Application: Centrifugal Single Stage Pumps QVD
Application: Centrifugal Single Stage Pumps QVD
Application
Pumps of QVD Series are intended for pumping clean and slightly Those pumps may be applied to irrigation schemes of large areas
polluted and even turbid water containing not more than 1 − 3 g of with pumping raw water out of surface resources, inlet sewerage
sand or others impurities per 1 dm3 water, with max. grain size 0.5 systems, and so on. Besides that, they are applicable in industrial
mm. A pumped stuff may be of slightly corrosive character. and municipal pumping stations supplying service water, as well
Values pH of a pumped liquid may range from 6 to 8.5. Maximal as in various water management systems for water re−pumping,
permissible temperature of a pumped water is 60 °C. circulating and cooling, and so on.
321.2
d3 d4
861
321.1
350.1
700.1
102.1
d2
890
102.1 Pump casing, lower part 452.1 Ring 542 Throttle bush d2 Central drain for service was−
102.2 Pump casing, upper part 452.2 Flange 681 Coupling guard te of a pumped liquid
210 Shaft 458 Ring 700.1 Waste piping d3 Supply of clean sealing water
234 Impeller 461 Gland packing 700.2 Vent piping into the front seal (only with
321.1 Bearing 502 Casing wear ring 703 Seal flooding pumping a polluted water)
321.2 Bearing 503 Impeller wear ring 861 Half−coupling „BKN“ d4 Supply of clean sealing water
350.1 Bearing cover 524.1 Seal bush − left 890 Washer into the rear seal (only with
350.2 Bearing housing 524.2 Seal bush − right pumping a polluted water)
d5 Central connection for venting
(evacuation)
Centrifugal single−stage pumps QVD
Description Drive
Pumps of QVD Series are of volute−casing centrifugal single−stage Pumps of QVD Series are constructed for direct coupling with
horizontally−split type, with double−entry impeller and rotor shaft a driving electric motor. Transmission of the driving motor torque
supported on rolling−contact bearings. onto the pump is through a pin flexible coupling that allows dis−
Pump casing being split in its longitudinal axis plane shall be pro− mantling without need of piping and/or the driving motor de−
vided with a double volute to make radial pressure reduction possi− coupling.
ble. At the casing bottom half in its centre there are both pump As a standard the pump is supplied being placed on a separate
branches (the suction and discharge ones) arranged horizontally, plate. Driving motor is available on separate foundation blocks for
which allows piping installation above a foundation. setting in concrete.
Impeller is of symmetrical execution with axial double−sided ent−
ry of water and it is sealed against the pump casing with replace− Arrangement of branches
able wear rings. Suction branch is situated on the right side (position S−90), dis−
Bearings. Rotor is carried on either side in rolling−contact bear− charge branch on the pump left side (position T−270), as viewed
ings. On request those pumps may be provided with thermal re− from a driving motor.
ceptors for possibility of remote measurements of bearing tempe−
ratures. Material options
Seals. Pump shaft is sealed on either side by shaft seals with soft The material option „LU“ may be considered as the standard one,
cord−type packing. With pumping clean water there seals are pro− with the pump main parts of following construction materials:
vided with continuous hydraulic closure of a pumped liquid being − volute casing with throttle bushes and bearing housings are of
supplied from the discharge space to prevent atmospheric air grey cast iron
pumping−in, provided the pump works with suction (from vacuum). − impeller with wear rings and shaft sleeves are of chrome steel
However, with pumping polluted water, there is supply of clean − shaft is of heat−treated carbon steel
pressure water into seals from an external supply with overpres− Further material options on the customer request.
sure 0.5 bar against pressure at the pump suction branch − see
connections d3; d 4 necessary for both seal hydraulic closure and Sense of rotation
wear protection due to leakage.
Pumps rotate clockwise, as viewed the pump from the drive side,
On request those pumps may be provided with a mechanical seal.
on principle.
Venting. To allow venting with possible connection to automatic
evacuation system the pump is provided with evacuation piping
with a cut−off cock and the main connection.
