRECAUTIONS Waring Before attempting to install, wire, operate andlor service the module and other electrical equipment, al instructions should be read and understood PV module inter connectors pass direct current (0C] when exposed to sunlight or other light sources Contact wth electrically active parts of the module, such as terminals, can resul in injury or death, respective of whether or not the module and the other electrical equipment have been connected GENERAL SAFETY {Al installation work must comply wth applicable regional and local regulations or other national or international electrical standards, Protective clathing (non-slip gloves, lathes, etc.) must be worn during installation to prevent direct contact with 30 V DC or ‘greater, and to protect your hands against sharp edges. Prior to installation, remove all metalic jewelry to prevent accidental exposure to lve circuits \When installing or handling modules in light rin, morning dew or strong wind, appropriate safety measures should be taken to avoid damaging the modules or injuring people. Do not allow children or unauthorized persons near the inst Use electrically insulated tools to raduce the risk of electric shock. Ifthe disconnects and OCPD's cannot be opened or the inverter can not be powered down, cover the fronts of modules in the PV array with an opaque material to stop the production of electricity when installing or working on a module or wiring. Do not use or install broken modules. lation site or storage area of modules. Contact with module surfaces or frames may cause electric shock ifthe front glass is broken or the back sheet is tor, ‘The PV module does not contain any serviceable parts. Do not attempt to repair any part of the module. Keep the junction box cover closed at all times. Do not disassemble a module or remove any module part Do not artificially concentrate sunlight on a module. Do not connect or disconnect modules when current from the modules or an external source is present. www.resunsolar.com 2ESU 3.0 MECHANICAL / ELECTRICAL SPECIFICATIONS. ‘Module electrical ratings are measured under Standard Test Conditions (STC) of 1000 Wimeirradiance, with an [AMIS spectrum, and a cell temperature of 25°C. Detailed electrical and mechanical characteristics of Resun Solar Energy Co,Ltd rystaline silicon PV modules specifications can be found on www.resunsolar.com ‘Main electrical characteristics under STC are also stated on each module label. The maximum system voltage {or all module series is stated on data sheet Under certain conditions, a module may produce more current or voltage than under its Standard Test CConedition’s rated power. As a result, the module short-circuit current at under STC shoul be multiplied by 1.25, {and a correction factor should be applied to the open-circuit voltage when determining component ratings and capacities. Depending on your local regulations, an additional 1.25 multiplier for the short-circuit current (giving 2 total multiplier of 1.56) may be applicable when sizing conductors and fuses. 40 UNPACKING AND STORAGE. PRECAUTIONS AND GENERAL SAFETY I modules are stored in an uncontrolled environment for less than 3 months, extra precautions should be taken to prevent moisture exposure to connectors or sunlight exposure to modules, Unpack module pallets carefully, following the steps shown on the pallet. Unpack, transport and store the. modules with care. Modules must always be unpacked by two people. Always use both hands when handling modules Do not stand, step, walk andlor jump on modules Stacks of modules should contain no more than 12 modules, and the frames should be aligned, Do not place excessive loads on the module or twist the module frame. Do not use sharp instruments on the modules, Particular care should be taken to avoid module back sheets www.resunsolar.com abeing damaged by sharp objects, as scratches may directly affect product safety. Do not leave modules unsupported or unsecured. Do not change the wiring of bypass diodes. Koop all electrical contacts clean and dry. PRODUCT IDENTIFICATION Each module is equipped with two identical bar codes (one inside the laminate under the front glass, the second on the rear side ofthe module) that act 9s a unique identifier. Each module has a unique serial number containing 13 (pre March 2013) or 14 (past March 2013) digits. ‘A nameplate is also affixed tothe rear of each module. This nameplate specifies the model type, as well as the main electrical and safety characteristics of the module. 