Automatic Blood Components Extractor: Our Technology Your Health

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Automatic blood components extractor

Our technology Your health

Our technology Your health


TOP sealing clamps

Flow regulator
and sealer

Active clamps panel


TOP optical sensor
(with lighting head
status)

REV.01 - 2016
Vertical scale with
adjustable height
REV.01

Lateral press
with scale Press 1 scale

Right hand
scale

Main press with BC


optical sensors group
Bottom sealing
clamp
Automatic blood components extractor

It works with any conventional or T&B bags


Two electronic presses fully controlled for speed, position and force
Automatic air removal procedures
Fine buffy-coat controls while using T&B bags
Flow regulator with high precision optical sensor
Five sealing clamps
16 pre-loaded Procedures
Up to five scales
RFID writer-reader and barcode
LED dashboard for tubes positioning
Wi-Fi, Ethernet or RS485 communication mode

You can download full specifications and the Technical Data Sheet
from our website www.delcon.it

GIOTTO is an automatic extractor designed to prepare blood components from centrifuged blood
in single use plastic bags manufactured upon the International Standard ISO 3826 and the European
Directives no. 93/42 and 2007/47 MDD. It can prepare high quality blood components with any kind of
commercially available bag, either conventional or TOP & BOTTOM type.

GIOTTO is available in two main versions, basic and with double press, each with different configuration
for computer connection.

• Electronic main press with integrated scale fully controlled for speed, generated force and position.
• Secondary press with integrated scale and same controls of main press (only with GIOTTO code GIO.
DB.00.P2X).
• Five programmable sealing clamps.
• External sealing handle available as option.
• Flow regulator with auto-zeroing optical sensor.
• Eight optical sensors on main press for fine control of BC volume and haematocrit.
• Three scales to read the net weights of all components (four with version GIO.DB.XXX.P2) plus one
external as option.
• Communication mode available as RS485, Wi-Fi or Ethernet (see versions of GIOTTO available).
• Barcode reader or COMBO RFID Tags reader-writer with integrated barcode (options).
• Graphic LCD Display white-blue back lighted with guided menu and membrane keyboard.
• 16 pre-loaded Programs as standard. Up to fifty additional PROGRAMS can be generated and stored
by using the dedicated SDM software.
• Automatic air removal and additive solution transfer available as standard routine.
• GIOTTO can read automatically all weights of components or, at the end of each extraction, can
weight up to five different bags as net or gross weight and thus record all data (after or before
tubing disconnection).
GIOTTO can deliver several information to SDM for each extraction procedure:
1. Serial number of GIOTTO 10. Net weight of PL extracted into other satellite bags
2. Description of the performed Program 11. Net weigh of Platelets Concentrate
3. Number of the performed Program 12. Net weight of packed RBC
4. Net weight of Plasma extracted 13. Separation date
5. Net weight of Buffy Coat 14. Time of separation
6. Net weight of whole blood 15. Duration of separation
7. Net weight of Plasma transferred into BC bag 16. Error codes if any
8. Net weight of transferred SAG-M 17. Tens of different and customizable codes, either
9. Net weight of PL transferred back into the main bag as barcode labels or RFID Tags are available too

COMMUNICATION AND TRACEABILITY MAIN PRESS


Communication mode via RS485, Wi-Fi or Ethernet. Electronically controlled. Wide controls
Codes handling can be done either as barcode labels on whole stroke. Possibility to generate
or RFID Tags. up to five independent speed-pressure
Cross-matching of each code by customized filters profiles with controls on pressures, speeds,
and/or fixed masks. position, feedback with optical sensors for
best handling of BC layer and phase time
Internal data base with automatic LOG saving for all
operations and extraction procedures. out for each Program.

FLEXIBILITY
16 pre-loaded extraction Programs with most
QUALITY AND SAFETY
common applications for double, triple, quadruple
All optical sensors perform automatically and quintuple conventional and Top & Bottom bags.
an auto-calibration to zero at any new Possibility to expand the list up to 50 Programs.
separation. Dynamic LEDs indicators for
Up to five integrated scales for automatic weighting
correct tubes positioning showing the
and recording of all blood preparations.
clamps to use, actives all separation long.
Five programmable welding clamps for manual or
Precise control of final buffy-coat volume
automatic operation: available as option a sixth
with fine adjustment of haematocrit while
portable tube sealer.
using top and bottom bags.
• = active sensor to hold on the BC level Air removal routine available as standard.
D* = distance to define precisely the desired Secondary press available to perform most complex
final volume procedures rapidly and precisely: filter priming, air
removal from plasma bag, fast SAG-M transferring
(only with versions GIO.DB.XXX.P2).

