Intercom Datasheets
Intercom Datasheets
Handset Module
Basic Terminal
–– High resistance against chemicals and physical impact –– Large buttons and label areas
–– Suitable for extreme ambient conditions at temperatures –– Fast, targeted access to specific Intercom stations, automated
up to +70°C announcements with pre-recorded messages, RF conference calls,
door and gate controls
Investment protection –– Console unit can be tilted to adjust to ambient seating and
viewing conditions
–– Upwards compatible
–– High product life cycle combined with long-term availability
Precautions
–– When opening the stations ESD precautions must be observed.
–– The stations may only be opened by authorised service engineers.
–– Further mounting instruction see page 17.
Restriction Video:
–– Video can not be switched over WAN networking via G8-WAN, G3-WAN!
Power supply:
–– Power supply must be connected to TFT display PCB (for supply via PoE and external supply).
–– The device can not be supplied with PoE and external power supply simultaneously. But if desired, an appropriate configuration of the
switch is required (Ethernet port may not be blocked)!
Connection
DC+
20 V DC – 30 V DC
DC–
IP Uplink (PoE)
PoE
(to Intercom Server)
DC+
DC–
Jumper
Power supply:
for fixing
cable straps
Connection for
direct dialling modules
(CDDD 32P) OUT 1
OUT 1
External
loudspeaker module
MUTE
OUT 2 GND
OUT 2 LINE–
LINE+
Gooseneck
microphone
(CDMI 50P HD)
GND
IN 1
IN 2
IN 3
Headset
Ethernet connection: The RJ 45 socket on the TFT display PCB must be used! (CDMI 50P HD or CDHD 50P)
Handset
(CDHS 50P)
Precautions
–– When opening the stations ESD precautions must be observed.
–– The stations may only be opened by authorised service engineers.
–– Further mounting instruction see page 17.
Connection
External
loudspeaker module
MUTE
OUT 2 GND
OUT 2 LINE–
LINE+
Gooseneck
microphone
(CDMI 50P HD)
GND
IN 1
IN 2
IN 3
Headset
IP Uplink (PoE) (CDMI 50P HD or CDHD 50P)
(to Intercom Server)
handset
(CDHS 50P)
Precautions
–– When opening the stations ESD precautions must be observed.
–– The stations may only be opened by authorised service engineers.
–– Further mounting instruction see page 17.
Connection
–– The first direct dialling module is connected to the Basic Terminal with the included ribbon cable.
–– All further direct dialling modules are connected to the previous direct dialling module.
CD 800P I
CDDD 32P CD 810P I
BOC2 BOC2
TFT-Displayplatine
External
power supply
20 V DC – 30 V DC
Connection for
direct dialling modules
CDDD 32P
External
power supply
20 V DC – 30 V DC
Technical Data
IP rating: IP 20
Benefits
Front panel: Polycarbonate –– The Touch Screen Module allows perfect integration of Commend soft-
ware products into the control desk solution. It is possible to run
Display: TFT-colour display with scratch-resistant glass,
– Direct dialling modules of the Intercom Client
resolution 800 x 600, touch function,
display size 8.4 inch – Video monitor modules of the Intercom Client
– Studio web client
Operation System: Windows 7 Embedded
– It is possible to integrate third-party software products like building
Processor: Intel Atom n2800 / 1.86 GHz management systems or video systems into the control desk solution.
RAM: 2 GB SDRAM – Touch screen for simple and intuitive operation
Memory: CF memory 16 GB
including 8 GB for operation system
Connection: TRS Connector 3.5 mm, DVI-I port,
Extent of supply
2x USB 2.0, 2x RJ 45 LAN port – Touch Screen Module CDTS 50P
Power supply: 12 VDC; – Rear housing incl. connection module and mounting material
power supply unit: PA30W12V – Power supply unit inclusive adapter EU, US, UK, AUS with connection
Operating temperature range: 0° C to 40° C cable 98 inch.
(32° F to 104° F) – Short reference
Storage temperature range: –20° C to 70° C
(–4° F to 158° F)
System Requirements
Relative humidity: up to 80% not condensing
– For installation, mouse and keyboard may be required
Mounting: with included rear housing
can be installed in control desks or as desktop version – To run the Video monitor and the Direct Dialing Modules of Intercom
Client PRO/CCT version 3.0 or higher is necessary
Measurements: with included rear housing
W 262 mm, H 196 mm, D 45 mm (see page 17) – It is not possible to run a SQL server on the Touch Screen Module
Precautions
–– The Touch Screen Modules may only be opened by authorised service engineers.
–– The Touch Screen Modules has to be mounted in a position where the air convection on the back side and upper side is garanteed.