5.0 MODULE INSTALLATION PRECAUTIONS MEASURES AND GENERAL SAFETY Prior to instaling modules please obtain information about any requirements and necessary approvals for the site, installation and inspection from the relevant authorities ‘Check applicable building codes to ensure that the construction or structure (roo, facade, support, ele.) can bear the module system load S-series solar modules have been qualified for Application Class A (equivalent to Safety Class I requirements). Modules rated under this class should be used in systams operating at voltage above 50 V or ower above 240 W, where general contact access is anticipated. When installing modules, please ensure the supporting roof has a fire resistant roof covering rated forthe application “The fre rating for this module is only valid when the produc s installed as specified in the mechanical ‘mounting instructions. DO NOT STAND OR STEP on the modules under any circumstances. Localized heavy loads may cause severe micro-cracks at cell level, which in turn may compromise module reliability. ENVIRONMENTAL CONDITIONS “The module is intended for use in general open-air climates, environmental conditions appearing in nature ‘Temperature and humidity Please consult the Resun Solar Co.,Ltd . technical support department for more information on the use of ‘modules in special climates. Do not install modules near naked flames or flammable materials Do not immerse modules in water or constantly expase modules to water (ether fresh or sall (1. rom fountains, sea spray). Exposing modules to sal (.e. marine environments) or sulfur (Le. sulfur sources, volcanoes) incurs the risk of ‘module corrosion INSTALLATION REQUIREMENTS: Ensure that the module meets the general technical system requirement. Ensure that other system components do not damage the module mechanically or electrically, www.resunsolar.com 4‘Modules can be wired in series to increase voltage or in parallel to increase current, To connect modules in series, connect the cables from the positive terminal of one module to the negative terminal of the next ‘module. To connect in parallel, connect the cables from the positive terminal of one module tothe positive terminal on the next module. ‘The quantity of bypass diodes in the module's junction box may vary depending on the model series. Only connect the quantity of modules that corresponds to the voltage specifications ofthe inverters used in the system, Modules must not be connected together to create a voltage higher than the maximum permitted system voltage, even under the worst local temperature conditions (see Table 1 forthe correction coefficients that apply o open-circuit voltage) ‘A maximum of two strings can be connected in parallel without the need to incorporate an over-current protection device (fuses, etc) in series within each sting. Three or more strings can be connected in parallel if ‘an appropriate, certified over-current protection devi |s installed in series within each sting Only modules with similar electrical outputs should be connected in the same string to avoid oF minimize mismatch effects in arays. ‘To minimize risk i the event of an indirect lightning strike, avoid forming loops when designing the system, The recommended maximum series fuse rating is stated in a table inthe Annex, Modules should be safely fixed to bear all expected loads, including wind and snow loads. A minimum Clearance of 6.5 mm (0.25 in) between modules is required to allow for thermal expansion ofthe frame. The small drainage holes on the underside of the module must nat be blocked. ‘OPTIMUM ORIENTATION AND TILT ‘Tomaximize your annual yield, ind out the optimum orientation and tt for PV modules in your region. The highest yields are achieved when sunlight shines perpendicularly onto the PV modules. AVOID SHADING Even minor partial shading (e.g from dit deposits) reduces yields. A module can be considered to be Lunshaded i its entire surface is free from shading all year round, Sunlight should be able to reach the module ‘even on the shortest day ofthe year RELIABLE VENTILATION Sufficient clearance (at least 10 cm (3.94 in)) between the module frame and the mounting surface is required {0 allow cooling air to circulate around the back ofthe module. This also enables condensation or moisture to dissipate. 