Interface Unit If2500
Interface Unit If2500
Interface Unit If2500
IF-2500
i
TABLE OF CONTENTS
Overview............................................................................................................... 1
Cables ................................................................................................................... 2
Mounting............................................................................................................... 2
Grounding ............................................................................................................ 2
Maintenance ......................................................................................................... 5
SPECIFICATIONS
PACKING LIST
OUTLINE DRAWING
INTERCONNECTION DIAGRAM
ii
Overview
The interface for the dual GPS navigator receives data from two GPS navigators and chooses
one to output in accordance with priority order. Output data is converted to NMEA current loop,
IEC 61162-1 or contact signal and output.
12-24 VDC
Input 2 Output 5
(GPS navigator) Output 6
Receiving Error Alarm
Cross Track Error Alarm
Arrival Alarm
1
Mounting Selection of output data format
This unit does not have power switch. If you The output data format is selectable by
do not connect the IF-2500 to power changing a jumper block; A for IEC61162-1
switchboard or circuit breaker, install an and B for NMEA. For example, to select
external power switch (local supply), locating NMEA for J4, change the jumper block from A
it near the IF-2500. to B on JP401 and JP402. Do the same on J5
thru J9.
Factory setting
Current
Output Jumper IEC61162-1
loop
(A)
(B)
J4 JP401/JP402 !
J5 JP501/JP502 !
J6 JP601/JP602 !
J7 JP701/JP702 !
J8 JP801/JP802 !
J9 JP901/JP902 !
Cable fabrication
Use the following cables (Japan Industrial
Standard cables) or the equivalents.
Armor
Sheath
Shield
• All dimensions in millimeters. φ = 10.1 mm
• For added support, use nuts, bolts and Conductor
S = 0.75 mm 2
washers instead of woodscrews. φ = 1.11 mm
• Leave sufficient space at the sides and rear
of the unit for maintenance and servicing.
CO-SPEVV-SB-C 0.2x2P
Current loop or IEC 61162-1 signal
Grounding Vinyl sheath
To prevent mutual interface, run a ground Armor
wire between the earth terminal on the unit
and ship’s superstructure. Sheath
Shield
φ = 10.5 mm
Conductor
S = 0.2 mm 2
φ = 0.6 mm
2
Fabrication of CO-SPEVV-SB-C 0.2X2P
75 mm
Armor
35 mm
Sheath
33 mm
Shield
28 mm
3 mm
Earth cable
Cut unused cores and solder them to shield.
3 mm 15 mm 30 mm
(Supplied)
Heat shrink tube Fix the cable with
Twist and solder the cable clamp
15 mm at this location.
3
10-35V J1
Power
FUSE 0.5A
Alarm output 3
J12
Alarm output 2
J11
Alarm output 1
14P0285
J10
Output port 5
B A
A Output port 3
B
B A J6
A
B Output port 2
B A
A J5
B B
A A Output port 1
A J4
B A
B Output port 6
B
A J9
Input port 2
J3
S1
Input port 1
J2
A: IEC61162-1
Jumper
B: Current loop
Parts location
4
Maintenance CR2 Lights when receiving NMEA data
from J2.
Self test 1
CR4 Lights when sending NMEA data
The unit performs an internal self-check in to J4 thru J9.
the following sequence each time power is CR6 Blinks every second.
turned on. CR7 Lights when ROM error is
1. LEDs CR7 to CR10 blink twice every 2 detected.
seconds. CR8 Lights when RAM error is
2. ROM and RAM are tested. detected.
3. LED CR6 blinks every second for normal CR9 Lights when SIO error is detected.
operation. If an error is detected during CR10 Normally off.
the test, the corresponding LED is turned
on. 5. Remove the connector from J4 and plug
• When CR7 is on, ROM is defective. it into J5, J6, J7 and J8 successively,
confirming that CR2 and CR9 light as
• When CR8 is on, RAM is defective.
below for each port. Then, remove the
XH6P-XH4P short connector assy., plug
Self test 2 in the XH6P-XH5P short connector assy.
The test requires an external loop to check between J2 and J9, and confirm that CR2
I/O. Follow the steps below to carry out the and CR9 light as below.
test. CR2 Lights when receiving NMEA data
1. Set the DIP switch #4 of S1 to the ON at J2.
position. CR9 Lights when SIO error is detected.
