Version 25.x
January 15, 2017
Table of Contents
Scope................................................................................................................................................................ 2
1. Hardware Description............................................................................................................................... 3
2. T-BERD 5800 Setup and Local Connectivity verification ...................................................................... 4
2.1 Information requirements .................................................................................................................. 4
2.2 Test Setup .......................................................................................................................................... 5
3. T-BERD 5800 Layer 2 Traffic Test Procedure ........................................................................................ 9
3.1 Information requirements .................................................................................................................. 9
3.2 Test Setup .......................................................................................................................................... 9
3.3 Running the Test ............................................................................................................................. 10
3.4 Saving Test Results ......................................................................................................................... 11
3.5 Saving Configuration Template ...................................................................................................... 12
3.6 Ending the Test ............................................................................................................................... 12
Scope
This document describes how to measure Layer 2 Metro Ethernet performance with the T-BERD 5800v2 or
T-BERD 5800-100G using the Ethernet Layer 2 Traffic test selection. The Layer 2 Traffic test selection
can be used to measure key performance indicators (KPIs) including Throughput, Delay, Jitter, Frame
Loss, and BERT. Compared to RFC-2544 and Y.1564 SAM Complete tests, the Layer 2 Traffic Test offers
the advantage of allowing the user to make real-time changes and view real time test results to characterize
and troubleshoot network performance. It also allows for Bit Error Rate (BER) measurement. This
document is not intended to be a user guide. This Method of Procedure (MOP) should be used in
conjunction with the T-BERD User’s Guides for detailed explanation of all testing options.
The Loopback device may be another Viavi test set (SmartClass, HST-3000 or T-BERD), a Viavi Test
Head (QT-600), a Viavi-compatible NID, a Viavi JMEP loopable SFP, or an ALU 7705 Service
Aggregation Router configured for IEEE 802.1ag Connectivity Fault Management (CFM) loopback.
Fiber Loopback Cables (Hard Loops) may only be used if there is no Layer 2 switching equipment on the
link.
If your T-BERD is Strata Sync enabled, use StrataSync to update your software. Otherwise, go to
http://updatemyunit.net/ for software update instructions. StrataSync can also be used to create
configuration templates and download configuration files for this procedure.
1. Hardware Description
The T-BERD 5800 is a portable test tool for Ethernet testing. The product can also be optioned to support
T1, DS3, SONET, OTN, Fiber Channel, CPRI, and OBSAI. Test connections are made from the top of the
mainframe. Menu selections are made from the T-BERD color touch screen. The T-BERD 5800v2 uses
RJ-45 ports, labeled 10/100/1000 for copper testing (10/100/1000BASE-T) and SFP+ ports for optical
testing:
The T-BERD 5800-100G uses the SFP+ port for both copper and optical testing. The RJ-45 10/100/1000
port is only used for dual port testing and requires option C5DUALPORT:
3. Clean & Inspect Ensure the fiber and connectors are clean
using a Fiber Inspection probe.
4. Connect Connect the SFP, QSF, or CFP4 to the port under test.
Use orange or aqua Multimode jumper cables
for 850 nm 1000BASE-SX or 10GBASE-SR.
Use yellow or dark blue Single Mode Fiber jumper
cables for 1310 nm 1000BASE-LX or 10GBASE-LR,
40GBASE-LR4, or 100GBASE-LR4.
Use CAT 5E or better cable for copper
10/100/1000BASE-TX connections.
Use 12-fiber MPO trunk cables for 40GBASE-SR4.
Use 24-fiber MPO trunk cables for 100GBASE-SR10.
5. Load Test If a shortcut for this test is stored on the T-BERD, use the Test List to launch
the test, and proceed to step 8.
6. All Test If the Select Test menu is hidden, tap to display the menu.
7. Select Test In the Select Test menu, , at the top left corner of the screen,
choose one of the following:
For 10BASE-T, 100BASE-T, or 1000BASE-T Electrical Ethernet testing:
Ethernet►10/100/1000►Layer 2 Traffic►Terminate or
Ethernet►10/100/1000►Layer 2 Traffic►P1 Terminate.
For 100BASE-FX Optical Fast Ethernet testing:
Ethernet►100M Optical►Layer 2 Traffic►Terminate or
Ethernet►100M Optical►Layer 2 Traffic►P1 Terminate.
For 1000BASE-SR, 1000BASE-LR, or other GigE Optical Testing:
Ethernet►1GigE Optical►Layer 2 Traffic►Terminate or
Ethernet►1GigE Optical►Layer 2 Traffic►P1 Terminate.
For 10GBASE-SR, 10GBASE-LR, other 10GigE Optical Testing:
Ethernet►10GigE LAN►Layer 2 Traffic►Terminate or
Ethernet►10GigE LAN►Layer 2 Traffic►P1 Terminate.
For 40GBASE-SR4, 40GBASE-LR4, other 40GigE Optical Testing:
Ethernet►40GigE►Layer 2 Traffic►Terminate or
Ethernet►40GigE►Layer 2 Traffic►P1 Terminate.
For 1000GBASE-SR4, 40GBASE-LR4, other 40GigE Optical Testing:
Ethernet►100GigE►Layer 2 Traffic►Terminate or
Ethernet►100GigE►Layer 2 Traffic►P1 Terminate.
9. Auto Negotiation For 10/100/1000 Electrical and 1GigE Optical tests, select the Ethernet tab
of the Quick Config and set Auto Neg. to the same value as the Ethernet port
under test.
10. Turn Laser On For 1GigE, 10GigE, 40GigE, or 100GigE Optical tests, select the Laser tab
in the Actions panel, and press . The button will turn yellow and be
relabeled .
11. Restart Test Press the Restart Soft Key , on the right side of the screen.
If you are using the T-BERD as a loopback device, proceed to step 13.
13. Setup Press the Setup Soft Key, , and select the Ethernet menu.
14. Results Press the Results Soft Key, , to view the progress of the test.
1. Setup Press the Setup Soft Key , on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other values at
default, unless specified in the Work Order.
1. Results Press the Results soft key to view the results screen.
2. Loop Up If the Loopback device is an ALU 7705, or the loopback device is already in
Local Loop Back (LLB) mode, proceed to step 3.
3. Start Traffic Press . The button will turn yellow and be relabeled .
4. Restart Test Press the Restart Soft Key , on the right side of the screen.
Allow the Test to run for the desired duration. At the end of the duration,
verify that the Left Result window still displays “ALL SUMMARY
RESULTS OK.”
6.
1. User Information In the T-BERD’s Report Panel, , select and enter comments
in the Device Under Test and Tester Comment tabs. Press to
continue.
2. Create Report Tap to display the T-BERD’s Reports panel. Tap , enter a
3. Connect USB Connect a USB Flash Drive to USB port on the side of the T-BERD.
1. Stop Traffic Press . The button will turn yellow and be relabeled . If the
Loopback device is not an ALU 7705, T-BERD, HST-3000, QT-600, JMEP,
or Viavi compatible NID, proceed to step 8.
2. Loop Down If the Loopback device is a T-BERD, HST-3000, QT-600, JMEP, or other
3. Turn Laser Off For 1GigE, 10GigE, 40GigE, or 100GigE optical tests, select the Laser tab
in the Actions panel, and press . The button will turn grey and be
relabeled .
Shutdown Press and hold the ON/OFF button to turn the unit off.