0% found this document useful (0 votes)
233 views1 page

Combined Footing Design

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1/ 1

COMBINED FOOTING DESIGN FOOTING NAME: CF1

Load Data : DL+%LL EQ or Wind


P kN 7549.00 9219.00 Fy = 500 N / mm2
FX kN 39.00 263.00 Fck = 25 N / mm2
Fy kN 10.00 77.00
MX kN m 8.00 154.00 S.B.C = 180 kN / m2
My kN m 40.00 845.00

Area required : = 8303.9 = 46.133 m2


180
Provide Footing Size = 5.7 x 8.8
Area Provided = 50.16 m2 OK
Depth of Footing :
Provided Depth D = 1.05 m Provide Initial D = 0.99 m
Effective Depth deff = 1 m
Additional Moments: Mx1 = 39 kN-m
My1 = 10 kN-m
Final Loads : P = 7549 Kn
Mx = 47 kN-m
My = 50 kN-m
Net upward pressure Pmax = 152 kN / m2 OK For Design P = 155 kN / m2
Pmin = 149 kN / m2 OK
Check For EQ or Wind Loads:
Pmax = 199 kN / m2 OK For Check P = 225 kN / m2
Pmin = 169 kN / m2 OK

Design for Flexure: Shorter - Direction:


Maximum cantilever projection = 1.8 m
2
M = 155.00 X 1.8
2
M = 251.100 kN-m
K = Mu/bd2 = 0.377
Pt = 0.088 Provide 0.12%
Ast = 1260 mm2
Provide 16 @ 155 C/C

Design for Flexure: Longer - Direction:


Maximum cantilever projection = 1.3 m
2
M = 155.00 X 1.3
2
M = 130.975 kN-m
K = Mu/bd2 = 0.196
Pt = 0.046 Provide 0.12%
Ast = 1260 mm2
Provide 16 @ 155 C/C

Check for One-Way Shear:


tv = 155.00 X ( 1.800 - 1 ) X 1.5
1000
tv = 0.186 N / mm2
tc = 0.272 N / mm2 > tv OK

Check for Punching Shear:


Size of the Column C = 300 X 1200

Max Unfactored Load P = 2500.00 kN


Allowable Shear Stress t allowable = 0.938 N / mm2
Actual Shear Stress t actual = 0.442 N / mm2 < t allowable OK