2. Temporarily disconnect input and output
6. Remove the XH6P-XH5P short
connectors J2 and J4.
connector assy. Plug in the XH6P-XH4P
3. Construct a pair of short connector
short connector assy. between J3 and J4,
assemblies as below. J5, J6, J7 and J8 successively. Confirm
J2 that LEDs light or blink as below.
For J4, J5, J6 ,J7 and J8 XH6P
1 NC Remove the XH6P-XH4P short
XH4P 2 NC connector assy., plug in the XH6P-XH5P
RS422_OUT_A 1 3 RD_H short connector assy. between J3 and J9
RS422_OUT_B 2 4 RD_C
3
and confirm that the LEDs light or blink
NC 5 NC
GND 4 GND
as below.
6
CR3 Lights when receiving NMEA data
at J3.
For J9 XH6P J2 CR4 Lights when sending NMEA data
1 NC
XH5P 2 NC to J4 thru J9.
RS422_OUT_A 1 3 RD_H CR6 Blinks every second.
RS422_OUT_B 2 4 RD_C CR9 Lights when SIO error is detected.
NC 3 5 NC The relay contact signal output is turned on
NC 4 6 GND
and off alternately every second during the
GND 5
test.
Short connector assy
Fuse replacement
4. Connect the XH6P-XH4P short connector
If the fuse blows, find the cause of the
assy. between J2 and J4.
problem before replacing it. Do no use a fuse
5. Confirm that each LED lights according
rated more than 0.5A, since it may cause
to equipment status as follows:
more serious damage to the equipment.
5
FURUNO
This equipment is used for distribution of navaids data from navigation equipment. It provides
six outputs each from two independent inputs. Alarm signal is also available to distribute three
outputs from two independent inputs.
SP-1 E4408S01C
14CL-X-9851-1 1/1
PACKING LIST IF-2500
1.(*1)印のユニット及び部品コードは架空コードに付き注文用には使用できません。
(*1)Code numbers are not allowed to order as dummy code.
インターフェイスユニット
INTERFACE UNIT
IF-2500
J1(VH2P) J4(XH4P) CO-0.2x2P OR 出力 OUTPUT
VCTF1.25x2C/VH2P,3m,φ7.4 TTYCS-1 *1
12-24VDC 1 DC+ TD-H/TD-B 1 IEC61162-1/
A P
2 DC-
*2
TD-C/TD-A 2
P
CURRENT LOOP
NC 3
GND 4
J2(XH6P)
1 NC
CO-0.2x2P OR 2 NC J5(XH4P) CO-0.2x2P OR 出力 OUTPUT
航法装置 TTYCS-1 *1 TTYCS-1 *1
3 RD-H TD-H/TD-B 1 IEC61162-1/
NAVIGATOR P *2 P
4 RD-C TD-C/TD-A 2 CURRENT LOOP
5 NC NC 3
データ入力 DATA INPUT 6 GND GND 4
IEC61162-1
優先順位 (Priority): J2 > J3
J3(XH6P) J6(XH4P) CO-0.2x2P OR 出力 OUTPUT
1 TTYCS-1 *1
NC TD-H/TD-B 1 IEC61162-1/
CO-0.2x2P OR *2 P
航法装置 2 NC TD-C/TD-A 2 CURRENT LOOP
TTYCS-1 *1
NAVIGATOR 3 RD-H NC 3
P
4 RD-C GND 4
5 NC
6 GND
J7(XH4P) CO-0.2x2P OR 出力 OUTPUT
B TD-H/TD-B 1
TTYCS-1 *1
IEC61162-1/
*2 P
TD-C/TD-A 2 CURRENT LOOP
NC 3
GND 4
J11(XH3P) CO-0.2x2P OR
TTYCS-1 *1 アラーム出力(オフトラック)
ALARM-OUT2-H 1
P ALARM OUTPUT (OFF TRACK)
ALARM-OUT2-C 2
GND 3
J12(XH3P) CO-0.2x2P OR
TTYCS-1 *1 アラーム出力(受信不良)
ALARM-OUT3-H 1
P ALARM OUTPUT (RECEIVING ERROR)
ALARM-OUT3-C 2
GND 3
アース銅板 *1
注記 COPPER STRAP
*1)造船所手配。
D *2)内部の設定で切替え。
NOTE
*1. SHIPYARD SUPPLY.
*2. SELECT CURRENT LOOP OR IEC61162-1 BY INNER SETTING.