150
100 500−QVD−890
150−QVD−570 n=960
80 250−QVD−570 300−QVD−600
400−QVD−620 500−QVD−820
n=960
60 125−QVD−480 600−QVD−960
300−QVD−470 500−QVD−750
200−QVD−460 n=720
250−QVD−500 n=960
50 500−QVD−660
100−QVD−400 n=960
400−QVD−440 600−QVD−920
40 500−QVD−590 n=720
150−QVD−370 200−QVD−400
80−QVD−370 n=960
300−QVD−415
30
125−QVD−320 500−QVD−530 600−QVD−720
150−QVD−350 n=960 500−QVD−530 n=740
250−QVD−350 n=960
400−QVD−375
20 100−QVD−280
125−QVD−300
200−QVD−300
80−QVD−250
100−QVD−250
150−QVD−280
10
5
10 20 30 40 50 60 80 100 200 300 400 500 600 800 1000 2000 3000
Q [l.s −1]
Centrifugal single−stage pumps QVD
Dimensions of pumps
l
b a c
d5 e f
d3 d4 d5
k
g
h1
d
D
h
D1
d2
h
d2
s
l
R J R1
p r
C G F G
B C
A E
Shaft Bed
Pump Pump Branches Foundation
end plate
model
a b c e f g h h1 l d k p r s D D1 A B C E F G H I I1 R R1 J
80−QVD−250 260 325 560 300 260 140 420 590 585 30 65 530 630 150 150 80 940 300 320 910 570 170 300 20 30 150 285 4x70x70
80−QVD−370 345 430 640 320 320 190 540 790 775 45 85 530 630 150 125 80 940 300 320 910 570 170 300 20 30 150 285 4x70x70
100−QVD−250 300 363 660 330 330 135 430 605 663 34 63 530 630 150 200 100 940 300 320 910 570 170 300 20 30 150 285 4x70x70
100−QVD−280 295 360 660 360 300 160 450 640 655 34 65 530 630 150 200 100 940 300 320 910 570 170 300 20 30 150 285 4x70x70
100−QVD−400 375 460 760 380 380 205 570 840 835 50 85 530 630 150 150 100 940 300 320 910 570 170 300 20 30 150 285 4x70x70
125−QVD−300 360 445 760 380 380 160 490 700 805 40 85 530 630 150 250 125 940 300 320 910 570 170 300 20 30 150 285 4x70x70
125−QVD−320 345 410 780 420 360 180 490 710 755 38 65 530 760 150 200 125 940 300 320 1060 700 180 300 20 30 150 350 4x70x70
125−QVD−480 450 535 860 430 430 250 655 980 985 55 85 530 630 150 200 125 940 300 320 910 570 170 300 20 30 150 285 4x70x70
150−QVD−280 430 515 860 430 430 215 580 840 945 45 85 660 930 150 250 150 1080 400 340 1250 870 190 300 20 30 200 435 4x70x70
150−QVD−350 420 505 900 450 450 190 545 790 925 48 85 530 760 150 300 150 940 300 320 1060 700 180 300 20 30 150 350 4x70x70
150−QVD−370 390 475 920 500 420 210 540 800 865 45 85 530 760 150 250 150 940 300 320 1060 700 180 300 20 30 150 350 4x70x70
150−QVD−570 530 635 1000 500 500 295 750 1130 1165 65 105 660 760 150 200 150 1080 400 340 1060 700 180 300 20 30 200 350 4x70x70
200−QVD−300 460 545 1000 500 500 230 605 880 1005 50 85 660 930 150 300 200 1080 400 340 1250 870 190 300 20 30 200 435 4x70x70
200−QVD−400 480 565 1000 500 500 215 600 880 1045 55 85 660 930 150 350 200 1080 400 340 1250 870 190 300 20 30 200 435 4x70x70
200−QVD−460 495 580 1050 550 500 260 640 960 1075 55 85 660 930 150 300 200 1080 400 340 1250 870 190 300 20 30 200 435 4x70x70
200−QVD−670 625 730 1200 600 600 345 855 1300 1355 75 105 830 760 150 250 200 1240 500 370 1060 700 180 300 20 30 250 350 4x70x70
250−QVD−350 535 622 1140 570 570 270 680 1000 1157 56 87 830 930 150 350 250 1240 500 370 1250 870 190 300 20 30 250 435 4x70x70
250−QVD−500 598 733 1100 550 550 270 710 1058 1331 65 130 830 930 150 350 250 1240 500 370 1250 870 190 300 20 30 250 435 4x70x70
250−QVD−570 598 733 1300 700 600 325 750 1150 1331 65 130 830 1130 150 350 250 1240 500 370 1500 1070 215 400 20 30 250 535 4x70x70
Dimensions of the foundation for the whole pump−set (pump + electric motor) are affectable with dimensions of a driving motor being selected individually. That
is why the pump−set dimensional sketch may be worked up on request, after technical clearing−up factual business, both of tenders or orders. Thickness of
foundation shall be specified by an engineer of a projection company.
