0% found this document useful (0 votes)
671 views11 pages

Release Notes GOM Software 2022

This document provides release notes for GOM Software 2022 Service Pack 2. It includes bug fixes and improvements compared to the previous version, such as a new end user license agreement, updated software versions including a new Python version, and new sensor firmware. It lists several resolved issues and bugs. Important information is provided about requiring administrator rights for updating to this version due to changes in digital certificate rules.

Uploaded by

Vinh Dương
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
671 views11 pages

Release Notes GOM Software 2022

This document provides release notes for GOM Software 2022 Service Pack 2. It includes bug fixes and improvements compared to the previous version, such as a new end user license agreement, updated software versions including a new Python version, and new sensor firmware. It lists several resolved issues and bugs. Important information is provided about requiring administrator rights for updating to this version due to changes in digital certificate rules.

Uploaded by

Vinh Dương
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Release Notes GOM Software 2022

Table of Contents
GOM Software 2022 Service Pack 2 ......................................................................................................................... 1
GOM Software 2022 Service Pack 1 ......................................................................................................................... 5
GOM Software 2022 ............................................................................................................................................... 8
Notes for Upgrading from GOM Software 2021 ....................................................................................................... 9
Version Information GOM Software 2022 .............................................................................................................. 10
System Requirements ............................................................................................................................................. 11

GOM Software 2022 Service Pack 2


Released at: 2023-02-27 (157456)

This software version contains some bug fixes and improvements in comparison to
GOM Software 2022 Service Pack 1, e.g.

• New revised end user license agreement


• New ZEISS Quality Suite version v4.3.1348.0
• New python version 3.9.16
• New Sensor firmware for ATOS Q, GOM Scan 1, ATOS 5, ATOS 5X, ATOS Capsule, ATOS LRX

Important information for future software updates

GOM Software 2022 Service Pack 2 (including ZEISS Quality Suite v4.3.1348.0) is highly recommended to avoid
problems for future software updates.

Known Issue for Issues for GOM Software 2022 Service Pack 2
Due to changed rules for digital signed certificates of ZEISS software products we need to incorporate a complete new
certificate type when renewing the certificate.

As consequence when updating the software to GOM Software 2022 Service Pack 2 within the ZEISS Quality Suite
additional administrator rights are required.

Excerpt of Changes
• [SW2022-10452] - EULA: The prior end user license agreement of GOM Software is replaced by a new end
user license agreement.
• [SW2022-3827] - Reporting - Screen presentation / Shortcut: Using the keyboard shortcut "F5" for starting
the screen presentation from the beginning works properly again. (CNR-65108-K0J2W7, CNR-76239-Z8C6T,
CNR-87602-B0S1Q9)
• [SW2022-9852] - CT Acquisition - Offline volume reconstruction: In "Properties" tab under Information the
exposure time was displayed incorrectly, this is fixed now.
• [SW2022-9894] - Automation: A bug is fixed which led to a crash when trying to initialize a sensor after an
error message is shown (for example "Incompatible automation module" or "VMR in the project is different to
the VMR for the connected hardware"). (CNR-93814-B1G3Q5, CNR-98753-H2V8V4)
• [SW2022-9978] - Live image mapping: A bug is fixed, which caused that the function "Live image mapping"
was not visible when using the GOM Software with a license combination that corresponds to prior known
"PONTOS Live". (CNR-88199-J3Z2X7)
Carl Zeiss GOM Metrology GmbH 1 - 11
Release Notes GOM Software 2022 GOM Software 2022 Service Pack 2

