VERSION 1 ECOS / SUPERSTRUCTURE
ECOS Control and
Display Panel
Telescope / Lift Select Lamp
Boom Status Display Position of Cylinder head to
Section.
To High, To low Lamps
Section pins unlocked
(red) or locked (green)
Cylinder pins unlocked
(red) or locked (green)
Emergency Stop
Grove Manitowoc National Crane Potain
1 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
Crane Control Display Navigation Membrane Switches
F1: Display Status
F2: Power Unit Speeds / Critical Load Control
F3: Control Lever Emergency Program
F4: Telescope Status & Tele Automatic
F5: Set Telescope Status after Emergency Operation
“ESC”: Escape permits backing out of some selections
“Enter”: Permits Conformation of Data Selections
Grove Manitowoc National Crane Potain
2 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
System Start Up
Acknowledging Error Messages
Upon start up any error messages must be acknowledged by selecting the Enter
button once for each error message.
Grove Manitowoc National Crane Potain
3 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status
By selecting the F1 membrane switch you can display the
operating hours of all power units and possibly read off any existing
malfunctions.
Grove Manitowoc National Crane Potain
4 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status Menu Structure
Enter
Engine Status Report Telescoping Status Report
System Status Report Locking System Status Report
Main Hoist Status Report Slewing Status Report
Aux. Hoist Status Report Aux. Drive Unit Status Report
Critical Load Control
Derricking Gear Status Report Status Report
Grove Manitowoc National Crane Potain
5 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status
Use buttons to scroll to different screens.
Grove Manitowoc National Crane Potain
6 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status
Memory Error Sub-menu
You can call up the sub-menu memory error from this status display in order
to see already acknowledged error messages.
Press the membrane switch next to the status display to do so.
Grove Manitowoc National Crane Potain
7 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status
Memory Error Sub-menu
You can call up further existing errors with both of the membrane
switches next to the display.
Grove Manitowoc National Crane Potain
8 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F1 Display Status
Critical Load Control
The status of the critical load control is shown on the third line.
ON – critical load control is switched on
OFF – critical load control is switched off
ERROR – error has occurred
Grove Manitowoc National Crane Potain
9 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
By selecting the F2 membrane switch you can enter the maximum
speed of all power units.
Grove Manitowoc National Crane Potain
10 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
Menu Structure
Enter
Main Hoist
Auxiliary Hoist
Derricking Gear
Telescoping Gear
Slewing Gear
Critical Load Control
Grove Manitowoc National Crane Potain
11 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
You can scroll through all power units with both of the membrane
switches next to the display.
Grove Manitowoc National Crane Potain
12 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
Press the membrane switch to highlight and adjust normal speed.
Press the membrane switch to highlight and adjust jib speed.
Grove Manitowoc National Crane Potain
13 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
You can adjust the speed values with both of the membrane
switches next to the display.
Once the desired valve is displayed, select the Enter membrane switch to
save the entry.
Grove Manitowoc National Crane Potain
14 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
Press either membrane switch to highlight Critical Load Control status.
Grove Manitowoc National Crane Potain
15 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
Press the membrane switch to turn the Critical Load Control ON.
Press the membrane switch to turn the Critical Load Control OFF.
Press the Enter membrane switch to save the entry.
Grove Manitowoc National Crane Potain
16 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F3 Control Lever Emergency Program
If an error occurs with either of the control levers an error message will
be displayed. At this point you will be able to select the Control Lever
Emergency Program by selecting the F3 membrane switch.
Grove Manitowoc National Crane Potain
17 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F2 Power Unit Speeds / Critical Load Control
Menu Structure
Enter
Control Lever Right
Control Lever Left
Grove Manitowoc National Crane Potain
18 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F3 Control Lever Emergency Program
Once the F3 membrane switch has been selected operation of the
disabled control function can be performed by using the directional
arrow membrane switches on the display along with the control lever.
X – Axis = Y – Axis =
Grove Manitowoc National Crane Potain
19 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
Selecting the F4 membrane switch opens the Telescoping display.
This screen allows you to monitor current telescope status or enter
automatic telescoping mode.
Grove Manitowoc National Crane Potain
20 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
Telescope Status
The Telescope Status shows the current position of each telescoping
section. The above example shows all sections are at 0% extended.
Grove Manitowoc National Crane Potain
21 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
Telescope Cylinder Unlocked
When the telescope cylinder is unlocked the display shows the current
length in feet or meters of the telescope cylinder in the lower right corner of
the display.
Grove Manitowoc National Crane Potain
22 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
> 35 <
Telescope Cylinder Pinned to a Section
When the telescope cylinder is pinned to a section the display shows which
section the cylinder is pinned to in brackets > < along with the percentage of
extension. The lower left corner of the display shows the telescoping section
pinned to and the lower right corner shows the extension percentage.
Grove Manitowoc National Crane Potain
23 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 0 - 0 - 0 - 0
Programming Tele Automatic
Selecting the F4 membrane switch while in the telescope status screen
opens the Set Tele Automatic screen. In addition the entry request ( )
flashes on the numerical value for T1.
Grove Manitowoc National Crane Potain
24 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 50 - 0 - 0 - 0
Programming Tele Automatic
Use the membrane switches to scroll between sections T1 – T5.
Use the membrane switches to change the extension value for a
section. Once all values are entered selecting the Enter membrane switch
activates the system.
Grove Manitowoc National Crane Potain
25 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F4 Telescope Status & Tele Automatic
Flashing Warning Lights
If the four green light diodes above the first line flash three times after the
tele automatic has been started, you have entered a telescoping which is not
permissible according to the lifting capacity table. Furthermore, the display
shows the submenu for entering and you can enter a new permissible
telescoping.
Grove Manitowoc National Crane Potain
26 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE
F5 Set Telescope Status after Emergency Operation
SET TELESCOPE STATUS
T1 - T2 - T3 - T4 - T5
0 - 0 - 0 - 0 - 0
Key Code: _ _ _ _
Selecting the F5 membrane switch enters the set telescope status after
emergency operation. In order to select the menu the switch must be pressed
three times in a row within 2 seconds. This menu is required if telescoping was
done in emergency mode. Once the status is set, a key code must be entered
to resume operation. (Enter - Up Arrow - Down Arrow - Enter)
Grove Manitowoc National Crane Potain
27 Display Features