–– Further mounting instruction see page 17.
WARNING!
Do not cover heatsink
and ventilation of the device!
Strap to release
RJ 45 plug
Connection
–– Power supply with PA30W12V (in extent of supply)
–– USB 2.0 ports can be used to connect e.g. a mouse, keypad or external storage.
–– DVI-I port for connection of external monitors (maximal resolution full-HD 1920 x 1080).
–– The Touch Screen Module can be included into a LAN network by using the RJ 45 ports. It is also possible to build a network-bridge.
–– Line-Out for connection of an external loudspeaker.
Line-Out
TRS connector
3.5mm Klinke
Power Supply:
12VDC
Note:
The LED ring of the gooseneck microphone coupled with the RED colour
from the multifunction LED of the Basic Terminal.
The magnets contained in the handset CDHS 50P can affect operation of
certain medical devices and electronic systems under certain circumstances.
Please insure that the magnet (and the handset containing the magnet) keep
at least 30 cm (11.8 in) distance to credit cards, floppy discs and any other
magnetically sensitive devices.
For people carrying hearing aids or pacemakers, please pay
attention to the safety warnings of these devices.
Accessories
System Requirements
–– GE 800 (min. PRO 800 2.1) with G8-IP/G8-IP-32 and Feature Level D*
–– GE 300 (min. PRO 800 2.1) with G3-IP and Feature Level D*
–– IS 300 (min. PRO 800 2.1) with subscriber Feature Level D*
–– Configuration software min. CCT 800 2.1
–– Configuration software IPStationConfig (included in Setup of CCT 800 2.1)
* Note: Basic Terminals are automatically recognized in the system as “control desk”. If no direct dialling modules CDDD 32P are connected and no control desk
function is required, Feature Level “B” or “C” of the subscriber card is sufficient.
QoS Requirements
–– Maximum One-Way-Delay 100 ms
–– Delay-Jitter not above 50 ms
–– 0% packet loss for perfect audio quality
Bandwidth
–– The required bandwidth depends on the desired number of speech links:
–– Bandwidth incl. protocol overhead per IP-Intercom terminal, for upload and download:
3.5 kHz 7 kHz 16 kHz
Bandwidth (speech and date without video): 96 kBit/s 96 kBit/s 143 kBit/s
Speech is compressed to: G.711 standard G.722 standard G.722 standard
80% 0,13 Mbit/s 0,25 Mbit/s 0,63 Mbit/s 1,26 Mbit/s 1,89 Mbit/s 2,51 Mbit/s 3,14 Mbit/s 3,77 Mbit/s
100% 0,16 Mbit/s 0,32 Mbit/s 0,80 Mbit/s 1,60 Mbit/s 2,39 Mbit/s 3,19 Mbit/s 3,99 Mbit/s 4,79 Mbit/s
80% 0,36 Mbit/s 0,71 Mbit/s 1,78 Mbit/s 3,56 Mbit/s 5,34 Mbit/s 7,12 Mbit/s 8,90 Mbit/s 10,69 Mbit/s
100% 0,45 Mbit/s 0,90 Mbit/s 2,24 Mbit/s 4,48 Mbit/s 6,72 Mbit/s 8,97 Mbit/s 11,21 Mbit/s 13,45 Mbit/s
Installation
Mounting Instructions
–– When opening the stations ESD precautions must be observed.
–– The faceplates are fastened to the rear housings via screws from behind. Therefore the control desk surface must be accessible from the rear.
–– Before mounting in desk, break out the mounting openings from the rear housing.
–– The extent of supply includes screws for sheet metal (6 pcs. M3.5 mm x 9.5 mm Tx10) and wood screws (6 pcs. M3.5 mm x 30 mm Tx10) for mounting in
desks.
–– For placing on desks the desk kit CDDK is available. Per Basic Terminal, direct dialling module and touchscreen module one CDDK is required.