DATA MANAGEMENT AND COMPUTER


SDM-Software Data Management is a specific appli- • generate Reports based on the executed ex-
cation designed for remote controls of GIOTTO and traction procedures
for collection & handling of separation data. SDM • generate Reports based on the executed ex-
should be installed on a computer with Windows® traction procedures applying for customizable
XP, VISTA or 7 (computer and Microsoft® software filters to fit the minimal quality standards of the
not included). To communicate with the available blood bank. The Reports can be printed directly
GIOTTO, SDM may use RS485, Wi-Fi or Ethernet through the pre-defined printer of computer or
connections. By using SDM you can do the following saved as .csv or Word file (may requires Micro-
remote operations on all GIOTTO connected to the soft Office® on computer)
net: • by using the optional printer label (see options)
• modify any Program available on each GIOTTO it is possible to prepare customizable adhesive
• generate new Programs of separation labels to be populated with net or gross wei-
• download the data of each single extraction ghts, ID bags, ID Operator and some more
procedure performed by GIOTTO
ORDERING INFORMATION – Available versions of GIOTTO
GIOTTO - Automatic blood components GIOTTO - Automatic blood components
extractor: versions with MAIN press only. extractor: versions with TWO presses.
GIO.DB.485 GIO.DB.485.P2
Automatic blood components extractor, SINGLE Automatic blood components extractor, DOUBLE
press, three scales. Supplied complete of SDM press, four scales. Supplied complete of SDM
software, with standard RS485 communication. It software with standard RS485 communication. It
may request a network adapter (cod. ADAP-485- may request a network adapter (cod. ADAP-485-
USB) USB)
GIO.DB.LAN GIO.DB.LAN.P2
Automatic blood components extractor, SINGLE Automatic blood components extractor, DOUBLE
press, three scales. Supplied complete of SDM press, four scales. Supplied complete of SDM
software with RS485 and Ethernet module. It may software with RS485 and Ethernet module. It may
request an Ethernet switch (cod. GIO.DB.HUB_PC) request an Ethernet switch (cod. GIO.DB.HUB_PC)
GIO.DB.WIFI GIO.DB.WIFI.P2
Automatic blood components extractor, SINGLE Automatic blood components extractor, DOUBLE
press, three scales. Supplied complete of SDM press, four scales. Supplied complete of SDM
software with RS485 and Wi-Fi module. It may software with RS485 and Wi-Fi module. It may
request an WiFi access point (cod. GIO.DB.WIFI_AP) request an WiFi access point (cod. GIO.DB.WIFI_AP)

SEPARATE OPTIONAL ACCESSORIES


GIO.DB.40 CCD-BARCD1
External balance with tray. To be connected CCD barcode reader. It can be purchased and
directly to GIOTTO with a cable. It can be used added at any time (buy one for each GIOTTO).
to read the weight of any bag, before, during or OR
after the separation.
LSR-BARCD1
SEAL-HAND1 LASER barcode reader. It can be purchased and
Standard sealing handle equipped with 2 coaxial added at any time (buy one for each GIOTTO).
cables. It can be connected directly to the
auxiliary RF port of Giotto. It permits the manual GIO.DB.90
sealing of any standard PVC tubing of bags. It can Printer for adhesive labels. To be used to report
be purchased and added at any time on the bags some data such as the product type,
the net or gross weight, the ID of the bag.

ACCESSORIES FOR PC COMMUNICATION


GIO.DB.WIFI_AP CAB-485.5
WIFI access point  (buy one per Computer if Wifi RS485 network cable (5m) to connect devices
communication is in use). togheter (buy one per each GIOTTO if RS232-485
CAB-LAN.5 communication is in use).
LAN Ethernet cable (5m, buy one per each GIOTTO ADAP-485-USB
if Ethernet communication is in use). RS485 network adapter for USB computer
HUB-PC connection  (1 for each serial network - buy one
HUB Ethernet 16 entries (for LAN version, buy one per computer if USB-RS485 communication is in
per Computer if Ethernet connection is in use). use).
Our technology Your health

Our technology Your health

DELCON srl
20862 Arcore (MB) - Italy - Via Matteucci, 25/27
Phone +39 039.617670
Fax +39 039.617677
www.delcon.it
Our technology Your health

Delcon reserves the right to modify, add, and remove the functional and visual features
of the devices, at its sole discretion, at any time, and without prior notice

M A D E I N I T A L Y