• [SW2022-9985] - Automation - GOM ROT 350: A bug is fixed which could have led to a short break of the
GOM ROT 350 Rotation table when starting continuous movement with the arrow keys. (CNR-90090-
N2G8N6)
• [SW2022-10013] - Rotation table measurements: A bug was fixed which led under specific circumstances to
re-open 'Enter measurement temperature' dialog repeatedly, when using the blue button in the rotation table
toolbar to start rotation table measurements.
• [SW2022-10082] - Open / Import Project: A bug is fixed where the software crashes when a new project is
imported or opened while a selection command such as "Select through surface" or "Select inside Cube" is
executed inside the software. (CAS-04349-P7G9H4, CAS-40160-H1G4C6)
• [SW2022-10097] - GD&T checks - Color deviation representation: A bug is fixed where the color deviation
representation of GD&T checks such as e.g. surface profile or parallelism was displayed only in red. For the
correction of existing faulty GD&T checks an "Edit Creation Parameters" is necessary. (CNR-91341-D4H2J5,
CNR-91113-L7F8W8, CNR-88927-M6V1C0, CNR-89391-W8Z7H0, CNR-90755-C7V8M9, CNR-92652-
W8D1Q0, CNR-91444-F3W6F7, CNR-93140-P9L3K4, CNR-93323-Q8C8R3, CNR-93412-N7Z6H0, CNR-93897-
S0J2T4, CNR-95554-P1W9X0, CNR-95647-V2F6L9, CNR-94805-C2Y4N7, CNR-96115-H2Y5G1, CNR-96280-
P0S7N5, CNR-98014-K1W6V3, CNR-98859-Y8T6D3, CNR-97028-R8D7Y9, CNR-99393-G5T7B5, CNR-99541-
C5X3S7, CNR-100251-C7M6T8, CNR-100271-T5L7Q6, CNR-100773-J7L5Z7, CNR-100729-R9M9Z6, CNR-
100955-Z2P3N1, CNR-101139-Z5P5G1, CNR-101492-L6R1C9, CNR-101475-D3S5N2)
• [SW2022-10127] - Distance Indicator: A bug is fixed which in very rare cases could have led to a crash of the
image acquisition server if activating the "Distance Indicator" on certain systems. Unfortunately, the fix will
lead to a reduced range of the distance indicator on affected systems (no outside 'red' area is shown). (CNR-
81541-S8K5X9, CNR-84441-H7G0D0, CNR-88195-K5X9J0)
• [SW2022-10162] - ATOS Kiosk - Asynchronous Evaluation: A possible crash is fixed when starting the GOM
Software 2022 with the ATOS Kiosk Interface with enabled asynchronous evaluation. (CNR-91742-P0B7D1,
CNR-92637-G0R7R6, CNR-93320-P4J9B6, CNR-94139-L5X3M4, CNR-95122-V0Z6P1, CNR-95840-Y9X3B3,
CNR-96528-V7Q9Z3, CNR-97077-M5G5P6, CNR-98698-D5W3K5, CNR-99170-W1L3P5, CNR-99413-
X1W7T4)
• [SW2022-10191] - GD&T / Position Tolerance with MMR: A bug is fixed where it was not possible to create a
position tolerance on a circle with MMR when using extracted surface. (CNR-91689-N0B4K2)
• [SW2022-10202] - Tilt and Swivel Unit: A bug is fixed which led to not correct updated tilt angles. (CNR-
92298-Q6C6W9, CNR-91679-M5V3X7, CNR-94979-F4N7P2, CNR-98090-X0H8F0, CNR-97982-B9G4K6,
CNR-98830-W9H1S7, CNR-99091-M4K6R7, CNR-98725-G4J2C2, CNR-98724-F0K9N2, CNR-100157-
Y3P8H0)
• [SW2022-10208] - Scripting - "Perform Mesh Adapting": A bug was fix which led to an error message
executing a script where the command "Perform Mesh Adapting" was recorded.
• [SW2022-10224] - Sensor Setup - PlusBox: A bug is fixed which led to a software crash when trying to setup
a PlusBox with an undefined measuring volume. (CNR-92388-C3X4D6)
• [SW2022-10230] - Mesh Coloring - Project Camera Image Contents On Mesh: A bug is fixed for "Project
Camera Image Contents in Mesh", which led to the software crash during recalculating. (CNR-92284-N3J9F5)
• [SW2022-10246] - GD&T - Datum Systems/Surfaces: A bug is fixed which led to a wrong error message when
using a surface as first datum for a datum system. (CNR-92441-S3G7J6)
• [SW2022-10285] - Reporting - Screen presentation: A bug is fixed which prevented the rotation of the 3D-
View of a report page in the presentation mode. (CNR-92640-K1M0M7, CNR-100294-Z3M2Z0)
• [SW2022-10286] - GD&T / Flatness - Color deviation representation: A bug is fixed which could led the
software crash if “Show color deviation representation” is set for the flatness of the element. (CNR-93312-
S2F8J5, CNR-94382-V6G8S8, CNR-96293-C8X2R5, CNR-96069-F3D8D9, CNR-97909-G1M8P2, CNR-99921-
P7V5T2)
• [SW2022-10313] - ATOS Sensor connection: A bug is fixed where ATOS Sensor was not able to connect with
a certain system configuration. (CNR-93414-Y2R4W1, CNR-93639-X7S6P8)
• [SW2022-10351] - Import CAD - Scripting: Importing CADs with the same assembly tree element name and
adding them to different parts can be handled by script now because the name of the assembly tree element
is getting unique now. In prior GOM Software 2022 versions the 2nd CAD was not added to the desired part
Carl Zeiss GOM Metrology GmbH 2 - 11
Release Notes GOM Software 2022 GOM Software 2022 Service Pack 2

