M a x i m u m P r e s s u r e.

High Pressure Technology • Testing Equipment


Hydraulics • Pneumatics

Technical Data Sheet G500-2 (L)S-771-5U » Oil service !

Technical Data:
Air drive pressure: 1-10 bar / 14,5 - 145psi
Calculated Outlet Pressure at an air drive of 7,000 bar/ 101,500 psi
10 bar/145 psi:
Pressure ratio: 1:1,038
Displacement volume/double stroke 1.9 cm³/ 0.12 cu.inch

Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G500-2LS-771 • Page 1 of 3 • DB.01.01.12.13


Connections:
Inlet: Side inlet: 1/4 BSP
Outlet: Standard: 5U (5/8-18UNF)
Air drive: 3/4 BSP
G500-2 (L)S
single acting, double air drive head
Maximum operating tempreature: 60°C
(Only side inlet available) Net weight: 22.0 kg
Pressure and flow performances, please see enclosed graph.

Wetted materials of construction: Seal package: G500-2(L)S: Polyurethan, NBR


Pump Body: 1.6358
Piston: 1.4112 (hardened)
Fittings: 1.6358
Approximate Dimensions: Height: 462 mm
Depth: 211 mm
Width: 272 mm
Available Options: Side inlet G500-2(L)S
Special inlet and outlet ports, i.e. NPT G500-2(L)S-NPT
Special seal material to handle special fluids on request.

Available Accessories:

Air control units with filter pressure regulator, control pressure gauge and shut off valve: G500-2(L)S with C2
To protect the pump against excessive outlet pressures or to limit the outlet pressure, a safety valve G500-2(L)S with C2/SVair (The
can be fitted to the air control unit in the air drive line: required outlet pressure has to
be indicated.)

! For operating pressures above 4,000 bar (58,000 psi) common hydraulic fluids can’t be used. We recommend the use of
Maxifluid (Item Code: 1090.0270) which will remain in the liquid phase at pressure levels.

Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including
limitations of our liability, apply to all products and services sold.

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics

Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G500-2LS-771 • Page 2 of 3 • DB.01.01.12.13

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Leistungsdiagramm/Performance Graph G 500 -2LS- 771
Prüfflüssigkeit/Test Liquid: Wasser-Öl-Emulsion/Water Oil Emulsion ca. 1 - 10 cst

9000 3500
8 bar
8000 PBmax./Max.outlet pressure 7000 bar
3000
8 bar
7000
Hydraulics • Pneumatics

6 bar 2500
6000
6 bar
2000
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment

5000
4 bar
4000 4 bar 1500

Betriebsdruck/
Luftverbrauch/

Outlet Pressure (bar)


3000
Air consumption (lN/min)

1000
2000
500
1000

0 0

00
25
50
75
00
25
50
75
00
25
50
75
00

0, 0
0, 0
0, 0
0, 0
0, 1
0, 1
0, 1
0, 1
0, 2
0, 2
0, 2
0, 2
0, 3

Förderleistung/Flow (l/min)
Betriebsdruck bei/Outlet Pressure at 4 bar Betriebsdruck bei/Outlet Pressure at 6 bar
Betriebsdruck bei/Outlet Pressure at 8 bar Luftverbrauch bei/Air consumption at 4 bar
Luftverbrauch bei/Air consumption at 6 bar Luftverbrauch bei/Air consumption at 8 bar

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, [email protected]
Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G500-2LS-771 • Page 3 of 3 • DB.01.01.12.13