5A MODULE WIRING CORRECT WIRING SCHEME Ensure thatthe wiring is correct before starting up the system. Ifthe measured open circuit voltage (Voc) and short-crcutt current (Isc) difer substantially from the specications, this indicates that there isa wiring faut CORRECT CONNECTION OF PLUG CONNECTORS: Make sure that connections are safe and tight. Plug connector should not be subjected to stress from the exterior. Connectors should only be used to connect the circuit. They should never be used to turn the circuit on www.resunsolar.com 5ESU ‘and oft USE OF SUITABLE MATERIALS. Only use dedicated solar cable and suitable plugs (wiring should be sheathed in a sunight-esistant Conduit or, i exposed, should be sunight-resistant ise) that meet local fre, bulding and electrical regulations. Please ensure that all wing isin perfect electrical and mechanical condition. Installers may only use single conductor, 25-10 mma(8-14 AWG), 90°C wet rated solar cable, with proper Insulation that is able to withstand the maximum possible system open-circuit voltage . Only copper conductor ‘material should be used. Selecta suitable conductor gauge to minimize voltage drop. CABLE PROTECTION Secure the cables to the mounting system using UV-resistant cable ties. Protect exposed cables from damage by taking appropriate precautions (e.. placing them inside a plastic condul). Avoid exposure to direct sunlight. ‘A minimum bending radius of 60 mm (2.36 in) is required when securing the junction box cables tothe racking system 6.0 GROUNDING we recommend that they be grounded and that module installation should comply wth all local electrical codes and regulations. Grounding connections should be installed by a qualified electrician. Connect module frames together using adequate grounding cables: Resun Solar recommends using ‘4-14mm? copper wire. Holes provided for this purpose are identified with a green label. ll conductive Connection junctions must be firmly fied. All bolts, nuts, flat washers, lock washers and other relevant hardware should be made of stainless steel, Unless otherwise specified Resun Solar Energy Co. Ld does not provide ground hardware, % © Grounding holes ® Junction box © Standard mounting holes (long side) @ Additional mounting holes (high wind or snow loads) © Standard mounting holes (short side) © Module frame © Cables and connectors ho, ‘The mounting design must be certified by a registered professional engineer. The mounting design and procedures must comply with local codes and requirements from all relevant authorities, Resun Solar does not provide mounting hardware, www.resunsolar.com 8ESU ‘Standard modules can be mounted onto a support structure using one of several approved methods. ‘One such method is described below. Use appropriate corrosion-proof fastening materials. All mounting hardware (bolts, spring washers, flat washers, nuts) should be stainless steel Use a torque wrench for installation. Do not dill adtional holes or modify the module frame, Doing 50 will void the warranty ‘Standard modules can be installed in either landscape or portrait orientations. Refer to the detailed Instructions for futher guidance, Please note that in areas with heavy snowfall (> 2400 Pa) further countermeasures such as the use of addtional support bars should be considered to avoid snow loads damaging the lowest row of modules. 61 MOUNTING METHOD: BOLTING ‘Modules should be bolted to support structures through the maunting holes inthe rear frame flanges only + Each module must be securely fastened ata minimum of 4 points on two opposite sides, using the innermost ‘mounting holes. Mé size bolt and nut shal be used for bolting method. Tightening torques should be within 4~6 Nm (2.0-44 ft-bs) for M6xt coarse thread bolts, depending on bolt class. In areas with heavy wind loads, addtional ‘mounting pints should be used. The sytem designer and the insaler are responsible for calculating the loads and ensuring thatthe support structure meets the requirements ‘Mounting method: Botting a Modules should be bolted atthe following hole locations depending on the configuration and load: Table 2: Approved bolting methods www.resunsolar.com 7ESU luptite toad < 2400 pa luptite load < 2400 pa lbownforce load < 2400 Pa 400 Pa < Downforce load < 5400 Pa i i pach il a a UJ 4 Ln