but to the clipboard. Therefor existing scripts which imports such CADs to different parts need adoptions.
(CNR-92548-Y9J1V8)
• [SW2022-10369] - Surface Components / Surface component regions - Strain reference length: A possible
crash is fixed for the computation of the strain reference length. In prior GOM Software 2022 versions the
software could crash, when creating a Strain reference length check on specific Surface Components or when
using during the creation of a surface component the surface view "Reference length". Similar applied, when
creating a "Strain reference length" check on a surface component region based on certain surface
components. (CNR-92410-J8J4N4, CNR-96428-Y6M2L2, CNR-97560-F9Z9V3)
• [SW2022-10425] - Volume Inspection - Volume Defect Analysis: A bug was fixed which could cause wrongly
applied filter criteria, when creating Volume Defects.
• [SW2022-10429] - VMR / Scalebar fixture elements: A bug is fixed where it was not possible to create
scalebar fixture elements in some cases. (CNR-94511-C5M0F9, CNR-95145-R9V7J9)
• [SW2022-10445] - ATOS Sensor: A bug is fixed which led to an error message about an invalid calibration
after changing the sensor - if different sensors were used on the same system. (CNR-94114-N2Z2G9, CNR-
93948-N6T2D3, CNR-96936-M3F8M6, CNR-99162-X9F8H1, CNR-101063-D4R6D2)
• [SW2022-10451] - GOM Volume Inspect - Volume Acquisition: A bug was fixed, which prevented the user
from changing windows port for server / client communication in GOM Software.
• [SW2022-10474] - Export inspections by Report Page - Active actual mesh: A bug is fixed for exporting
inspection from a single selected report page. In prior GOM Software 2022 versions the exported file has
values from active actual mesh of the 3D View instead of from the ones shown in the report page. (CNR-
94869-C1S3H3)
• [SW2022-10485] - Image acquisition - ATOS 5 Plus 45M /ATOS 5X Plus 45M: a bug is fixed for the ATOS 5
and 5X with 45M Plusbox, where measurements could fail due to changed memory layout with the latest
firmware. (CNR-89969-J9R5B5, CNR-95540-C0X2R5, CNR-90615-R0Y2C7)
• [SW2022-10486] - GD&T Position computation: A bug is fixed where it was possible that some position
tolerances show a wrong actual result value after recalculation. (CNR-91812-P6R1Z1)
• [SW2022-10487] - Scripting - User-defined dialogs: A bug is fixed where in user-defined dialogs the "Selection
element" widget of type "Direction" was displayed incorrectly and was not usable as expected. (CNR-95629-
H7T7T8, CNR-95745-W6W3L4)
• [SW2022-10494] - Project Guide / Filter options - Linear Size tolerances: A bug was fixed which could led the
"Out of tolerance" filter option grayed out in the "Project Guide" and therefor unable to use for Linear Size
Tolerance. (CNR-95226-G3J8S7)
• [SW2022-10523] - GD&T / Datum Systems: A bug is fixed which lead the software to crash if the last element
of an ASME datum system is a symmetrical plane. (CNR-95991-B0D2R7, CNR-100060-V9M1L3)
• [SW2022-10546] - "Measuring Principle Fitting Element" - Slotted Holes / Rectangles: Now, the Measuring
principle "Fitting Element" may be also applied to Slotted Holes and Rectangles directly created on CAD data
(and not on section or curves) for measuring planning as it was already the case in prior software versions for
circles. (CNR-93178-B5M4Z0)
• [SW2022-10555] - GD&T - Flatness / "Edit Creation Parameters": A bug is fixed which led to the software
crash during recalculation of the project after changing values of Flatness Tolerances. (CNR-93459-S5P4Q7)
• [SW2022-10579] - Label templates - Add-ons: A bug is fixed which caused that not all label templates defined
initially and saved within an add-on (formally known as package) in GOM Software 2021 where visible and
use able in prior GOM Software 2022 versions. (CNR-94281-F0J6B8, CNR-93673-Y3M3M4, CNR-94705-
F7M5K9)
• [SW2022-10581] - Export inspections by Report Page - Active actual mesh: A bug is fixed for exporting
inspection from multiple selected report pages. In prior GOM Software 2022 versions the exported file has
incorrect values.
• [SW2022-10595] - Import NASTRAN: Import NASTRAN files works properly now, even with Japanese or
Chinese characters in the file name or path. In prior GOM Software versions such files were not imported
properly, and the software could crash. (CNR-95517-V7M9R7)

