Vaillant Boiler Operating Instructions User Manual
Vaillant Boiler Operating Instructions User Manual
Operating instructions
ecoFIT pure
412 - 435
GB, IE
Publisher/manufacturer
Vaillant GmbH
Berghauser Str. 40 D-42859 Remscheid
Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810
[email protected] www.vaillant.de
Contents
Contents 6 Care and maintenance ................ 9
6.1 Maintenance .................................. 9
1 Safety ............................................ 3 6.2 Caring for the product .................... 9
1.1 Action-related warnings ................. 3 6.3 Reading maintenance
1.2 Intended use .................................. 3 messages ...................................... 9
2 Notes on the documentation ...... 4 6.4 Checking the condensate drain
2.1 Observing other applicable pipework and tundish................... 10
documents ..................................... 4 7 Decommissioning...................... 10
2.2 Storing documents......................... 4 7.1 Temporarily decommissioning
2.3 Applicability of the instructions....... 4 the product................................... 10
3 Product description..................... 4 7.2 Permanently decommissioning
3.1 Front view ...................................... 4 the product................................... 10
3.2 Control elements............................ 4 8 Recycling and disposal............. 10
3.3 Displayed symbols......................... 5 9 Guarantee and customer
service ........................................ 10
3.4 Information on the identification
plate ............................................... 5 9.1 Guarantee.................................... 10
3.5 Serial number ................................ 5 9.2 Customer service......................... 10
3.6 CE label ......................................... 6 Appendix ............................................... 11
3.7 Benchmark..................................... 6 A Status codes – Overview........... 11
4 Operation...................................... 6 B Troubleshooting ........................ 11
4.1 Operating concept ......................... 6
4.2 Basic display.................................. 7
4.3 Adjustment and display levels ....... 7
4.4 Cabinet-type casing ....................... 7
4.5 Opening the isolator devices ......... 7
4.6 Starting up the product .................. 7
4.7 Switching on the product ............... 7
4.8 Setting the heating flow
temperature ................................... 7
4.9 Setting the hot water
temperature ................................... 8
4.10 Switching off the product's
functions ........................................ 8
4.11 Protecting the heating installation
against frost ................................... 8
4.12 Switching the product to standby
mode.............................................. 9
5 Troubleshooting .......................... 9
5.1 Detecting and rectifying faults........ 9
5.2 Calling up (Live monitor) status
codes ............................................. 9
– Pressing to exit the selection levels ▶ Open the cold water stop valve.
– Not pressing any button for longer than
15 minutes. 4.6 Starting up the product
If there is an error message present, the ▶ Only start up the product once the cas-
basic displays switches to the error mes- ing has been completely closed.
sage.
4.7 Switching on the product
4.3 Adjustment and display levels ▶ Switch on the product via the main
The product has two adjustment and switch installed on-site.
display levels.
4.8 Setting the heating flow
The end user level contains information
temperature
and setting options that you require as the
end user. 1. Press ( ).
The installer level is reserved for the com- ◁ The target value of the heating flow
petent person. It is protected by a code. temperature appears on the display.
Only competent persons may change any
settings in the installer level. Note
The competent person may
have adjusted the maximum
possible temperature.
B Troubleshooting
Fault Cause Measure
Product does not The gas isolator cock installed on-site Open both gas isolator cocks.
start up: and/or the gas isolator cock on the
– No hot water product is closed.
– Heating re- The power supply in the building is dis- Check the fuse in the building.
mains cold connected. The product switches on automat-
ically when the power is restored.
The product is switched off. Switch on the product.
The heating flow temperature is set Set the heating flow and hot water
too low or to the Heating off position, temperature.
and/or the hot water temperature is set
too low.
There is air in the heating installation. Have a competent person purge
the heating installation.