OT Outside Tolerance (X Is Set)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

101609-3612 ZEXEL test values diesel fuel-injection equipment 06/10/21 13:02:41 Page 1

ZEXEL Ass'y No. 101609-3612


Bosch Ass'y No. 9 400 613 438
Bosch Typecode
Engine Type 6BTAA
Manufacturer KOMATSU
Edition date 14/01/05 (7)

1 Adjustment conditions
CAT Designation Unit Set value min. max. Actual values OT
Test oil ISO4113 or {SAEJ96
7d}
1404 Test oil
P Test oil temperature degC 40 40 45
Nozzle and nozzle holder 105780-8140
Bosch type code EF8511/9A
Nozzle 105780-0000
Bosch type code DN12SD12T
Nozzle holder 105780-2080
Bosch type code EF8511/9
P Opening pressure MPa 17.2
P Opening pressure kgf/cm2 175
Injection pipe mm 6-2-600
Outer diameter - inner diameter - length (mm)
Overflow valve 131424-3420
P Overflow valve opening pressure kPa 255 221 289
P Overflow valve opening pressure kgf/cm2 2.6 2.25 2.95
P Tester oil delivery pressure kPa 255 255 255
P Tester oil delivery pressure kgf/cm2 2.6 2.6 2.6
Direction of rotation (viewed from drive side) R
Right

2 Adjustment specification
2.1 Injection timing adjustment
CAT Designation Unit Set value min. max. Actual values OT
P Direction of rotation (viewed from drive side) R
Right
P Injection order 1-5-3-6-2-4
S Pre-stroke mm 2.7 2.65 2.75
S Rack position R=A
After adjusting injection quantity.
P Beginning of injection position NO.1
Drive side
S Difference between angles 1 deg. 60 59.5 60.5
Cal 1-5
S Difference between angles 2 deg. 120 119.5 120.5
Cal 1-3
S Difference between angles 3 deg. 180 179.5 180.5
Cal 1-6
S Difference between angles 4 deg. 240 239.5 240.5
Cyl.1-2
S Difference between angles 5 deg. 300 299.5 300.5
Cal 1-4
2.2 Injection quantity adjustment
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point A
P Rack position 9.1
P Pump speed r/min 1100 1100 1100
S Average injection quantity mm3/st. 100.5 99.5 101.5
S Max. variation between cylinders % 0 -2.5 2.5
P Basic *
P Fixing the lever *
P Boost pressure kPa 49.3 49.3
P Boost pressure mmHg 370 370
P Hydraulic cylinder ON *
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point -
P Rack position 6.3+-0.5
P Pump speed r/min 425 425 425
S Average injection quantity mm3/st. 9.5 8.5 10.5
S Max. variation between cylinders % 0 -15 15
P Fixing the rack *
P Boost pressure kPa 0 0 0
P Boost pressure mmHg 0 0 0
P Hydraulic cylinder ON *

OT = Outside Tolerance (X is set)


101609-3612 ZEXEL test values diesel fuel-injection equipment 06/10/21 13:02:41 Page 2

Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point D
P Rack position 9.3++
P Pump speed r/min 100 100 100
S Average injection quantity mm3/st. 85 80 90
P Fixing the lever *
P Boost pressure kPa 0 0 0
P Boost pressure mmHg 0 0 0
P Hydraulic cylinder OFF *
P Rack limit *
2.3 Governor adjustment
Name

K=10 N:Pump speed


P1=127+-10kPa(1.3+-0.1kgf/cm2) R:Rack position (mm)
BCL=1.5+-0.1mm (1)Target notch: K
N1=1100r/min (2)Tolerance for racks not indicated: +-0.05mm.
N2=400r/min (3)RACK LIMIT (When hydraulic cylinder is OFF)
(4)When hydraulic cylinder ON: P1
(5)Boost compensator stroke: BCL
(6)Rack difference between N = N1 and N = N2
2.4 Boost compensator adjustment
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 850 850 850
P Rack position R1-1.5
S Boost pressure kPa 5.3 4 6.6
S Boost pressure mmHg 40 30 50
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 850 850 850
P Rack position R1-1
S Boost pressure kPa 13.3 12 14.6
S Boost pressure mmHg 100 90 110
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 850 850 850
P Rack position R1(9.1)
S Boost pressure kPa 36 36 36
About
S Boost pressure mmHg 270 270 270
About

OT = Outside Tolerance (X is set)


101609-3612 ZEXEL test values diesel fuel-injection equipment 06/10/21 13:02:41 Page 3

2.5 Speed control lever angle


Name
a=8deg+-5deg
b=31deg+-5deg

F:Full speed
I:Idle
(1)Stopper bolt setting
2.6 Stop lever angle
Name
a=0deg+-5deg
b=53deg+-5deg

N:Pump normal
S:Stop the pump.
(1)No return spring
2.7 Additional device adjustment
2.7.1 Additional device 1
Name I/P WITH LOAD PLUNGER ADJ

h=2.7+-0.01mm Adjusting procedure for load plunger equipped pump with RSV (cam lock) governor (see service i
c=5deg30min+-30min nformation S.I. 434 for details).
At cam lift h+-0.01, set the camshaft c deg from the * mark in accordance with the timing adjustm
ent procedure.
2. Align the flyweight's timing tooth position and the lock pin groove and then fully tighten the flyw
eight to the camshaft. Then, remove the lock pin.
3. Adjust the maximum variation between cylinders and injection quantity.
4. Adjust using the pre-stroke adjusting shim so that the pre-stroke value is the value for 4/4 load
(standard point A).
5. After adjusting the pre-stroke, reconfirm that the injection quantity and the maximum variation b
etween cylinders are as specified.
6. At delivery, again fix the flyweight using the lock pin.

OT = Outside Tolerance (X is set)


101609-3612 ZEXEL test values diesel fuel-injection equipment 06/10/21 13:02:41 Page 4

2.7.2 Additional device 2


Name TAMPER PROOF

T1=7.16~9.12N-m(0.73~0.93kgf-m) Tamperproofing-equipped boost compensator cover installation procedure


T2=2.9~4.4N-m(0.3~0.45kgf-m) (1)After adjusting the governor and the boost compensator, tighten to the specified torque to brea
T3=2.9~4.4N-m(0.3~0.45kgf-m) k off the bolt heads.
(Tightening torque T = T1 maximum)
(2)After adjusting the governor and the boost compensator, tighten to the specified torque to brea
k off the bolt heads.
(Tightening torque T = T2)
(3)After adjusting the governor and the boost compensator, tighten to the specified torque to brea
k off the bolt heads.
(Tightening torque T = T3)
2.8 Timing setting
Name
a=55deg48min+-3deg
b=55deg48min+-3deg13min48sec
c=5deg30min+-30min

aa=11deg (1)Pump vertical direction


bb=0deg (2)Key groove position for No. 1 cylinder's cam lift h = cc (at BTDC aa).
cc=2.7+-0.01mm (3)Key groove position for No. 1 cylinder's beginning of injection (at point A after injection quantity
adjustment).
(4)Position of the key groove of the No. 1 cylinder at B.T.D.C. bb (fix the governor flyweight at this
position for delivery).
(5)B.T.D.C.: aa

OT = Outside Tolerance (X is set)

You might also like