Carl Zeiss GOM Metrology GmbH 3 - 11


Release Notes GOM Software 2022 GOM Software 2022 Service Pack 2

• [SW2022-10623] - Calibration - ATOS Sensors: A bug is fixed which could have led to a software crash if
trying to calibrate an ATOS Sensor with a cross and automatic exposure time. (CNR-96310-D7J3W3)
• [SW2022-10633] - Initialize Sensor - Error handling: Error message in case of lack of sensor license has been
changed to inform user that the license for the sensor is invalid. (CNR-95697-C6M8H2)
• [SW2022-10666] - ATOS / ARAMIS Kiosk - Licenses: A bug has been fixed that caused an unexpected license
problem by running the Kiosk when using a free license besides a dongle with pro license. (CNR-91742-
P0B7D1, CNR-92637-G0R7R6, CNR-93320-P4J9B6, CNR-94139-L5X3M4, CNR-95122-V0Z6P1, CNR-95840-
Y9X3B3, CNR-96528-V7Q9Z3, CNR-97077-M5G5P6, CNR-98698-D5W3K5, CNR-99170-W1L3P5, CNR-
99413-X1W7T4)
• [SW2022-10669] - Gray Value Feature templates: Import of exported Gray Value Feature templates works
again. (CNR-98075-W4L5G8)
• [SW2022-10805] - GOM Correlate - Mask images / 2D projects: A possible crash is fixed when using the
"Mask images" option in the "Reduce Project Size" command in certain 2D projects. (CNR-94117-Q7X4S3)
• [SW2022-10842] - Tesselate Geometrical Element: A bug has been fixed that caused a crash on certain
tesselated geometrical elements. (CNR-99895-T0B9D6)

Carl Zeiss GOM Metrology GmbH 4 - 11


Release Notes GOM Software 2022 GOM Software 2022 Service Pack 1

GOM Software 2022 Service Pack 1


Released at: 2022-11-07 (156191)

This software version contains some bug fixes and improvements in comparison to GOM Software 2022, e.g.

• The GOM Software 2022 Service Pack 1 is usable also on Windows 11 22H2 systems
• New sensor firmware for ATOS Q, ATOS 5, ATOS 5X, ATOS LRX and ATOS Capsule
• New ZEISS Quality Suite version v4.1.1318.0
• several more bug fixes regarding GOM Volume Inspect, GOM Correlate, …

Notes for upgrading from GOM Software 2021

Please refer additionally the section Notes for upgrading from GOM Software 2021, because the
GOM Software 2022 contains compared with GOM Software 2021 several new firmware and drivers.