aiearanaaig ag SS ee a coinnnmions 7.0 MAINTENANCE Do not make modifications to the PV components (diode, junction box, plug connectors). Regular maintenance is required to keep modules clear of snow, bird droppings, seeds, pollen, leaves, branches, dirt spots, and dust Modules with sufficient ft (at least 15°), generally do ‘ot require cleaning (ran will have a self-cleaning effect). f the module has become soiled, it shall be washed with water and a non-abrasive cleaning implement (sponge) during the cool part of the day. Do not scrape oF rub dry dirt away, as this may cause micro scratches. ‘Snow should be removed using a soft brush. ‘The system shall be periodically inspected to very the integrity of all wiring and supports To protect against electric shock or injury, electrical or mechanical inspections and maintenance should be performed by qualified personnel only and on a regular basis. www.resunsolar.com 8
You might also like
Renewsys Solar Installation Manual
PDF
No ratings yet
Renewsys Solar Installation Manual
24 pages
Installation Manual - AE SOLAR
PDF
No ratings yet
Installation Manual - AE SOLAR
12 pages
Rayzon Installation Manual - TOPCON G2G - 15032024 - Updated
PDF
No ratings yet
Rayzon Installation Manual - TOPCON G2G - 15032024 - Updated
31 pages
Manual CHSM6612P
PDF
No ratings yet
Manual CHSM6612P
17 pages
JINKO - Manual IEC2016-2022.06.23 - (EN-4+6)
PDF
No ratings yet
JINKO - Manual IEC2016-2022.06.23 - (EN-4+6)
70 pages
Almaden Safety & Installation Instruction Manual (2020)
PDF
No ratings yet
Almaden Safety & Installation Instruction Manual (2020)
34 pages
Installation Manual Jinko IEC Rev 2023.02.03
PDF
No ratings yet
Installation Manual Jinko IEC Rev 2023.02.03
22 pages
CEC-Installation-Manual-4.16 - Leapton
PDF
No ratings yet
CEC-Installation-Manual-4.16 - Leapton
12 pages
TUVDV Manual
PDF
No ratings yet
TUVDV Manual
30 pages
JA Module Installation Manual
PDF
No ratings yet
JA Module Installation Manual
14 pages
Installation Guide For Bluesun Solar Standard PV Module
PDF
No ratings yet
Installation Guide For Bluesun Solar Standard PV Module
14 pages
UL61730InstallationManual20231101 162006
PDF
No ratings yet
UL61730InstallationManual20231101 162006
37 pages
Installation Manual - AE SOLAR 2
PDF
No ratings yet
Installation Manual - AE SOLAR 2
57 pages
TUV DV Manual 2021-11-12) Instalacion Bifacial JINKO
PDF
No ratings yet
TUV DV Manual 2021-11-12) Instalacion Bifacial JINKO
34 pages
TUV Manual IEC2016-2021.05
PDF
No ratings yet
TUV Manual IEC2016-2021.05
68 pages
TUV Manual IEC 2016 (2020.12)
PDF
No ratings yet
TUV Manual IEC 2016 (2020.12)
53 pages
Manual de Instalação Paineis Solares Canadian
PDF
No ratings yet
Manual de Instalação Paineis Solares Canadian
45 pages
TUV Manual IEC2016 2022.04.11 PDF
PDF
No ratings yet
TUV Manual IEC2016 2022.04.11 PDF
69 pages
Installation Manual of Dymond Module en
PDF
No ratings yet
Installation Manual of Dymond Module en
19 pages
InstallationManualJinko (IEC) Updatedversion2024.06.11 143403
PDF
No ratings yet
InstallationManualJinko (IEC) Updatedversion2024.06.11 143403
23 pages
CEC JA Solar PV Single-Glass Modules Inatallation Manual A21
PDF
No ratings yet
CEC JA Solar PV Single-Glass Modules Inatallation Manual A21
20 pages
Double Glass Solar Modules Installation Manual
PDF
No ratings yet
Double Glass Solar Modules Installation Manual
17 pages
Installation Manual For DAH Solar Full-Screen Modules-Version 2.0
PDF
No ratings yet
Installation Manual For DAH Solar Full-Screen Modules-Version 2.0
22 pages
Manual - Leapton Mono 665 - LP210-M-66-MH
PDF
No ratings yet
Manual - Leapton Mono 665 - LP210-M-66-MH
13 pages
Installation Manual of Standard Solar Modules: For Professional Use Only
PDF
No ratings yet
Installation Manual of Standard Solar Modules: For Professional Use Only
37 pages
PV Module Installation Manual Rev.1 - 2023
PDF
No ratings yet
PV Module Installation Manual Rev.1 - 2023
20 pages
Installation&c2&a0Manual&c2&a0Jinko&c2&a0 (IEC) &c2&a0 20230720
PDF
No ratings yet
Installation&c2&a0Manual&c2&a0Jinko&c2&a0 (IEC) &c2&a0 20230720
23 pages
JA Bifacial Mono Module Standard Installation Manual A11 - 20220104
PDF
No ratings yet
JA Bifacial Mono Module Standard Installation Manual A11 - 20220104
14 pages
TUV Manual IEC2016
PDF
No ratings yet
TUV Manual IEC2016
45 pages
Eging Installation Manual
PDF
No ratings yet
Eging Installation Manual
18 pages