Variable position of
optional desk kit
238,50 (9.3)
130 (5.1)
(CDDK)
196 (7.7)
α
120 (4.72)
Mounting openings
178 (7)
45 (1.8)
186 (19.1)
242 (9.5)
186 (19.1)
120 (4.7)
120 (4.7)
220 (8.7)
110 (4.3)
Commend
The development and manufacturing processes are certified in ALGERIA AUSTRALIA AUSTRIA BELGIUM BRAZIL CANADA CHINA CROATIA CZECH
accordance with EN ISO 9001:2015. REPUBLIC DENMARK FINLAND FRANCE GERMANY HUNGARY ICELAND INDIA IRELAND
ISRAEL ITALY LIECHTENSTEIN LUXEMBURG MOROCCO NETHERLANDS NEW ZEALAND
NORWAY POLAND PORTUGAL RUSSIA SERBIA SINGAPORE SLOVAKIA SLOVENIA SPAIN
SOUTH AFRICA SWEDEN SWITZERLAND TUNISIA UNITED KINGDOM USA
www.commend.com
Series Y-TU970H
Vandal resistant IP emergency call station for Tunnel Intercom applications
Weather-
Fully Rugged proof
IP-based construction
IP66
Product details
Series Y-TU970H versions Housing components
Y-TU970H Rubber grommet (waterproof seal)
Emergency call station without buttons:
Magnetic hook switch
Case cover
Y-TU970H-KY
Emergency call station with full keypad:
Cover spring
Case screw
Handset cable
Y-TU970H-3B
Emergency call station with 3 function buttons:
Series Y-TU970H
Technical Specifications
Technical data
IP rating acc. EN 60529:IP66
Operating temperature range: –40 °C to +70 °C (–40 °F to +158 °F) System requirements
Storage temperature range: –40 °C to +70 °C (–40 °F to +158 °F)
IoIP
Relative humidity: up to 95%, not condensing Intercom Server
Power supply: PoE (Power over Ethernet): –– GE 800 (min. PRO 800 5.0, min. base licence PRO 1) with G8-IP
IEEE 802.3af standard –– GE 300 (min. PRO 800 5.0, min. base licence PRO 1) with G3-IP
power consumption of the terminal device: –– IS 300 or G8-IP-32 (min. PRO 800 5.0, min. base licence PRO 1)
Class 0 (0.44 to 12.96 W) –– VirtuoSIS (min. version 5.0, min. base licence PRO 3)
Cabling: min. Cat. 5 Configuration software
–– min. CCT 800 5.0 (build 1017)
Protocols (IoIP): IPv4, UDP, DHCP, RTP, RTCP, SNMPv2c, SNTPv4
–– IP Station Config (included in setup of CCT 800)
Protocols (SIP): IPv6 ready,
IPv4, TCP, UDP, HTTP (RFC 2617, RFC 3310), SIP
RTP (RFC 3550), RTCP, DHCP, SDP (RFC 2327),
SIP (RFC 3261), SNMPv2, STUN, TFTP, URI (RFC 2396), –– Compatible SIP server (see page TE | 2)
DTMF Decoding (RFC 2876, RFC 2833), –– VirtuoSIS (min. version 5.0, min. base licence PRO 3)
SIP User Agent (UDP RFC 3261), –– GE 800 with G8-VOIPSERV
SIP Refer Method (RFC 3515)
–– Serverless operation possible
Codecs (SIP): G.711 a-Law
G.711 μ-Law
G.722
1) The
relay output may only be connected to a SELV circuit! A SELV circuit as per
IEC/EN 60950-1 must be separated safely from a dangerous electrical circuit (e.g.
230 V or 110 V mains power), e.g. by means of double insulation. The SELV circuit
must not exceed 60 VDC or 42.4 VACpeak (30 VACeff)!
QoS requirements
–– Maximum one-way delay 100 ms
–– Delay-Jitter not above 50 ms
–– 0% packet loss for perfect audio quality
Bandwidth
–– For further information, see guideline “IoIP Technology”.
1)
The listed products and company names are brand names or registered trademarks of their respective owners.
Series Y-TU970H
Installation Instructions
Mounting instructions
–– Do not expose the emergency call station to extreme temperatures (see “Technical data”).
–– Observe the country specific standards for installation, mounting and configuration.
–– When opening the emergency call station, ESD precautions must be observed.
–– The emergency call station may only be opened by authorised service engineers.
Dimensions housing
Measuring units in mm (inch), not to scale!
Front view
205 (8.07)
320 (12.6)
4-M8-H6D16
260 (10.24)
Precautions
–– Observe the precautions for handling of electrostatic sensitive devices.
–– The emergency call station may only be opened by authorised service engineers.
IP Uplink
OUT1
OUT2
MIC+
MIC–
GND
LS+
T
0
LS–
IN1
IN2
JP1
JP1
Microphone
Handset
Loudspeaker
Function buttons
Call request (Y-TU970H-3B only: “T” top button,
“0” middle button, “X” lower button)
The technical data contained herein has been provided solely for informational
purposes and is not legally binding. Subject to change, technical or otherwise.
IoIP®, OpenDuplex® and Commend® are trademarks registered by Commend
International GmbH. All other brands or product names are trademarks or reg-
istered trademarks of the respective owner and have not been specifically
earmarked.