The GOM Software 2022 requires a new license. To update your license from GOM Software 2021 to the new
GOM Software 2022, please use MyGOM > License Update. Please add "GOM Software 2022" in the
respective comment field.

Excerpt of Changes
• [SW2022-9854] - ZEISS Quality Suite: The GOM Software 2022 Service Pack 1 includes a new ZEISS Quality
Suite version v4.1.1318.0.
• [SW2022-5972] - GOM Correlate - Measuring principle "Project Point onto Actual": In GOM Correlate projects
there is no longer an "automatic" option in the dialog of the Measuring principle "Project Point onto Actual".
Instead the first found surface component is preselected. (CNR-76335-Q4C4F0)
• [SW2022-8616] - Profile Form Analyses / Checks - Combined Labels: Now, using "Grouped Checks" label
templates on Profile Form Analysis elements with checks applied works as before in GOM Software 2021 and
the checks are displayed properly at the Profile Form Analysis elements. In prior GOM Software 2022 release
the checks were displayed by mistake at the section element used for the profile form analysis. Additionally,
when creating/editing checks on profile form analysis elements changing the used coordinate system is
possible again.
• [SW2022-9138] - GOM Correlate Pro - Reduce Project Size/Permanently Reduce Image Quality: When
aborting the command "Reduce Project Size By Permanently Reducing Image Quality" no longer an additional
"User abort" error dialog is displayed.
• [SW2022-9167] - GOM Volume Inspect Pro - "Initialize Sensor": The software no longer crashes when using
"Initialize Sensor" without a connected XRAY CT system. Instead an error message is displayed.
• [SW2022-9272] - GOM Volume Inspect - METROTOM 1: Using high resolution mode in the Capture Volume
dialog visualizes now the allowed region of interest for reconstruction.
• [SW2022-9430] - GOM Volume Inspect - Calibration: With GOM Software 2022 Service Pack 1 serveral
problems regarding sensor calibration are fixed, e.g. that the calibration was under circumstancse not
executed successfully.
• [SW2022-9510] - GOM Volume Inspect - "Capture Volume" / "Extend Geometry Description": A speficic
problem is fixed which could lead under circumstances to errors with volume capturing when "Extend
Geometry Description" is used.
• [SW2022-9534] - Gray value features: A problem is fixed which caused a wrong element representation in
measurement image view in the "Edit Creation" dialog of gray value features in case of used plane offset.
• [SW2022-9535] - Calibration information: A bug is fixed which led under circumstances to a different value
for "Height variance" between the calibration information dialog and the saved calibration information. (CNR-
86939-W3Y0C1)
• [SW2022-9551] - VMR - Exposure time "Automatic by matrix": A possible problem is fixed , which led in prior
GOM Software versions under special circumstances to abort of measurement series execution, when using
exposure time computation mode "Automatic by matrix". (CNR-84986-B1K0B7)