Suction branch „D“ ................. for PN 10, with raised face
Discharge branch D1 ............... for PN 10, PN 16 or PN 25, always with raised face − according to individual types given in a Table of Performance Data
d2 .............................................. central drain for waste water from seals. Connection consists of union nut G 1 1/4“
d3, d4 ........................................ Clean water supply from an external supply for hydraulic closure of seals (only in case of pumping polluted water). Separate
connection consists of union nut G 1/2“
d5 .............................................. Venting (evacuation) of pump. Main connection consists of union nut G 3/4“.
Centrifugal single−stage pumps QVD
Dimensions of pumps
l
a b
c
d5
e f
d4 d3
k
g
h1
d
D1
D
h
d2
t
d2
s
H
J
C E C
A B
F
Shaft Bed
Pump Pump Branches Foundation
end plate
model
a b c e f g h h1 l d k s t D D1 A B C E F H J
300−QVD−415 623 755 1400 700 700 320 850 1240 1378 65 130 180 40 400 300 300 640 250 1080 1580 400 4x70x70
300−QVD−470 605 740 1620 870 750 400 950 1445 1355 75 135 160 40 400 300 300 740 180 1380 1700 400 4x70x70
300−QVD−600 672 850 1400 700 700 320 800 1220 1522 78 160 140 30 400 300 250 660 260 1080 1600 400 4x70x70
300−QVD−660 670 880 1400 700 700 350 870 1600 1550 80 170 160 40 400 300 300 700 180 1050 1410 400 4x70x70
400−QVD−375 800 980 1600 800 800 370 950 1320 1780 85 170 180 40 500 400 300 720 180 1340 1700 400 4x70x70
400−QVD−440 685 880 1600 800 800 350 900 1305 1565 75 160 160 30 500 400 300 700 180 1340 1700 400 4x70x70
400−QVD−620 880 1075 1600 800 800 430 1000 1455 1955 90 170 160 40 500 400 300 820 180 1340 1700 400 4x70x70
400−QVD−660 750 1000 1600 800 800 400 1000 1450 1750 90 170 160 40 500 400 300 760 180 1340 1700 400 4x70x70
500−QVD−530 870 1050 2000 1000 1000 450 1120 1630 1920 98 170 180 40 600 500 300 940 210 1580 2000 400 4x70x70
500−QVD−530 1100 1320 2000 1000 1000 450 1250 1900 2420 115 210 200 40 600 500 300 1000 230 1780 2240 400 4x70x70
500−QVD−590 940 1120 2060 1030 1030 470 1150 1710 2060 98 170 180 40 600 500 300 980 210 1580 2000 400 4x70x70
500−QVD−660 800 1000 2000 1000 1000 450 1120 1820 1800 100 170 180 40 600 500 300 900 210 1580 2000 400 4x70x70
500−QVD−750 900 1100 2400 1300 1100 600 1360 2090 2000 110 210 200 40 600 500 300 1100 250 1950 2450 500 6x100x100
500−QVD−820 995 1215 2650 1450 1200 660 1475 2280 2210 125 210 200 40 700 500 300 1300 250 2100 2600 500 6x100x100
500−QVD−890 1010 1190 2100 1050 1050 480 1165 1795 2200 98 170 180 40 600 500 300 1000 210 1580 2000 400 4x70x70
600−QVD−720 1485 1765 3000 1500 1500 550 1635 2510 3250 150 270 240 40 800 600 300 1340 260 2330 2850 500 6x100x100
600−QVD−920 1070 1325 2600 1300 1300 600 1460 2230 2395 140 270 240 40 800 600 250 1040 265 2170 2700 500 6x100x100
600−QVD−960 1230 1510 3250 1750 1500 820 1815 2810 2740 150 270 240 40 800 600 300 1620 280 2580 3140 500 6x100x100
Dimensions of the foundation for the whole pump−set (pump + electric motor) are affectable with dimensions of a driving motor being selected individually. That
is why the pump−set dimensional sketch may be worked up on request, after technical clearing−up factual business, both of tenders or orders. Thickness of
foundation shall be specified by an engineer of a projection company.
Suction branch „D“ ................. for PN 10, with raised face
Discharge branch D1 ............... for PN 10, PN 16 or PN 25, always with raised face − according to individual types given in a Table of Performance Data
d2 .............................................. central drain for waste water from seals. Connection consists of union nut G 1 1/4“
d3, d4 ........................................ Clean water supply from an external supply for hydraulic closure of seals (only in case of pumping polluted water). Separate
connection consists of union nut G 1/2“
d5 .............................................. Venting (evacuation) of pump. Main connection consists of union nut G 3/4“.
Centrifugal single−stage pumps QVD
Moment of inertia has been specified for a pump with a complete flexible coupling „BKN“. Weight has been specified for a pump being provided with its own bed
plate.