Tiger Installation Manual
PDF
No ratings yet
Tiger Installation Manual
19 pages
A Crystalline Silicon Double Glass Frame PV Module Installation Guide&ef&bc&88166 Half&ef&bc&89 V6201109
PDF
No ratings yet
A Crystalline Silicon Double Glass Frame PV Module Installation Guide&ef&bc&88166 Half&ef&bc&89 V6201109
16 pages
TUV Manual German Codes 2022 01 21 Jan PDF
PDF
No ratings yet
TUV Manual German Codes 2022 01 21 Jan PDF
32 pages
InstallationManualJinko (IEC) Updatedversion2023.12.10 161748
PDF
No ratings yet
InstallationManualJinko (IEC) Updatedversion2023.12.10 161748
22 pages
RNG Installation Manual UL
PDF
No ratings yet
RNG Installation Manual UL
11 pages
TUV DV Manual 2021-11-12) Instalacion Bifacial JINKO-3-4
PDF
No ratings yet
TUV DV Manual 2021-11-12) Instalacion Bifacial JINKO-3-4
2 pages
Installation Manual Jinko (IEC) Updated Version-2023 12 10
PDF
No ratings yet
Installation Manual Jinko (IEC) Updated Version-2023 12 10
23 pages
Installation Manual: Monocrystalline Modules and Polycrystalline Modules
PDF
No ratings yet
Installation Manual: Monocrystalline Modules and Polycrystalline Modules
18 pages
LG - VDE - NeON R - Installation Manual
PDF
No ratings yet
LG - VDE - NeON R - Installation Manual
12 pages
Installation Manual - Jinko N
PDF
No ratings yet
Installation Manual - Jinko N
33 pages
CH VH DSS SL 01 - B1 - Installation Manual Solar PV Module
PDF
No ratings yet
CH VH DSS SL 01 - B1 - Installation Manual Solar PV Module
12 pages
FEMA 451B Topic 13 Notes Wood Structures
PDF
No ratings yet
FEMA 451B Topic 13 Notes Wood Structures
62 pages
Solar Power System Installation Manual
PDF
No ratings yet
Solar Power System Installation Manual
42 pages
Manual EN
PDF
No ratings yet
Manual EN
11 pages
Installation Manual of Standard Solar Modules IEC en
PDF
No ratings yet
Installation Manual of Standard Solar Modules IEC en
12 pages
Anaerobic Processes For The Treatment of Municipal and Industrial Wastewater and Waste
PDF
100% (1)
Anaerobic Processes For The Treatment of Municipal and Industrial Wastewater and Waste
49 pages
D 053 Suntech IEC INST Enu
PDF
No ratings yet
D 053 Suntech IEC INST Enu
9 pages
HIT Power SA06 Series Installation Manual
PDF
No ratings yet
HIT Power SA06 Series Installation Manual
11 pages
Manual: Reinvents The PV Module
PDF
No ratings yet
Manual: Reinvents The PV Module
5 pages
Installation Manual - BlueSolar Panels - en NL FR de ES SE Rev - 01
PDF
No ratings yet
Installation Manual - BlueSolar Panels - en NL FR de ES SE Rev - 01
80 pages
Installation Manual of Standard Solar Modules En-V2.1
PDF
No ratings yet
Installation Manual of Standard Solar Modules En-V2.1
46 pages
Information About PV
PDF
No ratings yet
Information About PV
44 pages
User Manual Honeywell Solar Modules 2015 1473940020
PDF
No ratings yet
User Manual Honeywell Solar Modules 2015 1473940020
12 pages
Photovoltaic Module Safety & Installation Manual: Notice!
PDF
No ratings yet
Photovoltaic Module Safety & Installation Manual: Notice!
12 pages
Installation - Safety Instructions - Maintenance: Photovoltaic Modules User Manual ET Solar Series Module
PDF
No ratings yet
Installation - Safety Instructions - Maintenance: Photovoltaic Modules User Manual ET Solar Series Module
5 pages
Installation Instructions Photovoltaic Module: En-1 En-4
PDF
No ratings yet
Installation Instructions Photovoltaic Module: En-1 En-4
4 pages
Photovoltaic Modules User Manual ET Solar Series Module: Installation - Safety Instructions - Maintenance
PDF
No ratings yet
Photovoltaic Modules User Manual ET Solar Series Module: Installation - Safety Instructions - Maintenance
10 pages
IEC Installation Manual
PDF
No ratings yet
IEC Installation Manual
8 pages
Factory Address: No.900 South, Road No.8, PO Box No.1, Sri City SEZ, Sathyavedu Mandal, Chittor DT, A.P. - 517588 India
PDF
No ratings yet
Factory Address: No.900 South, Road No.8, PO Box No.1, Sri City SEZ, Sathyavedu Mandal, Chittor DT, A.P. - 517588 India
11 pages
Do 66 Pen Type Dissolved Oxygen Tester Meter For Aquarium Fish Tank Aquaculture
PDF
No ratings yet
Do 66 Pen Type Dissolved Oxygen Tester Meter For Aquarium Fish Tank Aquaculture
3 pages
EXOS2 GOTO 4951750GB0314 Manual
PDF
No ratings yet
EXOS2 GOTO 4951750GB0314 Manual
28 pages
Sistemas Biofloc Un Avance Tecnologico e
PDF
No ratings yet
Sistemas Biofloc Un Avance Tecnologico e
5 pages
Ohaus ST20D Pen Manual
PDF
No ratings yet
Ohaus ST20D Pen Manual
2 pages