Carl Zeiss GOM Metrology GmbH 5 - 11


Release Notes GOM Software 2022 GOM Software 2022 Service Pack 1

• [SW2022-9607] - Scripting - "Dialog Editor" / Embedded images: A bug is fixed that led to missing embedded
images in the "Dialog Editor". (CNR-87470-Q7D3H6)
• [SW2022-9611] - Reports / Edit creation Parameters - Inspection Details: The "Show All Inspection Values"
option can be changed during editing a report page containing an "Inspection Details" placeholder.
• [SW2022-9639] - "Exit" Software: A very specific crash is fixed, that happens in rare cases when closing the
GOM Software after loading certain projects. (CNR-89676-C0J1P4, CNR-90086-R9H0P2)
• [SW2022-9681] - Export Elements - "Selected elements Only": If a nominal element with an applied
measuring principle is exported with "Selected elements Only", then the measuring principle is removed
unless the linked actual element is exported, too. (CNR-88374-P2P8G2)
• [SW2022-9697] - GOM Volume Inspect - METROTOM 1: A bug has been fixed that artifically limited the
maximum exposure time for the METROTOM 1 to 2000 ms.
• [SW2022-9700] - Clipping at Section / Reporting: A bug is fixed which led to not shown elements like labels
after restoring from reportpage 3D view if the clipping was made at a section because the section can be
slighlty offset. (CNR-86478-X4G6L3)
• [SW2022-9749] - GOM Volume Inspect - "Reconstruct Volume From Images": An error in the volume
reconstruction is fixed which could occur when the expert option for horizontal field-of-view extension is
disabled. (CNR-88708-H5W1M8)
• [SW2022-9776] - "Section View" - "Define Section Plane"/ Preferences: The values for option "By value" in the
"Define Section Plane" are displayed now properly with the number of decimal places of the length unit
defined in the preferences.
• [SW2022-9793] - GOM Correlate - Live Image Mapping / Image Acquisition: A problem is fixed which led to
flickering Live Image Mapping during the execution of measuring sequences. The same applies for "Start
Positioning".
• [SW2022-9796] - GOM Correlate - Acquisition Parameters: A bug with license mapping is fixed where it was
not possible to change the "Measurement Temperature" in the "Acquisition Parameters" dialog if you work
with GOM Correlate Pro but have no ARGUS licenses. (CNR-87703-B3H1Z2)
• [SW2022-9838] - Scripting - User-defined dialog / "Selection Element" widget: A bug is fixed that prevented
to select new values after previous deselection in the element selection of script dialog windows. (CNR-
69051-S5F2Z7)
• [SW2022-9857] - "Define Scan Area": The software no longer crashes when closing it while the "Define Scan
Area" is enabled in the Camera view.
• [SW2022-9889] - Constructing Points - Point Component: Points can be constructed again on point
components created in SW2021 or earlier. (CNR-89080-G5J7J5)
• [SW2022-9933] - Report pages - Export PiWeb: An bug has been fixed that caused the export of data from
report pages could not be completed in the "Export PiWeb" dialog. (CNR-89377-Q0K3W0)
• [SW2022-9957] - Polygonize project - Alignments / Gray Value Feature (Mesh Adaption): The polygonization
now computes the interactively defined initial alignments such as "3-2-1 Alignment" and blend gray value
features using mesh adaption properly with the mesh. (CNR-82315-J7P3T8)
• [SW2022-9967] - Measuring Principle Fitting Element: A very rare crash is fixed in combination with elements
created with "Measuring Principle Fitting Element". (CNR-90259-N4N0L6)
• [SW2022-9988] - Deformation measurement series - Orient measurement series: A possible crash is fixed
when using "Orient Measurement Series" to align different measuring projects together.
• [SW2022-10000] - GOM Volume Inspect - Measurement Preparation: A bug is fixed which could lead to Flat
Field creation with wrong exposure time.
• [SW2022-10011] - "Measuring Principle: Fitting Element" - Planes: Now it is possible to use the "Method"
"Gaussian best fit (outer)" when applying the "Measuring Principle: Fitting Element" to nominal planes. (CNR-
88059-H0P1K7)
• [SW2022-10012] - User-Defined Inspection Principles: A bug is fixed which drastically slowed down the
adding of user-defined inspection principles to several elements. (CNR-88453-C3Y2D0)
• [SW2022-10033] - ATOS Sensors - Sensor firmware: With GOM Software 2022 Service Pack 1 new sensor
firmware for ATOS Q, ATOS 5, ATOS 5X, ATOS LRX and ATOS Capsule sensors is provided. With this, e.g. an

Carl Zeiss GOM Metrology GmbH 6 - 11


Release Notes GOM Software 2022 GOM Software 2022 Service Pack 1

error is fixed that the objectives were not recognized correctly and therefor measuring was not possible.
(CNR-90946-T2R8Q8)
• [SW2022-10060] - Windows 11 22H2: The GOM Software 2022 Service Pack 1 is now usable also on
Windows 11 22H2 systems. Prior GOM Software 2022 versions crashed when started. (CNR-89348-G8X3L1,
CNR-89364-F9D4L5, CNR-89738-G8Y5N8, CNR-89876-V2M6P3, CNR-89903-K8X2J2, CNR-89913-G0L1T4,
CNR-90613-X1N4X2, CNR-90894-T5D8R9)
• [SW2022-10064] - Surface Components - Clicking points with Ctrl+LMB: Clicking points on surface
components with "Crtl"+"LMB" for constructing elements works now again as in GOM Software 2021 and
prior. In prior GOM Software 2022 the clicked point was snapped by mistake at the closest polygon point
instead of the clicked spot. The same applies for creating deviation labels on surface component analyses
elements. (CNR-91284-K5R4T9)

Carl Zeiss GOM Metrology GmbH 7 - 11


Release Notes GOM Software 2022 GOM Software 2022

GOM Software 2022


Released at: 2022-09-13 (Rev. 154413)

GOM software is continuously being developed and this is done in constant dialog with our customers. This way we
can support you better, you become more productive, save time and money. Here we show you the best new features
in the different sectors of GOM Software.

• With photorealistic rendering the user can simulate parts in digital assemblies and real environments and
assess the influence of light and shading
• The volume-based defect detection in GOM Volume Inspect allows for targeted user intervention to increase
the amount of detected defects
• GOM Blade Inspect offers a seamless integration with ZEISS CALYPSO for the analysis of blades, vanes and
blisks
• In GOM Correlate point components including coded points can now be easily analyzed and used for new
adapter and tracking workflows
• New CAD Converter supporting following formats NX 2007, Solid Edge 2022, Solid Works 2022,
Parasolid 34, Parasolid 34.1, ACIS 2021 1.0, Inventor 2022, Inventor 2023, Navisworks 2022, CATIA V5_6
R2022, JT 10.6 and Revit 2022, Creo 9, NX 2206 (2022 June version)
• New python version 3.9.7
• You may find an enhanced list of new features for the different software variants in the What's new
documents

Want to learn more about this year's GOM software? Click here for an overview. Or get to know various new and
enhanced features in the free Update Training.

Notes for upgrading from GOM Software 2021

Please refer additionally the section Notes for upgrading from GOM Software 2021, because the
GOM Software 2022 contains compared with GOM Software 2021 several new firmware and drivers.

Known Issues for GOM Software 2022


• METROTOM 1: There is a known issue with the calibration of the METROTOM 1 after switching from the
standard scintillator to the high resolution scintillator or vice versa. After a successful calibration, the live
image is not computed fully correctly. This can be fixed by deinitializing the sensor, waiting 30 seconds,
initializing the sensor and running the command "Capture Flat-Field Correction Data..." with the expert
parameter "Flat-field correction data for live image" checked.

Carl Zeiss GOM Metrology GmbH 8 - 11


Release Notes GOM Software 2022 Notes for Upgrading from GOM Software 2021

Notes for Upgrading from GOM Software 2021


Licenses
The GOM Software 2022 requires a new license. To update your license from GOM Software 2021 to the new GOM
Software 2022, please use MyGOM > License Update. Please add "GOM Software 2022" in the respective comment
field.

Firmware and Drivers


GOM Software 2022 contains compared with GOM software 2021 several new firmware and drivers

• New version of CodeMeter


• New version of the GigE image acquisition driver
• New version of TSCAN Hawk driver
• New sensor firmware / camera firmware for several ATOS Sensors (ATOS Compact Scan, ATOS Core,
ATOS Triple Scan, ATOS Capsule, ATOS 5, ATOS 5X, ATOS Q, GOM Scan 1)
• New GOM ScanCobot firmware is required. It is available in the GOM Library e.g. via MyGom > Software. The
GOM ScanCobot driver version must match the GOM Software version to be used with. This means, if you
want to use it with GOM Software 2021 you have to install the IPC_bundle-2022_*.bin on the GOM
ScanCobot (installing instruction see How to update GOM Software on GOM ScanCobot) and want to use it
later with the installed GOM Software 2021 you have to install the corresponding IPC_Bundle_2021_*.bin.

Using GOM Suite / ZEISS Quality Suite for upgrading to GOM Software 2022
For a smooth installation of the GOM Software 2022 without additional administrator rights using the GOM Suite at
least GOM Software 2021 Hotfix 7 is required, see also Release notes for GOM Software 2021. If an older GOM
Software 2021 version is installed, the installation of the GOM Software 2022 requires additional administrator rights
due to a newer certificate.

Additional notes for scripting


For the enhancements of GOM software 2022 including new software functionalities the software is reworked in
many areas. This may cause slightly different but better results in GOM Software 2022 compared to GOM Software
2021, when using a script created with GOM Software with the same input data. Additionally, within these changes
several script commands/parameters are renamed in GOM Software 2022. Therefore, it is recommended to use the
command "Tools" > "Update Script" in the right mouse button menu inside the script editor.

Renamed commands
• view.change_section_position was renamed to view.define_section_plane
• cad.project_points_on_plane was renamed to cad.create_element_by_projection_on_plane

Release Notes GOM Software 2021


Release Notes for GOM Software 2021 can be found here.

Carl Zeiss GOM Metrology GmbH 9 - 11


Release Notes GOM Software 2022 Version Information GOM Software 2022

Version Information GOM Software 2022


The table below lists additional software installers which comes with the GOM Software or is needed by it (depending on licenses). This software may be installed by using
the ZEISS Quality Suite or may be downloaded from the GOM Library for manually installation in case if it is not bundled within the GOM Software itself.

During the software installation of GOM Software 2022 also Microsoft ASP.Net Core Runtime will be installed if necessary.

3)
Microsoft ASP.Net Core Runtime
2)
1)

Camera driver ARAMIS 24M


Image Acquisition Driver
1)
ZEISS Quality Suite

T-SCAN hawk 2)
1)

colin3D 2)
CodeMeter
GOM Software 2022 Service Pack 2
4.3.1348.0 7.40b 13.04.005 9.0.0.240 3.0.5 2.36.02 6.0.14
Rev. 157456, Build 2023-02-23
GOM Software 2022 Service Pack 1
4.1.1318.0 7.40b 13.04.005 9.0.0.240 3.0.5 2.36.02 6.0.10
Rev. 156191, Build 2022-11-03
GOM Software 2022
4.0.1305.0 7.40b 13.04.005 9.0.0.240 3.0.5 2.36.02 6.0.8
Rev. 154413 Build 2022-09-09

1)
bundled within the GOM Software Installer – Update/Installation may be done with the ZEISS Quality Suite
2)
available via ZEISS Quality Suite (Internet connection required) or the GOM Library (GOM ID required)
3)
bundled within the GOM Software Installer – Update/Installation is done directly over the update/installation of GOM Software 2022 itself

Carl Zeiss GOM Metrology GmbH 10 - 11


Release Notes GOM Software 2022 System Requirements

System Requirements
User rights: Windows standard user rights are required to use GOM Software - Note: Administrator rights are needed for the initial installation.

GOM software is designed to process and evaluate large amounts of data. In order to smoothly create the measurement, documentation and evaluation of the data as
well as the calculations based on it, certain requirements for the underlying system and its hardware components must be considered.

To use the complete ZEISS Quality Suite functionality an internet connection is required.

Below you will find both the minimum requirements and the parameters we recommend for an optimal setup:

GOM Inspect GOM Correlate GOM Blade Inspect GOM Volume Inspect
Minimum Requirements
Processor Intel Core i3 Intel Core i3 Intel Core i3 Intel Core i3
RAM 4 GB 4 GB 4 GB 8 GB
Graphics card OpenGL compatible OpenGL compatible OpenGL compatible OpenGL compatible with at least
2 GB VRAM
Operation system Windows 10 (64 bit as minimum version 1607) with current security updates
2)
Recommended Requirements
Processor Intel Core i7 (QuadCore) Intel Core i7 (QuadCore) Intel Core i7 (QuadCore) Intel Core i7 (QuadCore)
RAM 16 GB or more 16 GB or more 32 GB or more 32 GB or more
Graphics card for Certified graphics card Certified graphics card Certified graphics board (CUDA Certified graphics board (OpenGL-
usage with GOM compatible) with at least 4 GB of compatible) with at least 4 GB
Software 1) VRAM VRAM
Operation system Windows 10 (64 bit 21H1) with current security updates

1)
Here you can find a list of certificated graphic cards > (GOM ID required)
2)
depending on used applications and projects

Carl Zeiss GOM Metrology GmbH 11 - 11